• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do potencial fotovoltaico na envoltória de edificações residenciais inseridas no contexto urbano

Silvestre, Silvana Maria Silva January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Arquitetura e Urbanismo, Florianópolis, 2015. / Made available in DSpace on 2016-05-24T17:44:56Z (GMT). No. of bitstreams: 1 338270.pdf: 203285788 bytes, checksum: 6ca03398fa02cd4cbc52da6a15993415 (MD5) Previous issue date: 2015 / O sistema fotovoltaico conectado à rede apresenta-se como uma alternativa promissora para a geração de energia elétrica próximo ao local do consumo, principalmente em um país com grande potencial de irradiação solar como o Brasil. No entanto, a aplicação dos sistemas fotovoltaicos nos centros urbanos pode ser prejudicada pela verticalização das cidades e consequente obstrução solar. Por essa razão, esta dissertação tem como objetivo avaliar níveis de irradiação solar em quatro edificações residenciais inseridas no contexto urbano. O uso de programas para simulação dos mapas de irradiação solar nas envoltórias dessas edificações e a estimativa de geração de energia elétrica através de painéis fotovoltaicos aplicados nessas superfícies fazem parte desta pesquisa de caráter exploratório. O processo para realização do método está dividido em quatro etapas e obedece à seguinte sequência: identificação das tipologias residenciais para os estudos de caso; análise da disponibilidade solar incidente nas envoltórias das edificações; quantificação do potencial de geração de energia; delimitação das áreas úteis nas envoltórias a partir do limite mínimo estabelecido de irradiação solar. Quatro diferentes edificações residenciais foram selecionadas, sendo uma residência com dois pavimentos e três edificações multifamiliares com alturas distintas com três, oito e treze pavimentos tipo de apartamentos. Os modelos foram desenvolvidos no programa Rhinoceros e simulados através do plug-in DIVA, que permitiu a quantificação de irradiação solar nas partes opacas desses edifícios através de mapas de irradiação. Os resultados, para a latitude considerada de 27o S, apresentaram a cobertura (plano horizontal) como a área com maior irradiação solar e com o menor tempo de equivalência entre o valor investido no sistema fotovoltaico e o valor que deixa de ser pago pela energia elétrica da concessionária. Porém, com a verticalização dos edifícios, as áreas de coberturas foram insuficientes para a atender à geração fotovoltaica desejada. As fachadas (plano vertical) com maior disponibilidade de área foram analisadas e, quando orientadas para logradouro, apresentaram uma menor interferência do entorno. A média anual de irradiação de todas as fachadas resultou nos quatro estudos de caso, valores entre 49% e 62% inferiores às médias anuais das coberturas. A delimitação das áreas úteis para geração fotovoltaica, identificadas neste trabalho como as áreas com irradiação solar superior a 679 kWh/m2/ano, desqualificou as fachadas com as orientações SE-S e S-SO para aplicação do sistema fotovoltaico. Os edifícios com dimensionamentos diferentes e não alinhados horizontalmente, mesmo com as fachadas obstruídas, representaram um percentual maior de áreas (úteis) favoráveis para geração de energia. As áreas úteis selecionadas para a residência e o edifício multifamiliar com três pavimentos constituíram apenas as áreas na cobertura (plano horizontal), pois já foram suficientes para geração de energia fotovoltaica desejada. No edifício multifamiliar com oito pavimentos, além da cobertura, fez-se uso do plano vertical de toda a fachada NE-L (frontal), e a geração de energia fotovoltaica correspondeu a 71% do consumo. Com esse caso, observou-se que a disposição dos painéis fotovoltaicos não precisa restringir-se aos pavimentos superiores. Em situações com a fachada limítrofe com logradouro, orientada entre Noroeste e Nordeste, os pavimentos inferiores também apresentaram as áreas úteis para geração fotovoltaica. Na maior edificação, com treze pavimentos, as áreas úteis selecionadas foram a cobertura e os cinco últimos pavimentos das orientações O-NO e N-NE, e com essa configuração passou a gerar energia fotovoltaica correspondente a 57% do consumo. Observou-se que a irradiação solar na envoltória das edificações sofre interferência direta do partido arquitetônico residencial adotado nos centros urbanos, e que é possível, com adequada aplicação de formas e disposições arquitetônicas (e urbanas), obter maiores benefícios da conversão fotovoltaica, aplicada ou integrada às edificações.