Spelling suggestions: "subject:"fundicao"" "subject:"condicao""
21 |
O uso de análise via CAE na fundição sob pressão de ligas de alumínioRebello, Marcos Antonio 24 February 2000 (has links)
Made available in DSpace on 2016-12-08T17:19:17Z (GMT). No. of bitstreams: 1
Marcos Antonio Rebello.pdf: 62475 bytes, checksum: c7f75da092a4bff7d4119324fb70ef07 (MD5)
Previous issue date: 2000-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O uso de simulação para a analise de enchimento de um molde é um importante recurso para otimização de sistemas de canais, localização de bolsas de ar e determinação de parâmetros relativos ao processo de fundição sob pressão. Em função do alto investimento nos moldes para a fundição sob pressão, a simulação torna-se elemento de fundamental importância nas fundições que operam com peças injetadas. Porém, há uma escassez de trabalhos direcionados em assegurar a eficiência do software na otimização deste processo. No presente estudo, usou-se o software Magmasoft , para simular o enchimento de peças injetadas em alumínio. Primeiramente foram feitas comparações com simulações obtidas por diferentes processos de cálculos e diferentes graus de refinamentos de malhas, com objetivo de verificar a sensibilidade do software em relação a convergência de resultados. A seguir foi simulada uma peça simples, já pesquisada por outros autores através de modelos matemáticos diferenciados. O confronto da simulação feita com o material de literatura, mostrou perfil próximo de frente de avanço do metal. Embasado nestes resultados, partiu-se para a situação real com uma peça representativa, fundida em liga AlSi9Cu3. Foram injetados quatro lotes de amostras com velocidades distintas, sendo que três dos lotes apresentavam propositalmente os defeitos de solda fria e porosidade. Paralelamente, usando as informações do processo, as mesmas peças foram simuladas e comparadas através do monitoramento, nas simulações, do perfil da frente de enchimento e da distribuição de temperatura.
|
22 |
Análise in vitro do espaço interno de coroas metálicas em Tilite®, posterior a utilização de alívios sobre troquéis em gessoGranvilla, Anderson January 2008 (has links)
O presente estudo tem como objetivo principal avaliar qual é o número de camadas de espaçadores de troquéis que apresenta o valor mais próximo da especificação número 8 da ADA (Associação Dentária Americana) para a espessura da camada do cimento de fosfato de zinco, utilizado durante a cimentação de uma coroa metálica total. Foi realizado um estudo experimental “in vitro” com a confecção de 20 coroas totais divididas em quatro grupos: grupo controle (sem a aplicação de espaçadores) e grupos com uma, duas e três camadas de espaçadores para troquéis da marca True Spacer (Talladium do Brasil), mesma fábrica que confecciona a liga metálica utilizada, Tilite®. Para avaliar a espessura do alívio, foi utilizado um filme de silicona de adição determinando o espaço existente entre a parede interna da coroa metálica e o troquel mestre. Após a polimerização do material, as coroas foram removidas do troquel e uma silicona ultraleve de outra coloração foi injetada no interior da coroa com o intuito de garantir a remoção da primeira silicona sem distorção. As amostras de siliconas obtidas foram seccionadas transversalmente para serem escaneadas em alta resolução ao lado de um paquímetro. Posteriormente, as imagens assim obtidas foram levadas ao software Image Tool 3.0 (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA). O procedimento realizado foi a mensuração de pontos para a comparação entre os lados oclusal e a parede axial e apresentou valores médios em micrômetros(μm). Posteriormente, foram submetidos à análise estatística com nível de significância de 5%, através do teste t student, ANOVA e teste de Tukey. Os resultados mostraram diferenças significantes estatisticamente entre as faces oclusais e axiais e, entre os grupos não foram significantes, mas estavam próximos da especificação da ADA, concluindo que a utilização de espaçadores promove alívio suficiente para a cimentação. / The aim of the present study is to evaluate what number of die spacer liners has the value to the specification number 8 of the ADA (American Dental Association) for the thickness of the liner of the zinc phosphate cement utilized during the cementation of a metallic crown. An in vitro experimental study was realized with the confection of 20 total crowns divided in four groups: control group (without layers), and groups with one, two and three layers of True Spacer (Talladium Brazil) die spacers of the same factory of the used metallic league. To evaluate the thickness of the relief was utilized a additional silicona for determinate the space between the internal wall of the metallic crown and the master die. The samples of silicona were cross-sectioned at the middle and took. Subsequently, the images thereby achieved were transferred to the Image Tool 3.0 software (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA).The procedures were the measurement of the points in the oclusal side and axial wall and showed average in micrometers. Therefore, had been submitted to statistics analysis with significant level of 5%, through “t student” test, analysis of variance and Tukey test. The results showed significant statistical differences among occlusal and axial faces and between the groups had not been significant, but they were next to the specification of ADA. Concluding that the use of die spacers promove enough relief for the cementation.
