• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • Tagged with
  • 34
  • 34
  • 26
  • 26
  • 13
  • 12
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Determinação do comportamento carga-recalque de sapatas em solos residuais a partir de ensaios SPT

Ruver, Cesar Alberto January 2005 (has links)
O comportamento carga-recalque de sapatas assentes em solos residuais é perfeitamente representado a partir da interpretação de provas de carga. No entanto, a execução de provas de carga em fundações reais ou em placa é indesejada pela maioria dos construtores e contratantes por razões de cronograma e custo. Por outro lado, sondagens de simples reconhecimento (SPT) são de rápida execução, exigidas pela normalização vigente de projeto e execução de fundações (ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS, 1996) e largamente utilizados na geotecnia nacional, sendo tal ensaio normalizado pela da norma NBR 6.484/2001. Deste modo, nesta pesquisa, pretende-se estabelecer uma metodologia semi-empírica para estimar o comportamento de sapatas assentes em solos residuais a partir de correlação estatística de resultados de sondagens de simples reconhecimento (NSPT) com a tensão admissível e os recalques sob tensão de trabalho, obtidos a partir de resultados de provas de carga em placa ou fundações reais assentes em solos residuais. Deste modo, a partir de retro-análise de um conjunto de resultados de provas de carga executados em diferentes solos residuais, encontrados na literatura, e o uso de conceitos de estatística, obteve-se diversas correlações que possibilitam estimar o comportamento tensão-recalque deste tipo de solo através dos resultados médios dos ensaios de SPT Como resultados destas correlações foram obtidas equações para a previsão de recalques e tensão admissível de fundações assentes sobre solos residuais, bem como do módulo de elasticidade de tais solos. As equações de estimativa de recalques são dependentes, além dos resultados de SPT, da geometria da fundação e da tensão aplicada. Já as equações para a estimativa da tensão admissível e módulo de elasticidade são dependentes somente dos valores médios do ensaio de SPT. E finalmente, para testar as equações desenvolvidas, foi realizada uma análise “Classe A” no comportamento carga-recalque de três provas de carga realizadas em locais diferentes, mostrando a eficiência da metodologia desenvolvida para a determinação da tensão admissível e dos recalques em sapatas sob a aplicação de carga de trabalho assentes em solos residuais.
22

Interação solo-estrutura para edifícios de concreto armado sobre fundações diretas / Soil-structure interaction for reinforced concrete buildings on shallow foundations

Holanda Júnior, Osvaldo Gomes de 21 August 1998 (has links)
Interação solo-estrutura é o objeto de estudo deste trabalho. O principal objetivo é verificar a verdadeira importância desse fenômeno na análise estrutural de edifícios usuais em concreto armado sobre fundações diretas. Inicialmente apresenta-se um estudo sobre o comportamento do solo. Logo após são descritos os processos de dimensionamento de fundações superficiais, com base na NBR 6122 (1996). Descrevem-se em seguida os elementos barra e sapata rígida, utilizados na modelagem do sistema superestrutura-subestrutura-maciço de solos. Discute-se a modificação do elemento sapata rígida, que representa fundação e solo, para a consideração de uma camada indeslocável no interior do solo. De acordo com a teoria apresentada, dois exemplos são submetidos a duas análises, com ou sem a consideração da interação sol-estrutura, para que os resultados sejam comparados. Aplicam-se separadamente as ações verticais e horizontais. A influência duma camada indeslocável no interior do solo e os efeitos da seqüência construtiva dos edifícios também são analisados. / Soil-structure interaction is the subject of this work. The foremost aim is to verify the real importance of that phenomenon on the structural analysis of usual reinforced concrete buildings on shallow foundations. At first, it is presented a study of soil behaviour. Design procedures of shallow foundations based on NBR 6122 (1996) are described afterwards. Then, the beam and rigid footing elements, used for modelling the superstructure-infrastructure-foundation soil system, are described. It is discussed the modification of the rigid footing element, which represents foundation and soil, to consider a rigid layer within soil. According to the theory above presented, two examples are subjected to two analysis, with or without the consideration of soil-structure interaction, in order to compare the results. Vertical and horizontal loads are separately applied. The influence of a rigid layer within soil and the effects of the sequence of buildings construction are also analysed.
23

Novo método para cálculo da capacidade de carga de fundações superficiais assentes sobre camada de reforço em solo cimento / New Method for Calculating Bearing Capacity of Footings Resting on Soil- Cement Layers

