• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 6
  • Tagged with
  • 15
  • 15
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Doppler venoso fetal na insuficiência placentária: relação com o pH no nascimento / Fetal venous Doppler in pregnancies with placental dysfunction: correlation with pH at birth

Cristiane Ortigosa 18 April 2012 (has links)
OBJETIVO: O presente estudo, realizado em gestantes de alto risco com diagnóstico de insuficiência placentária, tem como objetivo avaliar o fluxo sanguíneo fetal na veia portal esquerda (VPE), veia umbilical (VU) e ducto venoso (DV), e estabelecer quais parâmetros associam-se com a acidemia fetal no nascimento. MÉTODO: Pesquisa prospectiva envolvendo 58 gestantes, classificadas segundo a presença ou ausência do diagnóstico de acidemia no nascimento, de acordo com o pH no sangue da artéria umbilical, constituindo-se de: Grupo I: 26 casos (acidemia pH<7,20) e Grupo II: 32 casos (pH normal pH7,20). Foram excluídos da pesquisa os casos com diagnóstico pós-natal de anomalia do RN e aqueles em que não se obteve a mensuração do pH no nascimento. As seguintes variáveis dopplervelocimétricas da VPE e VU foram comparadas entre os grupos: escore-zeta da TAMxV (time averaged maximum velocity) (cm/s), Q/Kg (fluxo sanguíneo por Kg de peso fetal) (ml/min/kg) e presença de pulsatilidade; e o escore-zeta do índice de pulsatilidade para veias (IPV) do DV. RESULTADOS: O escore-zeta da TAMxV (rho=0,392, P=0,002) e o Q/Kg da VPE (rho=0,274, P=0,037), o escore-zeta do IPV do DV (rho=-0,377, P=0,004) e o Q/Kg da VU (rho=0,261, P=0,048) apresentaram correlação significativa com o pH no nascimento. Realizando-se a análise de regressão logística multivariada, as variáveis independentes que restaram no modelo final para a ocorrência de acidemia no nascimento (pH<7,20) foram: escore-zeta da TAMxV da VPE (OR=0,41; IC95% 0,25 a 0,71; P=0,001) e fluxo reverso na VPE (OR=0,004; IC95% 0,00 a 0,15; P=0,003), ambas demonstrando efeito protetor para acidemia. Com o presente modelo, constatou-se que 74,1% dos casos são corretamente classificados para acidemia no nascimento. CONCLUSÕES: pela análise do Doppler venoso fetal na insuficiência placentária constatou-se que a acidemia no nascimento (pH<7,20) está associada de forma independente com o fluxo reverso na VPE e com o escore-zeta da TAMxV da VPE, ambos demonstrando efeito protetor com redução do risco para a acidemia / OBJECTIVE: This study, conducted in high-risk pregnancies with placental insufficiency, aims to avaliate blood flow in the fetal left portal vein (LPV), umbilical vein (UV) and ductus venosus (DV), and establish which parameters are associated with acidemia at birth. METHOD: A prospective research involving 58 pregnant women, classified according to the presence or absence of the diagnosis of fetal acidosis at birth, according to pH in the blood of the umbilical artery, consisting of: Group I: 26 cases (acidemia, pH <7,20) and Group II: 32 cases (normal pH, pH 7,20). Exclusion criteria were patients who had postnatal diagnosis of abnormality of the newborn and those in which the pH measurement was not obtained at birth. The following Doppler variables of LPV and UV were compared between the groups: TAMxV (Time Averaged Maximum Velocity) (cm/s) zeta-score, Q/kg (blood flow per kg of fetal weight) (ml/min/kg) and presence of pulsatility; and DV pulsality index for veins (PIV) zetascore. RESULTS: LPV TAMxV zeta-score (rho=0.392, P=0.002) and Q/kg (rho=0.274, P=0.037), DV PIV zeta-score (rho=-0.377, P=0.004) and UV Q/kg (rho=0.261, P=0.048) showed significant correlation with pH at birth. Performing the multivariate logistic regression analysis, the independent variables that remained in the final model were: TAMxV of LPV zeta-score (OR=0.41; IC95% 0.25 a 0.71; P=0.001) and reverse flow in LPV (OR=0.004; IC95% 0.00 a 0.15; P=0.003), both showing a protective effect to reduce the risk of acidemia. With this model, it was found that 74,1% of cases are correctly classified to birth acidemia. CONCLUSION: by analysis of fetal venous Doppler in placental insufficiency we found that acidemia at birth (pH <7.20) is independently associated with reverse flow in the LPV and LPV TAMxV z-score, both showing a protective effect with reduced risk for the event
