• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Transferencia de calor em sistemas liquidos/particulados envasados sob alto vacuo

Schmidt, Flávio Luís, 1967- 27 July 2018 (has links)
Orientador: Alfredo de Almeida Vitali / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-27T08:47:24Z (GMT). No. of bitstreams: 1 Schmidt_FlavioLuis_D.pdf: 27091958 bytes, checksum: 82ce0e0edc4da73190d61eec04fc4ccb (MD5) Previous issue date: 2000 / Resumo: Alimentos tipo "solid pack" são conhecidos como aqueles produtos particulados enlatados sob alto vácuo (25 pol Hg) processados termicamente, contendo aproximadamente 10% de líquido em relação ao volume da embalagem. Apesar desta tecnologia ser conhecida desde 1970, há relativamente poucos estudos a respeito do fenômeno de transferência de calor e sobre o uso de vapor ou água com sobrepressão de vapor como meio de aquecimento para este processo. Um sistema para a rotação tipo extremidade sobre extremidade das latas foi adaptado numa cuba acrílica. Esferas de polietileno de 11 mm de diâmetro foram utilizadas como simulantes de alimentos e testes de penetração de calor foram conduzidos em latas (73x95)mm, completamente cheias com as esferas, recravadas sob vácuo de O, 12,5 e 25 pol Hg; volumes livres de 23 e 38%, e velocidade de rotação de O,16 e 32 rpm. Termopares foram fixados ao longo da extensão das latas, perfazendo o perfil de temperatura nos processo. Testes em escala piloto realizados em autoclaves também foram executados e a temperatura no centro das esferas foi medida e comparada com valores estimados pelo método da função de transferência em z, com intuito de validar este método de predição. Os resultados demonstraram a influência do vácuo no tempo de processo, sendo os processos térmicos mais longos na ausência de vácuo, principalmente com 38% de volume-livre. Os pontos de aquecimento mais lento e mais rápido estiveram localizados, respectivamente, a 1/2 (maioria) e 1/5 da altura da lata, nos processos estáticos. O ponto de aquecimento mais lento nos alimentos enlatados tipo "solid pack" pode ser diferente dos alimentos convencionais, principalmente no caso de processamento estático. É essencial controlar o vácuo de recravação o qual deve ser considerado com ponto crítico de controle. A agitação incrementou os coeficientes de transferência de calor, observados pelo reduzido tempo de processo. O uso das funçôes de transferência em z demonstrou uma boa resolução e poderia ser utilizado para predição da temperatura das esferas e facilitar a obtenção de coeficientes de transferência de calor. / Abstract: Solid pack foods are known as those particulated heat processed canned product, closed under high vacuum (25 Hg inch) and containing aproximately 10% of the packadge volume in liquid. In spite of this technology is known since 1970, there are relatively few studies conceming on the heat transfer phenomena and the use of steam as heating medium. The objective of this work was to understand the heat transfer phenomena inside the can and some of the variables that affect the solid pack processo A controlled system for the end-over-end rotation of cans was adapted in a acrilic vessel. Poliethylene spheres (11 mm diameter) were used as simulant of foods and heat penetration tests were carried out in (73x95)mm cans, completely filled with the spheres, with closure vacuum of O, 12,5 and 25 in Hg; free volume of 23 and 38%, and rotation speed of O, 16 and 32 rpm. Thermocouples were fixed along the axis of the cans, showing the temperature profiles. Pilot tests were also performed in a retort and for these tests, the center temperature of the spheres was experimentaly determined and checked out with the theoretical z-transfer function method with the purpose of validate it. Results showed the influence of vacuum on the process time, mainly those at 38% free volume, being the thermal process longer at lower vaccum. The slowest and fastest heating points were located respectivelyat 1/2 (or 2/3) and 1/5 can height on the static tests. The slowest heating point in solid pack type canned foods may be different from those conventional convective products, mainly if static process takes place. It is essential to control the vaccum closure that was considered a critical control point. Agitation improved the heat transfer coefficients, observed by reduced process time. The z-transfer function method showed good performance and could be used for sphere temperature prediction and heat transfer coefficients determination. / Doutorado / Doutor em Ciência de Alimentos
2

