Experimental study of zeotropic refrigerant mixture HFC-407C as a replacement for HCFC-22 in refrigeration and air-conditioning systems

Mirza-Tolouee, Changiz M., n/a January 2006 (has links)
HCFC-22 is the world�s most widely used refrigerant. It serves in both residential and commercial applications, from small window units to large water chillers, and everything in between. Its particular combination of efficiency, capacity and pressure has made it a popular choice for equipment designers. Nevertheless, it does have some ODP, so international law set forth in the Montreal Protocol and its Copenhagen and Vienna amendments have put HCFC-22 on a phase out schedule. In developed countries, production of HCFC-22 will end no later than the year 2030. Zeotropic blend HFC-407C has been established as a drop-in alternative for HCFC-22 in the industry due to their zero Ozone Depletion Potential (ODP) and similarities in thermodynamic properties and performance. However, when a system is charged with a zeotropic mixture, it raises concerns about temperature glide at two-phase state, differential oil solubility and internal composition shift. Not enough research has been done to cover all aspects of alternative refrigerants applications in the systems. This research intended to explore behavior of this alternative refrigerants compare to HCFC-22 and challenges facing the industry in design, operation service and maintenance of these equipments. The purpose of this research is to investigate behavior of R407C refrigerant in chiller systems. This includes performance and efficiency variations when it replaces R22 in an existing system as well as challenges involved maintaining the system charged with R407C. It is a common practice in the industry these days to evacuate and completely recharge when part of the new refrigerant blend was leaked from the system. This has proved to be extremely costly exercise with grave environmental ramifications. This research is intended to address challenges faced in the real world and practical terms. Theoretical and experimental approaches used as a methodology in this work. The system mathematically modeled to predict detailed system performance and effect of the leak at various conditions. To make this feasible and accurate enough, two separate approaches made, first system performance for pure R22 and R407C, and second system subjected to range of leak fractions. The earlier model was relatively straight forward when compared to the latter. Modeling a system charged with R407C ternary mixture and subjected to range of leaks posed enormous challenges. A sophisticated experimental test apparatus was also designed and built. Comprehensive and detailed tests at various conditions were conducted with special attention on instrumental accuracy and correct methodology. The first part has been successfully modeled and predicted all the factors and performance with excellent accuracy when compared to the test results. In these approaches pure refrigerants R22 and R407C were used and simulated the system behavior at range of conditions. However, the second part was the most challenging ever. Comprehensive leak process simulations produced trends of R32/R125/R134a composition change as function of rate of leak. Starting from this point, equations have been created to represent the composition change as function of percentage of the leak. The system thermodynamic cycle was also modeled to calculate capacity, power input and COP at the range of the conditions. Despite many affecting parameters and complexity of the model, the mathematical model successfully predicted the test outcome with a very reasonable accuracy, averaging around 3% with some times reaching to 5 to 6%. On the experimental stage the system charged with the new HFC-407C was deliberately subjected to refrigerant leak at various leak stages. The aim was to objectively determine to what extend the gas leak can be still acceptable without going through the expensive complete gas charge. The effect of leak was tested and verified at 10% steps, from 10% up to 50% mass fraction for the total charge. It has been observed that at the leaks beyond 30%, the adverse effect on the capacity becomes more significant, from 8 to about 15% decrease. While the power input decreased at slower pace, from 3% up to about 8% depending on the test conditions. This translated to COP decrease ranging from 4 to about 7%. This capacity loss and efficiency decrease are significant figures which suggests that the system, here chiller, can not be allowed to degrade the performance to that extend and still continue operating.
2

An evaluation of the phase-out management system of an ozone depleting substance HCFC-22 and its environmental and socioeconomic implications in Botswana

Kudoma, Bongayi 01 1900 (has links)
Climate change and ozone depletion are topical challenges the world over and are both attributed mainly to human activities, particularly emissions of ozone depleting substances (ODSs). One such substance is chlorodifluoromethane (HCFC-22), a cheap, widely used refrigerant with a high global warming potential of 1780. Botswana is a signatory to the Montreal Protocol (MP), which guides international efforts to phase-out HCFC-22 and requires signatories to develop and implement a country-level Hydrochlorofluorocarbon Phase-out Management Plan (HPMP). This study, which used a mixed methods approach, was conducted to evaluate the phase-out of HCFC-22 management strategies and their environmental and socioeconomic implications in Botswana. A census of nine HCFC-22 importing companies was conducted and probability sampling proportional to size was used to select a sample of 159 respondents from the Department of Meteorological Services, HCFC-22 importers, customs officers from 20 purposively selected Botswana entry ports and HCFC-22 consumers from the importing companies. Category-specific respondent questionnaires and interview guides, site visits and assessment of records were used to gather data. Of particular interest were the annual HCFC-22 importation figures for each company, the Botswana Unified Revenue Services and the National Ozone Unit, as well as the level of compliance of the companies’ HCFC-22 phase-out management practices with relevant national regulations, the Botswana HPMP and the MP resolutions. Botswana’s HCFC-22 importers were found to be moderately to highly compliant to nonregulatory elements rather than regulatory elements. Overall, HCFC-22 consumption decreased from the baseline to 10.5% for the first stage (2013-2015), which was slightly more than the 10% reduction expected. A steady decrease in HCFC-22 consumption was noted towards the 35% target for 2020, largely due to awareness-raising initiatives directed at the surveyed stakeholders. Absolute HCFC-22 consumption dropped by approximately 510400 kgs from 2011-2017 or 28072 ozone depleting potential saved. On the downside, gaps were identified in the industry-wide quota-system, data reporting, prevention of illegal ODS trade, service technician training, user knowledge of alternatives and disposal of ODS equipment. The study recommends the use of a planning, policy formulation and implementation framework that integrates and balances three fundamentals, namely, stakeholder involvement, the process and the plan enablers.