• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Système inertiel de stockage d'énergie couplé au générateur photovoltaïque et piloté par un simulateur temps réel / Flywheel Energy Storage System coupled to a Photovoltaic power plant and managed by a real time simulator

Abbezzot, Cédric 15 December 2014 (has links)
Le sujet s'inscrit dans la stratégie d'augmentation de la pénétration des énergies renouvelables dans les réseaux électriques, en particulier ceux qui sont faiblement interconnectés, tels que les réseaux électriques insulaires. Une limite de pénétration des énergies intermittentes de 30% en puissance instantanée dans ces réseaux a été fixée par la loi française. Pour permettre de dépasser cette limite, une solution est de coupler les sources de production décentralisée et intermittente avec du stockage.Dans cette thèse, nous nous sommes intéressés au volant d’inertie, système de stockage permettant de convertir l’énergie électrique sous forme cinétique et vice versa. Celui-ci a en effet un nombre de cycles charge/décharge important en comparaison avec une batterie électrochimique et peut être utilisé pour lisser la production photovoltaïque. La fluctuation de l’énergie photovoltaïque est en effet faiblement prédictible au cours du temps et elle ne peut pas être contrôlée, notamment sa chute de production. La production photovoltaïque peut chuter jusqu’à 80 % de la puissance maximale en 30 secondes, et déstabiliser ainsi le réseau électrique. Le réseau électrique insulaire, tel que celui de la Corse, n’est pas interconnecté au réseau électrique continental. Les réseaux non – interconnectés sont plus fragiles et moins stables. Ainsi, le développement massif des centrales photovoltaïques peut faire fluctuer la fréquence et la tension du réseau. Le volant d’inertie a l’avantage de posséder un faible temps de réponse (quelques centaines de millisecondes). Cependant, il a une capacité énergétique moindre. Nous allons donc exploiter les avantages du volant d’inertie en le gérant en temps réel avec un calculateur approprié. Un volant d’inertie d’une puissance de 15 kVA et d’une capacité énergétique de 112 Wh a été caractérisé et testé à l’INES Chambéry en utilisant un simulateur réseau temps réel (RTLab®), un calculateur temps réel dSPACE® et une centrale PV. Le système de stockage est composé d’une machine électrique asynchrone et d’un volant d’inertie cylindrique en acier. Le logiciel Matlab/Simulink® est utilisé pour implémenter les lois de commande nécessaires à son pilotage. Dans cette thèse, le banc de test est présenté ainsi que les résultats sur les services système (lissage de puissance, régulation de la fréquence et de la tension). Trois méthodes de lissage de puissance sont présentées et évaluées (lissage avec une fonction de transfert, lissage avec limiteur de pente et lissage n’utilisant pas aucune fonction de lissage). La troisième méthode n’utilisant ni une fonction de transfert, ni une fonction limitant la pente des variations, nécessite moins de paramètres et s’avère plus optimale et plus robuste. Un volant d’inertie avec une autre technologie de machine électrique (la machine à réluctance variable) a été également caractérisé. C’est une Alimentation Sans Interruption (ASI), sur laquelle des paramètres tels que l’autodécharge et les rendements du système (en charge, en décharge et au repos) ont pu être mesurés. / The subject is part of the strategy to increase the penetration of renewable energy in power systems, particularly those that are poorly interconnected, such as island grids. A limit of penetration of intermittent energy by 30% in instantaneous power in these electrical grids was set by a French law. To help overcome this limitation, a solution is to couple the sources of decentralized and intermittent generation with energy storage systems. In this thesis, we are interested in flywheel energy storage systems (FESS) that converts electrical energy in kinetic energy form and vice versa. FESS have a number of cycles charge / discharge large compared with electrochemical batteries and can be used to smooth the photovoltaic power generation. The fluctuation of photovoltaic instantaneous power is indeed weakly predictable over time and it cannot be controlled, including its production fall. PV production can decrease up to 80% of its maximum power in 30 seconds, and so destabilize the grid. The island grids, such as that of Corsica, are not interconnected to the mainland power grid. The non - interconnected grids are more fragile and less stable. Thus, the massive development of photovoltaic power plants can cause fluctuations in the frequency and voltage. The flywheel has the advantage of having a low response time (a few hundred milliseconds). However, it has a lower energy capacity. The benefits of FESS are used by managing it in real time with an appropriate computer. A flywheel with a power of 15 kVA and an energy capacity of 112 Wh was characterized and tested at INES Chambery using a real time grid simulator (RTLab®), a real-time computer (dSPACE®) and a PV power plant. The storage system is composed by an asynchronous electrical machine and a cylindrical steel flywheel. The Matlab Simulink / software is used to implement the control laws necessary for its control. In this thesis, the test bench is presented and the results of ancillary services (power smoothing, frequency and voltage regulation). Three power smoothing methods are discussed and evaluated (smoothing with a transfer function, with a slope limiter function and a method not using any smoothing function). The third method uses neither a transfer function, nor a function that limits the slope variations, requires fewer parameters, and is more optimal and more robust. A flywheel with another electrical machine technology (the switched reluctance machine) has also been characterized. This is an Uninterruptible Power Supply (UPS) on which parameters such as self-discharge and efficiencies (charging mode, discharging mode and standby mode) were measured.
2

Design and Performance Evaluation of Sub-Systems of Grid-Connected Inverters

Karuppaswamy, Arun B January 2014 (has links) (PDF)
Grid-connected inverters have wide application in the field of distributed generation and power quality. As the power level demanded by these applications increase, the design and performance evaluation of these converters become important. In the present work, a 50 kVA three-phase back-to-back connected inverter with output LCL filter is built to study design and performance evaluation aspects of grid-connected inverters. The first part of the work explores the split-capacitor resistive-inductive (SC-RL) passive damping scheme for the output LCL filter of a three-phase grid-connected inverter. The low losses in the SC-RL scheme makes it suitable for high power applications. The SCRL damped LCL filter is modelled using state space approach. Using this model, the power loss and damping are analysed. A method for component selection that minimizes the power loss in the damping resistors while keeping the system well damped is proposed. Analytical results show the losses to be in the range of 0.05-0.1% and the quality factor to be in the range of 2.0-2.5. These results are validated experimentally. In the second part of the work, a test method to evaluate the thermal performance of the semi-conductor devices of a three-phase grid-connected inverter is proposed. The method eliminates the need for high power sources, loads or any additional power converters for circulation of power. Only energy corresponding to the losses is consumed. The capability of the method to evaluate the thermal performance of the DC bus capacitors and the output filter components is also explored. The method can be used with different inverter configurations -three-wire or four-wire and for different PWM techniques. The method has been experimentally validated at a power level of 24kVA. In the third part of the work, the back-to-back connected inverter is programmed as a hardware grid simulator. The hardware grid simulator emulates the real-time grid and helps create grid disturbances often observed at the point of common coupling in an ac low voltage grid. A novel disturbance generation algorithm has been developed, analysed and implemented in digital controller using finite state machine model for control of the grid simulator. A wide range of disturbance conditions can be created using the developed algorithm. Experimental tests have been done on a linear purely resistive load, a non-linear diode-bridge load and a current-controlled inverter load to validate the programmed features of the grid simulator.

Page generated in 0.0491 seconds