1

Safeguards assessment of gamma-ray detection for process monitoring at natural uranium conversion facilities

Dewji, Shaheen Azim 22 May 2014 (has links)
Conversion, the process by which natural uranium ore (yellowcake) is purified and converted through a series of chemical processes into uranium hexafluoride gas (UF6), has historically been excluded from the nuclear safeguards requirements of the 235U-based nuclear fuel cycle. With each step in the conversion process from yellowcake to feedstock for UF6, intermediary uranium oxide and uranium fluoride compounds become progressively attractive products for diversion toward activities noncompliant with international treaties. The diversion of this product material could potentially provide feedstock for a clandestine or undeclared enrichment for weapons development for state or non-state entities. With the realization of this potential, the International Atomic Energy Agency (IAEA) has only recently reinterpreted its policies to emphasize safeguarding this feedstock in response to such diversion pathways. This project employs a combination of simulation models and experimental measurements to develop and validate concepts of nondestructive assay monitoring systems in a natural uranium conversion plant (NUCP). In particular, uranyl nitrate (UN) solution exiting solvent extraction was identified as a key measurement point (KMP), where gamma-ray spectroscopy was selected as the process-monitoring tool. The Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility at Oak Ridge National Laboratory was employed to simulate the full-scale operating conditions of a purified uranium-bearing aqueous stream exiting the solvent extraction process in an NUCP. This work investigates gamma-ray signatures UN circulating in the UNCLE facility and evaluates various gamma-ray detector (HPGe, LaBr3 and NaI) sensitivities to UN.
2

Design And Development Of A Liquid Scintillator Based System For Failed Fuel Detection And Locating System In Nuclear Reactors

Sumanth, Panyam 05 1900 (has links)
Failed fuel refers to the breach in the fuel-clad of an irradiated fuel assembly in a nuclear reactor. Neutron detection or gamma detection is commonly used in Failed Fuel Detection and Locating (FFDL) system to monitor the activity of the coolant. Though these methods offer specific advantages under different conditions of the coolant, providing both types of detectors in FFDL system is impractical. This limitation is the motivation for the detector system developed in the present work. In the present work, effort has been made for realising a detector system for simultaneous measurement of neutron and gamma activity of the coolant, thus offering a two-parameter basis for failed fuel detection. NE213 liquid scintillator was chosen for this work as it has good detection capability for both neutrons and gammas. Additionally, the neutrons and gammas interacting with NE213 detector can be separated based on pulse shape discrimination. The work reported in this thesis includes fabrication details and different steps followed in assembling the NE213 detector. Details of experimental set-up developed for pulse height analysis and pulse shape analysis are covered. Results of experiments carried out to study the response of the NE213 detector to gamma and neutron sources using pulse height analyser are presented. The absolute gamma efficiency and relative gamma efficiency of NE213 detector are calculated. Neutron–gamma separation capability of NE213 detector based pulse shape analysis system is reported. Application of the developed detector system to analyse the coolant activity in FFDL system in a reactor is described. Response of the detector is compared with the existing FFDL system at different power levels of the reactor. Since failed fuel is a rare event, it was simulated using neutron and gamma sources. Pulse shape analysis spectra obtained under simulated failed fuel condition are presented.
3

Development of a data acquisition architecture with distributed synchronization for a Positron Emission Tomography system with integrated front-end

