• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Retrospektive Analyse zur Bewertung der Vena femoralis als Bypassmaterial beim tiefen Protheseninfekt / Retrospectiv analysis of the deep vein as a bypass material for reconstruction after a deep prostetic vascular graft infection

Richwien, Daniela Maria January 2013 (has links) (PDF)
Einleitung: Die Protheseninfektion ist in der Gefäßchirurgie eine seltene, aber gefürchtete Komplikation, da sie bis dato immer noch mit einer hohen Mortalität und Morbidität einhergeht. Protheseninfektionen werden in verschiedenen Klassifikationen dargestellt. Die Pathophysiologie des Infektes verläuft über die Aktivierung des Immunsystems und die Fähigkeit der Erreger, sich vor den Angriffen des Immunsystems zu schützen. Dabei ist der häufigste Kontaminationsweg die lokale Kontamination im OP-Gebiet. Der häufigste Erreger stellt der Biofilm bildende Staphylococcus aureus dar. Nach präoperativer Diagnostik erfolgt die vollständige Explantation der infizierten Gefäßprothese mit lokalem radikalem Debridement des Entzündungsgewebes und Wiederherstellung der Perfusion. Für diesen Gefäßersatz stehen verschiedene Materialien zur Verfügung. Material und Methoden: Ziel dieser Arbeit ist es, retrospektiv die Therapie der tiefen Protheseninfektion mittels autologer In-Situ-Rekonstruktion durch die V. femoralis superficialis im Zeitraum von September 2003 bis Juni 2010 an der Universitätsklinik in Würzburg zu analysieren. Es wurden insgesamt 24 Patienten behandelt. Es erfolgte eine detaillierte Aufarbeitung der Krankengeschichte, der mikrobiologischen Befunde, sowie der Operationsberichte und Folgeeingriffe. Des Weiteren wurde eine Kontrolluntersuchung im Rahmen der gefäßchirurgischen Sprechstunde durchgeführt. Ergebnisse: 20 Männer und vier Frauen wurden aufgrund einer Protheseninfektion (6x Frühinfekt, 14x Spätinfekt, 2x persistierender Infekt) operiert, nachdem ihnen eine aortoiliacale, aortofemorale oder iliacofemorale Kunststoffprothese zur Behandlung einer pAVK, eines Aneurysmas, oder aufgrund beider Entitäten implantiert worden war. Am häufigsten zeigte sich als klinisches Erstsymptom eine inguinale Wundheilungsstörung. Lymphfisteln und Infektblutungen belegten Platz zwei und drei. Jedes Mal wurde die V. femoralis superficialis (11x beidseits, 13x einseitig) entnommen, in acht Fällen kombiniert mit der V. saphena magna. 23x erfolgte die Rekonstruktion der Perfusion in-situ, lediglich einmal als extraanatomischer Obturator-Bypass. Bei 19 Patienten (79,2%) konnte ein Pathogen nachgewiesen werden, bei fünf Patienten (20,8%) nicht. In 54,2% der Fälle lag eine Monoinfektion vor, bei 12,5% eine Mischinfektionen. Der häufigste Erreger mit 25% Anteil war Staphylococcus aureus, zweimal gelang der Nachweis eines MRSA. Insgesamt kam es bei sieben Patienten zum Nachweis eines gram-positiven Pathogens, bei sechs Patienten eines gram-negativen Pathogens, was der allgemeinen Entwicklung entspricht. Bei elf Patienten (45,8%) kam es zu einer postoperativen inguinalen Wundheilungsstörung. Deshalb erfolgten auch die meisten Folgeeingriffe mit chirurgischer Wundtoilette, Vakuum-Okklusiv-Verband, Sekundärnaht oder Meshgraft-Deckung als definitiven Wundverschluss. Fünf Patienten (20,8%) erlitten eine periphere Ischämie bzw. einen Bypass-Verschluss. Davon wurden zwei Patienten auf Höhe des Oberschenkels amputiert. Ein Viertel der Patienten verstarb noch während des stationären Aufenthaltes. Das Gesamtüberleben am untersuchten Patientengut betrug bei Durchführung dieser Doktorarbeit die Zahl zehn. Sieben Patienten stellten sich zur Kontrolluntersuchung vor, dreien war dies nur schriftlich möglich. Zweimal erfolgte poststationär eine Ischämie-bedingte Majoramputation. Alle Patienten waren infektfrei. Ein Patient erhielt eine PTA bei Stenose der A. femoralis superficialis rechts nach autologem aortobifemoralem Ersatz. Nach Venenentnahme besteht jedoch bei fünf von sieben Patienten ein mildes bis mittelschweres Phlebödem (1-2cm Umfangszunahme am Knöchel) nach Porter. Zwei Patienten erhalten bis dato eine Lymphdrainage. Zusammenfassung: Die Protheseninfektion ist eine technische Herausforderung, insbesondere wenn die Aorta mitbetroffen ist. Die V. femoralis superficialis erscheint aktuell die erste Wahl bei Notwendigkeit eines großlumigen Gefäßersatzes