• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Detection and Position Location of Partial Discharges in Transformers Using Fiber Optic Sensors

Song, Lijun 08 December 2004 (has links)
Power transformers are one of the most important components in the electrical energy network. Extending transformer life is very economically valuable due to power outage. Therefore the development of instruments to monitor the transformer condition is of great interest. Detection of partial discharges (PDs) in power transformers is an effective diagnostic because it may reveal and quantify an important aging factor and provide information on the condition of the transformer. However, partial discharge diagnostics are still not effectively used for online monitoring of transformers because of the complexity of PD measurements and difficulties of discriminating of PDs and other noise sources. This thesis presents a further study of detection and location of partial discharges in power transformers based on previous work conducted at the Center for Photonics Technology (CPT) at Virginia Tech. The detection and positioning system consists of multiple extrinsic Fabry-Parot interferometric (EFPI) fiber acoustic sensors which can survive the harsh environment of oil-filled transformers. This thesis work is focused on optimal arrangement of multiple sensors to monitor and locate PD activities in a power transformer. This includes the following aspects. First, the sensor design requirements are discussed in order to successfully detect and accurately position the PD sources. In the following sections, Finite Element Method (FEM) is used to model the EFPI sensor fabricated at CPT. Experiments were conducted to measure the angular dependence of the frequency response of the sensor. It is shown that within the range of ±45º incident angles, the sensitivity varies by 3-5dB. Finally, the thesis demonstrates a PD positioning experiment in a 500 gallon water tank (R à H = 74" à 30" cylinder) using a hyperbolic positioning algorithm and time difference of arrival (TDOA). Finally we demonstrated that 100% of the positioning data is bounded by a 22.7à 4.1à 5.3 mm₃ cube, with a sensing range of 810 mm using the leading edge method with FIR filtering. / Master of Science
2

Partial Discharge Detection and Localization in High Voltage Transformers Using an Optical Acoustic Sensor

Lazarevich, Alison Kay 27 May 2003 (has links)
A partial discharge (PD) is the dissipation of energy caused by the buildup of localized electric field intensity. In high voltage devices such as transformers, this buildup of charge and its release can be symptomatic of problems associated with aging, such as floating components and insulation breakdown. This is why PD detection is used in power systems to monitor the state of health of high voltage transformers. If such problems are not detected and repaired, the strength and frequency of PDs increases and eventually leads to the catastrophic failure of the transformer, which can cause external equipment damage, fires and loss of revenue due to an unscheduled outage. Reliable online PD detection is a critical need for power companies to improve personnel safety and decrease the potential for loss of service. The PD phenomenon is manifested in a variety of physically observable signals including electric and acoustic pulses and is currently detected using a host of exterior measurement techniques. These techniques include electrical lead tapping and piezoelectric transducer (PZT) based acoustic detection. Many modern systems use a combination of these techniques because electrical detection is an older and proven technology and acoustic detection allows for the source to be located when several sensors are mounted to the exterior of the tank. However, if an acoustic sensor could be placed inside the tank, not only would acoustic detection be easier due to the increased signal amplitude and elimination of multipath interference, but positioning could also be performed with more accuracy in a shorter time. This thesis presents a fiber optic acoustic sensing system design that can be used to detect and locate PD sources within a high voltage transformer. The system is based on an optical acoustic (OA) sensor that is capable of surviving the harsh environment of the transformer interior while not compromising the transformer's functionality, which allows for online detection and positioning. This thesis presents the theoretical functionality and experimental validation of a band-limited OA sensor with a usable range of 100-300 kHz, which is consistent with the frequency content of an acoustic pulse caused by a PD event. It also presents a positioning system using the time difference of arrival (TDOA) of the acoustic pulse with respect to four sensors that is capable of reporting the three-dimensional position of a PD to within ±5cm on any axis. / Master of Science

Page generated in 0.0897 seconds