Detection and Position Location of Partial Discharges in Transformers Using Fiber Optic Sensors

Song, Lijun 08 December 2004 (has links)
Power transformers are one of the most important components in the electrical energy network. Extending transformer life is very economically valuable due to power outage. Therefore the development of instruments to monitor the transformer condition is of great interest. Detection of partial discharges (PDs) in power transformers is an effective diagnostic because it may reveal and quantify an important aging factor and provide information on the condition of the transformer. However, partial discharge diagnostics are still not effectively used for online monitoring of transformers because of the complexity of PD measurements and difficulties of discriminating of PDs and other noise sources. This thesis presents a further study of detection and location of partial discharges in power transformers based on previous work conducted at the Center for Photonics Technology (CPT) at Virginia Tech. The detection and positioning system consists of multiple extrinsic Fabry-Parot interferometric (EFPI) fiber acoustic sensors which can survive the harsh environment of oil-filled transformers. This thesis work is focused on optimal arrangement of multiple sensors to monitor and locate PD activities in a power transformer. This includes the following aspects. First, the sensor design requirements are discussed in order to successfully detect and accurately position the PD sources. In the following sections, Finite Element Method (FEM) is used to model the EFPI sensor fabricated at CPT. Experiments were conducted to measure the angular dependence of the frequency response of the sensor. It is shown that within the range of ±45º incident angles, the sensitivity varies by 3-5dB. Finally, the thesis demonstrates a PD positioning experiment in a 500 gallon water tank (R à H = 74" à 30" cylinder) using a hyperbolic positioning algorithm and time difference of arrival (TDOA). Finally we demonstrated that 100% of the positioning data is bounded by a 22.7à 4.1à 5.3 mm₃ cube, with a sensing range of 810 mm using the leading edge method with FIR filtering. / Master of Science
2

Pushing Forward Distributed Positioning Systems: Unleashing the Potential of Ultrawide-Band Networks

Santoro, Luca 19 April 2024 (has links)
This doctoral thesis presents a comprehensive exploration of ultrawideband technology in addressing diverse challenges within localization systems. Beginning with the development of an innovative, cost-effective, and anonymous contact tracing solution for industrial environments during the COVID-19 pandemic, the research integrates ultra-wideband positioning, Bluetooth low-energy, and inertial measurement units. The subsequent sections delve into relative positioning systems, device-free localization, UWB bistatic radar sensors, and UAV-based tracking, showcasing novel methodologies and hardware implementations with promising outcomes. The work extends to groundbreaking approaches in deploying UWB infrastructure through self-deployable robots and cooperative positioning schemes using a UAV swarm. The contributions highlight versatility, costeffectiveness, and scalability, opening new possibilities for applications in security, logistics, IoT services, and space exploration. In summary, this thesis represents a significant advancement in localization systems, offering practical solutions and paving the way for future research and applications
3