zu sein. Sie garantiert bis dato eine Infektfreiheit und eine nahezu hundertprozentige Offenheitsrate. Jedoch ist eine präoperative Patientenselektion aufgrund der generell hohen Mortalität und Morbidität durchzuführen und es sind alle Alternativen zu prüfen, um im Individualfall die bestmögliche Lösung für Patient und behandelnden Arzt zu finden. Denn zur Behandlung einer Protheseninfektion gibt es zurzeit noch keinen Goldstandard. Ob es bei dieser komplexen Art der Erkrankung jedoch jemals EINEN Goldstandard geben wird, ist zu bezweifeln. Weitere Diskussionen und Entwicklungen werden und müssen folgen. / Introduction: The prostectic vascular graft infection is a rare, but dreaded complication, connected to a high rate of mortality and morbidity. The prostetic vascular graft infections are divided in different classifications. The pathophysiology depends on the activation of the immun system and the defence strategies of the pathogen to hide from it. The most common way of contamination is intraoperativ. The most common pathogen is Staphylococcus aureus, which is able to built a biofilm. After the whole praeoperativ diagnostic the infected prostetic vascular graft is explanted including a radicale surgigal debridement of the surrounded tissue and the Perfusion is reconstructed again. There are different materials for this vascular Bypass. Materials and Methods: The aim of this study was to analyse retrospectively the therapy of the deep prostetic vascular graft infection with the autologes deep vein in-situ-reconstruction from septembre 2003 to june 2010 at the surgical departement I at the University Hospital in Würzburg. 24 patients has been treated. The patients were analysed by their history of sickness, microbiology, typs of operation and the following revisions. There was a follow-up during the vascular consultation hour. Results: 20 men and 4 women were treated because of a deep prostetic vascular graft infection (6x early infect, 14 late infect, 2 persistend infect) after having a surgery with aortoiliacal, aortofemoral or iliacofemoral Bypass in case of peripheral vascular occlusive desease or in case of an abdominal aneurysm or because of both. The most common clinic Symptome in case of infection was a inguinal wound with secretion. Second and third place has been a lymphozyste oder a bleeding. Every time the deep vein namened V. femoralis superficialis was harvested, 8 times with the V. saphena magna. The reconstruction for Perfusion was 23 times an in-situ- reconstruction, only one time an extra-anatomic Obuturator-Bypass. There was a positiv microbiolgy in 19 cases (79,2%), in 5 cases a negative (20,8%). In 54,2 % there was a mono-infection, in 12,5 % a mixed one. The most common pathogen was Staphylococcus aureus, 2 times with MRSA. 7 patients had a gram positive pathogen, and 7 a gram negative, which is simillar to the General developement of microbiolocigal findings. 11 patients had again a bad wound healing with the most following operations with wound debridement, vacuum-occlusive-therapy, secondary wound closure or meshgraft. 5 Patient had a peripheral ischaemie. 2 Patients had to underwent a Major Amputation. 25% of the patients died during the Hospital stay. There were 10 patients for the follow-up, 3 only by questionnaires and phone calls. There were two more Major amputations postoperative. All patients were free of infection. Only one Patient had to underwent a percutane angioplastie of Stenosis of the anastomosis. After vein harvesting there is a mild to severe lymphedema in 5 of 7 patients, two patients still need Manual lymphmassage. Conclusion: The prostectic vascular graft infection is a technical challenge especially when the distal Aorta is infected, too. The deep vein V. femoralis superficialis is at the Moment the first choice for a Bypass material with a big Diameter. Nearly 100% freedom of infect and patency are garanted. But a stricte praeoperative selection of the patients is necessary because of the high rates of mortality and morbidity. Every alternative method should be included to get the best Treatment in every individual case. Unfortunatelly there is no Goldstandard for the diagnostic and therapy for the deep prostetic vascular graft infection. More Discussion and Research must follow to develope such a Standard.
