• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Intra-operative biomechanical analysis for improvement of intra-articular fracture reduction

Kern, Andrew Martin 01 August 2017 (has links)
Intra-articular fractures (IAFs) often lead to poor outcomes, despite surgeons’ best efforts at reconstructing the fractured articular surface. The objective of articular fracture reduction is to improve joint congruity thereby lower articular contact pressure and minimize the risk of post-traumatic osteoarthritis (PTOA). Surgical fracture reductions performed using less invasive approaches (i.e., percutaneously) rely heavily upon C-arm fluoroscopy to judge articular surface congruity. Based on varied outcomes, it appears that the use of 2D imaging alone for this purpose may prove inadequate. Despite this, there has been little investigation into novel metrics for assessment of reduction quality. This work first explores seven methods for assessment of reduction quality (3 2D, 3 3D, and one biomechanical). The results indicate that metrics which take 3D measurement or joint biomechanics into account when characterizing reduction quality are more strongly correlated with PTOA development. A computer assisted surgery system, which provides up-to-date 3D fracture geometry and contact stress distributions intra-operatively, was developed. Its utility was explored in a series of ten cadaveric tibial plafond fracture reductions, where contact stresses and contact areas were compared in surgeries with vs. without biomechanical guidance. The use of biomechanical guidance caused an increase in surgical time and fluoroscopy usage (39% and 17%, respectively). However, it facilitated decreases in the mean and maximum contact stress by 0.7 and 1.5 MPa, respectively. Contact areas engaged at known deleterious levels (contact stress > 4.5 MPa) were also 44% lower in cases which used guidance. The findings of this work suggest that enhanced visualization of a fracture intra-operatively may facilitate improved long-term outcomes. Further development and study of this system is warranted.
2

Computer-assisted fracture reduction in an orthopaedic pre-operative planning workflow

Mangs, Ludvig January 2017 (has links)
This report presents three implementations for solving 3D puzzles of fractured bones: two semi-automatic ones and one which is automatic. These are compared using qualitative as well as quantitative tests to find out if less interaction can yield equal or better results. Qualitative tests are performed on real clinical data from CT-scans. A model created in Blender is used for quantitative tests. Test results have shown that each implementation has its own strengths and weaknesses which can make them usable for different types of fractures. It may be possible to combine automatic solutions and manual ones to increase the number of solvable cases. The conclusion is that it is possible to reduce fractures with less user interaction and still get equal or better results, but it depends on the fracture case as well as the user.
3

Incidência e fatores associados à ocorrência de infecção de sítio cirúrgico nas fraturas diafisárias do fêmur e da tíbia tratadas com haste intramedular: estudo prospectivo / Incidence and factors associated with the occurrence of surgical site infection in femoral and tibial diaphyseal fractures treated with intramedullary nailing: prospective study

