Fällning av kisel från avloppsvatten vid Hellisheidarvirkjun - experimentell studie / Experiments with precipitation of silica from waste water at HellisheiðarvirkjunÓLAFSDÓTTIR, VERA SÓLVEIG January 2015 (has links)
This report is about the experiments with mixing of the separated water and the vacuum pump seal water at Hellisheiði power plant. This is done to prevent silica scaling and clogging in pipes and reinjection wells as well as eliminating vacuum pump seal water from the plant. The experiments were done in four stages: the first stage comprised of tests with different flows of separated water at 70°C, the second stage was carried out by mixing the separated water at 70°C and the seal water with different amounts of the seal water, the third and the fourth stages were like the first and second but with the separated water at 120°C. The results show that this method is good if the mixture is around 50/50 separated water and seal water, to control the silica scaling in the separated water and to be able to reinject the seal water with the separated water. This does not eliminate the silica scaling in all of the separated water because the amount of separated water is much more than the amount of seal water that comes from the plant.
|
2 |
Flow Paths in the Húsmúli Reinjection Zone, Iceland / Flödesvägar i Húsmúli-återinjektionszonen, IslandTómasdóttir, Sigrún January 2018 (has links)
Reinjection of spent geothermal fluids has become common practise in geothermal power plants. Reinjection can, despite being mostly beneficial, have unwanted effects such as cooling of nearby production wells and injection-induced earthquakes. Tracer tests, along with their modeling and interpretation, are important tools for monitoring the flow paths of the injected water and to predict reservoir cooling. Knowledge of flow paths in the system allows for better resource management and a more sustainable utilization. A simulation model of the Húsmúli reinjection zone in the Hellisheiði Geothermal Power Plant in SW-Iceland was developed using the TOUGH2 program. Its hydrological parameters, porosity and permeability, were calibrated using results from an extensive tracer test carried out in the area in 2013-2015. The aim of the simulations was to obtain better understanding of the flow paths in Húsmúli since, despite fast tracer recovery in production wells in the area, hardly any cooling has been observed in those production wells. The results show that the tracer recovery can be modelled by means of permeable flow channels within the medium. Good results for tracer arrival and concentration peaks were obtained both by assuming a single wide channel and several narrower ones. The parameters that gave the best fit for the single channel model were permeability of 5·10-12 m2 and porosity ranging from 0.2%–3%. For the multi-channel model they were 1·10-12 m2 and 0.2%–3.5%, respectively. The high permeability and low porosity in the channels make for an abstract representation of fractured zones within the medium. Greater cooling was seen with the single-channel modelling approach than with the multiple narrower channel approach, the latter showing hardly any cooling in the production elements during the simulation time. This indicates that the flow paths are more likely multiple channels consisting of fracture networks. The simulations show that the flow paths are lengthened by sinking of the fluid to greater depth because of the higher density of the colder injected water. This implies that the injected fluid is warmed up by contact with a larger volume of rock, causing a limited and delayed cooling effect. / Geotermisk energi anses vara en förnybar och miljövänlig energikälla. Som sådan, kan den spela en viktig roll för att minska utsläppen av växthusgaser från energisektorn över hela världen och genom det bekämpa antropogena klimatförändringar. Geotermiska kraftverk extraherar het vätska från berggrunden, separerar ångan från vätskan och använder sedan ångan för att driva turbiner som genererar elektricitet. Injektion av använd geotermisk vätska från kraftverk har blivit vanligt i den geotermiska industrin för att kassera använd geotermisk vätska, upprätthålla systemtrycket och öka produktionseffektiviteten. Återinjektion av nedkyld vätska kan, trots att den är mestadels fördelaktig, ha oönskade effekter, såsom kylning av närliggande produktionsbrunnar och injektionsinducerad seismisk aktivitet. Spårprov, som möjliggör spårning av en kemikalie inom systemet, tillsammans med modellering, är viktiga verktyg för att förstå flödesvägarna för det injicerade vattnet samt att kunna förutsäga nedkylningar av vattenmagasin. Kunskap om flödesvägar i systemet möjliggör bättre resurshantering och ett mer hållbart användande. En simuleringsmodell av återinjektionszonen för det geotermiska kraftverket Hellisheiði på sydvästra Island, Húsmúli, utvecklades med hjälp av simuleringsprogrammet TOUGH2. Dess hydrologiska parametrar, permeabilitet och porositet, kalibrerades med hjälp av resultat från ett omfattande spårtest som utfördes i området 2013-2015. Syftet med simuleringarna var att få en bättre förståelse av flödesvägarna i Húsmúli. Detta er inressant eftersom trots en snabb återhämtning av spårämne i produktionsbrunnar, har knappt någon kylning observerats i området. Resultaten visar att återhämtningen av spårämnet inte kan modelleras med ett homogent medium, men kan istället modelleras genom att bygga permeabla strömningskanaler inom mediet. Goda resultat för spårämnesankomst och koncentrationstoppar erhölls både genom att använda en enda bred kanal och flera smalare. Kanalerna ger en abstrakt representation av sprickzoner inom mediet. Större kylning observerades för modelleringsmetoden med en enkel bred kanal än med flera smalare kanaler. Detta indikerar att flödesvägarna i området troligtvis går genom flera sprickzoner. Flödesvägarna förlängs genom att vätskan sjunker till ett större djup på grund av den högre densiteten hos det injicerade vattnet. Detta innebär att den injicerade vätskan värms upp genom kontakt med en större volym berg, vilket medför en begränsad och fördröjd kylningseffekt.
|
Page generated in 0.102 seconds