• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • Tagged with
  • 23
  • 7
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Anemometria térmica aplicada à hidrometria em regime de submedição.

CAVALCANTI, Tony Carlos Moura. 28 August 2018 (has links)
Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-08-28T20:29:05Z No. of bitstreams: 1 TONY CARLOS MOURA CAVALCANTI – TESE (PPGEEI) 2016.pdf: 4469755 bytes, checksum: 884382b3c566b4aca499dc522be900ab (MD5) / Made available in DSpace on 2018-08-28T20:29:05Z (GMT). No. of bitstreams: 1 TONY CARLOS MOURA CAVALCANTI – TESE (PPGEEI) 2016.pdf: 4469755 bytes, checksum: 884382b3c566b4aca499dc522be900ab (MD5) Previous issue date: 2016-12-12 / CNPq / O objetivo neste trabalho é propor um sistema para a hidrometria na faixa de submedição utilizando a anemometria térmica. O objetivo de medir vazão está presente em muitos campos da ciência, sendo necessário sabermos quais os valores de um material foram consumidos com o menor erro possível. Na primeira parte da pesquisa foram realizadas simulações em ambiente multifísico para identificar as condições de trabalho e possíveis pontos de localização do sensor. Para poder usar o sensor, é necessário conhecer valores limítrofes de trabalho do mesmo, ou seja, a faixa de operação, indicando assim a vazão mínima e máxima de operação do sensor anemométrico. Portanto, na segunda etapa do trabalho, foi proposta uma plataforma com um sistema de bombeamento para testar o sistema de medição proposto. A plataforma foi construída de modo a permitir que um fluído flua através de uma tubulação e, assim, determinar qual é a velocidade do fluído e, portanto, a vazão. / The objective of this work is to propose a system for the hydrometry in the sub-measurement range using thermal anemometry. The objective of measuring flow is present in many fields of science, it is necessary to know what values of a material were performed using COMSOL software to identify working conditions and maximum flow rate of the anemometric sensor. Therefore, in the second stage of the work, a platform with a pumping system was proposed in order to test the proposed measurement system. The platform was constructed so as to allow a fluid to flow through a pipeline, and thereby determine what the velocity of the fluid, and hence the flow, is.
22

Determinação de parâmetros do modelo pressão-vazamento para setor de distribuição de água da cidade de Piracicaba, SP / Determination of parameters of the pressure-leakage model for a water supply network of Piracicaba city, SP

Manzi, Daniel 30 April 2004 (has links)
A redução das perdas em sistemas de distribuição de água tem se tornado, além de uma questão ética, um determinante da eficiência e mesmo da sobrevivência das concessionárias destes serviços. A quantificação e determinação da natureza das vazões perdidas, que possuem relação íntima com as pressões de operação, são aspectos que ainda merecem análises mais profundas e práticas. Os parâmetros do modelo pressão-vazamento permitem o detalhamento das perdas físicas e foram obtidos por meio de calibrações para um setor de distribuição de água da cidade de Piracicaba, SP, em padrões hidráulicos distintos - sob hipótese de consumo noturno nulo (vazão mínima noturna), descargas de rede, patamares de pressão e sob consumo diurno dirigido pela pressão através de curvas encontradas na literatura e propostas. Os resultados obtidos indicaram que os valores dos parâmetros do modelo pressão-vazamento não são fixos, mas variam conforme o padrão hidráulico de operação da rede. Estudos acerca do parque de hidrômetros e seus desvios de indicação também foram realizados, em conjunto com uma análise das vazões típicas de abastecimento residencial, e apontaram para fortes erros de medição em razão do uso de reservatórios domiciliares. / Losses reduction on water supply networks came to be, beyond the ethical question, a condition for efficiency and even survival of enterprises which develop those services. Quantification and determination of the nature of leakage, which are closely related to operational pressure, are aspects which still claim for deeper and more practical analysis. Parameters to the pressure-leakage model allows to detail physical losses at one given system, and they were obtained throughout employment of distinct hydraulic patterns - minimal night flow (no usage), network flush situations, pressure levels and day usage driven by pressure from curves found on lectures and author\'s propositions - when proceeding calibration at a water supply section at the Piracicaba city, SP. Achieved results have shown that pressure-leakage model parameters values are not constant, but really change according to network\'s operational hydraulic pattern. Studies concerning section\'s water flow meters and its measuring deviation were also done, and joined to an analysis of typical patterns of home usage flows; they have pointed to huge metering errors because of employment of home reservoirs.
23

Determinação de parâmetros do modelo pressão-vazamento para setor de distribuição de água da cidade de Piracicaba, SP / Determination of parameters of the pressure-leakage model for a water supply network of Piracicaba city, SP

Daniel Manzi 30 April 2004 (has links)
A redução das perdas em sistemas de distribuição de água tem se tornado, além de uma questão ética, um determinante da eficiência e mesmo da sobrevivência das concessionárias destes serviços. A quantificação e determinação da natureza das vazões perdidas, que possuem relação íntima com as pressões de operação, são aspectos que ainda merecem análises mais profundas e práticas. Os parâmetros do modelo pressão-vazamento permitem o detalhamento das perdas físicas e foram obtidos por meio de calibrações para um setor de distribuição de água da cidade de Piracicaba, SP, em padrões hidráulicos distintos - sob hipótese de consumo noturno nulo (vazão mínima noturna), descargas de rede, patamares de pressão e sob consumo diurno dirigido pela pressão através de curvas encontradas na literatura e propostas. Os resultados obtidos indicaram que os valores dos parâmetros do modelo pressão-vazamento não são fixos, mas variam conforme o padrão hidráulico de operação da rede. Estudos acerca do parque de hidrômetros e seus desvios de indicação também foram realizados, em conjunto com uma análise das vazões típicas de abastecimento residencial, e apontaram para fortes erros de medição em razão do uso de reservatórios domiciliares. / Losses reduction on water supply networks came to be, beyond the ethical question, a condition for efficiency and even survival of enterprises which develop those services. Quantification and determination of the nature of leakage, which are closely related to operational pressure, are aspects which still claim for deeper and more practical analysis. Parameters to the pressure-leakage model allows to detail physical losses at one given system, and they were obtained throughout employment of distinct hydraulic patterns - minimal night flow (no usage), network flush situations, pressure levels and day usage driven by pressure from curves found on lectures and author\'s propositions - when proceeding calibration at a water supply section at the Piracicaba city, SP. Achieved results have shown that pressure-leakage model parameters values are not constant, but really change according to network\'s operational hydraulic pattern. Studies concerning section\'s water flow meters and its measuring deviation were also done, and joined to an analysis of typical patterns of home usage flows; they have pointed to huge metering errors because of employment of home reservoirs.

Page generated in 0.0328 seconds