• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 1
  • 1
  • Tagged with
  • 19
  • 19
  • 14
  • 14
  • 13
  • 11
  • 10
  • 10
  • 8
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Reator anaeróbio híbrido para tratamento de esgoto sanitário / Hybrid anaerobic reactor for domestic sewage treatment

Passig, Fernando Hermes 11 March 2005 (has links)
Este trabalho de investigação refere-se ao uso do reator anaeróbio híbrido para tratamento de esgoto sanitário, com configuração baseada no reator anaeróbio de manta de lodo (UASB) com inclusão de: meio suporte sobre as calhas de coleta de gás (denominado reator anaeróbio híbrido - UAHB) e, também, meio suporte na zona de reação (denominado reator anaeróbio híbrido modificado - UAHBmod). Para o desenvolvimento desta pesquisa, no Campus I da USP de São Carlos-SP foram construídos dois reatores experimentais de 18,8 m3 cada: um reator UASB, com função de controle, e um reator UAHB. Primeiramente os reatores foram operados por período de 200 dias, com tempo de detenção hidráulica (TDH) de 6 h. Após serem inoculados, com 80 dias de operação, os reatores atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média de DQO, de 84% e 85% e de DBO de 87% e 91%, respectivamente para o UASB e o UAHB. Após esse período, os reatores foram submetidos a aumento da velocidade ascensional (Vasc) (mediante recirculação do efluente) de 0,78 m.h-1; 1,17 m.h-1; 1,56 m.h-1 e de 1,96 m.h-1. O UAHB mostrou ser menos susceptível ao aumento da Vasc do que o UASB. Além da análise da operação dos reatores, foram realizados os ensaios hidrodinâmicos e avaliada a estrutura da comunidade microbiana, por microscopia ótica, epifluorescência e pela técnica do DGGE. Após esse período preliminar, os reatores UAHB e UAHBmod, operados com TDH de 6h e Vasc de 0,78 m.h-1, atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média da matéria orgânica, de 71% e 76% em DQO, e de 72% e 87% em DBO, respectivamente para o UAHB e UAHBmod. Após este período, o reator UAHBmod, submetido a Vasc de 1,56 m.h-1, promoveu remoção de 74% de DQO, e de 87% de DBO. / This research refers to the use of a hybrid anaerobic reactor (UAHB) for domestic wastewater treatment. The configuration of this reactor is based on a sludge bed anaerobic reactor (UASB); in the first instance, a media support above the gas collection apparatus (also known as hybrid anaerobic reactor) was provided and later, a media support on the reaction zone (also known as hybrid modified anaerobic reactor - UAHBmod) was provided. Two reactors, with a volume of 18.8 m3, each, were built for this research at Campus I, USP in São Carlos - SP-Brazil. One UASB reactor acted as a control, and the other as a UAHB reactor. In the preliminary essays, the reactors were operated with 6h of hydraulic detention time (HDT) for 200 days. After inoculation, the reactors attained the apparent dynamic equilibrium state after 80 days of operation, with alkalinity generation, low volatile acids concentration and mean organic matter removal of 84% and 85% in terms of COD, and 87% and 91% in terms of BOD, for UASB and UAHB reactors, respectively. After this period, the reactors were submitted to an increasing in up velocity (Vup) of 0.78 m.h-1; 1.17 m.h-1; 1.56 m.h-1 and 1.96 m.h-1. The UAHB reactor showed lesser susceptibility for Vup increase than the UASB reactor. Hydrodynamic tests were also done on the reactors, in addition to routine operational analysis. The structure of the microbial community was evaluated by optical and epifluorescence microscopy, and the DGGE technique. After this step, the UAHB and the UAHBmod reactors were operated out 6h of HDT and Vup of 0.78 m.h-1. The reactors attained the apparent dynamic equilibrium state with alkalinity generation, low volatile acids concentration and mean organic matter removal of 71% and 76% in terms of COD, and 72% and 87% in terms of BOD for the UASB and UAHBmod reactors, respectively. After this period, the UAHBmod reactor was subjected to a Vup of 1.56 m.h-1 and achieved removal efficiencies of 74% COD and 87% BOD.
12

Análise comparativa do desempenho de reator anaeróbio híbrido e reator de manto de lodo de fluxo ascendente (UASB) aplicados ao tratamento de esgoto sanitário

