Signal Processing of UWB Radar Signals for Human Detection Behind WallsMabrouk, Mohamed Hussein Emam Mabrouk January 2015 (has links)
Non-contact life detection is a significant component of both civilian and military rescue applications. As a consequence, this interest has resulted in a very active area of research. The primary goal of this research is reliable detection of a human breathing signal. Additional goals of this research are to carry out detection under realistic conditions, to distinguish between two targets, to determine human breathing rate and estimate the posture. Range gating and Singular Value Decomposition (SVD) have been used to remove clutter in order to detect human breathing under realistic conditions. However, the information of the target range or what principal component contains target information may be unknown. DFT and Short Time Fourier Transform (STFT) algorithms have been used to detect the human breathing and discriminate between two targets. However, the algorithms result in many false alarms because they detect breathing when no target exists. The unsatisfactory performance of the DFT-based estimators in human breathing rate estimation is due to the fact that the second harmonic of the breathing signal has higher magnitude than the first harmonic. Human posture estimation has been performed by measuring the distance of the chest displacements from the ground. This requires multiple UWB receivers and a more complex system. In this thesis, monostatic UWB radar is used. Initially, the SVD method was combined with the skewness test to detect targets, discriminate between two targets, and reduce false alarms. Then, a novel human breathing rate estimation algorithm was proposed using zero-crossing method. Subsequently, a novel method was proposed to distinguish between human postures based on the ratios between different human breathing frequency harmonics magnitudes. It was noted that the ratios depend on the abdomen displacements and higher harmonic ratios were observed when the human target was sitting or standing. The theoretical analysis shows that the distribution of the skewness values of the correlator output of the target and the clutter signals in a single range-bin do not overlap. The experimental results on human breathing detection, breathing rate, and human posture estimation show that the proposed methods improve performance in human breathing detection and rate estimation.
|
Page generated in 0.1059 seconds