• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 212
  • 62
  • 24
  • 17
  • 14
  • 8
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 2
  • 2
  • Tagged with
  • 434
  • 434
  • 50
  • 49
  • 48
  • 45
  • 38
  • 37
  • 34
  • 33
  • 32
  • 32
  • 25
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Understanding the variations in fluorescence spectra of gynecologic tissue

Chang, Sung Keun. Richards-Kortum, Rebecca, January 2004 (has links) (PDF)
Thesis (Ph. D.)--University of Texas at Austin, 2004. / Supervisor: Rebecca Richards-Kortum. Vita. Includes bibliographical references. Available also from UMI company.
112

Complexation of metal ions in aqueous solution by fluorescent ligands containing pyridyl groups /

Oscarson, Karen Anna Martha. January 2004 (has links)
Thesis (M.S.)--University of North Carolina at Wilmington, 2004. / Includes bibliographical references (leaves : 94-97).
113

Application of fluorescence and UV resonance Raman spectroscopy to the diagnosis of neoplastic changes in cytological specimens /

Yazdi, Youseph, January 1997 (has links)
Thesis (Ph. D.)--University of Texas at Austin, 1997. / Vita. Includes bibliographical references (leaves 110-115). Available also in a digital version from Dissertation Abstracts.
114

Investigation of protein-induced formation of lipid domains and their dynamics using fluorescence energy transfer /

Wright, Jenny R. January 2005 (has links) (PDF)
Thesis (M.S.)--University of North Carolina at Wilmington, 2005. / Includes bibliographical references (leaves: 53-55)
115

Molecular Fourier imaging correlation spectroscopy for studies of molecular diffusion /

Fink, Michael Charles, January 2006 (has links)
Thesis (Ph. D.)--University of Oregon, 2006. / Typescript. Includes vita and abstract. Includes bibliographical references (leaves 104-111). Also available for download via the World Wide Web; free to University of Oregon users.
116

Neutral density profiles in argon helicon plasmas

Keesee, Amy M. January 1900 (has links)
Thesis (Ph. D.)--West Virginia University, 2006. / Title from document title page. Document formatted into pages; contains v, 218 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references.
117

Laser-induced fluorescence spectroscopy of the alkoxy radicals

Liu, Jinjun, January 2007 (has links)
Thesis (Ph. D.)--Ohio State University, 2007. / Title from first page of PDF file. Includes bibliographical references (p. 280-284).
118

Optimisation of a microfluidic device for the pre-concentration and size separation of cell free foetal DNA from maternal plasma by capillary electrophoresis

Rassie, Candice January 2012 (has links)
>Magister Scientiae - MSc / The discovery of cell free foetal DNA (cffDNA) in 1997 allows for the combination of accuracy as well as non-invasiveness for prenatal diagnosis. This non-invasive genetic test requires only a maternal blood sample from which the cffDNA can be isolated and analysed. In this work cffDNA was isolated from a maternal blood sample using a micro-fluidic device which was fabricated using hot embossing and laser ablation techniques. The DNA sample was first pre-concentration by electrokinetic trapping (EKT) and then isotachophoresis (ITP). The concentrated sample was then separated by size using capillary electrophoresis (CE), all in a single device. All parameters and processes concerned with the micro-fluidic device were optimised sequentially. These parameters include both the chemical components as well as the physical processes which occur. The DNA used for the optimisation protocol was analysed using fluorescence spectroscopy, agarose gel electrophoresis as well as an Agilent Bioanalyser. The optimised protocol included a 9% acrylamide/pDMA matrix, 3 M N,N-dimethylurea as a denaturing agent, with tris based buffers for pre-concentration steps and 1X TBE (tris/borate/EDTA) buffer for capillary electrophoresis. The applied voltage of ITP was 300 V and CE was carried out at 180 V. The timing at which DNA was extracted from the device was kept at time = 60 s intervals. The optimised protocol was then used for real sample analysis and these samples were obtained from mothers pregnant with male foetuses. The DNA extracted from the micro-fluidic device was then analysed using real time PCR (RT-PCR) in order to distinguish which was maternal and which was foetal. This was carried out by amplification of male and general (present in male and female) genes respectively. RT-PCR results confirmed that only the male specific gene was amplified in initial samples exiting the device and it was thus successful in isolating cffDNA from a maternal plasma sample.
119

Synthesis of fluorinated heterocyclic compounds and study of their interaction with DNA

