• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Exposição dérmica de trabalhadores a resíduos de deltametrina presentes nas plantas, na reentrada na lavoura de algodão após pulverização /

Rotundo, Maurício. January 2007 (has links)
Orientador: Geraldo Papa / Banca: Sérgio Luis de Carvalho / Banca: Luiz Roberto Pimentel Trevizan / Resumo: A exposição dérmica de amostradores foi avaliada na reentrada em lavoura de algodão após pulverização com o inseticida deltametrina. Aos 3 minutos após a aplicação quatro pessoas vestiram um conjunto de roupas (calça, camisa e luvas), entrando e permanecendo na área tratada por 30 minutos, simulando uma amostragem de pragas. O procedimento foi repetido aos 60 e 300 minutos e aos 1, 3, e 7 dias após a aplicação. Partes do tecido, correspondentes ao local de contato com várias partes do corpo, foram recortadas e analisadas quanto à quantidade de resíduos presentes. O inseticida foi extraído das roupas com acetato de etila e a determinação quantitativa foi feita por cromatografia gasosa. As exposições foram extrapoladas para uma jornada de trabalho de oito horas. Para classificar a segurança das condições de trabalho foram estimadas a margem de segurança (MS), dose tóxica (%DT/dia), dose tolerável dérmica e o tempo de trabalho seguro. O conjunto correspondente aos antebraços/braços/mãos concentrou 61,27% dos resíduos presentes na roupa. Partes correspondentes ao peitoral, pernas, coxas e costas alcançaram 13,40; 9,33; 9,32; e 6,65% dos resíduos totais encontrados nas roupas, respectivamente. Pela análise dos dados constatou-se que o intervalo de reentrada estabelecido para o produto comercial Decis 25 CE (deltametrina) que é de 24 h está superestimado. / Abstract: The objective of this work was to study the dermal exposure of workers to residues of the deltamethrin, applied in cotton. After 3 minutes of application four people dressed a group with cotton clothes (pant, shirt and gloves), entered and stayed in the treated area by 30 minutes, simulating a sampling. The procedure was repeated after 60 and 300 minutes and 1, 3, and 7 days of the application. The clothes were cut and put in plastic bags, and stored cold at -18º until analyses was performed. The analytical method consisted on the extraction of deltamethrin residues with a ethyl acetate and the quantitative determination was done by gas chromatograph. Exposure was extrapolated to a work day of 8 hours. To evaluate safety's conditions at work was estimated the Working Condition Unsafe (margin of safety - MOS <1), Poisonous Dose (%PD/day), Dermal Dose Tolerable and the estimate of Safe Work Duration (SWD). The corresponding group for the forearms/arms/hands concentrated 61.27% of present residues in the clothes. The residues found on the clothes, chest, legs, lame and back, were 13.40, 9.33, 9.32, and 6.65%, respectively. Results of deltamethrins amounts trapped on cotton clothes showed that 24h as a reentry interval for Decis 25 EC is overestimated. / Mestre
2

Análise dos níveis de ruído produzidos pelas canetas de alta rotação nas freqüências de bandas de oitavas e as atenuações dos protetores auriculares /

Ferreira, Nelly Foster. January 2005 (has links)
Orientador: Artênio José Isper Garbin / Banca: Renato Moreira Arcieri / Banca: Edgard Michel Crosato / Resumo: O aumento das fontes produtoras de ruído tem prejudicado a qualidade de vida dos profissionais, acelerando a deterioração do aparelho auditivo, podendo causar lesões irreversíveis, dependendo da intensidade do ruído e do tempo de exposição. O objetivo do presente estudo foi analisar o nível de ruído de 3 marcas diferentes de instrumentos de alta rotação, e identificar qual será o menos lesivo ao profissional e, ainda, verificar as atenuações produzidas por protetores auriculares tipo plug de 4 diferentes marcas e indicar o de maior eficiência na prática profissional. O instrumento utilizado foi um medidor de nível sonoro, decibelímetro com filtro de banda de oitava e terça oitava. Foram feitas no total de 740 medições, sendo que os resultados dessas medições foram analisados juntamente com as atenuações em decibels nas freqüências de bandas de 1/1 oitavas das 4 marcas diferentes de protetores auriculares do tipo plug, disponíveis, atualmente, no mercado. Os resultados da aferição de ruído em média de 72,1dB para Caneta B; 79,8 dB para Caneta C e 80,8 dB Caneta A, não ultrapassam o limite de 85 dB, conforme a NR-15 da norma de Segurança e Medicina do Trabalho e, portanto, não sendo obrigatório o uso do protetor auditivo. No entanto todos os valores ficaram acima de 65 dB da norma NBR-10152 de conforto acústico. Em relação ao protetor auricular, pode-se observar que, a maior média apresentada foi da marca Pomp Plus (26,7 dB), seguido da Dura Plus Plug (25,6 dB), CO-MAXXI (24,8 dB) e 3M1270 (24,8 dB), no entanto, convém salientar que houve altos valores do desvio padrão nas atenuações em todas as freqüências. Conclui-se que o profissional deve adotar medias de comportamento preventivo, como o uso do protetor auricular, mesmo que não obrigatório, para evitar lesões auditivas ao longo de sua carreira. / Abstract: The increase of the producing sources of noise has been harmful to the quality of professionals' life, speeding up the deterioration of the auditory device, it could be causing irreversible injuries, depending on the intensity of the noise and the exposition time. The objective of the present study was analyze the level of noise of 3 different marks of high speed handpieces, and to verify the attenuations produced for auditive protectors type plug of 4 different marks and to indicate the more efficiency in the practical professional. The instrument used was a sound level meter, with band of eighth filter. It had been made in the total of 740 measurements, being that the results of these measurements had been analyzed together with the attenuations in decibels in each frequency of the 4 different marks of auditive protectors, available, currently, in the market. The results of the measurements of noise in average of 72.1dB for high speed handpiece B, 79.8 dB for high speed handpiece C and 80.8 dB high speed handpiece A, and these values does not above 85 dB in accordance to NR-15 of the Security and Work Medicine Norms and does not obligate the use of auditive protector. However all the values had been above of 65 dB of the NBR-10152 norm of acoustic comfort. In relation to the auditive protector, it can be observed that, the presented average greater was of the mark Pomp Plus (26.7 dB), followed of Dura Plus Plug (25.6 dB), CO-MAXXI (24.8 dB) and 3M1270 (24.8 dB), however the standard deviation of the attenuations in all the frequencies is high values. It is concluded that the professional must adopt measured of preventive behavior, as the use of the auditive protector, exactly that not obligator, to prevent them about auditory injuries in all career. / Mestre
3

