• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 7
  • Tagged with
  • 18
  • 18
  • 18
  • 18
  • 12
  • 11
  • 11
  • 11
  • 11
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modulation of the HPA axis alters the sensitivity of the cochlea to acoustic trauma /

Tahera, Yeasmin, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2006. / Härtill 4 uppsatser.
2

The functional role of the lateral olivocochlear system and mechanisms underlying sound conditioning /

Niu, Xianzhi, January 2004 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2004. / Härtill 5 uppsatser.
3

Thai tonal perception in hearing-imporied patients /

Chuleeporn Nimitbunnasarn, Poonpit Amatyakul, January 1984 (has links) (PDF)
Thesis (M.A. (Communication Disorders))--Mahidol University, 1984.
4

Hearing protection a means to health promotion : a research project to satisfy ... Master of Science (Community Health Nursing/Occupational Nursing) /

Rowley, Suzanne A. January 1991 (has links)
Thesis (M.S.)--University of Michigan, 1991.
5

Hearing protection a means to health promotion : a research project to satisfy ... Master of Science (Community Health Nursing/Occupational Nursing) /

Rowley, Suzanne A. January 1991 (has links)
Thesis (M.S.)--University of Michigan, 1991.
6

Estudo comparativo de exames audiométricos de trabalhadores de cinco categorias profissionais / Audiogram comparison of workers from five professional categories

Duarte, Alexandre Scalli Mathias, 1982- 28 August 2018 (has links)
Orientador: Reinaldo Jordão Gusmão / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-28T02:13:31Z (GMT). No. of bitstreams: 1 Duarte_AlexandreScalliMathias_M.pdf: 1456659 bytes, checksum: 02d867305f679922c5ce3ca16dccc79a (MD5) Previous issue date: 2015 / Resumo: Introdução: O ruído é considerado a terceira maior causa de poluição ambiental e pode ser visto como um risco de agravo à saúde. A Organização Mundial da Saúde estima que 10% da população mundial está exposta a níveis elevados de pressão sonora potencialmente lesivos. Torna-se mais problemático quando se trata de ruído no ambiente de trabalho. A exposição ao ruído, ocupacional ou não, pode acarretar alterações auditivas (hipoacusia, zumbido, dificuldade de compreensão da fala e hiperacusia) e não auditivas (irritação, distúrbios do sono, doenças cardiovasculares, dentre outros). Quando é intenso e a exposição a ele é continuada, podem surgir alterações estruturais na orelha interna, que determinam a ocorrência da Perda Auditiva Induzida por Ruído. O mecanismo de lesão do órgão espiral ocorre na espira basal da cóclea, área responsável pelo som de frequências altas. Objetivos: Avaliar as médias aritméticas dos limiares auditivos tonais das frequências 3, 4 e 6 kHz de trabalhadores de setores industriais diversos e relacioná-las com o tempo de exposição ao ruído e diferentes tipos de trabalho. Metodologia: Foram calculadas as médias aritméticas das frequências audiométricas de 3, 4 e 6 kHz para cada orelha de 2.140 exames audiométricos e verificado suas relações com o tempo de exposição ao ruído, idade e categorias de trabalho. Conclusões: Houve piora significativa das médias aritméticas em 3, 4 e 6 kHz nos quatro grupos, por tempo de exposição, em todas as categorias profissionais analisadas. As médias aritméticas, dos limiares tonais das frequências 3, 4 e 6 kHz, em decibéis, podem ser consideradas úteis para análise de lesões cocleares relacionadas com a exposição contínua a ruído. Na comparação entre as diferentes categorias profissionais, foram observadas diferenças significativas das médias aritméticas em 3, 4 e 6 kHz apenas entre transportadores de cargas e os trabalhadores das demais categorias. A orelha esquerda apresentou limiares audiométricos piores do que a direita, em todas as avaliações, independentemente da categoria profissional / Abstract: Introduction: Noise is considered the third largest cause of environmental pollution and can be seen as a risk to health conditions. The World Health Organization (WHO) estimates that 10% of the world population is exposed to high levels of potentially harmful sound pressure. It becomes more problematic when it comes to noise in the working environment. Exposure to noise, occupational or not, can cause hearing disorders (hearing loss, tinnitus, difficulty in speech understanding and hyperacusis) and not hearing disorders (irritation, sleep disorders, cardiovascular diseases and others). When intense and exposure to it is continued, there may be structural changes in the inner ear, which determine the occurrence of Noise-Induced Hearing Loss. The spiral organ injury mechanism occurs in the basal turn of the cochlea, area responsible for the sound of high frequencies. Objectives: To assess the arithmetic average of audiometric pure tone thresholds in frequencies 3, 4 and 6 kHz of various industrial sectors workers and relating them to the time of exposure to noise and different types of work. Methods: We calculated the arithmetic means of audiometric frequencies of 3, 4 and 6 kHz for each ear of 2.140 audiometry and verified its relations with the noise exposure time, age and job categories. Conclusions: There was a significant worsening of the arithmetic averages in 3, 4 and 6 kHz in the four groups, exposure time, in all occupational categories analyzed. The averages, of pure tone thresholds of frequencies 3, 4 and 6 kHz, in decibels, can be considered useful for analysis of cochlear injury related to continuous exposure to noise. Comparing the different professional categories, significant differences of arithmetic means were observed in 3, 4 and 6 kHz only between carriers of cargo and workers in other categories. The left ear had audiometric thresholds worse than the right, in all evaluations regardless of profession / Mestrado / Otorrinolaringologia / Mestre em Ciências Médicas
7