Foppa, Diego January 2016 (has links)
Pesquisas recentes têm mostrado que a utilização de camada de reforço em solo-cimento é uma alternativa para o aumento da capacidade de carga e redução dos recalques de fundações superficiais em solos de baixa resistência. Os métodos para previsão da capacidade de carga em sistemas de dupla camada encontrados na literatura trazem implícita a premissa de que a camada superior é contínua ou suficientemente maior que a largura da fundação. O objetivo desta pesquisa foi desenvolver um novo método para o cálculo de capacidade de carga de fundações superficiais assentes sobre uma camada de reforço em solo-cimento, considerando sua extensão lateral. Para tanto, foram realizados ensaios em modelos reduzidos de fundações contínuas assentes sobre um solo arenoso fofo, bem como, análises numéricas através do método dos elementos finitos. Observaram-se dois tipos distintos de ruptura. No primeiro, a camada de reforço é puncionada para dentro do solo natural, sem apresentar fissuras, até o deslocamento correspondente à capacidade de carga do solo natural No segundo, após um recalque inicial, a camada de reforço rompe com o aparecimento de uma fissura, que pode localizar-se junto à borda ou no eixo da fundação, e se propaga de baixo para cima, à medida que aumentam os recalques. Verificou-se que a máxima tensão de tração na camada de reforço é função da reação do solo na base do reforço e da relação Tr/Hr, onde Tr é a distância horizontal entre a borda da fundação e a borda do reforço e Hr é a espessura do reforço. A partir destas observações, foi desenvolvido um novo método de cálculo com a premissa de que a ruptura ocorra no solo e não na camada de reforço. Assim, é possível calcular a capacidade de carga considerando que fundação e reforço atuam como um elemento único, apoiado na mesma profundidade de assentamento do reforço. Ao mesmo tempo, é apresentada uma equação para previsão da máxima tensão de tração que atuará no reforço, a partir da qual, se pode dimensioná-lo com segurança. / Recent researches have shown that the use of soil-cement reinforcement layer is an alternative to increase bearing capacity and reduce settlements of shallow foundations in low resistance soils. The existing methods for predicting bearing capacity of double layer systems implicitly assume that the top layer is continuous or sufficiently greater than the foundation width. This study aims to develop a new method for bearing capacity calculation of shallow foundations supported by a soil-cement reinforcing layer, considering its lateral extension. Therefore, small scale tests of continuous foundations on a loose sandy soil, as well as, numerical analysis by the finite element method were carried out. It was observed two distinct types of failure. In the first, the reinforcement layer is punched through the sandy soil, without showing any cracking, up to a settlement which corresponds to the sand bearing capacity. In the second, after an initial settlement, the reinforcement layer breaks up, showing a fissure, which may be located near the edge or the axis of foundation, and propagates upward as the settlements continues. It was found that the maximum tensile stress in the reinforcement layer is a function of soil reaction on the reinforcement and the ratio Tr/Hr, where Tr is the horizontal distance between the edge of the foundation and the edge soil-cement layer and Hr is the thickness of the soil-cement layer. From these observations, it was developed a new calculation method, with the assumption that the failure occurs in the soil and not in the reinforcement layer. Thus, it is possible to calculate the bearing capacity considering that foundation and reinforcement act as a single element, supported at the same depth of the reinforcement base. In order to design the soil-cement layer, an equation for the maximum tensile stress prediction is provided.
24

INTERAÇÃO SOLO-ESTRUTURA DE EDIFÍCIOS COM FUNDAÇÕES SUPERFICIAIS / SOIL-STRUCTURE INTERACTION OF BUILDINGS ON SHALLOW FOUNDATIONS