Oliveira, Priscila Rosalba Domingos de 27 June 2018 (has links)
INTRODUÇÃO: As fraturas diafisárias do fêmur e da tíbia encontram-se em destaque devido a sua elevada incidência e alto impacto econômico e social. A osteossíntese com uso da haste intramedular (HIM) é o procedimento cirúrgico de escolha. A infecção de sítio cirúrgico (ISC) relacionada a HIM é considerada uma complicação grave e de difícil tratamento. OBJETIVOS: 1. Determinar a incidência de ISC após a implantação de HIM para fixação de fraturas diafisárias de fêmur e tíbia. 2. Avaliar os possíveis fatores associados. MÉTODOS: Estudo prospectivo observacional do tipo coorte. Para definição de ISC, foram utilizados os critérios do CDC-NHSN. A incidência de ISC foi calculada como a relação entre o número de pacientes com ISC em relação ao número total de pacientes. Para avaliação dos potenciais fatores associados, foram analisados aqueles relacionados aos pacientes (idade, gênero, índice de massa corpórea, presença de focos ativos de infecção à distância, presença condições imunossupressoras, avaliação de estado físico segundo escore ASA, etilismo, tabagismo, uso de drogas ilícitas, politrauma, etiologia do trauma, tipo de fratura quanto à exposição óssea, classificação da fratura segundo Müller AO, classificação segundo Tcherne para as fraturas fechadas, classificação segundo Gustilo-Anderson para as fraturas expostas, permanência em outro serviço de saúde, uso prévio de fixador externo, antecedente de manipulação cirúrgica na topografia da fratura, uso de hemoderivados); dos fatores relacionados ao ambiente cirúrgico e ao ato operatório (classificação da ferida quanto ao potencial de contaminação, duração da cirurgia, tricotomia, possível contaminação intraoperatória, uso de antimicrobianos relacionados ao procedimento cirúrgico, uso de drenos, ocorrência de hipotermia ou hipóxia no período perioperatório, tipo de HIM utilizada, fresagem, necessidade de necessidade de reparo do revestimento cutâneo associado à topografia da fratura, uso de terapia por pressão negativa) e dos fatores relacionados à microbiota (colonização por S. aureus ou A. baumannii). RESULTADOS: 221 pacientes foram incluídos e completaram o período de 12 meses de seguimento. A incidência de ISC associada à osteossíntese com HIM foi de 11,8%. Na análise inicial por regressão logística não ajustada, os seguintes fatores apresentaram associação com ISC: etiologia do trauma relacionada a acidentes de carro e bicicleta, classificação Müller AO do traço da fratura 2 ou 3, uso prévio de fixador externo, cirurgias com maiores tempos de duração, uso de drenos, uso de terapia por pressão negativa e necessidade de reparo do revestimento cutâneo na topografia da fratura. Na análise ajustada por regressão logística múltipla, contudo, apenas o uso prévio de fixador externo e a necessidade de reparo do revestimento cutâneo mantiveram-se associados à ocorrência de ISC. CONCLUSÕES: A incidência de ISC associada à fixação de fraturas diafisárias de fêmur e tíbia com HIM foi de 11,8%. O uso prévio de fixadores externos e a necessidade de reparo do revestimento cutâneo na topografia da fratura foram fatores associados à ocorrência de infecção / BACKGROUND: Diaphyseal fractures of femur and tibia are prominent due to its high incidence and high economic and social impact. Intramedullary nailing (IN) is the surgical procedure of choice. Surgical site infection (SSI) related to this procedure is considered a difficult to treat complication. OBJECTIVES: Determine the incidence of SSI after IM in femoral and tibial diaphyseal fractures and evaluate possible risk factors. METHODS: Prospective observational cohort study. SSI was defined according to CDC-NHSN criteria. Incidence of SSI was calculated as the ratio between the number of patients with SSI and total number of patients. Analysis of potential risk factors included patients-related factors (age, gender, body mass index, active foci of infection, immunosuppressive conditions, ASA score, alcohol or illicit drug abuse, smoking, polytrauma, etiology of fracture, type of fracture if closed or open, classification of fracture according to Müller AO, Tcherne classification for closed fractures, to Gustilo-Anderson classification for open fractures, previous surgical manipulation, use of blood products); environmental and surgical-related factors (surgical wound classification, duration of surgery, hair removal, intraoperative contamination, antimicrobial use, presence of drains, hypothermia or hypoxia in the perioperative period, type of IN used, reaming, need for muscle or skin flap repair, use of negative pressure therapy) and microbiotarelated factors (S. aureus and A. baumannii colonization). RESULTS: 221 patients were included and completed the 12-month follow-up period. Incidence of SSI was 11.8%. In the initial analysis by unadjusted logistic regression, following factors were associated SSI: trauma etiology related to car and bicycle accidents, Müller AO classification of the fracture morphology groups 2 or 3, previous use of external fixator, surgeries with larger length of time, presence of drains, use of negative pressure therapy and need for muscle or skin flap repair. In the multiple logistic regression-adjusted analysis, previous use of external fixator and need for muscle or skin flap repair remained associated with SSI. CONCLUSIONS: Incidence of SSI associated with IN for femoral and tibial diaphyseal fractures was 11.8%. Previous use of external fixators and need for muscle or skin flap repair were factors associated with occurrence of infection
4

Incidência e fatores associados à ocorrência de infecção de sítio cirúrgico nas fraturas diafisárias do fêmur e da tíbia tratadas com haste intramedular: estudo prospectivo / Incidence and factors associated with the occurrence of surgical site infection in femoral and tibial diaphyseal fractures treated with intramedullary nailing: prospective study