2

Die multifunktionelle Gefäßprothese - Weiterentwicklung und Optimierung / The multi-functional vascular graft - advancement and improvement

Haacke, Christian January 2009 (has links) (PDF)
Einleitung Müssen im Verlauf einer kardiovaskulären Erkrankung geschädigte Gefäßabschnitte ersetzt werden, stehen den Gefäßchirurgen neben organischen Eigen– oder Fremdmaterial hauptsächlich die Kunststoffe Polytetraflourethylen (PTFE) und Polyethylen-terephtalat (PET, Polyester, Dacron®) zum Gefäßersatz zur Verfügung. Im Zusammenhang mit diesen künstlichen Ersatzmaterialien kommt es allerdings häufig zu Komplikationen. Diese sind besonders nach Rekonstruktion kleiner Gefäße durch die Thrombogenität ihrer Oberflächen und eine übersteigerte Intimahyperplasie bedingt. Ursächlich für einen Misserfolg können außerdem eine ungenügende Dichtigkeit und eine Infektion des Gefäßersatzes sein. Diese Arbeit beschäftigt sich mit der Weiterentwicklung einer "multifunktionellen“ Silikon–beschichteten und Medikamenten-freisetzenden Gefäßprothese, bei der die Oberflächeneigenschaften optimiert wurden. Material und Methoden Herstellung der Prothesen: Gewirkte Polyesterprothesen wurden maschinell mit Silikon beschichtet. Mit Hilfe einer neuen Beschichtungsmaschine wurden die Prothesen zusätzlich von innen mit Silikon betropft. Durch einen nass–chemischen Prozess wurden in einem zweiten Schritt verschiedene Stoffe kovalent an die Oberfläche des Silikons gebunden (Polyvinylpyrrolidon, Polyvinylalkohol, Phosphorylcholin, eine amphotere Oberfläche, Silber und die Kombination von Silber und PVA). Außerdem wurde das Medikament Paclitaxel (Taxol®) in die Silikonmatrix eingebracht. Untersuchung der Eigenschaften: Es wurde die Dichtigkeit nach Beschichtung und zusätzlich der Wasserverlust nach Einstich mit Kanülen und Venenverweilkanülen untersucht und mit dem herkömmlicher Prothesen verglichen (eine PTFE -, eine mit Kollagen beschichtete und eine 3-schichtige PTFE-Polymer – Prothese (Rapidax)). Zusätzlich wurden die antiinfektiösen Eigenschaften der verschiedenen Oberflächen (Silber, amphotere Oberfläche, Kollagen- und Silikon-beschichtete Polyesterprothesen) auf den Prothesen, der Einfluss der an die Prothese gebundenen Moleküle auf die Thrombogenität und die Elution von Paclitaxel, einem Medikament zur Unterdrückung der Intimahyperplasie, untersucht. Ergebnisse Herstellung der Prothesen. Die Umstellung des Beschichtungsvorgangs mit einer 3. Beschichtung von innen konnte realisiert werden. Untersuchung der Eigenschaften: Dichtigkeit: Bei der Untersuchung des Wasserverlustss nach Einstich von Kanülen und Venenverweilkanülen zeigten sich die geringsten Verlustraten bei der Rapidax®-Prothese und die höchsten bei der PTFE–Prothese. Die Silikon–beschichtete und die herkömmliche PET–Prothese erzielten insgesamt ähnliche Ergebnisse Oberflächenthrombogenität: Durch die Beschichtung mit Silikon konnte im Vergleich zur reinen Polyesterprothese und gegenüber den herkömmlichen Prothesen (Dacron®-Gelatine und PTFE) in allen Versuchen eine geringere Gerinnungsaktivierung für die Silikonprothese festgestellt werden. Die zusätzliche Oberflächenmodifizierung von Silikon- und Silberprothesen mit PVA erbrachte niedrigere Gerinnungswerte als die alleinigen Oberflächen. Die antiinfektiöse Oberfläche: Die mit Silber modifizierte Silikon-beschichtete Prothese konnte das bakterielle Wachstum komplett inhibieren. Die amphotere Oberfläche hingegen konnte das bakterielle Wachstum im Vergleich zur reinen Silikonoberfläche nur leicht hemmen. Medikamentenelution: Paclitaxel konnte im Kreislaufmodell und auch im statischen Versuchsaufbau über einen Zeitraum von bis zu 21 Tagen im Humanalbumin nachgewiesen werden. Diskussion Durch die Beschichtung mit Silikon wird eine primäre Dichtigkeit erreicht. Außerdem konnten nun die Prothesen durch die Umstellung des Herstellungsverfahrens in besserer Qualität und schneller hergestellt werden. Es konnte nachgewiesen werden, dass die Eigenschaften der einzelnen Moleküle in der Kombinationsprothese erhalten bleiben: so konnte die Thrombogenität der antiinfektiösen Silberprothese durch das PVA aufgehoben werden. Die Elution des Paclitaxels war unabhängig von der Oberflächenbeschichtung. Alternativ können auch andere Moleküle und Medikamente verwendet werden. Ziel ist nun die Testung dieser Prothese zunächst im Tierversuch und auf lange Sicht in einer klinischen Studie. Insbesondere bietet sich eine vergleichende Studie mit herkömmlichen Prothesen im Dialyseeinsatz an, da die Silikonprothese hinsichtlich der Dichtigkeit besonders bei Venenverweilkanülen mittleren Durchmessers gegenüber PTFE– und