Stereocilia of sensory cells in normal and hearing impaired ears a morphological, physiological and behavioural study /

Engström, Berit. January 1983 (has links)
Thesis (Doctoral)--Uppsala University, 1983. / Includes bibliographical references (p. 33-34).
8

Análise dos níveis de ruído produzidos pelas canetas de alta rotação nas freqüências de bandas de oitavas e as atenuações dos protetores auriculares /

Ferreira, Nelly Foster. January 2005 (has links)
Orientador: Artênio José Isper Garbin / Banca: Renato Moreira Arcieri / Banca: Edgard Michel Crosato / Resumo: O aumento das fontes produtoras de ruído tem prejudicado a qualidade de vida dos profissionais, acelerando a deterioração do aparelho auditivo, podendo causar lesões irreversíveis, dependendo da intensidade do ruído e do tempo de exposição. O objetivo do presente estudo foi analisar o nível de ruído de 3 marcas diferentes de instrumentos de alta rotação, e identificar qual será o menos lesivo ao profissional e, ainda, verificar as atenuações produzidas por protetores auriculares tipo plug de 4 diferentes marcas e indicar o de maior eficiência na prática profissional. O instrumento utilizado foi um medidor de nível sonoro, decibelímetro com filtro de banda de oitava e terça oitava. Foram feitas no total de 740 medições, sendo que os resultados dessas medições foram analisados juntamente com as atenuações em decibels nas freqüências de bandas de 1/1 oitavas das 4 marcas diferentes de protetores auriculares do tipo plug, disponíveis, atualmente, no mercado. Os resultados da aferição de ruído em média de 72,1dB para Caneta B; 79,8 dB para Caneta C e 80,8 dB Caneta A, não ultrapassam o limite de 85 dB, conforme a NR-15 da norma de Segurança e Medicina do Trabalho e, portanto, não sendo obrigatório o uso do protetor auditivo. No entanto todos os valores ficaram acima de 65 dB da norma NBR-10152 de conforto acústico. Em relação ao protetor auricular, pode-se observar que, a maior média apresentada foi da marca Pomp Plus (26,7 dB), seguido da Dura Plus Plug (25,6 dB), CO-MAXXI (24,8 dB) e 3M1270 (24,8 dB), no entanto, convém salientar que houve altos valores do desvio padrão nas atenuações em todas as freqüências. Conclui-se que o profissional deve adotar medias de comportamento preventivo, como o uso do protetor auricular, mesmo que não obrigatório, para evitar lesões auditivas ao longo de sua carreira. / Abstract: The increase of the producing sources of noise has been harmful to the quality of professionals' life, speeding up the deterioration of the auditory device, it could be causing irreversible injuries, depending on the intensity of the noise and the exposition time. The objective of the present study was analyze the level of noise of 3 different marks of high speed handpieces, and to verify the attenuations produced for auditive protectors type plug of 4 different marks and to indicate the more efficiency in the practical professional. The instrument used was a sound level meter, with band of eighth filter. It had been made in the total of 740 measurements, being that the results of these measurements had been analyzed together with the attenuations in decibels in each frequency of the 4 different marks of auditive protectors, available, currently, in the market. The results of the measurements of noise in average of 72.1dB for high speed handpiece B, 79.8 dB for high speed handpiece C and 80.8 dB high speed handpiece A, and these values does not above 85 dB in accordance to NR-15 of the Security and Work Medicine Norms and does not obligate the use of auditive protector. However all the values had been above of 65 dB of the NBR-10152 norm of acoustic comfort. In relation to the auditive protector, it can be observed that, the presented average greater was of the mark Pomp Plus (26.7 dB), followed of Dura Plus Plug (25.6 dB), CO-MAXXI (24.8 dB) and 3M1270 (24.8 dB), however the standard deviation of the attenuations in all the frequencies is high values. It is concluded that the professional must adopt measured of preventive behavior, as the use of the auditive protector, exactly that not obligator, to prevent them about auditory injuries in all career. / Mestre
9

Implantação de um programa de conservação auditiva: enfoque fonoaudiológico / Implementation of Hearing Conservation Program: focus audiologyst.

