• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 218
  • 75
  • 24
  • 21
  • 12
  • 12
  • 10
  • 9
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 481
  • 154
  • 110
  • 104
  • 89
  • 65
  • 56
  • 56
  • 53
  • 49
  • 43
  • 38
  • 37
  • 35
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Power Quality Analysis of a 110 MW Wind Farm in a 130 kV Switchyard

Näslund, My January 2012 (has links)
Good power quality is not only determined by uninterruptable power supply, voltage deviations also affect the function of the network and the equipment connected. Electromagnetic disturbances as flicker, harmonics, interharmonics and unbalance are decreasing the power quality. How are the measurement methods and restrictions stated, to keep the voltagedeviations within reasonable limits and thereby maintaining the networkfunction? Lillgrund wind farm has power quality restrictions set by E.ON Elnät to fulfil in the connection point to the subtransmission network. In addition isa fault ride through requirement set by SVK. All equipment connected tothe network are introducing voltage changes, which can be measured at the point of connection. The scope of the thesis has been to explicitly determine Lillgrund‟s emissions. Three-phase voltage and current measurements have been performed, with measurement systems comprising different bandwidth, to analyse the power quality parameters.Comparisons between standard documentation and technical specifications have been made in order to precise what is considered as good power quality and how it can be measured accurately.
182

Heinrich Wilhelm Ernst and his Contributions to the Development of Left-hand pizzicato and Harmonics.

Wilczkowski, Tobias January 2011 (has links)
From the middle of the eighteenth century, the use of left-hand pizzicato and harmonics began to become more common in violin playing. Over time, these techniques underwent substantial developments thanks to several different violinists, among others Heinrich Wilhelm Ernst. These developments, however, have not been adequately investigated or documented, and in general, ignorance and misconceptions prevail regarding who contributed what, as well as to the significance of these individual contributions.This thesis attempts to present Ernst's contributions in this area, and also advance that his lack of adequate recognition is unfair. In order to do this, a more complete and chronologically accurate review of the development of left-hand pizzicato and harmonics from the beginning of their development has been drawn up. This has been done through critical reviews and comparisons of different contemporary sources such as musical journals, violin methods and musical scores.The conclusion has been drawn that Ernst contributed to the development of left-hand pizzicato and harmonics to a greater extent than has been adequately recognised. The importance of his role in this development is partially due to the number of his individual contributions, but primarily because he enabled the violin to play the role of several independent instruments played simultaneously in a more advanced fashion, which has arguably changed the outlook of the instrument.
183

Implementation and Evaluation of a RF Receiver Architecture Using an Undersampling Track-and-Hold Circuit / Implementation och utvärdering av en RF-mottagare baserad på en undersamplande track-and-hold-krets

Dahlbäck, Magnus January 2003 (has links)
Today's radio frequency receivers for digital wireless communication are getting more and more complex. A single receiver unit should support multiple bands, have a wide bandwidth, be flexible and show good performance. To fulfil these requirements, new receiver architectures have to be developed and used. One possible alternative is the RF undersampling architecture. This thesis evaluates the RF undersampling architecture, which make use of an undersampling track-and-hold circuit with very wide bandwidth to perform direct sampling of the RF carrier before the analogue-to-digital converter. The architecture’s main advantages and drawbacks are identified and analyzed. Also, techniques and improvements to solve or reduce the main problems of the RF undersampling receiver are proposed.
184

Voltage Sag Ride-Through and Harmonics Mitigation for Adjustable Speed Drives using Dual-Functional Hardware

Salib, Anton Samir January 2006 (has links)
Great portion of today's industry are <em>Adjustable Speed Drives</em> (<em>ASD's</em>) operated in order to fulfill certain processes. When these processes are critical ones or sensitive to voltage disturbances, that might take place due to inserting high load in an area near to the Point of Common Coupling (<em>PCC</em>) of the process or due to a short term outage, few tens of thousands up to millions of dollars will be lost once such interruptions (voltage sags) take place as a result of the process failure. On the other hand, a distorted voltage waveform at the PCC for some sensitive process might malfunction as a result of the high harmonic content of the voltage waveform. Utilities are required to deliver as pure as possible sinusoidal voltage waveform according to certain limits; thus, they might apply fines against the consumers who are responsible for producing high amounts of current harmonics that affect the voltage wave shape at the <em>PCC</em> in order to force them to improve the consumer's load profile by adding filters at <em>PCC</em> for instance. Utilities are charging the consumers who are drawing power at poor power factor as well. <br /><br /> This thesis presents an <em>ASD</em> retrofitted with a dual-functional piece of hardware connected in series to its <em>DC-link</em> that is capable of handling the previously two mentioned problems. In other words, hardware that is capable of providing <em>voltage sag ride-through</em> during the voltage sag conditions on one side, on the other side, during the normal operating conditions, it is capable to mitigate the harmonic contents of the drawn current by the ASD's rectifier and to improve the power factor. <br /><br /> Survey on voltage sag ride-through for ASD's approaches are presented in the literature has been made. Approaches are classified as the topology utilized; first, topologies that utilizes energy storage elements that store energy to compensate the DC-link voltage with during the voltage sags, second, topologies retrofitting the DC-link itself with additional hardware to compensate the DC-link voltage. The first group is capable to provide voltage compensating during the full outages while the second can't. The presented voltage sag ride-through work of this thesis belongs to the second group. <br /><br /> Boost converter has been used as the hardware to compensate the DC-link voltage because of its simplicity and cheap price. An adaptive linear network (ADALINE) is investigated as the detection system to detect the envelope of the input voltage waveform. Once the envelope of the voltage goes below a certain level, the boost converter is activated to compensate the difference between voltage set point and the actual DC-link voltage. Simulation results supporting the proposed configuration are presented. <br /><br /> A third-harmonic current injection approach is utilized in this work in order to achieve <em>total harmonic distortion</em> (<em>THD</em>) mitigation from 32% to 5. 125% (theoretically). Two third-harmonic current injection networks have been investigated; one utilizes a real resistor, the other utilizes a resistor emulator to reduce the energy dissipated. The proposed controller for the resistor emulator does not require a proportional-integral (PI) controller. <br /><br /> As a result of the common devices between the voltage sag ride-through circuitry and the harmonic mitigation one, they can be integrated together in one circuitry connected in series with the DC-link of the ASD. And hence, the dual functionality of the hardware will be achieved. Simulation results supporting the theoretical results have been presented.
185