Design of a Dual Band Local Positioning System

Joram, Niko 11 September 2015 (has links)
This work presents a robust dual band local positioning system (LPS) working in the 2.4GHz and 5.8GHz industrial science medical (ISM) bands. Position measurement is based on the frequency-modulated continuous wave (FMCW) radar approach, which uses radio frequency (RF) chirp signals for propagation time and therefore distance measurements. Contrary to state of the art LPS, the presented system uses data from both bands to improve accuracy, precision and robustness. A complete system prototype is designed consisting of base stations and tags encapsulating most of the RF and analogue signal processing in custom integrated circuits. This design approach allows to reduce size and power consumption compared to a hybrid system using off-the-shelf components. Key components are implemented using concepts, which support operation in multiple frequency bands, namely, the receiver consisting of a low noise amplifier (LNA), mixer, frequency synthesizer with a wide band voltage-controlled oscillator (VCO) having broadband chirp generation capabilities and a dual band power amplifier. System imperfections occurring in FMCW radar systems are modelled. Effects neglected in literature such as compression, intermodulation, the influence of automatic gain control, blockers and spurious emissions are modeled. The results are used to derive a specification set for the circuit design. Position estimation from measured distances is done using an enhanced version of the grid search algorithm, which makes use of data from multiple frequency bands. The algorithm is designed to be easily and efficiently implemented in embedded systems. Measurements show a coverage range of the system of at least 245m. Ranging accuracy in an outdoor scenario can be as low as 8.2cm. Comparative dual band position measurements prove an effective outlier filtering in indoor and outdoor scenarios compared to single band results, yielding in a large gain of accuracy. Positioning accuracy in an indoor scenario with an area of 276m² can be improved from 1.27m at 2.4GHz and 1.86m at 5.8GHz to only 0.38m in the dual band case, corresponding to an improvement by at least a factor of 3.3. In a large outdoor scenario of 4.8 km², accuracy improves from 1.88m at 2.4GHz and 5.93m at 5.8GHz to 0.68m with dual band processing, which is a factor of at least 2.8. / Die vorliegende Arbeit befasst sich mit dem Entwurf eines robusten lokalen Positionierungssystems (LPS), welches in den lizenzfreien Frequenzbereichen für industrielle, wissenschaftliche und medizinische Zwecke (industrial, scientific, medical, ISM) bei 2,4GHz und 5,8GHz arbeitet. Die Positionsbestimmung beruht auf dem Prinzip des frequenzmodulierten Dauerstrichradars (frequency modulated continuous wave, FMCW-Radar), welches hochfrequente Rampensignale für Laufzeitmessungen und damit Abstandsmessungen benutzt. Im Gegensatz zu aktuellen Arbeiten auf diesem Gebiet benutzt das vorgestellte System Daten aus beiden Frequenzbändern zur Erhöhung der Genauigkeit und Präzision sowie Verbesserung der Robustheit. Ein Prototyp des kompletten Systems bestehend aus Basisstationen und mobilen Stationen wurde entworfen. Fast die gesamte analoge hochfrequente Signalverarbeitungskette wurde als anwendungsspezifische integrierte Schaltung realisiert. Verglichen mit Systemen aus Standardkomponenten erlaubt dieser Ansatz die Miniaturisierung der Systemkomponenten und die Einsparung von Leistung. Schlüsselkomponenten wurden mit Konzepten für mehrbandige oder breitbandige Schaltungen entworfen. Dabei wurden Sender und Empfänger bestehend aus rauscharmem Verstärker, Mischer und Frequenzsynthesizer mit breitbandiger Frequenzrampenfunktion implementiert. Außerdem wurde ein Leistungsverstärker für die gleichzeitige Nutzung der beiden definierten Frequenzbänder entworfen. Um Spezifikationen für den Schaltungsentwurf zu erhalten, wurden in der Fachliteratur vernachlässigte Nichtidealitäten von FMCW-Radarsystemen modelliert. Dazu gehören Signalverzerrungen durch Kompression oder Intermodulation, der Einfluss der automatischen Verstärkungseinstellung sowie schmalbandige Störer und Nebenschwingungen. Die Ergebnisse der Modellierung wurden benutzt, um eine Spezifikation für den Schaltungsentwurf zu erhalten. Die Schätzung der Position aus gemessenen Abständen wurde über eine erweiterte Version des Gittersuchalgorithmus erreicht. Dieser nutzt die Abstandsmessdaten aus beiden Frequenzbändern. Der Algorithmus ist so entworfen, dass er effizient in einem eingebetteten System implementiert werden kann. Messungen zeigen eine maximale Reichweite des Systems von mindestens 245m. Die Genauigkeit von Abstandsmessungen im Freiland beträgt 8,2cm. Positionsmessungen wurden unter Verwendung beider Einzelbänder durchgeführt und mit den Ergebnissen des Zweiband-Gittersuchalgorithmus verglichen. Damit konnte eine starke Verbesserung der Positionsgenauigkeit erreicht werden. Die Genauigkeit in einem Innenraum mit einer Grundfläche von 276m² kann verbessert werden von 1,27m bei 2,4GHz und 1,86m bei 5,8GHz zu nur 0,38m im Zweibandverfahren. Das entspricht einer Verbesserung um einen Faktor von mindestens 3,3. In einem größeren Außenszenario mit einer Fläche von 4,8 km² verbessert sich die Genauigkeit um einen Faktor von mindestens 2,8 von 1,88m bei 2,4GHz und 5,93m bei 5,8GHz auf 0,68m bei Nutzung von Daten aus beiden Frequenzbändern.