Priscila Rosalba Domingos de Oliveira 27 June 2018 (has links)
INTRODUÇÃO: As fraturas diafisárias do fêmur e da tíbia encontram-se em destaque devido a sua elevada incidência e alto impacto econômico e social. A osteossíntese com uso da haste intramedular (HIM) é o procedimento cirúrgico de escolha. A infecção de sítio cirúrgico (ISC) relacionada a HIM é considerada uma complicação grave e de difícil tratamento. OBJETIVOS: 1. Determinar a incidência de ISC após a implantação de HIM para fixação de fraturas diafisárias de fêmur e tíbia. 2. Avaliar os possíveis fatores associados. MÉTODOS: Estudo prospectivo observacional do tipo coorte. Para definição de ISC, foram utilizados os critérios do CDC-NHSN. A incidência de ISC foi calculada como a relação entre o número de pacientes com ISC em relação ao número total de pacientes. Para avaliação dos potenciais fatores associados, foram analisados aqueles relacionados aos pacientes (idade, gênero, índice de massa corpórea, presença de focos ativos de infecção à distância, presença condições imunossupressoras, avaliação de estado físico segundo escore ASA, etilismo, tabagismo, uso de drogas ilícitas, politrauma, etiologia do trauma, tipo de fratura quanto à exposição óssea, classificação da fratura segundo Müller AO, classificação segundo Tcherne para as fraturas fechadas, classificação segundo Gustilo-Anderson para as fraturas expostas, permanência em outro serviço de saúde, uso prévio de fixador externo, antecedente de manipulação cirúrgica na topografia da fratura, uso de hemoderivados); dos fatores relacionados ao ambiente cirúrgico e ao ato operatório (classificação da ferida quanto ao potencial de contaminação, duração da cirurgia, tricotomia, possível contaminação intraoperatória, uso de antimicrobianos relacionados ao procedimento cirúrgico, uso de drenos, ocorrência de hipotermia ou hipóxia no período perioperatório, tipo de HIM utilizada, fresagem, necessidade de necessidade de reparo do revestimento cutâneo associado à topografia da fratura, uso de terapia por pressão negativa) e dos fatores relacionados à microbiota (colonização por S. aureus ou A. baumannii). RESULTADOS: 221 pacientes foram incluídos e completaram o período de 12 meses de seguimento. A incidência de ISC associada à osteossíntese com HIM foi de 11,8%. Na análise inicial por regressão logística não ajustada, os seguintes fatores apresentaram associação com ISC: etiologia do trauma relacionada a acidentes de carro e bicicleta, classificação Müller AO do traço da fratura 2 ou 3, uso prévio de fixador externo, cirurgias com maiores tempos de duração, uso de drenos, uso de terapia por pressão negativa e necessidade de reparo do revestimento cutâneo na topografia da fratura. Na análise ajustada por regressão logística múltipla, contudo, apenas o uso prévio de fixador externo e a necessidade de reparo do revestimento cutâneo mantiveram-se associados à ocorrência de ISC. CONCLUSÕES: A incidência de ISC associada à fixação de fraturas diafisárias de fêmur e tíbia com HIM foi de 11,8%. O uso prévio de fixadores externos e a necessidade de reparo do revestimento cutâneo na topografia da fratura foram fatores associados à ocorrência de infecção / BACKGROUND: Diaphyseal fractures of femur and tibia are prominent due to its high incidence and high economic and social impact. Intramedullary nailing (IN) is the surgical procedure of choice. Surgical site infection (SSI) related to this procedure is considered a difficult to treat complication. OBJECTIVES: Determine the incidence of SSI after IM in femoral and tibial diaphyseal fractures and evaluate possible risk factors. METHODS: Prospective observational cohort study. SSI was defined according to CDC-NHSN criteria. Incidence of SSI was calculated as the ratio between the number of patients with SSI and total number of patients. Analysis of potential risk factors included patients-related factors (age, gender, body mass index, active foci of infection, immunosuppressive conditions, ASA score, alcohol or illicit drug abuse, smoking, polytrauma, etiology of fracture, type of fracture if closed or open, classification of fracture according to Müller AO, Tcherne classification for closed fractures, to Gustilo-Anderson classification for open fractures, previous surgical manipulation, use of blood products); environmental and surgical-related factors (surgical wound classification, duration of surgery, hair removal, intraoperative contamination, antimicrobial use, presence of drains, hypothermia or hypoxia in the perioperative period, type of IN used, reaming, need for muscle or skin flap repair, use of negative pressure therapy) and microbiotarelated factors (S. aureus and A. baumannii colonization). RESULTS: 221 patients were included and completed the 12-month follow-up period. Incidence of SSI was 11.8%. In the initial analysis by unadjusted logistic regression, following factors were associated SSI: trauma etiology related to car and bicycle accidents, Müller AO classification of the fracture morphology groups 2 or 3, previous use of external fixator, surgeries with larger length of time, presence of drains, use of negative pressure therapy and need for muscle or skin flap repair. In the multiple logistic regression-adjusted analysis, previous use of external fixator and need for muscle or skin flap repair remained associated with SSI. CONCLUSIONS: Incidence of SSI associated with IN for femoral and tibial diaphyseal fractures was 11.8%. Previous use of external fixators and need for muscle or skin flap repair were factors associated with occurrence of infection

Page generated in 0.0697 seconds