einer Polyester-Prothese überzeugen konnte. / Abstract Background: To replace affected blood vessels surgeons might use synthetic prostheses made of polytetraflourethylen (PTFE) and polyethylenterephtalat (PET, Polyester, Dacron®) instead of autologous veins. There are some common complications in conjunction with these prostheses. Major complications are infections, a deficient density, the thrombogenicity of the artificial surfaces and especially after reconstruction of smaller blood vessels the development of intima hyperplasia. The current dissertation describes the improvement of a "multifunctional" silicone-coated and drug-eluting vascular graft. Methods: Fabrication of prostheses: Knitted polyester-prostheses were coated with silicone. The former coating with silicone which was only from outside was completed with an extra coating at the inner side of the prosthesis. For this process we developed a special machine. The coating was followed by a modification with different molecules such as polyvinylpyrrolidone (PVP), polyvinylalcohole (PVA), phosphorylcholine (PC), an amphoteric surface, silver and a combination of silver and PVA. In another processes we inserted the drug paclitaxel in the matrix of the silicone. Analysis of characteristics: We analysed the density, the anti-infectious qualities of the prostheses, the influence of bonded molecules on the thrombogenicity and the drug-elution of paclitaxel. Density: We tested the average leakage and the leakage after puncture with canulas and indwelling venous catheters of the coated prostheses and three conventionally used vascular grafts (one PTFE, one collagen-coated and one prosthesis made of PTFE and another polymer (Rapidax)). Thrombogenicity of surfaces: We analysed the INR, Quick, PTT and fibrinogen after the contact of blood with the different surfaces. Furthermore we determined the amount of fibrinogen adhered platelets and platelet aggregates via FACS and the presence of coagulation activators (fragments of prothrombin F1+ F2) and of fibrinolysis (D-Dimeres) via ELISA (Enzyme-Linked Immunosorbend Assay). Infectivity: We analysed the effectivity of silver and of an amphotere surface on silicone catheters and on silicone prostheses against S. aureus. In an in-vitro experiment we incubated different catheters with a bacterial suspension and quantified the adherent bacteria. In a second experiment we incubated different coated prostheses with a S.aureus xen29 strain and determined the luminescence of the adhered bacteria. Drug elution: In static and dynamic experimental set-ups we detected the concentration of paclitaxel eluted from a prostheses via an Immuno-Assay (Fa. Cardax Pharmaceuticals, Hawaii, USA). This drug should inhibit the intima hyperplasia. Results: Production of prostheses: We realized the restructering of the coating process. Thereby we could save time and silicone. In addition we achieved a constant layer of silicone at the inside of the prostheses. Analysis of characteristics: Density: After puncturing the prostheses with canulas and indwelling venous catheters the Rapidax-prosthesis achieved the lowest and the PTFE the highest leakage. The silicone-coated and the collagen-coated prostheses achieved comparable results with advantages for the silicone-prosthesis. Thrombogenicity: The silicone-coated prostheses caused a lower activation of coagulation than the commonly used vascular grafts (Dacron-Gelatine or PTFE). The modification with PVA could additionally decrease the activation of silicone and silver. Infectivity: The silver-coated catheters and prostheses could completely inhibit the growth of bacteria. The highest growth was detected on the collagen-prostheses. The amphotere surface could achieve a low inhibation. Drug elution: It was possible to detect paclitaxel in the static as well as in the dynamic experimental set-up until the 21th day. Discussion: The coating with silicone could achieve a complete density of the prostheses. Furthermore we now have the ability to produce silicone-coated grafts in a better quality and in a shorter period of time. We could demonstrate that the individual characteristics of the different molecules persist in the combination with other molecules. The coating with PVA for example made it possible to compensate the higher activation of coagulation. Alternatively we could also coat the prostheses with other molecules or drugs. Our ambition is to test the silicone-prostheses in an animal experiment and in a clinical survey. Because of the good results in the density experiment it is conceivable to test our prostheses in conjunction with dialysis.