<br> / Abstract : The photovoltaic system connected to the power grid is a promising alternative for electrical power generation near the consuming premises, especially in a country with great solar irradiation potential such as Brazil. However, the application of photovoltaic systems in urban centers can be impaired by the verticalization of cities, and its consequent solar obstruction. For this reason, this dissertation has as objective to evaluate the levels of solar irradiation in four residential buildings in an urban context. The use of simulation programs of solar irradiation in the surroundings of the buildings and the estimate of electrical power generation using photovoltaic panels applied to these surfaces are also part of this exploratory research. The process of execution of the method is divided in four stages, and follows the sequence: identification of the residential typologies for the case studies; analysis of solar incidence availability in the surroundings of the buildings; quantification of the power generation potential; delimitation of the useful area in the surroundings based on the minimal threshold determined for solar irradiation. Four different residential buildings were selected, being one residence with two floors and three multifamily buildings with different heights of three, eight and thirteen apartment-type floors. The models were developed with the software Rhinoceros, and simulated through the plug-in DIVA, which allowed the quantification of solar irradiation in the opaque areas of these buildings using irradiation maps. The results, for the considered latitude of 27o S, presented the rooftop (horizontal plane) as the area with the greatest solar irradiation, and with the least equivalent time between the value invested in the photovoltaic system and the value saved in payments for the electrical service utility. However, with the building verticalization, the rooftop areas were insufficient to meet the desired photovoltaic generation. The façades (vertical plane) with greater area availability were analyzed and, when oriented to street, presented less interference from the surroundings. The annual irradiation average from all façades resulted, in the four case studies, in values between 49% and 62% less than the annual averages of the rooftops. The delimitation of the useful areas for photovoltaic generation, identified in this work as the areas with solar irradiation greater than 697 kWh/m2/year, disqualified the façades with orientation SE-S and S-SW for photovoltaic system application. The buildings with different dimensionings, and not horizontally aligned, even with obstructed façades, presented a greater percentage of useful area favorable to power generation. The useful areas selected in the residence and in the multifamily building with three floors consisted only of the rooftop (horizontal plane), because they were already sufficient for the desired photovoltaic power generation. In the multi-family building with eight floors, besides the rooftop, the whole vertical plane of the NE-E (frontal) façade was used, and the photovoltaic power generation corresponded to 71% of the consumption. In this case, it was observed that the disposition of the photovoltaic panels does not need to be restricted to the upper floors.In situations with façades adjacent to patios, oriented between Northwest and Northeast, the lower floors also presented useful areas for photovoltaic generation. In the tallest building, with thirteen floors, the selected useful areas were the rooftop and the five highest floors with orientations W-NW and N-NE, and with this configuration the photovoltaic power generation corresponded to 57% of the consumption. It was observed that the solar irradiation in the surroundings of the buildings suffers a direct interference from the architectural standards adopted in urban areas, and that it is possible, with adequate application of architectural (and urban) forms and dispositions, to obtain greater benefits from the photovoltaic conversion, applied or integrated in the buildings.