Antoniazzi, Juliana Pippi 22 July 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work deals with the consideration of Soil-Structure Interaction (SSI) in structural design of reinforced concrete buildings on shallow foundations of the isolated footing type. It carried out a comprehensive review on the major works done in the area and the methods for obtaining parameters and variables involved in the analysis. Numerical examples were developed with the aim of identifying internal forces and displacements changes caused by considering the deformation of soil and the construction sequence in the structural analysis. The examples also intended to show data and procedures for the required calculations in the consideration of the SSI in structural designs. Among the computational tools used in the numerical examples is ESPACIAL_ISE program - a program developed in FORTRAN by Alva (2010). This program employs the method of Aoki and Lopes (1975), which uses the equations of Mindlin (1936) for calculating the settlements, together with the Steinbrenner´s method (1934) to consider the stratigraphy of the soil mass. It was also used in the numerical examples SISEs computer system (System of Soil-Structure Interaction) - developed by TQS Informatics - which allows that the entire structure and foundation are represented in a single structural model. The results of this study showed the importance of considering the soil deformation, although in a simplified form, replacing the fixed support hypothesis in structural designs. Thus, for a more realistic structural analysis of multistory buildings, it is recommended that the soil-structure interaction is considered together with the construction sequence. / O presente trabalho trata da consideração da Interação Solo-Estrutura (ISE) em projetos estruturais de edifícios em concreto armado sobre fundações superficiais do tipo sapatas isoladas. É realizada uma ampla revisão bibliográfica sobre os principais trabalhos desenvolvidos na área e sobre os métodos para a obtenção de parâmetros e variáveis envolvidos na análise. Exemplos numéricos foram desenvolvidos com o intuito de identificar as alterações de esforços e deslocamentos ocasionadas ao se considerar a deformabilidade do solo e a sequência construtiva na análise estrutural. Os exemplos também tiveram como objetivo mostrar os dados e os procedimentos de cálculo necessários para a consideração da ISE em projetos estruturais. Entre as ferramentas computacionais utilizadas nos exemplos numéricos está o programa ESPACIAL_ISE - programa desenvolvido em linguagem FORTRAN por Alva (2010). O referido programa emprega o método de Aoki e Lopes (1975), o qual utiliza as equações de Mindlin (1936) para o cálculo dos recalques, em conjunto com o procedimento de Steinbrenner (1934) para considerar a estratigrafia do maciço de solos. Também foi utilizado nos exemplos numéricos o sistema computacional SISEs (Sistema de Interação Solo-Estrutura) desenvolvido pela TQS Informática - o qual permite que toda a estrutura e a fundação sejam representadas em um modelo estrutural único. Os resultados obtidos neste trabalho mostraram a importância da consideração da deformabilidade do solo, ainda que de forma simplificada, em substituição à hipótese de apoios indeslocáveis nos projetos estruturais. Para uma análise estrutural mais realista em edifícios de múltiplos andares, recomenda-se que a interação solo-estrutura seja considerada juntamente com a sequência construtiva.
25

Novo método para cálculo da capacidade de carga de fundações superficiais assentes sobre camada de reforço em solo cimento / New Method for Calculating Bearing Capacity of Footings Resting on Soil- Cement Layers

Foppa, Diego January 2016 (has links)
Pesquisas recentes têm mostrado que a utilização de camada de reforço em solo-cimento é uma alternativa para o aumento da capacidade de carga e redução dos recalques de fundações superficiais em solos de baixa resistência. Os métodos para previsão da capacidade de carga em sistemas de dupla camada encontrados na literatura trazem implícita a premissa de que a camada superior é contínua ou suficientemente maior que a largura da fundação. O objetivo desta pesquisa foi desenvolver um novo método para o cálculo de capacidade de carga de fundações superficiais assentes sobre uma camada de reforço em solo-cimento, considerando sua extensão lateral. Para tanto, foram realizados ensaios em modelos reduzidos de fundações contínuas assentes sobre um solo arenoso fofo, bem como, análises numéricas através do método dos elementos finitos. Observaram-se dois tipos distintos de ruptura. No primeiro, a camada de reforço é puncionada para dentro do solo natural, sem apresentar fissuras, até o deslocamento correspondente à capacidade de carga do solo natural No segundo, após um recalque inicial, a camada de reforço rompe com o aparecimento de uma fissura, que pode localizar-se junto à borda ou no eixo da fundação, e se propaga de baixo para cima, à medida que aumentam os recalques. Verificou-se que a máxima tensão de tração na camada de reforço é função da reação do solo na base do reforço e da relação Tr/Hr, onde Tr é a distância horizontal entre a borda da fundação e a borda do reforço e Hr é a espessura do reforço. A partir destas observações, foi desenvolvido um novo método de cálculo com a premissa de que a ruptura ocorra no solo e não na camada de reforço. Assim, é possível calcular a capacidade de carga considerando que fundação e reforço atuam como um elemento único, apoiado na mesma profundidade de assentamento do reforço. Ao mesmo tempo, é apresentada uma equação para previsão da máxima tensão de tração que atuará no reforço, a partir da qual, se pode dimensioná-lo com segurança. / Recent researches have shown that the use of soil-cement reinforcement layer is an alternative to increase bearing capacity and reduce settlements of shallow foundations in low resistance soils. The existing methods for predicting bearing capacity of double layer systems implicitly assume that the top layer is continuous or sufficiently greater than the foundation width. This study aims to develop a new method for bearing capacity calculation of shallow foundations supported by a soil-cement reinforcing layer, considering its lateral extension. Therefore, small scale tests of continuous foundations on a loose sandy soil, as well as, numerical analysis by the finite element method were carried out. It was observed two distinct types of failure. In the first, the reinforcement layer is punched through the sandy soil, without showing any cracking, up to a settlement which corresponds to the sand bearing capacity. In the second, after an initial settlement, the reinforcement layer breaks up, showing a fissure, which may be located near the edge or the axis of foundation, and propagates upward as the settlements continues. It was found that the maximum tensile stress in the reinforcement layer is a function of soil reaction on the reinforcement and the ratio Tr/Hr, where Tr is the horizontal distance between the edge of the foundation and the edge soil-cement layer and Hr is the thickness of the soil-cement layer. From these observations, it was developed a new calculation method, with the assumption that the failure occurs in the soil and not in the reinforcement layer. Thus, it is possible to calculate the bearing capacity considering that foundation and reinforcement act as a single element, supported at the same depth of the reinforcement base. In order to design the soil-cement layer, an equation for the maximum tensile stress prediction is provided.
26