Aliaga Varea, Ramón José 02 May 2016 (has links)
[EN] Positron Emission Tomography (PET) is a non-invasive nuclear medical imaging modality that makes it possible to observe the distribution of metabolic substances within a patient's body after marking them with radioactive isotopes and arranging an annular scanner around him in order to detect their decays. The main applications of this technique are the detection and tracing of tumors in cancer patients and metabolic studies with small animals. The Electronic Design for Nuclear Applications (EDNA) research group within the Instituto de Instrumentación para Imagen Molecular (I3M) has been involved in the study of high performance PET systems and maintains a small experimental setup with two detector modules. This thesis is framed within the necessity of developing a new data acquisition system (DAQ) for the aforementioned setup that corrects the drawbacks of the existing one. The main objective is to define a DAQ architecture that is completely scalable, modular, and guarantees the mobility and the possibility of reusing its components, so that it admits any extension of modification of the setup and it is possible to export it directly to the configurations used by other groups or experiments. At the same time, this architecture should be compatible with the best possible resolutions attainable at the present instead of imposing artificial limits on system performance. In particular, the new DAQ system should outperform the previous one. As a first step, a general study of DAQ arquitectures is carried out in the context of experimental setups for PET and other high energy physics applications. On one hand, the conclusion is reached that the desired specifications require early digitization of detector signals, exclusively digital communication between modules, and the absence of a centralized trigger. On the other hand, the necessity of a very precise distributed synchronization scheme between modules becomes apparent, with errors in the order of 100 ps, and operating directly over the data links. A study of the existing methods reveals their severe limitations in terms of achievable precision. A theoretical analysis of the situation is carried out with the goal of overcoming them, and a new synchronization algorithm is proposed that is able to reach the desired resolution while getting rid of the restrictions on clock alignment that are imposed by virtually all usual schemes. Since the measurement of clock phase difference plays a crucial role in the proposed algorithm, extensions to the existing methods are defined and analyzed that improve them significantly. The proposed scheme for synchronism is validated using commercial evaluation boards. Taking the proposed synchronization method as a starting point, a DAQ architecture for PET is defined that is composed of two types of module (acquisition and concentration) whose replication makes it possible to arrange a hierarchic system of arbitrary size, and circuit boards are designed and commissioned that implement a realization of the architecture for the particular case of two detectors. This DAQ is finally installed at the experimental setup, where their synchronization properties and resolution as a PET system are characterized and its performance is verified to have improved with respect to the previous system. / [ES] La Tomografía por Emisión de Positrones (PET) es una modalidad de imagen médica nuclear no invasiva que permite observar la distribución de sustancias metabólicas en el interior del cuerpo de un paciente tras marcarlas con isótopos radioactivos y disponer después un escáner anular a su alrededor para detectar su desintegración. Las principales aplicaciones de esta técnica son la detección y seguimiento de tumores en pacientes con cáncer y los estudios metabólicos en animales pequeños. El grupo de investigación Electronic Design for Nuclear Applications (EDNA) del Instituto de Instrumentación para Imagen Molecular (I3M) ha estado involucrado en el estudio de sistemas PET de alto rendimiento y mantiene un pequeño setup experimental con dos módulos detectores. La presente tesis se enmarca dentro de la necesidad de desarrollar un nuevo sistema de adquisición de datos (DAQ) para dicho setup que corrija los inconvenientes del ya existente. En particular, el objetivo es definir una arquitectura de DAQ que sea totalmente escalable, modular, y que asegure la movilidad y la posibilidad de reutilización de sus componentes, de manera que admita cualquier ampliación o alteración del setup y pueda exportarse directamente a los de otros grupos o experimentos. Al mismo tiempo, se desea que dicha arquitectura no limite artificialmente el rendimiento del sistema sino que sea compatible con las mejores resoluciones disponibles en la actualidad, y en particular que sus prestaciones superen a las del DAQ instalado previamente. En primer lugar, se lleva a cabo un estudio general de las arquitecturas de DAQ para setups experimentales para PET y otras aplicaciones de física de altas energías. Por un lado, se determina que las características deseadas implican la digitalización temprana de las señales del detector, la comunicación exclusivamente digital entre