• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação eletrocardiográfica em felinos domésticos destinados a gonadectomia eletiva

SANTOS, Breno Menezes dos 28 February 2018 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2018-09-04T15:43:37Z No. of bitstreams: 1 Breno Menezes dos Santos.pdf: 9877941 bytes, checksum: 1b8d20328a444f653babae80e8afea97 (MD5) / Made available in DSpace on 2018-09-04T15:43:37Z (GMT). No. of bitstreams: 1 Breno Menezes dos Santos.pdf: 9877941 bytes, checksum: 1b8d20328a444f653babae80e8afea97 (MD5) Previous issue date: 2018-02-28 / The electrocardiogram (ECG) is a sensitive and specific technique for the identification and classification of cardiac arrhythmias. In addition, the ECG may also suggest increased cardiac chambers, rhythm monitoring during surgeries and chemical restraint, diagnostic aid for structural heart disease, electrolyte disturbances, metabolic diseases, and pericardial effusion. Although it is a diagnostic technique already established in the veterinary routine, it is necessary studies that characterize some of its variables, in view of the scarcity of scientific material addressing this subject specifically in felines of company. In this context, the present study aimed to evaluate the electrocardiogram and to standardize the precordial leads in domestic cats for elective gonadectomy. Eighty healthy and adult animals with surgical indication for elective gonadectomy, from the clinical care routine performed at University Veterinary Hospital -UAG (UFRPE), were evaluated. The electrocardiogram was performed using the computerized method, with standardized equipment at sensitivity 1cm = 1mv and velocity of 50mm / s. The results obtained expressed as mean and standard deviation were HR: 194.20 ± 31.48 (bpm); P wave: 0.04 ± 0.00 (s) X 0.11 ± 0.03 (mV); PR interval: 0.07 ± 0.01 (s); QRS complex: 0.04 ± 0.00 (s) X 0.34 ± 0.21 (mV); QT interval: 0.16 ± 0.02 (s); T wave 0.14 ± 0.07 (mV); R wave (rV2): 0.17 ± 0.10 (mV); S wave (rV2): 0.12 ± 0.10 (mV); R wave (V2): 0.30 ± 0.21 (mV); S wave (V2): 0.10 ± 0.11 (mV); R wave (V4): 0.22 ± 0.21 (mV); S wave (V4): 0.03 ± 0.07 (mV); RC: sinus rhythm (92.5%), ST segment: isoelectric (92.5%), electric axis: 91.5% (within normal range); polarity of the T wave (rV2): positive (82.5%), polarity of the T wave (V2): positive (95%); polarity of the T wave (V4): positive (93.7%), polarity of the T wave (V10): negative (87.5%). It was verified that the electrocardiographic changes present in the preoperative examination of healthy cats present a significant frequency and that the majority of the evaluated animals present positive T-wave polarity in the pre-cordial leads rV2, V2 and V4, and negative in V10. It was also concluded that all animals evaluated had R-waves smaller than 0.5 mV in the rV2 lead, and S-waves smaller than 0.5 mV in leads rV2, V2 and V4, raising a probable hypothesis that said waves in these leads should be less than this value in domestic felines. / O eletrocardiograma (ECG) é uma técnica sensível e específica para a identificação e classificação das arritmias cardíacas. Além disso, o ECG também pode sugerir aumento de câmaras cardíacas, monitoramento do ritmo durante cirurgias e contenção química, auxílio diagnóstico para cardiopatias estruturais, distúrbios eletrolíticos, doenças metabólicas, além de efusão pericárdica. Apesar de ser uma técnica diagnóstica já estabelecida na rotina veterinária, torna-se necessário estudos que padronizem algumas de suas variáveis, em vista da escassez de material científico abordando esse tema especificamente em felinos de companhia. Dentro desse contexto, o presente estudo teve como objetivo avaliar o eletrocardiograma e caracterizar as derivações precordiais em gatos domésticos destinados a gonadectomia eletiva. Foram avaliados 80 animais adultos e saudáveis com indicação cirúrgica para gonadectomia eletiva, provenientes da rotina de atendimento clínico realizado no Hospital Veterinário Universitário -UAG (UFRPE). O eletrocardiograma foi realizado por meio do método computadorizado, com equipamento padronizado na sensibilidade 1cm =1mv e velocidade de 50mm/s. Os resultados obtidos expressos em média e desvio padrão foram FC: 194,20 ± 31,48(bpm); onda P: 0,04 ± 0,00 (s) X 0,11 ± 0,03 (mV); intervalo PR: 0,07 ± 0,01 (s); complexo QRS: 0,04 ± 0,00 (s) X 0,34 ± 0,21 (mV); intervalo QT: 0,16 ± 0,02 (s); onda T 0,14 ± 0,07 (mV); onda R (rV2): 0,17 ± 0,10 (mV); onda S (rV2): 0,12 ± 0,10 (mV); onda R (V2): 0,30 ± 0,21 (mV); onda S (V2): 0,10 ± 0,11 (mV); onda R (V4): 0,22 ± 0,21(mV); onda S (V4): 0,03 ± 0,07 (mV); RC: ritmo sinusal (92,5%), segmento ST: isoelétrico (92,5%), eixo elétrico: 91,5% (dentro da normalidade); polaridade da onda T (rV2): positiva (82,5%), polaridade da onda T (V2): positiva (95%); polaridade da onda T (V4): positiva (93,7%), polaridade da onda T (V10): negativa (87,5%). Verificou-se que as alterações eletrocardiográficas presentes no exame pré operatório de felinos saudáveis apresentam frequência significativa e que a maioria dos animais avaliados apresentam polaridade da onda T positiva nas derivações pré cordiais rV2, V2 e V4, e negativa em V10. Conclui-se também que todos animais avaliados apresentaram ondas R menores que 0,5 mV na derivação rV2, e ondas S menores que 0,5 mV nas derivações rV2, V2 e V4, levantando uma hipótese provável, que as referidas ondas nestas derivações devem ser menores que este valor em felinos domésticos.

Page generated in 0.0501 seconds