• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 251
  • 85
  • 43
  • 21
  • 19
  • 15
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • Tagged with
  • 538
  • 538
  • 92
  • 89
  • 64
  • 49
  • 46
  • 46
  • 44
  • 41
  • 35
  • 33
  • 32
  • 31
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Evaluation of temperature fields in two dynamic phantoms heated by the ferromagnetic implant hyperthermia

Lim, Junghwan, 1961- January 1988 (has links)
Two experimental dynamic phantoms have been used for studying temperature distributions induced by interstitial ferromagnetic implant hyperthermia at various blood perfusions, Curie point implants, and input power levels. One of the phantoms is an axially perfused hollow cylinder filled with 3 mm diameter glass beads, and the other is a similar cylinder model that is radially perfused. Analytic models have been developed for evaluating temperature profiles within the two phantoms. Experimental results from the phantoms compare reasonably well with the analytical results. A qualitative comparison is made between thermal profiles derived from both a convection energy equation, for a homogeneous porous medium, and a bioheat transfer equation. The adequacy of using a porous material for simulating living tissue is discussed. Parametric studies showing the effects of various implant parameters such as Curie point and applied power are analyzed.
42

Studies on the mechanism of intestinal iron absorption with special reference to its intracellular transport

Snape, Susan Dawn January 1990 (has links)
No description available.
43

Development of a three-dimensional anthropometry system for human body composition assessment

Yu, Wurong, 1975- 10 September 2012 (has links)
The prevalence of obesity has made it necessary to develop a convenient, reliable and safe tool for timely assessing and monitoring this condition in public health. We suggest that three-dimensional (3D) anthropometry can provide a convenient, accommodating and comprehensive means to body composition assessment. A 3D anthropometry system based on stereo vision technology is developed. To make it more portable and affordable, the system is reduced to a two-stance design and only uses off-the-shelf components. The system is calibrated in two separate stages: camera calibration and 3D registration. The first stage is relatively complicated, but there is no need to repeat frequently. Therefore, only 3D registration is required when the system is transported. This property contributes to the portability and also reduces cost of maintenance. In this system, image acquisition can be completed in 200 ms, which is important in reducing artifacts caused by slight body movement. However, the computation in stereo vision is complex and intensive, and is still a challenge. A two-phase stereo matching algorithm is developed. In the first phase, the foreground is accurately segmented with the help of a predefined virtual interface, and a coarse disparity map is generated with block matching. In the second phase, local least squares matching is performed in combination with global optimization within a regularization framework, so as to ensure both accuracy and reliability. To make the 3D data more interpretable and manageable, it is essential to convert the raw 3D data to a surface model. For our system, a unique challenge is that there are large gaps in the data caused by occlusions. An effective surface reconstruction algorithm based on subdivision surface representation is developed. It has been verified that the algorithm is reliable in gap closing, accurate in representation, and efficient in data compression. To make the 3D anthropometry system ready for practical use, a body measurement system dedicated to body composition assessment is developed based on an earlier system that was designed for applications in apparel fitting. The functions of 3D measurement are enhanced by taking advantage of modern graphics hardware. The overall performance of the presented system has been evaluated on mannequins and human subjects. It has been shown that the measurements are highly repeatable. The feasibility of 3D anthropometry in body fat assessment has been demonstrated in comparison to air displacement plethysmography and bioimpedance analysis. / text
44

A comparison of body fat percentage estimates between duel-energy X-ray absorptiometry and air displacement plethysmography

Nowak, Kathryn M. January 2005 (has links)
Assessment of body fat percentage is desirable to identify health risks associated with obesity. There are few studies that have compared the assessment of body fat between air displacement plethysmography and dual-energy x-ray absorptiometry, particularly related to age and gender differences. The purpose of this study was to determine if body fat percent estimates differ depending on age and/or gender between air displacement plethysmography (Bod Pod, Life Measurements Instrument, Concord, CA) and dual-energy x-ray absorptiometry (DEXA, General Electric Medical Systems, Lunar Prodigy, Madison, WI). Sixty subjects were studied: 15 men and 15 women, 22-35 years and 15 men and 15 women, 55-80 years. Subjects were excluded if they competed in athletics or high-level exercise training in the last year. Standard calibration and testing procedures were used for both methods. Both methods were administered at least twice to evaluate reliability and were repeated a third time if the first two measures differed by >2%. Differences between methods for age groups and gender were analyzed using ANOVA and reliability comparisons between the body composition methods were evaluated with correlation coefficients and Bland-Altman plots. Using data for all subjects, DEXA (r = .996) and Bod Pod (r = .985) both showed good reliability. However, in younger females the reliability of the Bod Pod (r = .911) was lower. Sixteen of the 60 subjects required a third trial for the Bod Pod, whereas all repeated DEXA measures were consistent. The deviation between trial 1 and 2 for the DEXA (.6%) was significantly less than that in the Bod Pod (1.5%). Significant interactions between the body composition method and age group were found. Mean body fat percentage in the younger group was higher in the DEXA (24.1 + 1.1%) than the Bod Pod (23.0 + 1.3%) however, in the older group it was found to be lower in the DEXA (33.9 ± 1.1%) than the Bod Pod (37.2 ± 1.3%). Both the DEXA and the Bod Pod were reliable but repeated DEXA measures were more consistent than the Bod Pod measures. Bod Pod estimates of body fat percentage were lower for younger subjects, yet higher for older subjects compared to DEXA measurements. / School of Physical Education, Sport, and Exercise Science
45

An explication of the problems with apparel fit experienced by female Kenyan consumers in terms of their unique body shape characteristics

Mastamet-Mason, Anne. January 2009 (has links)
Thesis (Ph.D.(Consumer Science)) -- University of Pretoria, 2009. / Summary in English. Also available in print. Includes bibliographical references.
46

The politics of presence stagecraft and the power of the body in the romantic imagination /

Nuss, Melynda. January 2003 (has links) (PDF)
Thesis (Ph. D.)--University of Texas at Austin, 2003. / Vita. Includes bibliographical references. Available also from UMI Company.
47

From the beginning gender and the theology of the body /

Bittle, Fred L. January 2003 (has links)
Thesis (M. Div.)--St. Vladimir's Orthodox Theological Seminary, Crestwood, N.Y., 2003. / Abstract. Includes bibliographical references (leaves 99-102).
48

From the beginning gender and the theology of the body /

Bittle, Fred L. January 2003 (has links) (PDF)
Thesis (M. Div.)--St. Vladimir's Orthodox Theological Seminary, Crestwood, N.Y., 2003. / Abstract. Includes bibliographical references (leaves 99-102).
49

Studies in Levitical reproductive impurity

Whitekettle, Richard W., January 1994 (has links)
Thesis (Th. M.)--Westminster Theological Seminary, Philadelphia, 1994. / Typescript. Includes bibliographical references (leaves 95-98).
50

A three-dimensional modifiable computer body model and its applications

Kim, Yongmin. January 1982 (has links)
Thesis (Ph. D.)--University of Wisconsin--Madison, 1982. / Typescript. Vita. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 231-237).

Page generated in 0.0557 seconds