Hoyos, Nestor Leonel Muñoz January 2016 (has links)
O presente trabalho teve como objetivo principal avaliar a performance e a estabilidade operacional de uma nova configuração de um reator anaeróbio híbrido (RAH) que combina um filtro anaeróbio de fluxo descendente seguido de uma câmara de manta de lodo de fluxo ascendente comparativamente ao reator UASB nas mesmas condições operacionais aplicados ao tratamento de esgoto sanitário. A avaliação da eficiência de remoção de remoção da matéria orgânica e dos sólidos suspensos nos reatores piloto foi por meio de testes da DQO, DBO, sólidos em suspensão totais (SST) e dos sólidos em suspensão voláteis (SSV).Os reatores UASB e RAH foram operados por um período de 240 dias na fase 1 e 150 dias na fase 2 com vazão afluente de 1,6 m3/h e TDH de 11,8 h. O TDH médio na câmara de entrada do RAH foi de 2,7h e de 9,1h na câmara ascendente de manto de lodo. Os reatores piloto apresentaram capacidade de tratamento para suportar os choques de carga orgânica devido à variabilidade do esgoto bruto. A eficiência de remoção de matéria orgânica em termos de DQO foi de 66% e 59% para o UASB e RAH, a eficiência de remoção de SST atingiu valores de 65% e 63% respectivamente, aliás, o reator UASB apresentando valores superiores de desempenho operacional em quase todos os parâmetros de monitoramento dos processos de digestão anaeróbia os valores médios dos parâmetros DQO, DBO5, SST e SSV não tiveram diferenças estatisticamente significativas. O pH para os sistemas piloto esteve na faixa ideal para o desenvolvimento dos microorganismos anaeróbios (6,5 a 7,5) e a alcalinidade e os AGVs demonstraram estabilidade dos reatores, corroborados pela estabilidade do pH no interior de cada sistema. A velocidade ascensional na câmara de manta de lodo (0,45 m/h) não causou efeito adverso na qualidade do efluente em termos de SST, com valor médio de 39,8 mg/L, na mesma faixa observada no reator UASB (41,6 mg/L). Foi observada menor concentração de biomassa no reator RAH (distribuição vertical) comparativamente ao reator UASB segundo os perfis verticais de lodo, entretanto, este fato não comprometeu a sua eficiência de remoção de matéria orgânica e dos sólidos suspensos. A retirada do lodo de excesso dos sistemas piloto foi baseada na relação STV/ST para estimar a fração de biomassa, a freqüência do descarte foi de 1 vez por mês retirando o equivalente aos 10% do volume de lodo das tomadas que apresentaram uma fração de STV menor que 50%. É viável a implementação da turbidez como parâmetro de detenção de perdida de lodo no efluente dos reatores anaeróbios devido a que a turbidez e os SST apresentaram uma relação direta o que ajudaria a simplificar mecanismos de controle operacional para a toma de decisões nas estações de tratamento, sendo que a turbidez é um parâmetro de leitura rápida “in situ” e poderia advertir do excesso de lodo ao interior do reator. Foram empregados diferentes métodos titrimétricos para a determinação dos AGVs no efluente do RAH e UASB. Após análise dos resultados, recomenda-se o uso do método de KAPP e RIPLEY para a determinação dos AGVs pela simplicidade metodológica e pela rapidez na obtenção do resultado. / This study aimed to evaluate the performance and operational stability of a new configuration of a hybrid anaerobic reactor (RAH) combining an anaerobic filter downflow followed by a sludge blanket chamber upflow compared to UASB in same operating conditions applied to sewage treatment. The evaluation of organic matter removal and removal efficiency of suspended solids in the pilot reactor was by testing COD, BOD, total suspended solids (TSS) and volatile suspended solids (VSS). The RAH and UASB reactors were operated for a period of 240 days in the first phase and 150 days in phase 2 with the inlet flow of 1,6 m3/h and 11,8h TDH. The average TDH RAH in the inlet chamber was 2.7h and 9,1h in ascending chamber sludge blanket. Pilot reactors showed treatment capacity to support organic shock loads due to the variability of raw sewage. The organic matter removal efficiency in terms of COD was 66% and 59% for the UASB and RAH, the TSS removal efficiency reached values of 65% and 63% respectively, by the way, the UASB presenting performance values higher operational in almost all parameters of the monitoring anaerobic digestion processes mean values of the parameters COD, BOD5, TSS and VSS were not statistically significant differences. The pH for the pilot systems was in the ideal range for the development of anaerobic microorganisms (6,5 to 7,5) and alkalinity and Volatile Fatty Acids (VFA) demonstrated stability of reactors corroborated by the pH stability within each system. The upflow velocity in the sludge blanket chamber (0,45 m/h) caused no adverse effect on effluent quality in terms of TSS, with an average of 39,8 mg/L, in the same range observed in UASB (41,6 mg/L). It was observed lower concentration of biomass in the reactor RAH (vertical distribution) compared to UASB second vertical sludge profiles, however, this fact did not compromise its removal efficiency of organic matter and suspended solids. The withdrawal of the pilot systems excess sludge was based on TSV/TS ratio to estimate the biomass fraction, the frequency of disposal was 1 once a month by removing the equivalent of 10% of the outlets sludge volume that had a fraction of TSV less than 50%. The implementation of turbidity as sludge lost detention parameter is viable in the effluent of the anaerobic reactors due to turbidity and TSS showed a direct relationship which would help simplify operational control mechanisms for decision making in treatment plants, wherein the turbidity is a quick read parameter "in situ" and could warn of excess sludge inside the reactor. Different titrimetric methods were employed for the determination of VFA and the effluent from the UASB and RAH. After analyzing the results, we recommend the use of KAPP and RIPLEY method for the determination of VFA by methodological simplicity and speed in obtaining results.
13

