• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Diagnóstico da poluição sonora na cidade do Recife-PE

ARAUJO, Karina Clementino de 31 January 2013 (has links)
Submitted by Nayara Passos (nayara.passos@ufpe.br) on 2015-03-05T12:40:26Z No. of bitstreams: 2 DISSERTAÇÃO KARINA DE ARAUJO.pdf: 5181070 bytes, checksum: 667c25fada82944fbf9d6b9d70cd75c8 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T12:40:26Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO KARINA DE ARAUJO.pdf: 5181070 bytes, checksum: 667c25fada82944fbf9d6b9d70cd75c8 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013 / O ruído é definido como um som indesejável, desagradável que, ao alcançar níveis prejudiciais à saúde e ao sossego público, passa a ser denominado de poluição sonora. Esse tipo de degradação ambiental ocupa lugar de destaque na sociedade moderna, atingindo um grande número de pessoas. É considerada a terceira maior forma de poluição do planeta e no Brasil é um grave e crescente problema de saúde e segurança pública. O presente trabalho teve como objetivo diagnosticar os níveis sonoros do ruído urbano na cidade do Recife no período 2010 a 2012, através de levantamento quantitativo no órgão fiscalizador municipal. As denúncias comunicadas pela população e encaminhadas por outros órgãos fiscalizadores foram registradas em formulário próprio da Secretaria de Meio Ambiente e posteriormente organizadas em planilhas eletrônicas. Foram estabelecidos roteiros por RPA para fiscalização das denúncias. Para aferição do ruído, foi utilizado o decibelímetro Type 2240 devidamente calibrado, no nível sonoro equivalente (Leq), curva de ponderação “A”, com circuito de resposta rápida, microfone afastado 1,50 m dos limites da propriedade onde se dá o incômodo e à altura de 1,20m do solo, conforme determina o Código Municipal de Meio Ambiente da Cidade do Recife. Foram registradas 1.876 denúncias em 2010, 1.048 no ano 2011 e 728 em 2012. Na RPA 1 a principal fonte de ruído foi a propaganda sonora dos estabelecimentos comerciais, já para as Regionais 2 a 6 o som em alto volume advindo de bares e restaurantes se destacou. Todas as Regionais apresentaram aferições acima do limite máximo permitido na legislação municipal vigente. Mediante o descumprimento à lei foram emitidos 140 autos de Infração em 2010, 124 em 2011 e 91 em 2012. O estudo identificou quais as principais fontes geradoras de ruído em cada RPA e constatou que há descumprimento ao limite máximo permitido estabelecido na legislação.
2

Identificação de Fontes da Matéria Particulada do Aerossol Atmosférico De São Paulo / Identification of Particulate Matter Sources in Atmospheric Aerosol of the São Paulo

