• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2051
  • 1838
  • 332
  • 200
  • 173
  • 163
  • 157
  • 109
  • 80
  • 41
  • 29
  • 29
  • 21
  • 20
  • 19
  • Tagged with
  • 5831
  • 1437
  • 1189
  • 885
  • 811
  • 692
  • 587
  • 585
  • 581
  • 566
  • 450
  • 393
  • 369
  • 361
  • 354
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

An investigation of the impact of the local labour markets on staff shortages and staff mix of hospitals in England and France

Combes, Jean-Baptiste January 2012 (has links)
No description available.
142

Legionellae and the hospital environment

Makin, Thomas January 1995 (has links)
This thesis investigates the distribution of legionellae in water systems in the Royal Liverpool University Hospital (RLUH) and examines some of the factors that affect colonisation by these organisms. The effect of persistent contamination of the domestic water system on immunocompromised patients was monitored, and the envirorunental control of legionellae by various methods was assessed. A fluorescent monoclonal antibody (DFA) was evaluated for its ability to detect L. pneumophila in domestic and cooling water, and was highly sensitive and specific for this purpose. DFA detected non-culturable L. pneumophila in the cold water system (CWS) that were not recovered following heat shock procedures. Legionellae were not isolated from air conditioning humidifiers, and were rarely detected in cooling towers despite treatment with inadequate concentrations of biocide. A high pH assisted in preventing legionella colonisation. Calorifier sediment contained legionellae and high levels of insoluble copper oxides. Culture media and a low pH, released Cuions from sediment which were markedly inhibitory to legionellae. Low concentrations of Cuions were detected in domestic hot water. At temperatures below 60°C legionellae were detected in the hot water supply to the wards, and calorifiers were regularly re-seeded by legionellae returning from contaminated peripheral parts of the system. Legionellae were not detected in the HWS when 60°C was achieved. L. pneumophila sgps 6, 12 and L. bozemanii predominated in domestic water. L. pneumophila sgp 1 was detected on one occasion only in a cold water storage tank and a calorifier, and did not colonise any of the water systems. L. pneumophila sgps 6 and 12 were isolated from three nosocomial cases of Legionnaires' disease. Endemic legionellae prepared as yolk sac antigens, detected significant titres of legionella antibodies (~ 1 :64) in samples from six subjects which did not react ( < 1: 16) with the PHLS L. pneumophUa sgp 1 yolk sac antigen. Most raised titres were to L. pneumophila sgp 12, and the highest titre in heterologous responses identified the infecting serogroup of L. pneumophila. Routine culture of respiratory samples from susceptible patients. detected only one undiagnosed case of Legionnaires' disease. Legionellae were not detected in water from showers that were regularly flushed or irradiated with UV light. Re-colonisation of showers by legionellae was closely associated with the reappearance of amoebae. A trace heating element was effective at maintaining dead-legs at 50°C (± 1.5) and reduced legionellae in these sites. Legionellae proliferated where pipes and heating element were not adequately insulated. Re-circulating the HWS through dead-legs eradicated legionellae from this site but resulted in heavy colonisation of adjacent mixer valves. Automatic drain valves failed to prevent legionellae from colonising shower hoses and mixer valves, and hyperchlorination of shower hoses and water strainers had only a short term effect. Showers heated electrically at point of use were not colonised by legionellae entering in the CWS, or by wild strains of legionellae introduced with calorifier sediment. This appeared to be due to rapid throughput of water, extensive use of copper, and pasteurisation of calorifier contents following discharge of heat from the heating elements, after the shower ceased operating.
143

Characterization and comparison of outpatient pharmaceutical services provided by university of medical school-affiliated hospitals and regions 8 and 9 community hospitals

Wallner, Jon Neil January 1979 (has links)
No description available.
144

Sleep deprivation in subjects undergoing cardiac bypass surgery

Severt, Suzanne Martha January 1979 (has links)
No description available.
145

Invasion of territorial and personal space as perceived by the surgical patient

Donahue, Donna Mae January 1980 (has links)
No description available.
146

Patient response to transfer from the coronary care unit

Verran, Joyce Ann, 1941- January 1970 (has links)
No description available.
147

The effects of an outpatient pharmacy on the acquisition of prescription medications by emergency room patients

Tackitt, Robert Duane, 1941- January 1973 (has links)
No description available.
148

Educational programs for hospitalized children in the United States

Scott, Christine Kathy, 1948- January 1976 (has links)
No description available.
149

Elements of the play behavior of the preschool hospitalized child an ethological approach

McDougall, Ruth Ann, 1943- January 1972 (has links)
No description available.
150

Pharmacy services in U.S. military and Public Health Service hospitals

Smith, Lamar Richard, 1930- January 1972 (has links)
No description available.

Page generated in 0.054 seconds