3

Langzeiterfahrungen mit der silberazetatbeschichteten Polyesterprothese - Ist der prophylaktische Einsatz gerechtfertigt? / What’s silver worth? - Long-term experience with silver acetate-coated polyester grafts

Rußmann, Sonja January 2007 (has links) (PDF)
Was ist Silber wert? Langzeiterfahrung mit der Silberacetat-beschichteten Polyesterprothese EINLEITUNG: Nicht nur zur Behandlung von Protheseninfekten, sondern auch zur Prophylaxe wurden neue silberacetat-beschichtete Gefäßprothesen entwickelt. Die hier vorliegende Studie beschreibt die Sicherheit, Extremitätenerhaltungs- und Infektionsraten nach Implantation der InterGard® Silver Prothese. METHODEN: Es wurden alle Patienten erfasst, bei denen im Zeitraum zwischen 7/1999 und 12/2004 an der Universitätsklinik Würzburg eine silberacetat-beschichtete Polyesterprothese implantiert wurde. Nach Sichtung der OP-Bücher wurden die jeweiligen Verläufe anhand der Aktenlage analysiert. In einer Follow-Up Untersuchung wurde der weitere Langzeitverlauf erfasst. ERGEBNISSE: 585 Patienten erhielten eine Silberprothese. Die OP-Indikation stellte bei 314 Patienten (53,7%) pAVK, bei 155 (26,5%) aortale und periphere Aneurysmen, bei 110 (18,8%) akute Ischämie, und bei 6 (1,0%) ein Bypassinfekt dar. Die Prothese wurde in 210 Fällen in aorto-iliaco-femoraler, in 325 in femoro-distaler und in 50 in extraanatomischer Position oder als Mehretageneingriff implantiert. Postoperative Komplikationen stellten Wundheilungsstörung in 83 (14,2%), operative Revision in 73 (12,5%), Lymphfistel in 58 (9,9%) und eine Nachblutung in 27 (4,6%) Fällen dar. Im Langzeitverlauf traten 35 (6,0%) Protheseninfektionen auf, 27 davon primär und 8 sekundär nach Re-Operation.. Die Gesamt-Infektrate bei aorto-iliaco-femoraler Prothesenposition betrug 1,9% und bei femoro-distaler 8,6% (p<0,05). Die Protheseninfektrate war bei pAVK IV, früherer Revaskularisation, Wundheilungsstörung, Nachblutung und chirurgischer Revision signifikant erhöht (p<0,05). Es ergaben sich Extremitätenerhaltungsraten von 79,8% ohne bzw. 32,0% bei Protheseninfekt nach 5 Jahren. SCHLUSSFOLGERUNG: Die InterGard® Silver Prothese hat sich in aorto-iliaco-femoraler bei jeder Indikation, sowie in peripherer Position bei pAVK IIb bewährt. Bei pAVK IV ist keine Reduktion der Protheseninfekte zu erwarten. / What’s silver worth? - Long-term experience with silver acetate-coated polyester grafts INTRODUCTION: New silver-coated vascular polyester prostheses were not only developed for the treatment of prosthetic graft infections but also for prophylaxis. This study describes safety, limb salvage, patency and infection rates after implantation of the InterGard® Silver polyester graft. METHODS: Included were all patients, who received silver-coated vascular polyester prostheses at University Hospital Würzburg within the period of 07/1999 and 12/2004. The courses of disease were analyzed on the medical records. A follow-up research documented further long-term results. RESULTS: In 585 patients a silver acetate-coated polyester graft was implanted. The indications for prosthetic bypass were: Peripheral arterial occlusive disease in 314 (53.7%) patients, peripheral and aortic aneurysms in 155 (26.5%), urgent ischemia in 110 (18.8%) and prosthetic infection in 6 (1.0%) patients. Prosthetic implantation was performed in aorto-iliaco-femoral position 210 times, in femoro-distal position 325 times and in extra-anatomic or combined aorto-femoro-distal position in 50 cases. Postoperative complications presented as wound healing disorders in 83 cases (14.2%), required surgical revision in 73 (12.5%), lymphatic fistulas in 58 (9.9%) and secondary bleeding in 27 (4.6%) cases. 