2

Short-term solar irradiance forecasting and photovoltaic systems performance in a tropical climate in Singapore

Nobre, André Maia January 2015 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2015. / Made available in DSpace on 2016-05-24T17:37:07Z (GMT). No. of bitstreams: 1 338190.pdf: 9968372 bytes, checksum: e1c28dfcf84e191f0457a82aa5715399 (MD5) Previous issue date: 2015 / A humanidade usou e continua consumindo em grande quantidade os recursos não-renováveis do planeta como petróleo, gás natural e carvão mineral para suprir suas necessidades energéticas. Somente nas últimas duas décadas que outras fontes de energia renováveis, como a solar fotovoltaica e a eólica, passaram a se tornar relevantes na geração de energia elétrica em nível mundial. Instalações de sistemas fotovoltaicos ao redor do mundo atingiram crescimento da ordem de 40% durante os últimos quinze anos. Entretanto, a grande maioria destes sistemas, (acima de 90%), estão localizados em regiões onde o recurso solar não é tão abundante, ou seja, fora da região dos trópicos do planeta. Devido a este fato, ao tentar incorporar a energia solar fotovoltaica às redes elétricas, uma pergunta que sempre surge está relacionada a variação desta forma de geração de energia elétrica com a produção alternante durante o dia devido ao movimento das nuvens e total ausência no período noturno. Mesmo assim, em alguns países, já se atinge percentuais em torno de 5 a 10% de contribuição da energia elétrica proveniente de energia solar fotovoltaica. Passa a ser desafiador a inserção dessa fonte de energia à rede, de maneira intensiva, em paralelo com os recursos já existentes (em sua maioria ainda de origem fóssil). Nesta tese, foi avaliada a previsão do recurso solar em curtíssimo prazo (como 15-min, 30-min e uma hora) para uma região tropical do planeta, neste caso em Cingapura, ilha que se localiza próxima à linha do equador, no Sudeste Asiático. Esta tese foca em métodos existentes de previsão de irradiância, mas também explora uma nova proposta híbrida, adaptada a uma localidade tropical. Além das previsões de irradiação solar, simulações de sistemas fotovoltaicos e o cálculo de seu desempenho foram estudados e avaliados de modo a se prever quanto de energia elétrica é produzida com a mesma antecedência dada nos produtos de previsão do recurso solar. A influência da gaze de queimada foi um fenômeno particular, comum na Cingapura de hoje, que afeta o desempenho de sistemas fotovoltaicos e que foi investigado em detalhe. Todo o trabalho foi validado por redes detalhadas de estações meteorológicas em solo e também através de monitoramento de sistemas fotovoltaicos por toda Cingapura.<br> / Abstract : Humanity has used and continues to consume in great proportion non-renewable energy resources of the planet such as oil, natural gas and coal in order to fulfil its energy needs. It was only during the past two decades that other sources of renewable energy such as solar photovoltaics (PV) and wind energy became somewhat relevant towards electricity generation in the world. PV installations worldwide have reached a compound annual growth rate of ~40% for the last fifteen years. However, the great majority of these systems (over 90% of them) are located where the solar energy resource is not the most abundant - outside of the tropical regions of the planet. While trying to incorporate solar energy PV into electrical power grids, one common question which arises is related to the variable aspect of this form of energy generation - with alternating production during the day due to cloud motion, and total absence during night time. Nonetheless, in some countries, contribution ratios of 5 to 10% of electrical energy from solar PV have been achieved. It becomes then challenging to integrate this source of energy into grids in a professional way, in parallel with existing resources (mostly still fossil-fuel-based). In this thesis, short-term forecasting (for time horizons such as 15-min, 30-min and 1-hour) of the solar resource was investigated in a tropical region of the world - in Singapore, 1° North of the Equator, in Southeast Asia. This thesis focuses on existing methods for irradiance forecasting, but also explores a novel Hybrid proposal, tailored to the tropical environment at hand. Beyond the forecast of the solar energy irradiance ahead of time, PV system simulation and performance assessment were studied and evaluated with the goal of predicting how much electricity is produced in the same time frame given by the solar irradiance forecasting products. The influence of haze was a particular phenomenon, common in today?s Singapore, which affects PV system performance and which was investigated in detail. All work has been validated by a comprehensive network of ground-based meteorological stations, as well as by various PV system monitoring sites throughout Singapore.

Page generated in 0.1131 seconds