ESTUDO DO COMPORTAMENTO DE SOLOS ATRAVÉS DE ENSAIOS DE PLACA DE DIFERENTES DIÂMETROS / STUDY ON SOIL BEHAVIOR THROUGH PLATE LOAD TESTS WITH DIFFERENT DIAMETERS

Russi, Daniel 15 June 2007 (has links)
The dimensioning of shallow foundations requires the professional to define clearly and objectively, for the soil in question, the load capacity and forecast the settlings of the foundation submitted to the structure having as base its mechanical properties obtained through field and/or laboratory investigation. One of the safest ways to take this decision is based on information from plate load tests because through this it is possible to reproduce in a minor proportion the real behavior of the future foundation, perhaps using this as a tool to help in the decision making to dimension shallow foundations, contributing to a more efficient development of the foundation work. The present work is about the analysis of the CEEG/UFSM soil behavior through tests on direct load proof on foundation field (plate load test). The research is divided, basically into two great phases. There was an experimental phase which comprehended geotechnical characterization trials and plate load tests to evaluate the behavior tension-settling of foundation. There were 7 plate load tests in 3 ditches dug manually up to 0,7 m depth. Plates with 15, 30 and 50 cm diameter were used and the reaction system was formed by reaction piles united by a reaction beam. The second phase was the analysis of the results obtained, analyzed through curves tension-settling of foundation, where some criteria were applied to define the rupture tension and some considerations were done on the settling of foundation forecast and scale effect. / O dimensionamento de fundações superficiais requer que o profissional defina de forma clara e objetiva, para o solo em questão, a capacidade de carga e a previsão dos recalques que se submete à estrutura, baseando-se em suas propriedades mecânicas obtidas em investigações de campo e/ou laboratório. Uma das formas mais seguras de se tomar essa decisão está baseada nas informações advindas do ensaio de carregamento direto sobre placas, pois, através dele, se reproduz em escala reduzida o comportamento real da futura fundação, podendo servir como ferramenta de auxílio na tomada de decisão para o dimensionamento de fundações superficiais, contribuindo para o desenvolvimento mais eficaz das obras de fundação. O presente trabalho trata da análise do comportamento do solo do CEEG/UFSM através do ensaio de prova de carga direta sobre terreno de fundação (ensaio de placa). A pesquisa dividiu-se basicamente em duas grandes etapas. Uma etapa experimental, a qual compreendeu ensaios de caracterização geotécnica e ensaios de placa para a avaliação do comportamento tensão-recalque. Realizou-se 7 ensaios de placa em três trincheiras escavadas manualmente até a profundidade de 0,7 metros. Utilizou-se placas de 15, 30 e 50 cm de diâmetro e o sistema de reação compreendia estacas de reação unidas por uma viga de reação. A segunda etapa consistiu na análise dos resultados obtidos, analisados através de curvas tensão-recalque, as quais se aplicaram alguns critérios para definir a tensão de ruptura e fez-se algumas considerações sobre a previsão de recalques e o efeito escala.
27