Zeinali, Fatemeh January 2017 (has links)
Over fifty structurally diverse, novel fluorinated heteroarenes, have been successfully synthesised by SNAr reaction of a range of fluorinated arenes including pentafluoropyridine, hexafluorobenzene, and methyl pentafluorobenzoate by introduction of a range of groups such as imidazole, triazole, benzimidazole, benzotriazole, and carbazole. Different water solubilising side chains were introduced to some of the successfully synthesised fluorinated heteroarenes to improve water solubility and potential biological activity. X-ray crystal structures of over 10 compounds were obtained including those of two macrocyclic compounds containing 21- and 24-membered rings. The synthesised compounds have been characterized by elemental analysis, IR, 1H and 19F spectroscopy and high resolution mass spectrometry. These compounds have been screened for their biological activities and possible interaction with DNA by methods including UV-visible spectroscopy, fluorescence spectroscopy, co-crystallization for X-ray diffraction analysis, and antimicrobial activity. A number of the fluoroaryl benzimidazole derivatives have been tested against K-562 and MCF-7 cell lines and G361 and HOS cell lines. From the all tested compounds three tethered fluoroaryl benzimidazole derivatives demonstrated micromolar inhibition against K-562 and MCF-7 cell lines. These compounds, in addition to 1-tetrafluoropyrid-4-yl-2-tetrafluoropyrid-4-ylsulfanyl-1H-benzimidazole, also demonstrated micromolar inhibition against G361 and HOS cell lines. Two of the compounds were found to activate caspases leading to apoptosis.
120

Liberação de compostos orgânicos das resinas KaloreTM e FiltekTM Silorane em função da fonte de luz polimerizadora, dos meios de imersão e do pH / Release of organic resins KaloreTM and FiltekTM Silorane according to the source of curing light, the immersion solution and pH

Karina Alessandra Michelão Grecca Pieroni 13 June 2013 (has links)
Compostos orgânicos podem ser liberados dos materiais resinosos, mesmo após sua polimerização, como resultado da presença de monômeros residuais e do processo de degradação do próprio material, podendo ocasionar efeitos citotóxicos, genotóxicos e alergênicos. O objetivo do presente estudo, in vitro, foi avaliar a liberação de compostos orgânicos de dois materiais resinosos, recentemente lançados no mercado, que apresentam inovações em suas formulações (resinas Kalore TM - GC FUJI e FiltekTM Silorane - 3M ESPE), variando a fonte de luz polimerizadora (halógena ou LED), a solução de imersão (água ou saliva artificial) e o pH da solução de imersão (7 ou 4,5). Foram confeccionados 56 corpos de prova da resina Kalore TM e 56 da resina FiltekTM Silorane, sendo 28 polimerizados com luz halógena e 28 com luz LED. Após aleatorização, 7 corpos de prova de cada resina foram armazenados em água com pH neutro, 7 em água com pH ácido, 7 em saliva com pH neutro e 7 em saliva com pH ácido. A leitura dos espectros das soluções foi realizada por meio da espectroscopia de fluorescência após 1, 3, 24, 48, 72, 168, 216, 312, 432, 504 e 672 horas. Após 672 horas, ainda verificou-se a liberação de compostos orgânicos das resinas KaloreTM e FiltekTM Silorane em todas as condições avaliadas. A liberação de compostos orgânicos foi menor nos grupos experimentais polimerizados pela luz LED. A quantidade de compostos orgânicos liberados foi menor nas amostras imersas em saliva. A resina KaloreTM liberou uma quantidade maior de compostos orgânicos em pH neutro, independente do meio de imersão. A resina FiltekTMSilorane liberou uma quantidade maior de compostos orgânicos em pH ácido, quando imersas em água, e uma maior quantidade de compostos orgânicos em pH neutro, quando imersas em saliva. A resina FiltekTMSilorane liberou mais de um componente orgânico. A espectrometria de fluorescência permitiu avaliar a liberação de compostos orgânicos das resinas KaloreTM e FiltekTM Silorane. / Organic compounds may be released from the resin materials, even after polymerization, as a result of the presence of residual monomers and degradation of the material itself, which may cause cytotoxic, genotoxic and allergenics effects. The purpose of this study, in vitro, was to evaluate the release of organic compounds from two resin materials, recently launched on the market, that present innovations in their formulations (resins KaloreTM - GC FUJI and FiltekTM Silorane - 3M ESPE), varying the source curing light (LED or halogen), the immersion solution (water or artificial saliva) and the pH of the immersion solution (7 or 4.5). Were prepared 56 specimens resin KaloreTM and 56 resin FiltekTM Silorane, 28 polymerized with halogen light and 28 with LED light. After randomization, 7 samples of each resin were immersed in water at neutral pH, 7 in water at acid pH, 7 in the saliva at a neutral pH, and 7 in the saliva at acid pH. The reading of the spectra of the solutions was performed by fluorescence spectroscopy at 1, 3, 24, 48, 72, 168, 216, 312, 432, 504 and 672 hours. After 672 hours, there was still release of organic resins KaloreTM and FiltekTM Silorane under all conditions evaluated. The release of organic compounds was lower in the experimental groups polymerized by LED light. The amount of organic compounds released was lower in samples immersed in saliva. The resin KaloreTM released more organic compounds at neutral pH in both immersion media. The resin FiltekTMSilorane immersed in water released more organic compounds at acid pH, but when the resin was immersed in saliva the release of organic compounds was higher at neutral pH. The resin FiltekTMSilorane released more that one organic component. The fluorescence spectrometry allowed us to evaluate the release of organic compounds resins KaloreTM and FiltekTMSilorane.

Page generated in 0.0964 seconds