Torsional Torques and Fatigue Life Expenditure for Large-Scale Steam Turbine-Generator Shafts and Blades Due to Power System Harmonics

Tsai, Jong-ian 04 February 2004 (has links)
During the three decades, the torsional impact on turbine-generator sets due to power system disturbances has been extensively discussed in many research works. However, most of them are focused on the fatigue damage of turbine shafts due to large-signal disturbances. For example, network faults occur. Obviously, the torsional effect subject to small-signal disturbances has not received much attention. In fact, although the small disturbances would not immediately damage the turbine mechanism, the cumulative long-term damaging effects may not be negligible under certain circumstances. Many operating conditions in power systems may lead to small disturbances on blades; for examples, shedding loads, switching transmission line, resetting control system parameters, and harmonics etc. Nevertheless, others only cause short-term or transient non-resonant disturbances occasionally except the power system subharmonics which could results in electro-mechanical resonance. Therefore, two types of subharmonics in power systems are proposed so as to investigate the toque impact and long-term fatigue life expenditure in turbine shafts and blades. Firstly, from the steady-state disturbance viewpoint, the long-term cumulative fatigue estimation based on the three-year project of the GE Co. shows that there are potential damages for both the shafts and the blades of the nearby generators caused by the subharmonic excitations of the HVDC link. The fatigue life sensitivity works are also carried out to provide the recommendations for the safety operation. The optimal damper type and disposition scheme for depressing the resonant torque and prolonging the turbine lifetime is consequently motivated, which is based on participation factor of linear systems with the electromechanical analogy. The effectiveness of this scheme on suppressing vibration torque arising from network faults is also satisfying. In addition, the authors propose the new electromechanical supersynchronous resonance phenomenon for the turbine-generators near the inverter station owing to asymmetric line faults near the rectifier station. Secondly, the dramatic real and reactive power consumption during the melting period of an electrical arc furnace load. The voltage flicker pollution is mainly caused by the reactive power fluctuation while the stochastic subsynchronous oscillation in turbine mechanism is excited by the electromagnetic torque of the subsynchronous frequency which is induced by the real power fluctuation. Such a small stress imposed on the low-pressure long turbine blade combined with its evitable corrosive environment contributing to the corrosion fatigue effect. Although the voltage flicker severity at the point of common coupling is still within the limit, the blade may have been damaged from the long-term corrosion fatigue life expenditure estimation. In other words, the conventional voltage flicker limit established to make human-eye comfortable might not protect the blade from damaging risk. The long-term influence resulted from the electric arc furnace loads cannot always be neglected. It is necessary to take care of the blade material intensity and operating environment. If there is the potential of blade damage, one has to strengthen the output capacity at the power plant or separate the peak load durations among the steel plants to limit the over-fluctuation real power of the generator.
186

Application of Wavelet-probabilistic Network to Power Quality and Characteristic Harmonics Detection

Tsao, Ming-Chieh 20 July 2004 (has links)
Power quality has attracted considerable attentions from utilities and customers due to the popular uses of the sensitive electronic equipment. Harmonics, voltage swell, voltage sag, and power interruption could downgrade the service quality. Harmonic currents injected by non-linear loads throughout the network could degrade the quality of services to sensitive high-tech customers such as the science park of Xin-Zhu and Tai-Nan in Taiwan. In recent years, massive rapid transit system (MRT) and high speed railway (HSR) have been rapidly developed, with the applications of wide-spread semi-conductor technologies in the auto-traction system. Swell and sag could occur from thundering, capacitor switching, motor starting, nearby circuit faults, or artificial calamity, and could also attribute to the power interruption. To ensure the power quality, harmonic and voltage disturbances detection becomes important. Fourier transformation is used to analyze distorted waves in the frequency domain, with low-pass filter used to eliminate the fundamental component, and then characteristic harmonics can be detected. The complicated process is difficult to operate in real-time. The method-based processing model with physical harmonic data is needed to simplify the processing architecture. The thesis proposes to use wavelet transformation (WT) and probabilistic neural network (PNN) for power quality and characteristic harmonics detection. Wavelet-probabilistic network (WPN) is first used to extract distorted waves. PNN based processing model will then analyze the harmonic components. Computer simulation shows a simplified model to shorten the processing time in this study.
187

