• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 23
  • 8
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 179
  • 179
  • 47
  • 45
  • 44
  • 40
  • 40
  • 34
  • 32
  • 28
  • 26
  • 26
  • 25
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Vidas-médias de núcleos de A~130 / Medium-lives Nuclei A~130

Botelho, Suzana 01 February 1996 (has links)
As vidas-médias dos três primeiros níveis da banda-yrast I=2 construída sobre o estado h11/2- do núcleo de 135Pr, foram medidas, pela primeira vez, através da reação 121,123Sb(16O, 4n)133,135Pr, a 76 MeV, usando-se espectroscopia gama em conjunto com a técnica de medida da distância de recuo (RDM), no Laboratório PELLETRON, São Paulo, e TANDAR/CNEA, Buenos Aires, Argentina. Foram calculadas as probabilidades reduzidas de transição B(E2), com o objetivo de extrair informações sobre os parâmetros de deformação, os quais foram comparados às estimativas feitas pelos modelos teóricos para a região de massa A~130, como o modelo de um rotor triaxial mais quasi-partícula, o modelo geométrico e o TRS (\"Total Routhian Surface\"). Os valores experimentais das vidas-médias, dos B(E2) e dos parâmetros de deformação (B2, y) de 135Pr, foram comparados ao caroço de 134Ce, medido em [Hu77]. Os valores experimentais de Q0 obtidos para os três primeiros níveis da banda h11/2- de 135Pr, antes do backbending, são bastante parecidos aos do 134Ce. Cálculos teóricos para os dois núcleos, usando o programa TRS, forneceram resultados que estão em contraste com os experimentais. / Lifetimes of low-Iying states in I=2 bands built on the h11/2- state in the Z-odd nucleus 135Pr were measured by means of the 121,123Sb(16O,4n)133,135Pr reaction at a bombarding energy of 76 MeV, using in-beam gamma-ray spectroscopy together with the Doppler-Shift Recoil-Distance Technique at the PELLETRON, São Paulo and the TANDAR/CNEA Laboratory, Buenos Aires, Argentina. Reduced transition probabilities B(E2) were extracted in order to calculate the deformation parameters. These values were compared to theoretical models available for the mass region A~130, such as the Triaxial Rotor plus Quasi-Particle, the Cranked-Shell Model, the Geometrical Model and the Total Routhian Surface. The experimental values of 135Pr lifetimes, B(E2) and deformation parameters (B2, y) were compared to those for the 134Ce core, measured in [Hu77]. It was found that Q0 values for the h11/2- excited levels before backbending in 135Pr nucleus are very similar to those of the 134Ce core. TRS calculations were performed for both nuclei giving theoretical results which are in contrast to the experimental values.
12

Medidas Precisas de Energias de Transições Gama em Coincidência: Espectroscopia das Séries do 232U e 233U / Accurate measures of energies of gamma transitions in coincidence: 232U and 233U series of spectroscopy.

Guimarães Filho, Zwinglio de Oliveira 03 December 1998 (has links)
Este trabalho apresenta um método experimental para determinação de energia de transições gama utilizando-se detectores de HPGe em experimentos em coincidência com precisões similares às que se obtém em medidas simples. O método foi aplicado na medida das energias das transições gama dos decaimentos das séries do 233U e 232U. Matrizes de covariância de dados experimentais são tão significativas quando suas variâncias para a avaliação de incertezas experimentais e indispensáveis para a atualização e combinação de resultados. O procedimento desenvolvido neste trabalho utiliza-se de toda a matriz de covariância das energias das transições gama bem como das matrizes de covariâncias de todos os parâmetros em todas as etapas da análise. O arranjo experimental utilizou o módulo multidetector, padrão Camac, desenvolvido no Laboratório do Acelerador Linear. Os dados foram analisados usando o programa Bidim, desenvolvido durante este trabalho. O procedimento de ajuste, baseado no método dos mínimos quadrados, é aplicado diretamente sobre o espectro bidimensional. A precisão final das energias das transições gama foram iguais ou superiores a cerca de 5eV. Testes de qui-quadrado dos ajustes, sempre melhores que 15%, não indicaram a presença de inconsistências. / This work presents an experimental method for determining gamma-ray energies employing HPGe detectors in coincidence experiments with precision similar to that obtained in single measurements. The method was applied in the measurement of gamma-ray energies from the decay chain of 233U and 232U. Covariance matrices between experimental data are as significant as variances in the evaluation of experimental uncertainties and indispensable for updating and combining experimental results. In this work the complete covariance matrices for the gamma-ray energies and for all parameters used in the developed procedure were determined in every stage of the work. The experimental apparatus used the Camac multidetector adapter developed in the Laboratório do Acelerador Linear. The data were analyzed using the software Bidim, developed during this work. The fitting procedure, based on the least squares method, was applied directly to the two-dimensional spectra. The best final precision of the gamma-ray energies was about 5eV. Chi-squared tests of the fit, always better than 15%, do not indicate the presence of inconsistencies.
13