35 (6.0%) prosthetic infections occurred within observation period, 27 primary and 8 after re-operation. There was a total infection rate of 1.9% in patients, when underwent aorto-iliaco-femoral bypass and one of 8.6% when a bypass in femoro-distal position was received (p<0.05). Prosthetic infection rate for patients with gangrene/ulcer, wound healing disorders, previous revascularisation, secondary bleeding and surgical revision was statistically significantly increased. At 5 years, limb salvage rates were 32,0% for patients suffering from prosthetic infection and 79,8% for patients with non-infected grafts. CONCLUSION: This study shows excellent results for the InterGard® Silver prosthesis in aorto-iliaco-femoral position at every surgical indication as well as in peripheral position in patients with intermittent claudication. In event of pre-existing gangrene/ulcer, reduction of prosthetic infections cannot be expected.
4

Der aortodistale Gefäßersatz bei pAVK - Langzeitergebnisse nach alloplastischer Versorgung / The aortodistal graft in peripheral arterial occlusive disease - Longterm results after alloplastic treatment

Kierchner, Jörg-Joachim January 2007 (has links) (PDF)
Die retrospektive Arbeit untersucht die in der Zeit von Januar 1993 bis Oktober 2002 an der Uniklinik Würzburg implantierten 294 aortodistalen Gefäßprothesen. Dabei erfolgte sowohl eine Auswertung der perioperativen Komplikationen als auch der Langzeitergebnisse. Mit Hilfe von Chi-Quadrat Tests und Kaplan-Meier Berechnungen konnte ein direkter Einfluss unterschiedlicher Faktoren auf die Ergebnisse nachgewiesen werden. In der Diskussion wurden die Ergebnisse internationalen Publikationen gegenübergestellt und mit alternativen Therapiemethoden verglichen. Zusammenfassend lässt sich die aortobifemorale Y-Prothese bei Patienten mit zufriedenstellendem Allgemeinzustand und einer proximal manifestierten pAVK angesichts eines durch andere Verfahren nicht erreichten Risiko-Nutzen Verhältnisses nach wie vor als Goldstandard empfehlen. / This retrospective work examines all 294 aortodistal grafts which were implantated by the surgical section of the university hospital Würzburg from the time of january 1993 till october 2002. Perioperative complications were as well in the centre of interest as longterm results. Chi-Quadrat-Tests and Kaplan-Meier-Statistics showed direct influence of several factors on the results. In the discussion the results were opposed to international publications and compared to alternative treatments. In conclusion the aortobifemoral graft in patients with satisfying general conditions and a proximal manifested pAOD due to the, by other methods never achieved, risk-benefit-ratio can still be adviced as the goldstandard.