Prediction Of Hot-spot And Top-oil Temperatures Of Power Transformers According To Ieee Standards C57.110-1998 And C57.91-1995

Karaca, Haldun 01 December 2007 (has links) (PDF)
In this thesis, the effects of Harmonics on the Top Oil and Hot Spot Temperatures of Power Transformers used in Turkish Electricity Transmission System have been investigated. Due to the solid state equipment, the harmonic levels increase. This effect raises the losses and temperatures in the transformer windings. None of the power transformers currently used in Turkey has measuring equipment suitable for measuring the Hot-Spot temperatures. In this study, a computer program is written in LABVIEW which measures the harmonics and calculates the temperatures in accordance with the methods recommended in IEEE Standards C57.110-1998 and C57.91-1995. Also for sample transformers the work has been verified by measuring the Top-Oil temperatures of the transformers and then comparing with the calculated results.
188

A Non-invasive Speed And Position Sensor For Induction Machines Using External Search Coils

Keysan, Ozan 01 January 2009 (has links) (PDF)
In industrial drives market, speed and position estimation are one of the most important subjects for accurate motor drives. Vector controlled drives has the best dynamic performance among AC motor drives. Sensorless vector control is one of the most studied one. However, sensorless drive systems fail at low or zero speeds and may not have enough accuracy. For better accuracy and speed range speed sensors or position encoders are usually essential. However, coupling of sensor and sensor prices introduces extra cost on the drive. Thus in order to reduce the cost of the drive a cheap and easy to mount speed sensor is essential. Throughout this study, a speed and position sensor using an external search coil placed between cooling fins on the frame of an induction machine is proposed. The search coil utilizes the fringing flux outside the frame of induction motor. Using the induced voltage on the external search coil, a new method that estimates the flux and rotor position is proposed. In this study, the induced voltage on the search coils are investigated with different types of search coils placed on various positions. The frequency domain and time domain analysis are performed in order to build a model that can estimate machine flux, rotor speed and rotor position. As a result of this study, a low cost, easy to mount speed and position sensor is designed and implemented. Experiment results are presented.
189

Development Of A Matlab Based Software Package For Ionosphere Modeling

Nohutcu, Metin 01 September 2009 (has links) (PDF)
Modeling of the ionosphere has been a highly interesting subject within the scientific community due to its effects on the propagation of electromagnetic waves. The development of the Global Positioning System (GPS) and creation of extensive ground-based GPS networks started a new period in observation of the ionosphere, which resulted in several studies on GPS-based modeling of the ionosphere. However, software studies on the subject that are open to the scientific community have not progressed in a similar manner and the options for the research community to reach ionospheric modeling results are still limited. Being aware of this need, a new MATLAB&reg / based ionosphere modeling software, i.e. TECmapper is developed within the study. The software uses three different algorithms for the modeling of the Vertical Total Electron Content (VTEC) of the ionosphere, namely, 2D B-spline, 3D B-spline and spherical harmonic models. The study includes modifications for the original forms of the B-spline and the spherical harmonic approaches. In order to decrease the effect of outliers in the data a robust regression algorithm is utilized as an alternative to the least squares estimation. Besides, two regularization methods are employed to stabilize the ill-conditioned problems in parameter estimation stage. The software and models are tested on a real data set from ground-based GPS receivers over Turkey. Results indicate that the B-spline models are more successful for the local or regional modeling of the VTEC. However, spherical harmonics should be preferred for global applications since the B-spline approach is based on Euclidean theory.
190

Power System Harmonic Sources and Location Detection with Artificial Intelligence

Tu, Keng-Pang 12 June 2003 (has links)
The technology of power electronics is used increasingly during recent years, and the electronic power facilities are used more and more in the power system. The non-linear electronic loads produce heavy harmonic currents and could significantly degrade the power quality. Nonlinear loads, including the un-interruptible power supply, motor control and converter, etc, are important equipment in a modern factory, however, these nonlinear loads could lead to power facility malfunction and capacitor damage. The harmonics would eventually cause severe unexpected capital loss. Identification of harmonic sources location becomes an important study for power quality. An effective tool is thus helpful for the harmonic source locating. This paper proposes a method to deal with the harmonic sources and location detection in the power system by using the artificial neural network (ANN). The non-linear loading characteristics are studied by the power flow analysis, and then the proposed methodology uses the Probabilistic Neural Networks¡]PNN¡^and wavelet-probabilistic network (WPN) for harmonic source locating. An IEEE 14-bus power system is used for study to show the effectiveness of the proposed approach.

Page generated in 0.0266 seconds