Avaliação automatica de parametros fisicos de qualidade de imagem em sistemas de radiologia digital odontologica

Albuquerque, Jorge Andre Girão 29 July 2018 (has links)
Orientador : Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-29T02:59:46Z (GMT). No. of bitstreams: 1 Albuquerque_JorgeAndreGirao_M.pdf: 5796408 bytes, checksum: 09bd57e0a31a84f22f0e6c4d5ab05252 (MD5) Previous issue date: 2001 / Mestrado
3

Sistema de avaliação de qualidade de imagem em radiologia digital odontologica / Image quality evaluation system for dental digital radiology

Leão, Tiago Freire Carneiro 13 August 2018 (has links)
Orientador: Eduardo Tavares Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-13T16:14:16Z (GMT). No. of bitstreams: 1 Leao_TiagoFreireCarneiro_M.pdf: 2505362 bytes, checksum: 6d6b07198f62fd7206b28e629cc5ba41 (MD5) Previous issue date: 2009 / Resumo: Novas tecnologias e sistemas de detecção de radiação para a geração de imagens radiográficas odontológicas vêm sendo disponibilizados como alternativa aos filmes radiográficos. Sistemas baseados em tecnologia do tipo PSPL parecem superar algumas das restrições encontradas nos sistemas baseados em tecnologia CCD, tais como volume do detector, cabos de conexão, tamanho limitado da imagem e limitação da latitude. É importante que seja possível comparar sistemas de imagem concorrentes (diferentes tecnologias ou diferentes fabricantes com mesma tecnologia), utilizando ferramentas e protocolos de controle e certificação de qualidade. Foi desenvolvido um pacote computacional e um conjunto de simuladores e foi realizada a análise de dois sistemas comerciais baseados na tecnologia PSPL, de forma a validar o sistema desenvolvido. O programa desenvolvido permite obter e analisar: curva sensitométrica, função de transferência de modulação (MTF), densidade espectral de potência (NPS), quanta equivalente de ruído (NEQ) e eficiência na detecção de quanta (DQE). Os resultados mostraram que o pacote computacional e o conjunto de simuladores permitem realizar o controle de qualidade de sistemas de radiografia digital odontológica de maneira quantitativa e objetiva, facilitando a análise comparativa entre diferentes sistemas comerciais. Palavras-chave: Radiologia digital odontológica, controle de qualidade em radiodiagnóstico, curva sensitométrica, detecção equivalente de quanta, função de transferência de modulação, densidade espectral de ruído, quanta equivalente de ruído. / Abstract: New systems and technologies for radiation detection intended for dental radiology have become available as an alternative to dental radiographic film. Systems based on PSPL technology seems to overcome some of the restrictions of systems based on CCD technology such as the bulky detector, connecting wire, limited image size and limited exposure latitude. It is important that competing imaging systems can be compared (different technologies or different manufacturers of the same technology) by means of quality control tools and quality certification protocols. A software package and a set of specific phantoms were developed and the analyses of two competing PSPL systems were conducted to validate the developed system. The software allows the user to obtain and analyze: the characteristic curve, modulation transfer function (MTF), noise power spectrum (NPS), noise equivalent quanta (NEQ) and detective quantum efficiency (DQE). The results have shown that the developed software and phantom set allow quality control of digital dental radiology systems in a very objective and quantitative way, facilitating comparative analysis of competing commercial systems. Keywords: Digital dental radiology, quality assurance in radiodiagnostic, characteristic curve, detective quantum efficiency, modulation transfer function, noise power spectrum, noise equivalent quanta. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica

Page generated in 0.1028 seconds