Novo método para cálculo da capacidade de carga de fundações superficiais assentes sobre camada de reforço em solo cimento / New Method for Calculating Bearing Capacity of Footings Resting on Soil- Cement Layers

Foppa, Diego January 2016 (has links)
Pesquisas recentes têm mostrado que a utilização de camada de reforço em solo-cimento é uma alternativa para o aumento da capacidade de carga e redução dos recalques de fundações superficiais em solos de baixa resistência. Os métodos para previsão da capacidade de carga em sistemas de dupla camada encontrados na literatura trazem implícita a premissa de que a camada superior é contínua ou suficientemente maior que a largura da fundação. O objetivo desta pesquisa foi desenvolver um novo método para o cálculo de capacidade de carga de fundações superficiais assentes sobre uma camada de reforço em solo-cimento, considerando sua extensão lateral. Para tanto, foram realizados ensaios em modelos reduzidos de fundações contínuas assentes sobre um solo arenoso fofo, bem como, análises numéricas através do método dos elementos finitos. Observaram-se dois tipos distintos de ruptura. No primeiro, a camada de reforço é puncionada para dentro do solo natural, sem apresentar fissuras, até o deslocamento correspondente à capacidade de carga do solo natural No segundo, após um recalque inicial, a camada de reforço rompe com o aparecimento de uma fissura, que pode localizar-se junto à borda ou no eixo da fundação, e se propaga de baixo para cima, à medida que aumentam os recalques. Verificou-se que a máxima tensão de tração na camada de reforço é função da reação do solo na base do reforço e da relação Tr/Hr, onde Tr é a distância horizontal entre a borda da fundação e a borda do reforço e Hr é a espessura do reforço. A partir destas observações, foi desenvolvido um novo método de cálculo com a premissa de que a ruptura ocorra no solo e não na camada de reforço. Assim, é possível calcular a capacidade de carga considerando que fundação e reforço atuam como um elemento único, apoiado na mesma profundidade de assentamento do reforço. Ao mesmo tempo, é apresentada uma equação para previsão da máxima tensão de tração que atuará no reforço, a partir da qual, se pode dimensioná-lo com segurança. / Recent researches have shown that the use of soil-cement reinforcement layer is an alternative to increase bearing capacity and reduce settlements of shallow foundations in low resistance soils. The existing methods for predicting bearing capacity of double layer systems implicitly assume that the top layer is continuous or sufficiently greater than the foundation width. This study aims to develop a new method for bearing capacity calculation of shallow foundations supported by a soil-cement reinforcing layer, considering its lateral extension. Therefore, small scale tests of continuous foundations on a loose sandy soil, as well as, numerical analysis by the finite element method were carried out. It was observed two distinct types of failure. In the first, the reinforcement layer is punched through the sandy soil, without showing any cracking, up to a settlement which corresponds to the sand bearing capacity. In the second, after an initial settlement, the reinforcement layer breaks up, showing a fissure, which may be located near the edge or the axis of foundation, and propagates upward as the settlements continues. It was found that the maximum tensile stress in the reinforcement layer is a function of soil reaction on the reinforcement and the ratio Tr/Hr, where Tr is the horizontal distance between the edge of the foundation and the edge soil-cement layer and Hr is the thickness of the soil-cement layer. From these observations, it was developed a new calculation method, with the assumption that the failure occurs in the soil and not in the reinforcement layer. Thus, it is possible to calculate the bearing capacity considering that foundation and reinforcement act as a single element, supported at the same depth of the reinforcement base. In order to design the soil-cement layer, an equation for the maximum tensile stress prediction is provided.
28

Interação solo-estrutura para edifícios de concreto armado sobre fundações diretas / Soil-structure interaction for reinforced concrete buildings on shallow foundations