módulos, y la ausencia de trigger centralizado. Por otro lado, se hace patente la necesidad de un esquema de sincronización distribuida muy preciso entre módulos, con errores del orden de 100 ps, que opere directamente sobre los enlaces de datos. Un estudio de los métodos ya existentes revela sus graves limitaciones a la hora de alcanzar esas precisiones. Con el fin de paliarlos, se lleva a cabo un análisis teórico de la situación y se propone un nuevo algoritmo de sincronización que es capaz de alcanzar la resolución deseada y elimina las restricciones de alineamiento de reloj impuestas por casi todos los esquemas usuales. Dado que la medida de desfase entre relojes juega un papel crucial en el algoritmo propuesto, se definen y analizan extensiones a los métodos ya existentes que suponen una mejora sustancial. El esquema de sincronismo propuesto se valida utilizando placas de evaluación comerciales. Partiendo del método de sincronismo propuesto, se define una arquitectura de DAQ para PET compuesta de dos tipos de módulos (adquisición y concentración) cuya replicación permite construir un sistema jerárquico de tamaño arbitrario, y se diseñan e implementan placas de circuito basadas en dicha arquitectura para el caso particular de dos detectores. El DAQ así construído se instala finalmente en el setup experimental, donde se caracterizan tanto sus propiedades de sincronización como su resolución como sistema PET y se comprueba que sus prestaciones son superiores a las del sistema previo. / [CA] La Tomografia per Emissió de Positrons (PET) és una modalitat d'imatge mèdica nuclear no invasiva que permet observar la distribució de substàncies metabòliques a l'interior del cos d'un pacient després d'haver-les marcat amb isòtops radioactius disposant un escàner anular al seu voltant per a detectar la seua desintegració. Aquesta tècnica troba les seues principals aplicacions a la detecció i seguiment de tumors a pacients amb càncer i als estudis metabòlics en animals petits. El grup d'investigació Electronic Design for Nuclear Applications (EDNA) de l'Instituto de Instrumentación para Imagen Molecular (I3M) ha estat involucrat en l'estudi de sistemes PET d'alt rendiment i manté un petit setup experimental amb dos mòduls detectors. Aquesta tesi neix de la necessitat de desenvolupar un nou sistema d'adquisició de dades (DAQ) per al setup esmentat que corregisca els inconvenients de l'anterior. En particular, l'objectiu és definir una arquitectura de DAQ que sigui totalment escalable, modular, i que asseguri la mobilitat i la possibilitat de reutilització dels seus components, de tal manera que admeta qualsevol ampliació o alteració del setup i pugui exportar-se directament a aquells d'altres grups o experiments. Al mateix temps, es desitja que aquesta arquitectura no introduisca límits artificials al rendiment del sistema sinó que sigui compatible amb les millors resolucions disponibles a l'actualitat, i en particular que les seues prestacions siguin superiors a les del DAQ instal.lat amb anterioritat. En primer lloc, es porta a terme un estudi general de les arquitectures de DAQ per a setups experimentals per a PET i altres aplicacions de física d'altes energies. Per una banda, s'arriba a la conclusió que les característiques desitjades impliquen la digitalització dels senyals del detector el més aviat possible, la comunicació exclusivament digital entre mòduls, i l'absència de trigger centralitzat. D'altra banda, es fa palesa la necessitat d'un mecanisme de sincronització distribuïda molt precís entre mòduls, amb errors de l'ordre de 100 ps, que treballi directament sobre els enllaços de dades. Un estudi dels mètodes ja existents revela les seues greus limitacions a l'hora d'assolir aquest nivell de precisió. Amb l'objectiu de pal.liar-les, es duu a terme una anàlisi teòrica de la situació i es proposa un nou algoritme de sincronització que és capaç d'obtindre la resolució desitjada i es desfà de les restriccions d'alineament de rellotges imposades per gairebé tots els esquemes usuals. Atès que la mesura del desfasament entre rellotges juga un paper cabdal a l'algoritme proposat, es defineixen i analitzen extensions als mètodes ja existents que suposen una millora substancial. L'esquema de sincronisme proposat es valida mitjançant plaques d'avaluació comercials. Prenent el mètode proposat com a punt de partida, es defineix una arquitectura de DAQ per a PET composta de dos tipus de mòduls (d'adquisició i de concentració) tals que la replicació d'aquests elements permet construir un sistema jeràrquic de mida arbitrària, i es dissenyen i implementen plaques de circuit basades en aquesta arquitectura per al cas particular de dos detectors. L'electrònica desenvolupada s'instal.la finalment al setup experimental, on es caracteritzen tant les seues propietats de sincronització com la seua resolució com a sistema PET i es comprova que les seues prestacions són superiors a les del sistema previ. / Aliaga Varea, RJ. (2016). Development of a data acquisition architecture with distributed synchronization for a Positron Emission Tomography system with integrated front-end [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/63271 / TESIS / Premios Extraordinarios de tesis doctorales