Rios, Ana Lúcia 31 May 2007 (has links)
RIOS, A. L. Implantação de um Programa de Conservação Auditiva: enfoque fonoaudiológico. 2007. 133f. Tese (Doutorado) Faculdade de Medicina de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, 2007. A tecnologia e a modernidade proporcionam, em alguns casos, a ocorrência de doenças ocupacionais e consequentemente a queda na qualidade de vida da classe trabalhadora causada, muitas vezes, pelo aumento dos níveis de ruído nas indústrias. Com isso a Perda Auditiva Induzida por Ruído (PAIR) tem ocupado lugar de destaque entre as doenças ocupacionais. A implantação de um Programa de Conservação Auditiva (PCA) é necessária em locais de trabalho onde os níveis de exposição ao ruído estejam acima dos limites de tolerância. O objetivo do estudo foi propor para a direção de uma empresa a implantação de um Programa de Conservação Auditiva na Divisão de Nutrição e Dietética (DND), área que apresenta nível de pressão sonora elevado, verificando a eficácia do trabalho dos profissionais atualmente envolvidos e enfocando o papel do fonoaudiólogo. Foram analisadas as avaliações auditivas contidas nos prontuários médicos de todos os funcionários da DND realizadas durante o período de dezembro de 2004 (ano base) a março de 2006. Por meio de um questionário, os dados pessoais e referentes à história clínica e ocupacional dos trabalhadores foram colhidos. Paralelamente aos procedimentos já citados, foram realizadas palestras e/ou mini-cursos aos funcionários da Divisão sobre os cuidados com a audição, a necessidade e importância do uso do equipamento de proteção individual, a importância da realização dos exames auditivos, além de esclarecimentos relativos às portarias e normas de saúde ocupacional. Participaram do estudo 174 funcionários da DND com idade variando de 23 a 61 anos (média de 43 anos) e predomínio do gênero feminino (93,68%). No ambiente de produção da DND o ruído variou entre menos de 60dB(A) a 88,7dB(A) e as áreas mais ruidosas respectivamente são: Seção de Preparo e Cocção, Seção de Cozinha e Dietética, Lavagem e Esterilização e Restaurante I. A maioria dos funcionários faz uso do protetor auricular com freqüência e participam das capacitações que a empresa proporciona, porém em 2004, 35,29% apresentaram algum tipo da alteração na acuidade auditiva, sendo que, na sua maioria, a configuração audiométrica é sugestiva de PAIR e quando os exames de 2004 foram comparados com os de 2005, o agravamento da perda auditiva foi de 32%, demonstrando que as medidas de prevenção adotadas estão pouco eficazes. Com esses dados concluímos que a implantação de um programa de conservação auditiva com ações sincronizadas entre os que realizam as atividades preventivas, na empresa se faz urgente. / RIOS, A. L. Implementation of Hearing Conservation Program: focus audiologyst. 2007. 133f. Tese (Doutorado) University of Medicine at Ribeirão Preto, University of São Paulo, Ribeirão Preto, 2007. The technology and the modernity provide, in some cases, the occurrence of occupational diseases and consequently, a decrease in the health quality of live of the workers, due to increase in the level of noise in the industries. Hence, the Noise-Induced Hearing Loss (NIHL) plays a critical role among the occupational diseases. The implementation of a Hearing Conservation Program (HCP) is necessary in work places where the levels of noise are above the tolerance limits. The aim of this study was to propose, to the manage department of an enterprise, a Hearing Conservation Program to be applied in the Department of Nutrition and Dietary (DND). This department presents high levels of sound pressure and the HCP implementation had the objective of reaching the work efficiency of the workers involved in this section, focusing on the role of the audiologyst. The hearing tests described on the medical records of all workers of the DND, during the period of 2004 (year-base), december to 2006, march, were analyzed. Personal data related to the clinical and occupational history of the workers were collected using a questionary. Simultaneously to the procedures already mentioned, talks and small courses were implemented involving the workers, about hearing cares and medical examinations, the individual protection equipment importance and health laws and normatization. One hundred seventy four (174) DND workers answered the quiz, with ages varying between 23 and 61 years old (an average of 43 years old) and almost all women (93,68%). In the DND installations, the noise varied between less than 60dB(A) and 88,7dB(A) and the noisiest areas are, respectively: preparing and cooking, kitchen and dietary, washing and sterilization and restaurant I. Usually, all workers use an protector headphone and also attend the technical courses provided by the enterprise. However, in 2004, 32,29% presented some kind of hearing alteration and, mostly, the audiologic configuration is suggestive of NIHL. Besides, when the exams of the year of 2004 were compared to the exams of 2005, it was possible to note an increase of 32% in the hearing losses of the workers, showing that the adopted prevention actions are not efficient. Using these data, one can conclude that to implement a hearing conservation program and synchronized actions among the ones who develop prevention activities is urgent.
10

Hearing impairment and deafness : genetic and environmental factors - interactions - consequences : a clinical audiological approach /

Carlsson, Per-Inge, January 2005 (has links)
Diss. (sammanfattning) Örebro : Örebro universitet, 2005. / Härtill 5 uppsatser.

Page generated in 0.1084 seconds