5

Der Gefäßprotheseninfekt - Vorschlag einer neuen Klassifizierung und prognostische Bedeutung

Haunit, Claudia January 2008 (has links) (PDF)
Zusammenfassung Einleitung: Tiefe Gefäßprotheseninfektionen stellen eine seltene, jedoch schwerwiegende Komplikation in der rekonstruktiven Gefäßchirurgie dar. Morbidität und Mortalität sind hoch. Thema der vorliegenden Arbeit war die retrospektive Analyse aller Protheseninfektionen, die an der Universitätsklinik Würzburg behandelt wurden. Material und Methoden: Wir befassten uns mit 72 Fällen einer Bypassinfektion im Zeitraum von 1993 - 2002. Ziel war, eine neue Klassifizierung der Bypassinfekte und ihre prognostische Bedeutung herauszuarbeiten. Aufgrund des Zeitpunktes und der vermutlich unterschiedlichen Ursachen bzw. nachfolgenden Eingriffe wurden folgende 5 Gruppen festgelegt: Gruppe Definition 1 Bypassinfekte während des Implantationsaufenthaltes (Frühinfekt) 2 Infekte, die erst nach Entlassung auftraten, ohne zwischenzeitliche Gefäßoperation 3 Bypassinfekte im späteren Verlauf, nach Eingriffen am Gefäßsystem OHNE neuen Bypass 4 Bypassinfekte im späteren Verlauf, MIT Einbringung einer neuen Prothese 5 Auswärtige Bypassimplantation mit Infekt Innerhalb dieser Gruppen verglichen wir verschiedene Schwerpunkte, unter anderem das pAVK Stadium, die Prothesenlokalisation (Anschluss Aorta oder A. iliaca vs. peripher) den Infektionszeitpunkt (innerhalb von 4 Wochen, innerhalb eines Jahres und später), das Keimspektrum, die Amputationsraten, das Procedere nach Protheseninfekt sowie die Mortalitätsraten. Ergebnisse: Das pAVK Stadium 4 (peripherer Gewebedefekt) lag in 55% der Fälle vor, dies bedeutet in 45% der Fälle kam es trotz intakter Peripherie zu einem Bypassinfekt. Somit spielt das pAVK Stadium bei dem Risiko eines Bypassinfektes nicht immer eine tragende Rolle. Bei der Bestimmung des Zeitpunktes zeigte sich ein Infekt der peripheren Prothesen vermehrt innerhalb des ersten Jahres nach Erstimplantation. Bypassinfekte mit zentralem Anschluss oberhalb der Leiste traten im Vergleich dazu später auf. Dominierender Keim war Staphylococcus aureus, ein ORSA, bekannt als besonders virulenter Keim, trat in 16,7% der Fälle auf und zeigte sich vor allem in Gruppe 4 und 5, bei Patienten mit zweitem Bypass und Rezidiveingriffen. Die Mortalität bei Vorliegen eines ORSA Keimes betrug 50% bzw. bei Patienten in Gruppe 4 83%. Dies bedeutet, dass besonders bei Rezidiveingriffen das Risiko für einen Bypassinfekt und für die Selektionierung eines ORSA Keimes erhöht ist. Zum Vergleich trat in Gruppe 1 mit Frühinfekt und ohne zweiten Bypass kein ORSA auf. Die Amputationsrate der 72 Patienten war mit 65,3% hoch. Das primäre Procedere nach Infektauftreten war in 44,4% der Fälle die Explantation der infizierten Kunststoffprothese und Gefäßersatz durch einen Venenbypass. Die Mortalität lag bei insgesamt 30,6%. Konnte der Infekt durch lokale Maßnahmen beherrscht werden (n = 8), lag die Heilungsrate bei 62,5% (5/8) und die Mortalität bei 12,5% (1/8). Zusammenfassung: Diese Arbeit zeigt, wie schwerwiegend auch heute noch, trotz vielfältiger medizinischer Fortschritte, die Infektion einer Gefässprothese ist. Die hohen Amputations- und Mortalitätsraten der Patienten belegt dies. Als bewährte Therapie zeigte sich die Explantation der infizierten Prothese und Gefäßersatz durch einen Venenbypass. Eine Alternative stellt – bei geringer Virulenz des Keimes – die lokale Infektkontrolle durch Débridement dar, hier konnten die höchsten Heilungs- und niedrigsten Mortalitätsraten erreicht werden. Oberstes Ziel nach Entwicklung eines Bypassinfektes sollte die Vermeidung von Rezidiveingriffen und langen Krankheitsverläufen sein, da besonders in ihrem Gefolge mit der Selektionierung eines ORSA Keimes zu rechnen ist und schwerwiegende Fälle mit hoher Mortalität (83%) beobachtet wurden. Auch könnte man bei Rezidiveingriffen die antibiotische Prophylaxe überdenken, um der Selektionierung eines ORSA Keimes vorzubeugen.

Page generated in 0.0554 seconds