• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 11
  • 11
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Caracterização e estampabilidade de um aço SAE 1080 fosfatizado. / Characterization and stampability of SAE 1080 phosphatized steel.

Daniel Augusto Ferro 04 February 2015 (has links)
Devido a crescente necessidade de elevação dos níveis de conformação em peças estampadas em geral, existe uma demanda cada vez maior em ligas e processos diversificados que atendam as variadas exigências do setor de produtos estampados e posteriormente tratados termicamente para aumento de dureza. Desse modo desenvolveu-se a liga C80U modificada, que é uma variante da liga C80U especificada na norma DIN EN ISO 4957 porém com adição de Cromo, entretanto a liga C80U modificada ainda é pouco estudada e pouca informação técnica se tem a seu respeito. Com a finalidade de melhor conhecimento técnico dessa liga, foram conduzidos estudos de caracterização em amostras laminadas a quente e após processo de esferoidização posteriormente sendo revestidas com fosfato de zinco. Foram realizados estudos de composição química, microestrutura, textura cristalográfica, propriedades mecânicas e estrutura do fosfato, além de levantamento da curva CLC através do método Nakazima e evolução da rugosidade 2D e 3D em amostras com e sem revestimento de fosfato, antes e após conformação. Através dos resultados parciais encontrados, foi possível definir o lado da curva CLC relacionado ao estiramento da chapa bem como comparar o deslocamento e a força do punção no teste Nakazima conformando-se amostras esferoidizadas sem revestimento e com revestimento de fosfato. / Due to the increasing demand for enhanced formability levels of stamped parts in general, there is also an increasing demand for various alloys and processes that comply with the various requirements associated with stamped products that are subsequently heat treated to increase their hardness. Along this line, a modified C80U alloy has been developed, which is a variant of the alloy C80U specified in the standard DIN EN ISO 4957 but with the addition of Chrome. However, this alloy is still poorly studied and little technical information is available about it. In order to increase the knowledge of this alloy, characterization studies were conducted on hot rolled, after spheroidization and subsequently coated with zinc phosphate samples. The studies performed included chemical composition, microstructure, crystallografic texture, mechanical properties and analysis of the phosphate structure, as well as Nakazima tests in order to obtain the forming limit diagram (FLD) curve and the 2D and 3D roughness evolution of spheroidized samples coated and uncoated before and after the stamping process. Through the partial results obtained, it was possible to define the side of FLD curve related to stretching of the sheet as well as comparing the displacement and force of the punch on Nakazima test, stamping spheroidized samples both uncoated and coated with zinc phosphate.
12

\"Estudo da evolução da reação de presa do cimento de fosfato de zinco através de luz laser, aplicando a técnica óptica de speckle dinâmico\" / Study of evolution of zinc phosphate cement´s setting reaction by laser, applying an optics technique of dynamic speckle

Dino Jeiset Kon 09 October 2006 (has links)
A cimentação de próteses e/ou de outros elementos protéticos constituem-se em uma preocupação permanente, já que uma das grandes aplicações do cimento de fosfato de zinco é como agente cimentante. No entanto, a reação de presa do cimento de fosfato de zinco, assim como o tempo de sua presa final, não estão ainda completamente esclarecidos. O presente estudo visa analisar, microestruturalmente, a evolução da reação de presa do cimento de fosfato de zinco. Mais especificamente, buscou-se mensurar, baseado no fenômeno conhecido como speckle dinâmico, o tempo de duração da reação de presa do cimento de fosfato de zinco, desde o momento do término da espatulação até a sua presa completa, em ambiente com temperatura e umidade relativa do ar controlada. A metodologia utilizada consiste na análise do speckle dinâmico obtido através da luz laser, em um ensaio não-destrutivo. A partir dos dados coletados pela técnica óptica de speckle, usando algoritmos computacionais, foi possível estabelecer os coeficientes de correlação temporal e momentos de intensidade. O tratamento estatístico permitiu relacionar e comparar com outros parâmetros tradicionais, químicos e mecânicos macroestruturais já existentes e estudados por outros autores. Pode-se concluir que os resultados alcançados pela nova técnica e pelos métodos convencionais são convergentes. / The prosthesis cementation and/or other prosthetic elements, consists in permanent concern, since one of the major applications of zinc phosphate cement is as lutting agent. This study aims at the microstructural analyze to the evolution of the zinc phosphate cement´s setting reaction. More specifically, searched to verify, based on the known phenomenon as dynamic speckle, how long takes the setting reaction of zinc phosphate cement, since the moment of the ending of the mix until your complete setting, in environment with air relative humidity and temperature controlled. The used methodology consist in the analysis of dynamic speckle gotten through the laser, in a non-destructive assay. From the data supplied by the laser speckle, it was possible to establish the temporal correlation coefficients and intensity moments. The statistical treatment, allowed to compare and relate with other traditional, chemical and mechanical macrostructural parameters, already existing and studied by other authors. It can be conclude that outcomes achieved by the new technique and with the conventional methods are convergent.
13

