Spelling suggestions: "subject:"friction compensation"" "subject:"friction eompensation""
31 |
Contribution to the design of control laws for bilateral teleoperation with a view to applications in minimally invasive surgeryDelwiche, Thomas 09 December 2009 (has links)
Teleoperation systems have been used in the operating rooms for more than a decade. However, the lack of force feedback in commercially available systems still raises safety issues and forbids surgical gestures like palpation. Although force feedback has already been implemented in experimental setups, a systematic methodology is still lacking to design the control laws.<p><p>The approach developed in this thesis is a contribution towards such a systematic<p>methodology: it combines the use of disturbance observers with the use of a structured fixed-order controller. This approach is validated by experiments performed on a one degree of freedom teleoperation system. A physical model of this system is proposed and validated experimentally.<p><p>Disturbance observers allow to compensate friction, which is responsible for performance degradation in teleoperation. Contrary to alternative approaches,they are based on a model of the frictionless mechanical system. This allows to compensate friction with a time varying behavior, which occurs in laparoscopy.<p><p>Parametric uncertainties in this model may lead to an unstable closed-loop. A kind of "separation principle" is provided to decouple the design of the closed-loop system from the design of the observer. It relies on a modified problem statement and on the use of available robust design and analysis tools.<p><p>A new metric is proposed to evaluate the performance of friction compensation systems experimentally. This metric evaluates the ability of a compensation system to linearize a motion system, irrespective of the task and as a function of frequency. The observer-based friction compensation is evaluated with respect to this new metric and to a task-based metric. It correctly attenuates the friction in the bandwidth of interest and significantly improves position and force tracking during a palpation task.<p><p>Structured fixed-order controllers are optimized numerically to achieve robust closed-loop performance despite modeling uncertainty. The structure is chosen among classical teleoperation structures. An efficient algorithm is selected and implemented to design such a controller, which is evaluated for a palpation task. It is compared to a full-order unstructured controller, representative of the design approach that has been used in the teleoperation literature up to now. The comparison highlights the advantages of our new approach: order-reduction steps and counter-intuitive behaviors are avoided. <p><p>A structured fixed-order controller combined with a disturbance observer is implemented during a needle insertion experiment and allowed to obtain excellent performance. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
|
32 |
Ansätze zur entkoppelten Regelung von mechanisch gekoppelten Doppelgelenken eines DLR-MedizinrobotersLe-Tien, Luc 13 July 2010 (has links)
In dieser Arbeit werden die Methoden zur Modellierung, Identifikation, Regelung und Reibungskompensation von DLR-Medizinrobotern mit elastischen und differentiell getriebenen Gelenken vorgestellt. In der Praxis zeigt sich, dass bei den DLR-Medizinrobotern sowohl die Gelenkelastizität als auch die Gelenkverkopplung innerhalb des Doppelgelenks in der Modellierung und Regelung berücksichtigt werden muss. Daher ist es das Hauptziel dieser Arbeit, eine Regelungsstruktur zu entwickeln, die das gewünschte Folge- und Einschwingverhalten erreicht. Zur Regelung wird mit Hilfe der modalen Entkopplung ein MIMO – Zustandsregler für die Doppelgelenkstruktur eingeführt, der auf der Rückführung der antriebsseitigen Positionen und abtriebsseitigen Drehmomente sowie deren Ableitungen basiert. Für die medizinischen Anwendungen spielt die Positionsgenauigkeit, die durch die hohe Reibung stark beeinflusst wird, eine entscheidende Rolle. Um die Positioniergenauigkeit des Roboters zu verbessern, wird ein Reibungsbeobachter entwickelt, der eine passive Reibungskompensation ermöglicht. Da der Reibungsbeobachter nur den Momentenfehler, nicht aber den Positionsfehler integriert, wird diese Kompensation außer zur Positionsregelung auch zur Verbesserung der Qualität der Drehmoment- und Impedanzregelung eingesetzt. Für die gesamte Regelungsstruktur aus Zustandsregler und Reibungsbeobachter wird global asymptotische Stabilität des gesamten nichtlinearen Roboters nachgewiesen. Diese Regelungsstruktur wird derzeit in zahlreichen Anwendungen mit den DLR-Medizinrobotern benutzt und validiert.
|
Page generated in 0.1295 seconds