|
23 |
Análise in vitro do espaço interno de coroas metálicas em Tilite®, posterior a utilização de alívios sobre troquéis em gessoGranvilla, Anderson January 2008 (has links)
O presente estudo tem como objetivo principal avaliar qual é o número de camadas de espaçadores de troquéis que apresenta o valor mais próximo da especificação número 8 da ADA (Associação Dentária Americana) para a espessura da camada do cimento de fosfato de zinco, utilizado durante a cimentação de uma coroa metálica total. Foi realizado um estudo experimental “in vitro” com a confecção de 20 coroas totais divididas em quatro grupos: grupo controle (sem a aplicação de espaçadores) e grupos com uma, duas e três camadas de espaçadores para troquéis da marca True Spacer (Talladium do Brasil), mesma fábrica que confecciona a liga metálica utilizada, Tilite®. Para avaliar a espessura do alívio, foi utilizado um filme de silicona de adição determinando o espaço existente entre a parede interna da coroa metálica e o troquel mestre. Após a polimerização do material, as coroas foram removidas do troquel e uma silicona ultraleve de outra coloração foi injetada no interior da coroa com o intuito de garantir a remoção da primeira silicona sem distorção. As amostras de siliconas obtidas foram seccionadas transversalmente para serem escaneadas em alta resolução ao lado de um paquímetro. Posteriormente, as imagens assim obtidas foram levadas ao software Image Tool 3.0 (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA). O procedimento realizado foi a mensuração de pontos para a comparação entre os lados oclusal e a parede axial e apresentou valores médios em micrômetros(μm). Posteriormente, foram submetidos à análise estatística com nível de significância de 5%, através do teste t student, ANOVA e teste de Tukey. Os resultados mostraram diferenças significantes estatisticamente entre as faces oclusais e axiais e, entre os grupos não foram significantes, mas estavam próximos da especificação da ADA, concluindo que a utilização de espaçadores promove alívio suficiente para a cimentação. / The aim of the present study is to evaluate what number of die spacer liners has the value to the specification number 8 of the ADA (American Dental Association) for the thickness of the liner of the zinc phosphate cement utilized during the cementation of a metallic crown. An in vitro experimental study was realized with the confection of 20 total crowns divided in four groups: control group (without layers), and groups with one, two and three layers of True Spacer (Talladium Brazil) die spacers of the same factory of the used metallic league. To evaluate the thickness of the relief was utilized a additional silicona for determinate the space between the internal wall of the metallic crown and the master die. The samples of silicona were cross-sectioned at the middle and took. Subsequently, the images thereby achieved were transferred to the Image Tool 3.0 software (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA).The procedures were the measurement of the points in the oclusal side and axial wall and showed average in micrometers. Therefore, had been submitted to statistics analysis with significant level of 5%, through “t student” test, analysis of variance and Tukey test. The results showed significant statistical differences among occlusal and axial faces and between the groups had not been significant, but they were next to the specification of ADA. Concluding that the use of die spacers promove enough relief for the cementation.
|
24 |
[en] DEVELOPMENT OF A METAL MATRIX COMPOSITE BY SPONTANEOUS INFILTRATION: IMAGE ANALYSIS TO ESTIMATE THE PERMEABILITY OF THE CERAMIC PREFORM AND MATHEMATICAL MODELING OF THE METALLIC PHASE INFILTRATION / [pt] OBTENÇÃO DE UM COMPÓSITO DE MATRIZ FERROSA POR INFILTRAÇÃO ESPONTÂNEA: ESTIMATIVA DA PERMEABILIDADE DA PRÉ-FORMA CERÂMICA PORPROCESSAMENTO DE IMAGENS E MODELAGEM MATEMÁTICA DA INFILTRAÇÃO DA FASE METÁLICAFERNANDO ANTONIO RIBEIRO SERRA 30 March 2004 (has links)
[pt] A utilização de compósitos de matriz ferrosa com pré-forma
cerâmica oferece a possibilidade de redução do desgaste
abrasivo em aplicações onde as ligas usuais não são
efetivas. Nesta tese, foi desenvolvido um estudo voltado
para a obtenção de um compósito de matriz metálica com
ênfase na caracterização e previsão da infiltração
espontânea de um ferro fundido nodular através de uma
préforma granulada porosa de óxido de alumínio.