Avaliação da infiltração marginal e da resistência à tração de coroas metálicas após abertura oclusal para terapia endodôntica: estudo in vitro / Evaluation of cast crowns microleakage and retentive strength after occlusal Access for endodontic therapy: in vitro study

Rogério Issao Sonoki 20 September 2006 (has links)
Este estudo in vitro teve como objetivo determinar a infiltração marginal e resistência à remoção por tração de coroas totalmente metálicas, cimentadas com cimento de fosfato de zinco e que foram submetidas à abertura oclusal para tratamento endodôntico. Foram usados 20 dentes molares (Banco Permanente de Dentes Humanos da FOUSP). Os dentes foram fixados sobre uma base acrílica de secção circular e foram torneados configurando preparos para coroas totais com dimensões de altura e diâmetro padronizadas. Coroas metálicas em Ni Cr foram fundidas através da técnica de enceramento direto e cimentadas com cimento de fosfato de zinco com carga axial de 5 Kg por 10 minutos. Os corpos de prova foram divididos em: Grupos Controle GC1 e GC2, que utilizaram os mesmos corpos de prova, e Grupo Experimental (GE). Todos os corpos de prova foram mantidos em água destilada para que não se desidratassem. Os espécimes dos grupos GC1 e GC2 foram mantidos sem nenhuma intervenção e os do grupo GE foram perfurados com broca de carbide de tungstênio, simulando uma cirurgia de acesso endodôntico. As amostras dos grupos GC2 e GE foram submetidas à ciclagem térmica de 700 ciclos entre 5º e 55º C. Em seguida foram mantidos em uma solução de azul de metileno 0,5%, ph 7,2 por 4 horas a 37º C. Foram submetidos ao ensaio mecânico de tração das coroas em uma máquina universal de ensaios Kratos SV 100, regulada para trabalhar a uma velocidade de ensaio de 0,5 mm/minuto. Os resultados obtidos foram submetidos à análise estatística pelos testes t de Student e as infiltrações avaliadas pela correlação linear de Spearman. A análise inferencial dos resultados dos testes de tração demonstrou com um nível de significância p=0,108, entre os grupos GC1 e GC2, e p=0,502, entre os grupos GC2 e GE, não haver diferença estatisticamente significante. As médias dos valores obtidos nos testes de tração e os seus respectivos desvios padrão foram: GC1 13,96+/-4, 48, GC2 11,26+/-2,269 e GE 10,09+/-4,86 (valores em Kgf). A análise visual subjetiva da infiltração nos corpos de prova indicou que o grupo GE apresentou o maior grau de infiltração marginal com presença do corante atingindo o terço oclusal das paredes axiais (mediana dos scores 3). O grupo GC2 apresentou infiltração marginal no terço médio (mediana dos scores 2). O grupo GC1 apresentou infiltração marginal no terço cervical e médio (mediana dos scores 1). / This in vitro study had the objective to determine the marginal microleakage and the retentive strength of totally metallic crowns, cemented with zinc phosphate cement and subjected to occlusal access for endodontic treatment. 20 human molars (Banco Permanente de Dentes Humanos da FOUSP) have been used for the experiment. The teeth were fixed on a circular acrylic section base and were prepared with standardized dimensions. Metallic crowns in Ni Cr were cast with the direct waxing technique and cemented with zinc phosphate cement with vertical load of 5 kg for 10 minutes. The specimens were divided in groups: Group Control 1 (GP1), Group Control 2 (GP2) and Group Experimental (GE). All the specimens were kept on distillated water so that they wouldn’t dehydrate. The specimens of the groups GC1 and GC2 were kept without any intervention and the ones of the group GE were drilled with a tungstein carbide bur, simulating an endodontic access surgery. Next, the samples of groups GC2 and GE were subjected to a thermal cycling of 700 cycles between 5º and 55º C. To verify the existence of micro infiltration, it was used the methylene blue dye test, 0,5%, ph 7,2 for 4 hours at 37ºC. The specimens were subjected to the load of tension in a universal tensile testing machine Kratos SV 100 at speed 0,5 mm/min. Statistical analyses with t tests showed no significant difference between crown retention before and after endodontic access preparation (p=0,108). The mean displacement forces were: GC1 13,96+/-4,48, GC2 11,26+/-2,269 e GE 10,09+/-4,86 (value in Kgf). With the Spearman’s evaluation test the microleakage was measured. The results showed a greater median of score in GE (score 3). The GC2 and GC1 showed median scores 2 and 1 in order.

Page generated in 0.1836 seconds