12

Cardiotocografia computadorizada e dopplervelocimetria em gestações com insuficiência placentária: associação com a lesão miocárdica fetal e a acidemia no nascimento / Computerized fetal heart rate analysis and Doppler in the prediction of myocardial damage and acidemia at birth in pregnancies with placental insufficiency

Mariane de Fátima Yukie Maeda 23 October 2013 (has links)
Objetivo: Avaliar a relação entre os parâmetros da cardiotocografia computadorizada (cCTG) e da dopplervelocimetria com a lesão miocárdica fetal e com a ocorrência de acidemia no nascimento, em gestações com insuficiência placentária. Métodos: Estudo prospectivo com 49 gestações complicadas pela insuficiência placentária (Doppler de artéria umbilical anormal - índice de pulsatilidade [IP] > p95) diagnosticada entre 26 e 34 semanas. Todas as pacientes foram avaliadas pelo Doppler de artéria umbilical, artéria cerebral média e ducto venoso e pela cCTG (Sonicaid FetalCare, versão 2.2, por 30 minutos). Foi analisada a última avaliação fetal até 48h antes do parto e anterior à corticoterapia. Foi analisado o sangue de cordão umbilical no parto, para detectar a acidemia no nascimento (pH < 7,20) e a lesão miocárdica fetal (Troponina T cardíaca [cTnT] >= 0,09 ng/mL). A cTnT foi obtida em 38 casos e o pH em 46 casos. Resultados: Quinze (39,5%) recém-nascidos apresentaram cTnT >= 0,09 ng/ml e 20 (43,5%) pH < 7,20. Os fetos que evoluíram com acidemia apresentaram menor número de movimentos por hora na cCTG (mediana 2 vs. 15, p=0,019). Houve correlação positiva entre o pH e o número de movimentos fetais por hora (rho=0,35; P=0,019) e com a frequência cardíaca fetal basal (rho 0,37, P=0,011), e correlação negativa entre o pH e o escore zeta do IP para veias (IPV) do ducto venoso (rho= -0,31, P=0,036). A regressão logística identificou o escore-zeta do IPV do ducto venoso (P=0,023) e a frequência cardíaca fetal basal (P=0,040) como variáveis independentes associadas com a acidemia no nascimento. A ocorrência de lesão miocárdica fetal, quando comparada ao grupo com cTnT normal, apresentou associação significativa com o escore zeta do IP da artéria umbilical (mediana 8,8 vs. 4,0; P=0,003), IPV do ducto venoso (mediana 2,6 vs. -1,4; P= 0,007), frequência cardíaca fetal basal (mediana 146 vs. 139 bpm; P=0,033), número de acelerações entre 10-15 bpm (mediana 0 vs. 1; P=0,013), duração dos episódios de baixa variação (mediana 21 vs. 10 min; P=0,038) e a variação de curto prazo (short-term variation-STV) (mediana 3,7 vs. 6,1 ms; P=0,003). Observou-se correlação positiva entre o valor da cTnT no cordão umbilical e a frequência cardíaca fetal basal (rho=0,33; P=0,042), e correlação negativa entre a cTnT e a STV (rho= -0,37; P=0,021). A regressão logística identificou a STV como fator preditor independente para o dano miocárdico fetal (P=0,01), sendo a STV <= 4,3 ms o melhor ponto de corte para predição do evento (sensibilidade de 66,7% e especificidade de 91,3%). Conclusão: Em gestações com insuficiência placentária detectada antes da 34ª semana gestacional, o IPV do ducto venoso e a frequência cardíaca fetal basal analisada pela cCTG são os preditores independentes associados com a acidemia no nascimento; e o valor da STV avaliada pela cCTG é a variável que melhor prediz a lesão miocárdica fetal. A cCTG é ferramenta importante no manejo de fetos com insuficiência placentária, principalmente quando associada a outros métodos propedêuticos como a dopplervelocimetria / Objective: To evaluate the reliability of fetal heart rate parameters analyzed by computerized cardiotocography (cCTG) and fetal Doppler to predict myocardial damage and acidemia at birth in pregnancies complicated by placental insufficiency. Methods: Forty nine patients with placental insufficiency (abnormal umbilical artery Doppler - pulsatility