Espectroscopia gama e correlação angular gama-gama em 194Pt / Gamma spectroscopy and gamma-gamma angular correlation in 194 Pt

Teixeira, Ricardo Roberto Plaza 20 June 1996 (has links)
Foram realizadas medidas de espectroscopia gama simples, de espectroscopia. gama-gama em coincidência e de correlação angular para o estudo de \'ANTPOT 194 PT\', a partir do decaimento por \'beta POT. +\' e por captura eletrônica de \'ANTPOT 194 AU\'. Foram determinadas, utilizando um cálculo covariante, as energias e as intensidades de 167 transições gama, das quais 31 pela primeira vez: 212 keV, 243 keV, 304 keV, 338 keV, 363 keV, 366 keV, 373 keV, 398 keV, 421 keV, 436 keV, 500 keV, 602 keV, 627 keV, 699 keV, 807 keV, 814 keV, 857 keV, 901 keV, 1121 keV, 1262 keV, 1346 keV, 1388 keV, 1474 keV, 1488 keV, 1535 keV, 1541 keV, 1565 keV, 1665 keV, 1675 keV, 1775 keV e 1780 keV. O esquema de níveis obtido contém 45 estados; destes estados, 4 foram determinados pela primeira vez: 1373 keV, 1737 keV, 2003 keV e 2140 keV. Foram determinados os valores para as razões de mistura multipolar \'delta\'(E2/M1) das transições mais intensas utilizando o método de correlação angular direcional gama-gama. Utilizando elipses de correlação, foi possível determinar ou restringir os valores do spin e/ou paridade de 7 níveis: 1373 keV, 1737 keV, 1778 keV, 1930 keV, 2052 keV, 2134 keV e 2157 keV. Cálculos usando o formalismo de Kumar e Baranger para a resolução do Hamiltoniano de Bohr foram realizados para o núcleo \'ANTPOT 194 PT\'. Foram então determinados níveis e propriedades eletromagnéticas e os resultados, discutidos. / Single gamma ray spectroscopy, gamma-gamma spectroscopy and gamma-gamma directional angular correlation have been performed to study the \'ANTPOT 194 PT\', following the \'beta POT. + \' decay and electron capture of \'ANTPOT 194 AU\'. We have determined, using covariant calculations, energies and intensities of 167 gamma transitions, 31 of them for the first time: 212 keV, 243 keV, 304 keV, 338 keV, 363 keV, 366 keV, 373 keV, 398 keV, 421 keV, 436 keV, 500 keV, 602 keV, 627 keV, 699 keV, 807 keV, 814 keV, 857 keV, 901 keV, 1121 keV, 1262 keV, 1346 keV, 1388 keV, 1474 keV, 1488 keV, 1535 keV, 1541 keV, 1565 keV, 1665 keV, 1675 keV, 1775 keV and 1780 keV. The decay scheme contains 45 levels; 4 of these states have been determined for the first time: 1373 keV, 1737 keV, 2003 keV and 2140 keV. We have also determined values for the multipole rnixing ratios \'delta\'(E2/M1) in the case of the strongest transitions, using directional gamma-gamma angular correlation. With the angular correlation ellipses, it was possible to determine or to restrict the spin and/or parity values of 7 levels: 1373 keV, 1737 keV, 1778 keV, 1930 keV, 2052 keV, 2134 keV and 2157 keV.
14

Estudo do decaimento do 132Cs e estrutura nuclear do 132Xe / Study Decay 132Cs Nuclear Structure 132Xe

Cruz, Manoel Tiago Freitas da 19 November 1987 (has links)
Foram estudados os decaimentos BETA-, BETA+ e por captura de elétrons do 132 Cs. Foram medidas misturas multipolares E2/M1 de transições pelo método de correlação angular direcional gama-gama. Foi aplicado o modelo de Bohr na formulação K. Kumar e M. Baranger ao 132 Xe e os resultados são discutidos. / The 132 Cs BETA-, BETA+ and electron capture decays have been studied. New gamma transitions and electron capture feedings were determined. Some E2/M1 multipole mixings of gamma transitions in 132 Xe and 132Ba were measured with the gamma-gamma angular directional correlation method. The Bohr\'s collective model with K. Kumar and M. Baranger\'s solution was applied to 132 Xe and the results were discussed.
15