O processo de infiltração de pré-forma porosa constituída
de óxido de alumínio, em três granulometrias distintas
(12#, 16# e 42#), por um ferro fundido nodular de
composição eutética (3,9 graus Celsius) foi realizado em três
temperaturas de vazamento diferentes (1403 graus Celsius, 1299 graus Celsius e
1250 graus Celsius), desde a elaboração das pré-formas passando pela
infiltração do metal, até a caracterização
microestrutural. Os resultados dos ensaios de compressão
com as pré-formas foram processados por análise fatorial e
mostraram que, dentro dos níveis estudados, o percentual
utilizado de ligante (silicato de sódio) e o tempo de cura
influenciam positivamente e de forma mais significativa do
que a granulometria do óxido de alumínio. A microestrutura
da matriz foi afetada pelos grãos cerâmicos da préforma,
fato este caracterizado pela presença de veios de grafita
no lugar de nódulos em uma extensão variável entre 10 micrômetros e
60 micrômetros a partir da superfície do grão. Após a permeabilidade
da pré-forma cerâmica ter sido estimada por
processamento digital de imagens em 3D, foi desenvolvido
um modelo matemático voltado para a identificação da
penetração máxima da fase metálica levando em consideração
as temperaturas de vazamento e de solidificação do ferro
fundido. As curvas do modelo mostraram boa correlação
quando comparados com os resultados experimentais. / [en] Iron metal matrix composites in aluminium oxide offers an
outstanding possibility to reduce abrasive wear where
usual alloys are not working well. For the present study
the composite was obtained by carrying out an
spontaneous infiltration of an eutectic (3,9 degrees Celsius) nodular
iron in a preform made with three aluminiun oxide
granulometries (#12, #16 and #42), in three different
pouring temperatures (1403 degrees Celsius, 1299 degrees Celsius e 1250 degrees Celsius). The
preforms compression tests results were processed by
factorial analysis and showed a greater influence of the
sodium silicate amount and the curing time over the
aluminium oxide granulometry. After the estimation of the
ceramic phase permeability by 3D image digital
processing it was developed a mathematical model to
predict the maximum infiltration of the ferrous melt
through the ceramic phase. It was based on the
pouring and alloy solidification temperatures and produced
a good agreement with the experimental results.
The matrix microstructure was affected by the ceramic
grains. This was characterized by the presence of lamellar
graphite instead of the expected nodules in an extension
between 10 micrometers and 60 micrometers from the border of the composite.
|
25 |
Análise in vitro do espaço interno de coroas metálicas em Tilite®, posterior a utilização de alívios sobre troquéis em gessoGranvilla, Anderson January 2008 (has links)
O presente estudo tem como objetivo principal avaliar qual é o número de camadas de espaçadores de troquéis que apresenta o valor mais próximo da especificação número 8 da ADA (Associação Dentária Americana) para a espessura da camada do cimento de fosfato de zinco, utilizado durante a cimentação de uma coroa metálica total. Foi realizado um estudo experimental “in vitro” com a confecção de 20 coroas totais divididas em quatro grupos: grupo controle (sem a aplicação de espaçadores) e grupos com uma, duas e três camadas de espaçadores para troquéis da marca True Spacer (Talladium do Brasil), mesma fábrica que confecciona a liga metálica utilizada, Tilite®. Para avaliar a espessura do alívio, foi utilizado um filme de silicona de adição determinando o espaço existente entre a parede interna da coroa metálica e o troquel mestre. Após a polimerização do material, as coroas foram removidas do troquel e uma silicona ultraleve de outra coloração foi injetada no interior da coroa com o intuito de garantir a remoção da primeira silicona sem distorção. As amostras de siliconas obtidas foram seccionadas transversalmente para serem escaneadas em alta resolução ao lado de um paquímetro. Posteriormente, as imagens assim obtidas foram levadas ao software Image Tool 3.0 (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA). O procedimento realizado foi a mensuração de pontos para a comparação entre os lados oclusal e a parede axial e apresentou valores médios em micrômetros(μm). Posteriormente, foram submetidos à análise estatística com nível de significância de 5%, através do teste t student, ANOVA e teste de Tukey. Os resultados mostraram diferenças significantes estatisticamente entre as faces oclusais e axiais e, entre os grupos não foram significantes, mas estavam próximos da especificação da ADA, concluindo que a utilização de espaçadores promove alívio suficiente para a cimentação. / The aim of the present study is to evaluate what number of die spacer liners has the value to the specification number 8 of the ADA (American Dental Association) for the thickness of the liner of the zinc phosphate cement utilized during the cementation of a metallic crown. An in vitro experimental study was realized with the confection of 20 total crowns divided in four groups: control group (without layers), and groups with one, two and three layers of True Spacer (Talladium Brazil) die spacers of the same factory of the used metallic league. To evaluate the thickness of the relief was utilized a additional silicona for determinate the space between the internal wall of the metallic crown and the master die. The samples of silicona were cross-sectioned at the middle and took. Subsequently, the images thereby achieved were transferred to the Image Tool 3.0 software (Department of Dental Science Diagnostic at the University of Texas, Health of Science Center, San Antonio, USA).The procedures were the measurement of the points in the oclusal side and axial wall and showed average in micrometers. Therefore, had been submitted to statistics analysis with significant level of 5%, through “t student” test, analysis of variance and Tukey test. The results showed significant statistical differences among occlusal and axial faces and between the groups had not been significant, but they were next to the specification of ADA. Concluding that the use of die spacers promove enough relief for the cementation.
|
Page generated in 0.0376 seconds