index [PI] > p95) diagnosed between 26-34 weeks of gestation were prospectively studied. All patients were submitted to Dopplervelocimetry of umbilical artery, middle cerebral artery and ductus venosus and to the cCTG (Sonicaid Fetal Care, version 2.2; 30 minutes of duration). We analyzed the last fetal assessment 48h before delivery and prior to steroid therapy.Umbilical cord blood samples were collected at birth to detect acidemia (pH < 7.20) and myocardial damage (cTnT >= 0.09 ng/ml). The results of cTnT were available in 38 cases and in 46 cases we had the pH values. Results: Fifteen (39.5%) newborns had cTnT >= 0.09 ng/ml and 20 (43.5%) had a pH < 7.20. Fetuses who developed acidemia had fewer fetal movements per hour in cCTG (median 2 vs. 15, P=0.019). There was a positive correlation between pH and the number of fetal movements per hour (rho 0.35, P=0.019) and basal fetal heart rate (rho 0.37, P=0.011), and a negative correlation between pH and the zscore of pulsatility index for veins (PIV) of ductus venosus (rho= -0.31, P=0.036). The logistic regression analysis identified the z-score of PIV of ductus venosus (P=0.023) and basal fetal heart rate (P=0.040) as independent variables associated with acidemia at birth. The occurrence of fetal myocardial injury was significantly associated with z-score of PI of umbilical artery (median 8.8 vs. 4.0, P=0.003), PIV of ductus venosus (median 2.6 vs. -1.4, P=0.007), basal fetal heart rate (median 146 vs. 139 bpm, P=0.033), number of accelerations between 10-15 bpm (median 0 vs. 1, P=0.013), duration of episodes of low variation (median 21 vs. 10 min, P=0.038) and short-term variation (STV) (median 3.7 vs. 6.1 ms, P=0.003). We observed a positive correlation between the value of cTnT in the umbilical cord and basal fetal heart rate (rho=0.33, P=0.042), and a negative correlation between cTnT and STV (rho=-0.37, P=0.021). Logistic regression identified the STV as an independent predictor for myocardial damage (P=0.01), and STV <= 4.3 ms was the best cutoff to predict the event (sensitivity 66.7% and specificity of 91.3%). Conclusion: In pregnancies with placental insufficiency detected before the 34th week of gestation, the PIV of ductus venosus and basal fetal heart rate analyzed by cCTG are independent variables associated with acidemia at birth; and the STV is the parameter that best predicts fetal myocardial injury. The cCTG is an important tool in the management of fetuses with placental insufficiency, especially when associated with other diagnostic methods such as Doppler
13

Cardiotocografia computadorizada e dopplervelocimetria em gestações com insuficiência placentária: associação com a lesão miocárdica fetal e a acidemia no nascimento / Computerized fetal heart rate analysis and Doppler in the prediction of myocardial damage and acidemia at birth in pregnancies with placental insufficiency

Maeda, Mariane de Fátima Yukie 23 October 2013 (has links)
Objetivo: Avaliar a relação entre os parâmetros da cardiotocografia computadorizada (cCTG) e da dopplervelocimetria com a lesão miocárdica fetal e com a ocorrência de acidemia no nascimento, em gestações com insuficiência placentária. Métodos: Estudo prospectivo com 49 gestações complicadas pela insuficiência placentária (Doppler de artéria umbilical anormal - índice de pulsatilidade [IP] > p95) diagnosticada entre 26 e 34 semanas. Todas as pacientes foram avaliadas pelo Doppler de artéria umbilical, artéria cerebral média e ducto venoso e pela cCTG (Sonicaid FetalCare, versão 2.2, por 30 minutos). Foi analisada a última avaliação fetal até 48h antes do parto e anterior à corticoterapia. Foi analisado o sangue de cordão umbilical no parto, para detectar a acidemia no nascimento (pH < 7,20) e a lesão miocárdica fetal (Troponina T cardíaca [cTnT] >= 0,09 ng/mL). A cTnT foi obtida em 38 casos e o pH em 46 casos. Resultados: Quinze (39,5%) recém-nascidos apresentaram cTnT >= 0,09 ng/ml e 20 (43,5%) pH < 7,20. Os fetos que evoluíram com acidemia apresentaram menor número de movimentos por hora na cCTG (mediana 2 vs. 15, p=0,019). Houve correlação positiva entre o pH e o número de movimentos fetais por hora (rho=0,35; P=0,019) e com a frequência cardíaca fetal basal (rho 0,37, P=0,011), e correlação negativa entre o pH e o escore zeta do IP para veias (IPV) do ducto venoso (rho= -0,31, P=0,036). A regressão logística identificou o escore-zeta do IPV do ducto venoso (P=0,023) e a frequência cardíaca fetal basal (P=0,040) como variáveis independentes associadas com a acidemia no nascimento. A ocorrência de lesão miocárdica fetal, quando comparada ao grupo com cTnT normal, apresentou associação significativa com o escore zeta do IP da artéria umbilical (mediana 8,8 vs. 4,0; P=0,003), IPV do ducto venoso (mediana 2,6 vs. -1,4; P= 0,007), frequência cardíaca fetal basal (mediana 146 vs. 139 bpm; P=0,033), número de acelerações entre 10-15 bpm (mediana 0 vs. 1; P=0,013), duração dos episódios de baixa variação (mediana 21 vs. 10 min; P=0,038) e a variação de curto prazo (short-term variation-STV) (mediana 3,7 vs. 6,1 ms; P=0,003). Observou-se correlação positiva entre o valor da cTnT no cordão umbilical e a frequência cardíaca fetal basal (rho=0,33; P=0,042), e correlação negativa entre a cTnT e a STV (rho= -0,37; P=0,021). A regressão logística identificou a STV como fator preditor independente para o dano miocárdico fetal (P=0,01), sendo a STV <= 4,3 ms o melhor ponto de corte para predição do evento (sensibilidade de 66,7% e especificidade de 91,3%). Conclusão: Em gestações com insuficiência placentária detectada antes da 34ª semana gestacional, o IPV do ducto venoso e a frequência cardíaca fetal basal analisada pela cCTG são os preditores independentes associados com a acidemia no nascimento; e o valor da STV avaliada pela cCTG é a variável que melhor prediz a lesão miocárdica fetal. A cCTG é ferramenta importante no manejo de fetos com insuficiência placentária, principalmente quando associada a outros métodos propedêuticos como a dopplervelocimetria / Objective: To evaluate the reliability of fetal heart rate parameters analyzed by computerized cardiotocography (cCTG) and fetal Doppler to predict myocardial damage and acidemia at birth in pregnancies complicated by placental insufficiency. Methods: Forty nine patients with placental insufficiency (abnormal umbilical artery Doppler - pulsatility index [PI] > p95) diagnosed between 26-34 weeks of gestation were prospectively studied. All patients were submitted to Dopplervelocimetry of umbilical artery, middle cerebral artery and ductus venosus and to the cCTG (Sonicaid Fetal Care, version 2.2; 30 minutes of duration). We analyzed the last fetal assessment 48h before delivery and prior to steroid therapy.Umbilical cord blood samples were collected at birth to detect acidemia (pH < 7.20) and myocardial damage (cTnT >= 0.09 ng/ml). The results of cTnT were available in 38 cases and in 46 cases we had the pH values. Results: Fifteen (39.5%) newborns had cTnT >= 0.09 ng/ml and 20 (43.5%) had a pH < 7.20. Fetuses who developed acidemia had fewer fetal movements per hour in cCTG (median 2 vs. 15, P=0.019). There was a positive correlation between pH and the number of fetal movements per hour (rho 0.35, P=0.019) and basal fetal heart rate (rho 0.37, P=0.011), and a negative correlation between pH and the zscore of pulsatility index for veins (PIV) of ductus venosus (rho= -0.31, P=0.036). The logistic regression analysis identified the z-score of PIV of ductus venosus (P=0.023) and basal fetal heart rate (P=0.040) as independent variables associated with acidemia at birth. The occurrence of fetal myocardial injury was significantly associated with z-score of PI of umbilical artery (median 8.8 vs. 4.0, P=0.003), PIV of ductus venosus (median 2.6 vs. -1.4, P=0.007), basal fetal heart rate (median 146 vs. 139 bpm, P=0.033), number of accelerations between 10-15 bpm (median 0 vs. 1, P=0.013), duration of episodes of low variation (median 21 vs. 10 min, P=0.038) and short-term variation (STV) (median 3.7 vs. 6.1 ms, P=0.003). We observed a positive correlation between