• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

ANÁLISE COMPARATIVA DOS NÍVEIS DE ATRITO EM BRÁQUETES CONVENCIONAIS E AUTOLIGADOS / Friction levels comparative analysis in self-ligated and conventional brackets.

Picchioni, Mauro dos Santos 06 March 2007 (has links)
Made available in DSpace on 2016-08-03T16:31:07Z (GMT). No. of bitstreams: 1 Mauro dos Santos Pichioni.pdf: 2125883 bytes, checksum: cef06952dac67f4c03556888123fea6b (MD5) Previous issue date: 2007-03-06 / The friction between brackets and orthodontic wires is an important issue to be considered concerning to orthodontic treatment efficiency in the sliding mechanics. Because this, always there are a search for ways to reduce the friction levels during this type of mechanics. With the introduction of self-ligated bracketts, it was observed that one of these devices main characteristics would be a reduction levels reduction of friction between brackets and wires, and because this the movement could be more efficient, with the application of low forces when compared the using of brackets with conventional ligation systems. The purpose of this study is compare by means of laboratorial tests, the esthatic friction coefficients of one esthetic self-ligated bracket, one metallic self-ligated bracket and two metallic conventional brackets, with the orthodontic wires of different materials, section and sizes, to determine which brackets presents the lowest coefficients of friction, in situations of different angulations between wires and brackets. The results had demonstrated that self-ligated brackets had presented a static friction significantly lower at situations whitout angulation between the wire and brackets and when using small size wires, with more flexible material, when compared with conventional brackets. The metallic self-ligated bracket presented more friction, similar the conventional brackets, with the use larger diameter wires, without angulation between bracket and wire. The metallic self-ligated bracket presented higher static friction when compared with conventional brackets, with the use larger diameter wires, at situations with angulation betwen bracket and wire. / O atrito existente entre bráquetes e os fios ortodônticos é um fator importante a ser considerado quanto à eficiência do tratamento ortodôntico nas mecânicas de deslize. Em função disto, sempre se procurou maneiras de se diminuir os níveis de atrito durante a aplicação deste tipo de mecânica. Com o surgimento dos bráquetes autoligados, observou-se que uma das características principais destes dispositivos seria uma redução dos níveis de atrito entre os bráquetes e fios, e com isso poderia se obter um movimento de deslizamento eficiente com a aplicação de forças menores, quando comparado com o uso de bráquetes que tenham sistemas de amarração convencionais. O propósito deste trabalho foi comparar, por meio de ensaios laboratoriais, os níveis de atrito estático de um bráquete autoligado estético, de um bráquete autoligado metálico e dois tipos de bráquetes convencionais metálicos, com a utilização de fios ortodônticos de diferentes ligas, secção e diâmetros, para determinar quais bráquetes apresentam os menores coeficientes de atrito, em situações sem angulação, em angulações de primeira ordem e angulações de segunda ordem entre os diferentes fios e bráquetes. Os resultados demonstraram que os bráquetes autoligados apresentaram um atrito estático significativamente mais baixo nas situações onde não existiu angulação entre o fio e o bráquete e quando se utilizou fios de calibres menores e com material mais flexível, quando comparados com os bráquetes convencionais. O bráquete autoligado metálico apresentou maior atrito, semelhante aos bráquetes convencionais, com o uso dos fios de maior calibre, nas situações sem angulação. O bráquete autoligado metálico apresentou maior atrito estático que os bráquetes convencionais, nas situações de angulação, com o uso dos fios de maior calibre
2

Efeito da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial dos fios de níquel titânio / Effects of sterilization and clinical use in mechanical properties and surface roughness of nickel titanium wires

Prado, Murilo de Melo 25 March 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-21T11:25:26Z No. of bitstreams: 2 Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-21T11:40:15Z (GMT) No. of bitstreams: 2 Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-10-21T11:40:15Z (GMT). No. of bitstreams: 2 Dissertação - Murilo de Melo Prado - 2015.pdf: 11846576 bytes, checksum: c1b512a579f2a2894ce18a2204e03be5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-03-25 / This study evaluated the effects of sterilization and clinical use in the mechanical properties and surface roughness gauge wires 0.018 "nickel titanium termoset, with the addition of copper covers: Ormco (Glendora, CA, USA). Twenty-four samples were the evaluation of mechanical behavior in the load test and deflection, the scanning electron microscopy and atomic force microscope to check surface roughness. The tests were performed in four different situations: 1-packaged by the manufacturer (control); 2- packaged by the manufacturer and autoclaved; 3- after clinical use 60 days and disinfection and 4- and autoclaved clinical use. The data were submitted to ANOVA and Tukey test. By applying the deflection test on three points could be observed that the wires in all groups showed mechanical behavior in the activation / deactivation similar, with no significant statistical differences. All wires reached the end point of deactivation with forces approximate the control group (1.398 ± 0.19 N / mm). The AFM and SEM, all thermoset wires showed irregularities in its surface topography, and there were no major changes in surface pattern between the groups for the analyzed wire. The qualitative evaluation of surface roughness showed grooves and craters, influencing the surface of the wires smoothness, while the quantitative analyzes showed no statistically significant difference between the groups evaluated. The concluse is that sterilize the wires and use them clinically for 60 days did not alter the mechanical behavior and the surface roughness of the wires 0.018" NiTi Thermoset with addition of copper. / Este estudo avaliou os efeitos da esterilização e uso clínico nas propriedades mecânicas e rugosidade superficial de fios calibre 0,018” de níquel titânio termoativado com adição de cobre da marca: Ormco (Glendora, CA, USA). Vinte e quatro amostras foram submetidas à avaliação do comportamento mecânico no teste de carga e deflexão, à microscopia eletrônica de varredura e microscópio de força atômica para verificação da rugosidade superficial. Os testes foram realizados em quatro situações distintas: 1- embalado pelo fabricante (controle); 2- embalado pelo fabricante e autoclavado; 3- após uso clínico 60 dias e desinfecção e 4- uso clínico e autoclavado. Os dados obtidos foram submetidos à análise estatística ANOVA e teste de Tukey. Pela aplicação do teste de deflexão em três pontos pôde-se observar que os fios em todos os grupos apresentaram comportamento mecânico na ativação/desativação semelhantes, não havendo diferenças estatísticas significantes. Todos os fios chegaram ao ponto final de desativação com forças aproximadas ao grupo controle (1,398 ±0,19 N/mm). Ao AFM e MEV, todos os fios termoativados apresentaram irregularidades em sua topografia superficial, não sendo observadas grandes mudanças no padrão superficial entre os grupos para cada fio analisado. A avaliação qualitativa da rugosidade superficial demonstrou ranhuras e crateras, influenciando na lisura superficial dos fios, enquanto a avaliação quantitativa demonstrou não haver diferença estatisticamente significante entre os grupos avaliados. Concluiu-se que esterilizar os fios e utilizá-los clinicamente por 60 dias não alterou o comportamento mecânico e nem a rugosidade superficial dos fios 0,018” NiTi termoativados com adição de cobre.

Page generated in 0.0472 seconds