Aplicação dos métodos radioquímico e de espectrometria de raios gama direto para determinação da queima do óxido de urânio irradiado

CUNHA, IEDA I.L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:01Z (GMT). No. of bitstreams: 1 00489.pdf: 2163294 bytes, checksum: 196f74ff6ebe12447bea84e82e4ebc7f (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Quimica, Universidade de Sao Paulo - IQ/USP
16

Desenvolvimento de um codigo computacional aberto de analise quantitativa para determinacao de radionuclideos por espectrometria gama com detectores semicondutores / Development of an open source software of quantitative analysis for radionuclide determination by gamma-ray spectrometry using semiconductor detectors

MADUAR, MARCELO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:16Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
17

Determinacao de spins e larguras radioativas dos niveis nucleares do Telurio com raios gama de captura

BIANCHINI, FERNANDO G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:04Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:42Z (GMT). No. of bitstreams: 1 01327.pdf: 1974517 bytes, checksum: a3167e3356fb407015ce2805648b3b94 (MD5) / Tese (Doutoramento) / IEA/T / Instituto de Fisica, Universidade de Campinas - IF/UNICAMP
18

Aquisicao de dados em espectroscopia gama nuclear

BARG FILHO, DAVID 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:04Z (GMT). No. of bitstreams: 1 07068.pdf: 6722891 bytes, checksum: c0a7ba8c3ee901d4a4cb2946b283b9c6 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
19

Aplicação dos métodos radioquímico e de espectrometria de raios gama direto para determinação da queima do óxido de urânio irradiado

CUNHA, IEDA I.L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:01Z (GMT). No. of bitstreams: 1 00489.pdf: 2163294 bytes, checksum: 196f74ff6ebe12447bea84e82e4ebc7f (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Quimica, Universidade de Sao Paulo - IQ/USP
20

Desenvolvimento de um codigo computacional aberto de analise quantitativa para determinacao de radionuclideos por espectrometria gama com detectores semicondutores / Development of an open source software of quantitative analysis for radionuclide determination by gamma-ray spectrometry using semiconductor detectors

MADUAR, MARCELO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:16Z (GMT). No. of bitstreams: 0 / A quantificação da atividade de radionuclídeos emissores de raios gama em amostras medidas por espectrometria gama com detectores HPGe depende da análise dos fotopicos presentes no espectro, especialmente da determinação exata das suas áreas líquidas. Tal análise é geralmente realizada com o auxílio de ferramentas de software proprietário. Este trabalho apresenta uma metodologia, descrição de algoritmos e um aplicativo de código aberto, denominado OpenGamma, para a busca e análise de fotopicos a fim de se obter seus parâmetros relevantes e as atividades dos radionuclídeos na amostra. A implementação computacional é distribuída sob licença aberta para o código principal e com o uso de pacotes de software aberto para o projeto da interface e para bibliotecas matemáticas. O procedimento para a busca de picos é realizado em três etapas. Primeiramente, executa-se uma pesquisa preliminar com o método da segunda diferença, que consiste na geração de um espectro derivado para a busca de picos candidatos. Na segunda etapa, calculam-se as larguras experimentais dos picos, dos quais escolhem-se aqueles bem formados e isolados para a obtenção da função de ajuste da largura vs. canal, por meio do método de Levenberg-Marquardt para ajustes não-lineares. Por fim, regiões do espectro com picos agrupados são delimitadas e novo ajuste não-linear é aplicado a cada região para a obtenção dos termos da linha de base e dos fotopicos. A partir destes termos, são calculadas as áreas líquidas dos picos. Para a determinação da atividade, curvas de calibração de eficiência previamente obtidas, bem como dados de transições gama dos radionuclídeos, são incorporadas ao código e aplicadas. O código foi escrito em linguagem C++ e a interface foi desenvolvida com a ferramenta Qt. Para as funções matemáticas e procedimentos de ajuste, foi usada a biblioteca científica GNU (GSL). A validação de código foi feita por meio da análise de: 1) espectros sintéticos de teste da AIEA, especialmente desenhados para a avaliação de desempenho de software; 2) espectros obtidos com amostras de exercícios de intercomparação e 3) espectros da rotina de trabalho do Laboratório de Radiometria Ambiental (LRA) do IPEN e analisados com o aplicativo comercial InterWinner. Os resultados obtidos são consistentes com os valores de referência e com aqueles obtidos pelo aplicativo citado, sugerindo que o código OpenGamma pode ser utilizado com segurança na espectrometria de raios gama de uso geral. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0598 seconds