Osvaldo Gomes de Holanda Júnior 21 August 1998 (has links)
Interação solo-estrutura é o objeto de estudo deste trabalho. O principal objetivo é verificar a verdadeira importância desse fenômeno na análise estrutural de edifícios usuais em concreto armado sobre fundações diretas. Inicialmente apresenta-se um estudo sobre o comportamento do solo. Logo após são descritos os processos de dimensionamento de fundações superficiais, com base na NBR 6122 (1996). Descrevem-se em seguida os elementos barra e sapata rígida, utilizados na modelagem do sistema superestrutura-subestrutura-maciço de solos. Discute-se a modificação do elemento sapata rígida, que representa fundação e solo, para a consideração de uma camada indeslocável no interior do solo. De acordo com a teoria apresentada, dois exemplos são submetidos a duas análises, com ou sem a consideração da interação sol-estrutura, para que os resultados sejam comparados. Aplicam-se separadamente as ações verticais e horizontais. A influência duma camada indeslocável no interior do solo e os efeitos da seqüência construtiva dos edifícios também são analisados. / Soil-structure interaction is the subject of this work. The foremost aim is to verify the real importance of that phenomenon on the structural analysis of usual reinforced concrete buildings on shallow foundations. At first, it is presented a study of soil behaviour. Design procedures of shallow foundations based on NBR 6122 (1996) are described afterwards. Then, the beam and rigid footing elements, used for modelling the superstructure-infrastructure-foundation soil system, are described. It is discussed the modification of the rigid footing element, which represents foundation and soil, to consider a rigid layer within soil. According to the theory above presented, two examples are subjected to two analysis, with or without the consideration of soil-structure interaction, in order to compare the results. Vertical and horizontal loads are separately applied. The influence of a rigid layer within soil and the effects of the sequence of buildings construction are also analysed.
29

Avaliação do efeito da interação solo estrutura sobre o comportamento estrutural de edificações em aço e mistas (aço concreto). / Evaluation of the effect of soil - structure interaction on the structural behavior of buildings in steel and composite (steel - concrete).

Flávio dos Ramos de Souza Mendonça 06 December 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O conhecimento do tema da interação solo-estrutura permite que as edificações sejam projetadas de maneira mais realista com o comportamento físico. Há décadas atrás seria inviável um dimensionamento considerando a deformabilidade do solo de fundação, e as estruturas eram dimensionadas adotando-se as fundações como indeslocáveis, sob uma base rígida. Essa consideração conduz a respostas estruturais inadequadas, por vezes comprometendo a segurança e a estabilidade do conjunto estrutural. Atualmente, o avanço tecnológico permite a obtenção de resultados de milhões de cálculos matemáticos em questões de segundos, podendo-se obter soluções mais arrojadas e dinâmicas, facilitando o dimensionamento estrutural de forma a atender ao novo padrão de construção e arquitetura. A relevância de tal assunto motivou a análise numérica de um edifício de 4 pavimentos de estrutura mista (aço-concreto), considerando o efeito da interação solo-estrutura. As análises foram conduzidas com o programa ANSYS, de elementos finitos, substituindo-se os apoios indeslocáveis por molas discretas, lineares e elásticas, com rigidez equivalente ao solo, conforme hipótese de Winkler. Os parâmetros dos solos de fundação foram adquiridos a partir de correlações empíricas existentes na literatura e da utilização do programa computacional PLAXIS para a determinação das constantes elásticas das molas. Neste trabalho, foram comparados os resultados de reações verticais, esforços normais, momentos fletores e deslocamentos da estrutura obtidos pelo modelo clássico de projeto, que considera apoios indeslocáveis, e pelo modelo de Winkler, que considera a interação solo-estrutura. As análises foram executadas para seis diferentes tipos de solos argilosos, siltosos e arenosos. Os resultados obtidos mostraram claramente a redistribuição dos momentos fletores, esforços normais e reações verticais nos pilares com diferenças significativas para os pilares de canto e periféricos. Observou-se uma tendência de alívio dos esforços nos pilares mais solicitados, adotando a estrutura assentada em uma base rígida. As análises ressaltaram a relevância da interação solo-estrutura, com efeitos provenientes do rearranjo do solo de fundação nos elementos estruturais das edificações. / Knowledge of the subject matter soilstructure interaction (SSI) allows buildings to be designed in a more realistic manner, in line with physical interactions. Decades ago, it would be unfeasible to effect measurements taking into account the deformability of foundation soil, and thus structures were measured assuming foundations as unmovable, over a rigid basis. Such a consideration leads to inadequate structural findings, often compromising the safety and stability of the structural set. At present, technological advances permit grasping the results of millions of mathematical calculations in a matter of seconds, allowing for more advanced and dynamic solutions, and facilitating structural measurements in such a way as to cater to new standards in construction and architecture. The relevance of the subject motivated the numerical analysis of a four-store building of mixed (steelconcrete) structure, considering the effects of soilstructure interaction. Analyses were undertaken with ANSYS software, with finite elements, replacing unmovable supports with linear, elastic and discrete springs, with rigidity equivalent to that of soil, as in Winklers hypothesis. The parameters of foundation soils were obtained from empirical correlations encountered in literature and from the PLAXIS computer program, used to determine the springs elastic constants. In this work, the resulting vertical reactions, normal stress, bending moments and structure displacements were compared, all of which were obtained from the classical project model, which assumes unmovable supports, and from the Winkler model, which considers soilstructure interaction. The analyses have been executed for six different kinds of clay, silt and sand soils. Results showed clearly the redistribution of bending moments, normal stress and vertical reactions on pillars, with significant differences for corner and peripheral pillars. It was observed that there is a trend to relieve efforts on most demanded pillars, when the structure is assumed to be over a rigid basis. The analyses showed the importance of soilstructure interaction, with effects originating from rearranging foundation soil over structural elements of buildings.
30