the value of cTnT in the umbilical cord and basal fetal heart rate (rho=0.33, P=0.042), and a negative correlation between cTnT and STV (rho=-0.37, P=0.021). Logistic regression identified the STV as an independent predictor for myocardial damage (P=0.01), and STV <= 4.3 ms was the best cutoff to predict the event (sensitivity 66.7% and specificity of 91.3%). Conclusion: In pregnancies with placental insufficiency detected before the 34th week of gestation, the PIV of ductus venosus and basal fetal heart rate analyzed by cCTG are independent variables associated with acidemia at birth; and the STV is the parameter that best predicts fetal myocardial injury. The cCTG is an important tool in the management of fetuses with placental insufficiency, especially when associated with other diagnostic methods such as Doppler
14

Dopplervelocimetria da artéria cerebral média fetal na predição da acidemia no nascimento em gestações com insuficiência placentária / Fetal middle cerebral artery Doppler in the prediction of acidemia at birth in pregnancies with placental insufficiency

Niigaki, Juliana Ikeda 29 January 2014 (has links)
Objetivo: Avaliar a relação das alterações de fluxo na artéria cerebral média (ACM) com a ocorrência de acidemia no nascimento, em gestações com insuficiência placentária. Métodos: estudo transversal prospectivo com 91 gestações com diagnóstico de insuficiência placentária pelo Doppler de artéria umbilical (AU) alterado (índice de pulsatilidade [IP] > p95). Os critérios de inclusão foram: gestações únicas com idade gestacional (IG) superior a 26 semanas completas, membranas ovulares íntegras, ausência de anomalias cromossômicas ou congênitas. Os parâmetros da dopplervelocimetria analisados foram: IP da AU, IP da ACM, pico de velocidade sistólica (PVS) da ACM, relação cerebroplacentária (RCP) e índice de pulsatilidade para veias (IPV) do ducto venoso (DV). Foi analisada a última avaliação fetal realizada imediatamente antes do parto ou anterior à corticoterapia. Todos os parâmetros foram analisados por meio do escore zeta ou múltiplos da mediana (MoM), baseados nas médias, desvio-padrão e valores de referência para cada IG. Imediatamente após o parto, uma amostra de sangue da artéria umbilical foi obtida para a medida do pH, e os casos classificados de acordo com a presença (pH < 7,20) ou ausência de acidemia no nascimento. Resultados: Quarenta e sete (51,6%) recémnascidos apresentaram acidemia no nascimento. Os fetos que evoluíram com acidemia apresentaram valor de escore zeta do IP da AU significativamente maior (mediana 2,1 vs 1,7; p=0,014), assim como maior proporção de casos com diástole zero ou reversa (51,0% vs 31,8%; p=0,006). Quanto à ACM, o escore zeta mostrou-se significativamente menor nos casos com pH < 7,20 (mediana -2,7 vs -2,1; p=0,042), porém, em relação ao PVS não foi possível estabelecer diferença significativa entre os grupos (p=0,051). A acidemia no nascimento se associou a menores valores de RCP (mediana 0,5 vs 0,7; p=0,006), porém não ao seu escore zeta (p=0,055). Em relação ao território venoso, maiores valores do escore zeta do IPV do DV associaram-se à acidemia (mediana 2,4 vs 0,6; p=0,015). Na análise de correlação entre os valores de pH no nascimento e os resultados da avaliação da dopplervelocimetria fetal, foi constatada correlação significativa entre o valor do pH no nascimento e o escore zeta do IP da AU (rho=-0,31; p=0,003), IP da ACM (rho=0,26; p=0,012), da RCP (rho 0,25; p=0,015) e IPV do DV (rho=-0,32; p=0,002), e PVS da ACM MoM (rho=-0,21; p=0,042). A regressão logística identificou o escore zeta do IP da AU e escore zeta IP da ACM como variáveis independentes para a predição de acidemia no nascimento, classificando corretamente 67,03% dos casos. Conclusão: em casos de insuficiência placentária, o IP da AU e da ACM são preditores independentes associados com a acidemia no nascimento. Este estudo reforça que o grau de insuficiência placentária e a capacidade de adaptação fetal estão diretamente relacionados com a acidemia no nascimento / Objectives: To evaluate the relationship between middle cerebral artery (MCA) parameters and acidemia at birth, in pregnancies complicated by placental insufficiency. Methods: The study was performed as a prospective cross-sectional analysis of Doppler measurements in 91 patients with the diagnosis of placental dysfunction by abnormal umbilical artery (UA) Doppler (pulsatility index [PI] > p95). Inclusion criteria were: singleton pregnancy, intact membranes, abscence of fetal congenital or chromosomal abnormalities. The Doppler parameters analyzed were: UA PI, MCA PI, MCA peak systolic velocity (PSV), cerebroplacental ratio (CPR) and pulsatilility index for veins (PIV) of ductus venosus (DV). It was analyzed the last assessment obtained right before birth or the antenatal steroids. Umbical artey blood samples were collected at birth, and acidemia was defined as pH below 7.20. Results: Forty seven (51.6%) newborns had acidemia at birth. Those who developed acidemia showed a UA PI z-score significantly higher (median 2.1 vs 1.7, p = 0.014), as well as a higher proportion of cases with absent or reverse end diastolic flow (51.0% vs 31.8%, p = 0.006). Regarding the MAC, the PI z-score was significantly lower in cases with pH < 7.20 (median -2.7 vs. -2.1, p = 0.042), but concerning PSV z-score, no significant relation between the groups could be established (p = 0.051).The acidemia at birth was associated with lower values of CPR (median 0.5 vs 0.7, p = 0.006), but not with its z-score (p = 0.055). In relation to the venous territory, greater values of DV PIV z-score were associated with acidemia (median 2.4 vs 0.6, p = 0.015).The correlation analysis between the pH values at birth and the Doppler measurements, a significant correlation was observed between the pH at birth and UA PI z-score (rho = -0.31, p = 0.003 ), MCA PI z-score (rho = 0.26, p = 0.012), CPR z-score (rho 0.25, p = 0.015), PIV DV zscore (rho = -0.32, p = 0.002), and PSV MCA MoM (rho = -0.21, p = 0.042). Logistic regression identified the UA PI z-score and the MCA PI z-score as independent predictors for acidemia at birth, correctly classifying 67.03% of cases. Conclusion: In pregnancies with placental insufficiency, the UA PI and the MCA PI are independent predictors associated with acidemia at birth. This study reinforces that the degree of placental insufficiency and the fetal adaptation capacity are directly related to acidemia at birth
15

Dopplervelocimetria da artéria cerebral média fetal na predição da acidemia no nascimento em gestações com insuficiência placentária / Fetal middle cerebral artery Doppler in the prediction of acidemia at birth in pregnancies with placental insufficiency

Juliana Ikeda Niigaki 29 January 2014 (has links)
Objetivo: Avaliar a relação das alterações de fluxo na artéria cerebral média (ACM) com a ocorrência de acidemia no nascimento, em gestações com insuficiência placentária. Métodos: estudo transversal prospectivo com 91 gestações com diagnóstico de insuficiência placentária pelo Doppler de artéria umbilical (AU) alterado (índice de pulsatilidade [IP] > p95). Os critérios de inclusão foram: gestações únicas com idade gestacional (IG) superior a 26 semanas completas, membranas ovulares íntegras, ausência de anomalias cromossômicas ou congênitas. Os parâmetros da dopplervelocimetria analisados foram: IP da AU, IP da ACM, pico de velocidade sistólica (PVS) da ACM, relação cerebroplacentária (RCP) e índice de pulsatilidade para veias (IPV) do ducto venoso (DV). Foi analisada a última avaliação fetal realizada imediatamente antes do parto ou anterior à corticoterapia. Todos os parâmetros foram analisados por meio do escore zeta ou múltiplos da mediana (MoM), baseados nas médias, desvio-padrão e valores de referência para cada IG. Imediatamente após o parto, uma amostra de sangue da artéria umbilical foi obtida para a medida do pH, e os casos classificados de acordo com a presença (pH < 7,20) ou ausência de acidemia no nascimento. Resultados: Quarenta e sete (51,6%) recémnascidos apresentaram acidemia no nascimento. Os