• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Projeto de um sistema ultra-sonico Doppler pulsatil multicanal para avaliação da vascularização periferica

Plasencia, Jorge Luis Manrique 03 August 2018 (has links)
Orientador: Saide Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-08-03T21:02:00Z (GMT). No. of bitstreams: 1 Plasencia_JorgeLuisManrique_M.pdf: 3217493 bytes, checksum: c24bd7b3a037a052bddbb858e3d1b5a2 (MD5) Previous issue date: 1994 / Resumo: A procura de um sistema de avaliação do comportamento do fluxo e da velocidade do sangue, de uma forma não invasiva e com uma alta resolução espacial, tem sido um almejado alvo de pesquisadores clínicos. Dentre as varias aplicações para este sistema a de principal interesse é o conhecimento do comportamento hemodinâmico, relevante para o diagnóstico precoce de patologias na vascularização periférica. Os equipamentos de fabricação nacional para esta finalidade, trabalham com sistemas Doppler de onda contínua, que tem a limitação de detectar a existência de turbulências produzidas por obstruções que comprometem no mínimo 50% da luz do vaso. O sistema Ultra-sônico Doppler Multicanal (SUDOF-M) desenvolvido neste trabalho, é capaz de fornecer, ao clínico, informações da distribuição da velocidade do fluxo sanguíneo em função do tempo, em três amostras de volume adjacentes em tempo real, de uma forma não invasiva e não traumática, com a finalidade de detectar turbulências produzidas por estenose de pequeno grau (menores que 30%). Possui também um modo de procura automática, que comandado pelo microcomputador PC/XT, localiza a artéria e mantém os canais de processamento do sinal no centro da luz arterial, dando mais liberdade de atuação para o clínico / Abstract: Not informed / Mestrado / Mestre em Engenharia Elétrica
2

Avaliação da técnica de dopplerfluxometria e índice de resistividade das artérias renais em cadelas com piometra

Santos, Roberta Valeriano dos [UNESP] 28 August 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-08-28Bitstream added on 2014-06-13T19:30:16Z : No. of bitstreams: 1 santos_rv_me_botfmvz_parcial.pdf: 79719 bytes, checksum: f4ab1d149354573a2846050244472077 (MD5) Bitstreams deleted on 2015-06-03T11:42:21Z: santos_rv_me_botfmvz_parcial.pdf,. Added 1 bitstream(s) on 2015-06-03T11:43:58Z : No. of bitstreams: 1 000714417_20150828.pdf: 65227 bytes, checksum: 90f4fc7056ae64f6c143ce08d790017e (MD5) Bitstreams deleted on 2015-08-28T16:09:02Z: 000714417_20150828.pdf,. Added 1 bitstream(s) on 2015-08-28T16:10:02Z : No. of bitstreams: 1 000714417.pdf: 574872 bytes, checksum: 3f3b39b6ebd6132cff9565fb949a53c6 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Cadelas com piometra frequentemente desenvolvem alterações renais transitórias. O estudo de métodos para investigar a injúria renal nessas cadelas, assim como entender a fisiopatologia dessas alterações, tem sido descrito na literatura recente. A ultrassonografia Doppler fornece informações importantes sobre o fluxo sanguíneo e a resistência vascular dos rins. O presente estudo avaliou a aplicabilidade deste recurso na avaliação renal de 30 cadelas com piometra comparativamente a 24 cadelas hígidas do grupo controle, em diestro e anestro. Com exceção dos valores séricos de ureia e creatinina, todas as variáveis avaliadas: contagem de leucócitos, plaquetas, hematócrito, relação proteína/creatinina, relação GGT/creatinina, densidade urinária, perfusão renal e índice de resistividade das artérias renais principais, interlobares cranial, média e caudal foram diferentes entre o grupo controle e o experimental. Todas as cadelas com piometra fechada apresentaram as medianas dos valores do índice de resistividade, acima de 0,7, valor proposto como limítrofe para normalidade. O estudo Doppler detectou alterações de perfusão renal e do IR das artérias renais principais e interlobares na maioria das cadelas acometidas com piometra / Bitches with pyometra often develop transient renal changes. The study of methods to investigate the renal injury in these bitches, as well as to understand the pathophysiology of these changes, has been described in recent literature. Doppler ultrasound provides important information about blood flow and vascular resistance of the kidneys. This study evaluated the applicability of this resource in the renal evaluation of 30 bitches with pyometra compared with 24 healthy bitches of the control group, in diestrus and anestrus. With the exception of serum urea and creatinine, all variables: leukocytes, platelets, hematocrit, protein/creatinine ratio, GGT/creatinine ratio, urine specific gravity, renal perfusion and resistivity index (RI) of the main renal arteries, cranial, middle and caudal interlobar arteries were different between the control and experimental group. All the bitches with closed pyometra presented the median values of the resistivity index above 0,7, the proposed value considered as borderline for normality. Doppler study revealed changes in renal perfusion and RI of the main renal and interlobar arteries in most affected bitches with pyometra
3

Avaliação da técnica de dopplerfluxometria e índice de resistividade das artérias renais em cadelas com piometra /

Santos, Roberta Valeriano dos. January 2012 (has links)
Orientador: Nereu Carlos Prestes / Coorientador: Vânia Maria de Vasconcelos Machado / Banca: Maria Denise Lopes / Banca: Maria Cristina Ferrarini Nunes Soares Hage / Resumo: Cadelas com piometra frequentemente desenvolvem alterações renais transitórias. O estudo de métodos para investigar a injúria renal nessas cadelas, assim como entender a fisiopatologia dessas alterações, tem sido descrito na literatura recente. A ultrassonografia Doppler fornece informações importantes sobre o fluxo sanguíneo e a resistência vascular dos rins. O presente estudo avaliou a aplicabilidade deste recurso na avaliação renal de 30 cadelas com piometra comparativamente a 24 cadelas hígidas do grupo controle, em diestro e anestro. Com exceção dos valores séricos de ureia e creatinina, todas as variáveis avaliadas: contagem de leucócitos, plaquetas, hematócrito, relação proteína/creatinina, relação GGT/creatinina, densidade urinária, perfusão renal e índice de resistividade das artérias renais principais, interlobares cranial, média e caudal foram diferentes entre o grupo controle e o experimental. Todas as cadelas com piometra fechada apresentaram as medianas dos valores do índice de resistividade, acima de 0,7, valor proposto como limítrofe para normalidade. O estudo Doppler detectou alterações de perfusão renal e do IR das artérias renais principais e interlobares na maioria das cadelas acometidas com piometra / Abstract: Bitches with pyometra often develop transient renal changes. The study of methods to investigate the renal injury in these bitches, as well as to understand the pathophysiology of these changes, has been described in recent literature. Doppler ultrasound provides important information about blood flow and vascular resistance of the kidneys. This study evaluated the applicability of this resource in the renal evaluation of 30 bitches with pyometra compared with 24 healthy bitches of the control group, in diestrus and anestrus. With the exception of serum urea and creatinine, all variables: leukocytes, platelets, hematocrit, protein/creatinine ratio, GGT/creatinine ratio, urine specific gravity, renal perfusion and resistivity index (RI) of the main renal arteries, cranial, middle and caudal interlobar arteries were different between the control and experimental group. All the bitches with closed pyometra presented the median values of the resistivity index above 0,7, the proposed value considered as borderline for normality. Doppler study revealed changes in renal perfusion and RI of the main renal and interlobar arteries in most affected bitches with pyometra / Mestre

Page generated in 0.0864 seconds