Andrade, Maria de Fatima 05 August 1993 (has links)
Neste trabalho aplicamos três modelos: receptor, de equilíbrio químico e de dispersão, para a identificação de fontes da Matéria Particulada Inalável do aerossol atmosférico de São Paulo. Utilizamos dados de dois experimentos realizados no campus da USP em São Paulo. ° experimento realizado em 1986 teve como local de amostragem o Instituto de Física, enquanto o experimento de 1989 foi realizado no Instituto de Química como parte do SPACEX (São Paulo Atmosphere Characterization Experiment). As amostras de Matéria Particulada Fina (MPF) e Matéria Particulada Grossa (MPG) foram submetidas à análise gravimétrica e à análise PIXE (Particle Induced X-Ray Emission). Esta última foi realizada no Laboratório de Pesquisas Nucleares de Gent, Bélgica. ° modelo receptor utilizado foi a Análise de Componentes Principais (ACP) que identificou 5 perfis de fontes (5 componentes principais) para a MPF e quatro para a MPG. Para a MPF, entretanto, somente 3 fontes poluidoras puderam ser claramente identificadas: poeira do solo (ressuspensão), processos industriais e queima de óleo combustível (caldeiras). Para a MPG foram identificadas quatro fontes: poeira do solo, processos industriais, queima de óleo combustível e emissões de spray marinho. As fontes identificadas como queima de óleo combustível juntamente com as emissões industriais foram responsáveis por aproximadamente 53% da massa de MPF. Enquanto que a poeira do solo ficou responsável por 60% da massa de MPG. Verificamos com o MARS (Modelo para um Sistema Aerossol Reativo), que para concentrações molares de NH3 maiores que de S04\' o aerossol de sulfato, nitrato e amônio consiste, principalmente, de uma mistura de (NH4)2S04 e NH4N03, que podem estar dissociados ou não, dependendo da umidade relativa. Calculamos, também, as taxas de oxidação do S02 e encontramos que as taxas mais elevadas são obtidas na reação com o 02 catalisada por Mn e Fe. Com o objetivo de determinarmos a origem do S02 encontrado durante o SPACEX, estudamos a dispersão do S02 através da aplicação do modelo tipo pluma gaussiana ISC (Industrial Source Complex) da EPA (Environmental Protection Agency). Consideramos como fonte o trecho da marginal do Rio Pinheiros entre as pontes do Jaguaré e Eusébio Matoso. As estimativas obtidas com o modelo para a concentração de S02 durante o SPACEX, foram muito mais baixas que os valores medidos, indicando que existem outras fontes de grande porte contribuindo para a concentração desse poluente. A combinação desses modelos apresentou-se como uma metodologia que pode fornecer mais subsídios para a identificação das fontes e dos processos de geração da Matéria Particulada. / Receptor, Chemical Equilibrium and Dispersion Models were applied to identify the inhalable particles sources of the São Paulo Atmospheric Aerosols. The data were collected during two experiments in the São Paulo University Campus, in 1986 and 1989. The 1986 experiment was performed in the Physics Institute, and the 1989 experiment was part of the SPACEX (São Paulo Atmosphere Characterization Experiment). The fine and coarse particles (FP and CP, respectively) of the SFU samples were analyzed by PIXE and by gravimetry. The PIXE analysis were performed at the University of Gent, Selgium. Absolute Principal Component Analysis (APCA) identified five sources profiles to the FP and four to the CP. Sut, only three sources could be surely identified to the FP: resuspended soi! dust, industrial emissions and oi! burning. The sources profiles related to the CP were: resuspended soi! dust, industrial emissions, oil burning and sea-salt aerosol. The oil burning and industrial emissions were responsible for, approximately, 53% of FP, meanwhile, the soi! dust was responsible for 60% of CP. In order to predict the equilibrium concentrations of sulfate, nitrate and ammonium aerosols we applied the MARS (Model for an Aerosol Reacting System) to our data. In our case, having NH3 higher than 504 concentrations, the predicted was the following composition: (NH4)2504 and NH4N03 , that can be present dissociate or not, related to the relative humidity. The higher oxidation rates were found to the reaction of S02 with 02 catalyzed by Mn and Fe. The EPA (Environmental Protection Agency) Industrial Source Complex Model (lSC) was applied to describe the S02 dispersion from the \"Rio Pinheiros Marginal\" to the University of São Paulo Campus. The estimated values were lower than the measured ones. The combination of these models seemed to be very useful in the source profile identification of complex regions as São Paulo Metropolitan Area.
3

Identificação de Fontes da Matéria Particulada do Aerossol Atmosférico De São Paulo / Identification of Particulate Matter Sources in Atmospheric Aerosol of the São Paulo