fetos que evoluíram com acidemia apresentaram valor de escore zeta do IP da AU significativamente maior (mediana 2,1 vs 1,7; p=0,014), assim como maior proporção de casos com diástole zero ou reversa (51,0% vs 31,8%; p=0,006). Quanto à ACM, o escore zeta mostrou-se significativamente menor nos casos com pH < 7,20 (mediana -2,7 vs -2,1; p=0,042), porém, em relação ao PVS não foi possível estabelecer diferença significativa entre os grupos (p=0,051). A acidemia no nascimento se associou a menores valores de RCP (mediana 0,5 vs 0,7; p=0,006), porém não ao seu escore zeta (p=0,055). Em relação ao território venoso, maiores valores do escore zeta do IPV do DV associaram-se à acidemia (mediana 2,4 vs 0,6; p=0,015). Na análise de correlação entre os valores de pH no nascimento e os resultados da avaliação da dopplervelocimetria fetal, foi constatada correlação significativa entre o valor do pH no nascimento e o escore zeta do IP da AU (rho=-0,31; p=0,003), IP da ACM (rho=0,26; p=0,012), da RCP (rho 0,25; p=0,015) e IPV do DV (rho=-0,32; p=0,002), e PVS da ACM MoM (rho=-0,21; p=0,042). A regressão logística identificou o escore zeta do IP da AU e escore zeta IP da ACM como variáveis independentes para a predição de acidemia no nascimento, classificando corretamente 67,03% dos casos. Conclusão: em casos de insuficiência placentária, o IP da AU e da ACM são preditores independentes associados com a acidemia no nascimento. Este estudo reforça que o grau de insuficiência placentária e a capacidade de adaptação fetal estão diretamente relacionados com a acidemia no nascimento / Objectives: To evaluate the relationship between middle cerebral artery (MCA) parameters and acidemia at birth, in pregnancies complicated by placental insufficiency. Methods: The study was performed as a prospective cross-sectional analysis of Doppler measurements in 91 patients with the diagnosis of placental dysfunction by abnormal umbilical artery (UA) Doppler (pulsatility index [PI] > p95). Inclusion criteria were: singleton pregnancy, intact membranes, abscence of fetal congenital or chromosomal abnormalities. The Doppler parameters analyzed were: UA PI, MCA PI, MCA peak systolic velocity (PSV), cerebroplacental ratio (CPR) and pulsatilility index for veins (PIV) of ductus venosus (DV). It was analyzed the last assessment obtained right before birth or the antenatal steroids. Umbical artey blood samples were collected at birth, and acidemia was defined as pH below 7.20. Results: Forty seven (51.6%) newborns had acidemia at birth. Those who developed acidemia showed a UA PI z-score significantly higher (median 2.1 vs 1.7, p = 0.014), as well as a higher proportion of cases with absent or reverse end diastolic flow (51.0% vs 31.8%, p = 0.006). Regarding the MAC, the PI z-score was significantly lower in cases with pH < 7.20 (median -2.7 vs. -2.1, p = 0.042), but concerning PSV z-score, no significant relation between the groups could be established (p = 0.051).The acidemia at birth was associated with lower values of CPR (median 0.5 vs 0.7, p = 0.006), but not with its z-score (p = 0.055). In relation to the venous territory, greater values of DV PIV z-score were associated with acidemia (median 2.4 vs 0.6, p = 0.015).The correlation analysis between the pH values at birth and the Doppler measurements, a significant correlation was observed between the pH at birth and UA PI z-score (rho = -0.31, p = 0.003 ), MCA PI z-score (rho = 0.26, p = 0.012), CPR z-score (rho 0.25, p = 0.015), PIV DV zscore (rho = -0.32, p = 0.002), and PSV MCA MoM (rho = -0.21, p = 0.042). Logistic regression identified the UA PI z-score and the MCA PI z-score as independent predictors for acidemia at birth, correctly classifying 67.03% of cases. Conclusion: In pregnancies with placental insufficiency, the UA PI and the MCA PI are independent predictors associated with acidemia at birth. This study reinforces that the degree of placental insufficiency and the fetal adaptation capacity are directly related to acidemia at birth

Page generated in 0.0386 seconds