Percepção do cirurgião-dentista da rede pública de saúde sobre as condições de trabalho /

Silva, Milene Moreira. January 2011 (has links)
Orientador: Suzely Adas Saliba Moimaz / Banca: Roosevelt da Silva Bastos / Banca: Ana Paula Dossi de Guimarães e Queiroz / Resumo: A qualidade dos serviços prestados na área da saúde está relacionada à ambientes de trabalho saudáveis, infra-estrutura adequada, disponibilidade de equipamentos e materiais em boas condições de uso, bem como ao preparo e satisfação dos profissionais com o emprego e toda a equipe de trabalhadores. Ambientes de trabalho insalubres geram riscos iminentes de contaminação, tanto do profissional quanto do paciente, e a falta de infra-estrutura e manutenção de equipamentos, podem prejudicar ou impossibilitar o atendimento ao usuário do Sistema Único de Saúde (SUS). O objetivo da pesquisa foi analisar a percepção do cirurgião-dentista da rede pública de saúde sobre as condições físicas e sanitárias de trabalho, os aspectos trabalhistas e a satisfação com a profissão e com o emprego público. Trata-se de um estudo tipo inquérito, transversal, no qual 40 cirurgiões-dentistas foram entrevistados. Quanto ao ambiente de trabalho, 49% dos profissionais o consideraram desconfortável, 45% demonstraram insatisfação com a refrigeração local, 45% com os ruídos, 20% com a limpeza e 37,5% com as dimensões. Já em relação ao tempo de uso dos equipamentos odontológicos, muitos tinham mais de 24 anos de uso, sendo que 32,5% dos profissionais referiram-se ao equipo, 30% à cuspideira e 32,5% à cadeira odontológica. Dentre os entrevistados, 92,6% já deixaram de atender pacientes por quebra dos equipamentos e 90% do total citaram que os mesmos receberam manutenção de reparo, não havendo, portanto, a manutenção periódica dos mesmos. Quanto às condições de uso dos equipamentos, 40% dos cirurgiões-dentistas informaram que o equipo encontrava-se em condição ruim ou péssima, 17,5% referiram-se ao mocho e 37,5% à cadeira odontológica. Em 55% dos locais de trabalho a esterilização de instrumentais era feita em estufa, 35% dos ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The quality of health services is related to healthy work environments, ideal infra-structure, good equipments and consumption materials, knowledge and satisfaction of professionals with job and workers team. Work environments that not allow health conditions for dentists to fulfill Dentistry, cause contamination risks for professional and patients. The absence of infra-structure and equipments' maintenance can damage or block the attendance of Brazilian Health System (SUS) users. The aim of this research was evaluate the perception of dentists that works in public health system about physical and health work conditions, job aspects and their satisfaction in relation to profession and public job. It's an investigation and transversal study where 40 dentists were interviewed. About wok environment, 49% of interviewed professionals considered it like uncomfortable, 45% demonstrated dissatisfaction with space cooling, 45% with noises, 20% with cleaning and 37,5% with size of dental office. In relation to time of use of dental equipments, many of them were over than 24 years and 32,5% of professionals referred to dental unit, 30% to spittoon and 32,5% to dental chair. Among all participants, 92,6% couldn't give attendance for patient due broken equipments, and 90% of total, cited that the equipments received maintenance type repair, because the maintenance service is not periodically and occurred only when the attendance for patient was blocked. About use condition of equipments, 40% of dentists informed that dental unit were in bad or terrible conditions, 17,5% referred to stool and 37,5% dental chair. In 55% of work locals the sterilization of instruments was performed using oven, 35% of professionals worked without dental auxiliaries and 22,5% demonstrated dissatisfaction in relation to local biossecurity. The majority of interviewed professionals (95%) was ... (Complete abstract click electronic access below) / Mestre

Page generated in 0.4719 seconds