Maria de Fatima Andrade 05 August 1993 (has links)
Neste trabalho aplicamos três modelos: receptor, de equilíbrio químico e de dispersão, para a identificação de fontes da Matéria Particulada Inalável do aerossol atmosférico de São Paulo. Utilizamos dados de dois experimentos realizados no campus da USP em São Paulo. ° experimento realizado em 1986 teve como local de amostragem o Instituto de Física, enquanto o experimento de 1989 foi realizado no Instituto de Química como parte do SPACEX (São Paulo Atmosphere Characterization Experiment). As amostras de Matéria Particulada Fina (MPF) e Matéria Particulada Grossa (MPG) foram submetidas à análise gravimétrica e à análise PIXE (Particle Induced X-Ray Emission). Esta última foi realizada no Laboratório de Pesquisas Nucleares de Gent, Bélgica. ° modelo receptor utilizado foi a Análise de Componentes Principais (ACP) que identificou 5 perfis de fontes (5 componentes principais) para a MPF e quatro para a MPG. Para a MPF, entretanto, somente 3 fontes poluidoras puderam ser claramente identificadas: poeira do solo (ressuspensão), processos industriais e queima de óleo combustível (caldeiras). Para a MPG foram identificadas quatro fontes: poeira do solo, processos industriais, queima de óleo combustível e emissões de spray marinho. As fontes identificadas como queima de óleo combustível juntamente com as emissões industriais foram responsáveis por aproximadamente 53% da massa de MPF. Enquanto que a poeira do solo ficou responsável por 60% da massa de MPG. Verificamos com o MARS (Modelo para um Sistema Aerossol Reativo), que para concentrações molares de NH3 maiores que de S04\' o aerossol de sulfato, nitrato e amônio consiste, principalmente, de uma mistura de (NH4)2S04 e NH4N03, que podem estar dissociados ou não, dependendo da umidade relativa. Calculamos, também, as taxas de oxidação do S02 e encontramos que as taxas mais elevadas são obtidas na reação com o 02 catalisada por Mn e Fe. Com o objetivo de determinarmos a origem do S02 encontrado durante o SPACEX, estudamos a dispersão do S02 através da aplicação do modelo tipo pluma gaussiana ISC (Industrial Source Complex) da EPA (Environmental Protection Agency). Consideramos como fonte o trecho da marginal do Rio Pinheiros entre as pontes do Jaguaré e Eusébio Matoso. As estimativas obtidas com o modelo para a concentração de S02 durante o SPACEX, foram muito mais baixas que os valores medidos, indicando que existem outras fontes de grande porte contribuindo para a concentração desse poluente. A combinação desses modelos apresentou-se como uma metodologia que pode fornecer mais subsídios para a identificação das fontes e dos processos de geração da Matéria Particulada. / Receptor, Chemical Equilibrium and Dispersion Models were applied to identify the inhalable particles sources of the São Paulo Atmospheric Aerosols. The data were collected during two experiments in the São Paulo University Campus, in 1986 and 1989. The 1986 experiment was performed in the Physics Institute, and the 1989 experiment was part of the SPACEX (São Paulo Atmosphere Characterization Experiment). The fine and coarse particles (FP and CP, respectively) of the SFU samples were analyzed by PIXE and by gravimetry. The PIXE analysis were performed at the University of Gent, Selgium. Absolute Principal Component Analysis (APCA) identified five sources profiles to the FP and four to the CP. Sut, only three sources could be surely identified to the FP: resuspended soi! dust, industrial emissions and oi! burning. The sources profiles related to the CP were: resuspended soi! dust, industrial emissions, oil burning and sea-salt aerosol. The oil burning and industrial emissions were responsible for, approximately, 53% of FP, meanwhile, the soi! dust was responsible for 60% of CP. In order to predict the equilibrium concentrations of sulfate, nitrate and ammonium aerosols we applied the MARS (Model for an Aerosol Reacting System) to our data. In our case, having NH3 higher than 504 concentrations, the predicted was the following composition: (NH4)2504 and NH4N03 , that can be present dissociate or not, related to the relative humidity. The higher oxidation rates were found to the reaction of S02 with 02 catalyzed by Mn and Fe. The EPA (Environmental Protection Agency) Industrial Source Complex Model (lSC) was applied to describe the S02 dispersion from the \"Rio Pinheiros Marginal\" to the University of São Paulo Campus. The estimated values were lower than the measured ones. The combination of these models seemed to be very useful in the source profile identification of complex regions as São Paulo Metropolitan Area.

Page generated in 0.0621 seconds