Spelling suggestions: "subject:"Gr?ficou dde controle"" "subject:"Gr?ficou dee controle""
1 |
Grafico misto de controle da media com amostragem em dois estagiosSampaio, Elvis dos Santos 20 July 2012 (has links)
Made available in DSpace on 2015-03-03T15:28:33Z (GMT). No. of bitstreams: 1
ElvisSS_DISSERT.pdf: 714691 bytes, checksum: 14d53d32eb67e048150da6da7ea2ee1d (MD5)
Previous issue date: 2012-07-20 / This paper proposes a new control chart to monitor a process mean employing a combined npx-X control chart. Basically the procedure consists of splitting the sample of size n into two sub-samples n1 and n2 determined by an optimization search. The sampling occur in two-stages. In the first stage the units of the sub-sample n1 are evaluated by attributes and plotted in npx control chart. If this chart signs then units of
second sub-sample are measured and the monitored statistic plotted in X control chart (second stage). If both control charts sign then the process is stopped for adjustment. The possibility of non-inspection in all n items may promote a reduction not only in the cost but also the time spent to examine the sampled items. Performances of the current proposal, individual X and npx control charts are compared. In this study the
proposed procedure presents many competitive options for the X control chart for a sample size n and a shift from the target mean. The average time to sign (ATS) of the current proposal lower than the values calculated from an individual X control chart points out that the combined control chart is an efficient tool in monitoring process mean. / Esta disserta??o prop?e um novo gr?fico (ou procedimento) de controle para monitorar a centralidade de um processo (m?dia) por meio da jun??o dos gr?ficos X e npx. Basicamente o procedimento consiste em dividir a amostra de tamanho n em duas (n1 e n2), definidas pelo processo de otimiza??o. Realiza-se a amostragem em dois est?gios. No primeiro est?gio conta-se o n?mero de itens n?o conformes amostra
de tamanho n1 por meio do gr?fico npx. Caso haja um n?mero excessivo de itens n?o conformes, segue-se para o segundo est?gio da amostragem, onde calcula-se a m?dia X
da amostra de tamanho n2. A possibilidade de n?o inspecionar todos os itens reduz tanto o custo quanto o tempo gasto para inspecionar os itens da amostra. Descreve-se a metodologia de constru??o, avalia??o e o funcionamento do gr?fico aqui proposto, e com o aux?lio do software estat?stico Rc e feito um estudo comparativo entre os gr?ficos individuais X e npx e o gr?fico misto. Neste estudo verificou-se que o procedimento
proposto fornece v?rias op??es concorrentes com o gr?fico X para um dado tamanho de amostra n e um desvio na m?dia . Os valores do tempo esperado at? o sinal (TES)
inferiores aos provenientes do gr?fico individual X evidenciaram que o gr?fico misto ? uma ferramenta eficaz no monitoramento de processos capaz de substituir o gr?fico da m?dia
|
2 |
Utiliza??o do controle estat?stico do processo para monitoramento do peso m?dio de c?psulas de Tuberculost?ticos: estudo de caso no NUPLAM- RNFerreira, Paula de Oliveira 29 August 2008 (has links)
Made available in DSpace on 2014-12-17T14:52:39Z (GMT). No. of bitstreams: 1
PaulaOF.pdf: 1749658 bytes, checksum: c5a7f0123f17bea5eee66bccfbc7edd0 (MD5)
Previous issue date: 2008-08-29 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / This Master Thesis presents a case study on the use of Statistical Process Control (SPC) at the N?cleo de Pesquisas em Alimentos e Medicamentos (NUPLAM). The SPC basic tools have been applied in the process of the tuberculost?ticos drugs encapsulation, primarily concerning the objective to choose, between two speeds, which one
is the best one to perform the tuberculostatics encapsulation. Later on, with the company effectively operating, the SPC was applied intending to know the variability of the process and, through the tracking of the process itself, to arrive at an estimated limit for the control of
future lots of tuberculostatics of equal dosage. As special causes were detected acting in the process, a cause-and-effect diagram was built in order to try to discover, in each factor that composes the productive process, the
possible causes of variation of the capsules average weight. The hypotheses raised will be able to serve as a base for deepened the study to eliminate or reduce these interferences in the process. Also a study on the capacity of the process to attend the specifications was carried out,
and this study has shown the process?s inaptitude to take care of them. However, on the side of NUPLAM exists a real yearning to implant the SPC and consequently to improve the existing quality already present on its medicines / Esta disserta??o apresenta um estudo de caso sobre a utiliza??o do Controle Estat?stico do Processo (CEP) no N?cleo de Pesquisas em Alimentos e Medicamentos (NUPLAM). As ferramentas b?sicas do CEP foram aplicadas no processo de encapsulamento de tuberculost?ticos primeiramente com o objetivo de escolher entre duas velocidades qual a melhor para a realiza??o do encapsulamento dos tuberculost?ticos. Posteriormente, com a empresa efetivamente funcionando, o CEP foi aplicado com o intuito de conhecer a variabilidade do processo e atrav?s do monitoramento do mesmo chegar a um limite de controle estimado para o controle de lotes futuros de tuberculost?ticos que possuam a mesma dosagem do tuberculost?tico monitorado. Como foram detectadas causas especiais atuando no processo, um diagrama de causa-e-
efeito foi constru?do a fim de tentar descobrir em cada fator que comp?e o processo produtivo as poss?veis causas de varia??o do peso m?dio das c?psulas. As hip?teses levantadas poder?o servir de base para um estudo mais aprofundado para a elimina??o ou redu??o dessas interfer?ncias no processo. Tamb?m foi realizado um estudo sobre a capacidade do processo em atender ?s
especifica??es o qual se mostrou incapaz de atend?-las. Contudo, existe por parte do NUPLAM um real anseio em implantar o CEP e conseq?entemente melhorar a qualidade j?
existente em seus medicamentos
|
Page generated in 0.0941 seconds