Estudo comparativo entro o SPT, a prova de carga sobre placas e o ensaio pressiométrico, aplicado a fundações superficiais em solo arenoso - resultados preliminares. / Comparative study between the SPT, the load test on plates and the pressiometric test, applied to surface foundations in sandy soil - preliminary results.

BEZERRA, Sosthemar Pedrosa. 10 November 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-11-10T13:23:14Z No. of bitstreams: 1 SOSTHEMAR PEDROSA BEZERRA - DISSERTAÇÃO PPGECA 1990..pdf: 26819503 bytes, checksum: a420d17888b6840c1a3392d4b2d31be4 (MD5) / Made available in DSpace on 2018-11-10T13:23:14Z (GMT). No. of bitstreams: 1 SOSTHEMAR PEDROSA BEZERRA - DISSERTAÇÃO PPGECA 1990..pdf: 26819503 bytes, checksum: a420d17888b6840c1a3392d4b2d31be4 (MD5) Previous issue date: 1990-04 / CNPq / Capes / Este trabalho apresenta um estudo comparativo da aplicação do SPT, da prova de carga sobre placas e do ensaio pressiométrico em projetos de fundações superficiais em solos arenosos, com o objetivo de mostrar a possibilidade do uso alternativo do pressiômetro de Briaud, em substituição à prova de carga e ao SPT, e suas vantagens. O campo experimental é um subsolo areno-siltoso situado na zona urbana de Campina Grande-PB, no qual executa-se sondagensSPT, provas de carga sobre placas apoiadas na superfície, provas de carga, em profundidade - com carregamentos verticais e horizontais - e ensaios pressiométricos em furos verticais e horizontais, além da verificação da densidade in situ e do teor de umidade natural, todos em um perfil com 1,90 m de profundidade. Comenta-se as vantagens e desvantagens dos ensaios realizados e verifica-se que a técnica pressiométrica - via pressiômetro de Briaud - apresenta muitas vantagens sobre a prova de carga e, ainda, que o SPT não deve, isoladamente, ser aplicado para estimar a capacidade de carga de fundações superficiais. Finalmente, conclui-se que os resultados obtidos evidenciam a possibilidade de aplicação do pressiômetro de Briaud, na determinação da capacidade de carga de fundações superficiais, em solos arenosos. / This paper presents a comparative study of the application of the 5PT, of the plate load test, and of the pressuremeter test on shallow foundations projects in sandy soils, aiming at showing the possibility of alternative usage of the BRIAUD pressuremeter test as a substitute to both the plate load test and the 5PT, and their advantages. The experimental field is a silty-sand subsoil situated on the urban área of Campina Grande, Paraíba, where we carry out SPT soundings , plate load tests supported on the surface, plate load tests in depth - with vertical and horizontal loads - and pressuremeter tests in vertical and horizontal holes, besides the verification of the natural unit weight and the natural water content, ali of them in a profile of 1.90 meters deep. Following, we discuss the advantages and disadvantages of the experiments done and we get to know that the pressuremeter technique - throug the BRIAUD pressuremeter - offer many advantages concerning plate load tests; and, in addition, that the 5PT should not, in isolation, be applied to estimate the ultimate bearing capacity of shallow foundations. At the end, we conclude that the results reached give us proof of reasons to believe of the possibility of application of the BRIAUD pressuremeter in determining the bearing capacity of shallow foundations in sandy soils.

Page generated in 0.0846 seconds