Avaliação da performance de um reator anaeróbio híbrido (RAH) e da atividade das populações de microrganismos anaeróbios na ausência e na presença de Pentaclorofenol (PCP) / not available

Montenegro, Martha de Almeida Prado 01 June 2001 (has links)
O presente trabalho foi desenvolvido com o objetivo de verificar a eficiência de um reator anaeróbio híbrido (RAH) alimentado com uma mistura de ácidos orgânicos acético, propiônico, butírico, e láctico, bem como do álcool metanol, perfazendo uma DQO de 6,88 g/L, e avaliar nessas condições, a degradação do pentaclorofenol (PCP) na faixa de 2,0 a 21,0 mg/L. O RAH apresentou adequada performance na ausência de PCP, tendo sido inoculado com um lodo com AME cerca de 0,57 g DQO-CH4/g SV.d. Durante os 21 meses de operação do RAH na ausência de PCP verificou-se uma remoção média de DQO de 93% produção média de metano de 84%. Através de testes de toxicidade realizadas em batelada com o lodo granulado do RAH, antes da adição de PCP no reator, calculou-se o IC50, cujos valores foram 10, 12 e 13,69 mg/L. Na presença de PCP na faixa de 2,0 a 2,1 mg/L, o RAH apresentou remoção média de DQO de 96,7%, produção média de metano de 85,5% e remoção dos ácidos voláteis próxima a 74% do acético, 93% do butírico e 64% do propiônico. Individualmente, na presença da maior concentração de PCP adicionada, ocorreu decréscimo na remoção dos ácidos voláteis, principalmente do ácido propiônico e na taxa de conversão DQO/biogás. O PCP foi removido do sistema na ordem de 99% pela ação do lodo granulado com predominância do grupo das Archaea metanogênicas, verificada por exames microscópicos e hibridação \"in situ\". Valores da ordem de grandeza microbiana para os microrganismos metanogênicos nos períodos anteriores e posteriores a adição de PCP permaneceram na faixa de 105 e 106 céls./mL, quando cultivados em metanol e lactato mais sulfato, respectivamente. Os resultados sugerem que as Archaea metanogênicas podem estar envolvidas na degradação do PCP. A velocidade de remoção do organoclorado foi igual a 1,07 mg PCP/g SV.d quando a maior concentração de PCP foi estudada (21,0 mg/L). / The present research aimed to verify the efficiency of an Anaerobic Hybrid Reactor (AHR) supplied with a mixture of fatty acids, acetic, propionic, butyric and lactic and methanol as well. The total amount of COD was 6.88 g/L. The performance of the reactor was remarkably stable and efficient during PCP additions at range from 2.0 to 21.0 mg/L. The AHR showed a great performance in the PCP absence, inoculated with sludge with an specific methanogenic (SMA) activity of 0,057 g.COD-CH4/g. VS.d. During the 21 months of operation without PCP, the reduction of COD was around 93% and methane was up to 84% in the biogas. Before PCP addiction, two toxicity batch tests conducted with the granular sludge presented IC50 values around 10.12 mg/L and 13.69 mg/L. In the presence of PCP, at the range of 2.0 to 21.0 mg/L, the efficiency of volatile fatty acids breakdown was 93%, 64% and 74% respectively for butyric, propionic and acetic acids. Individually, at the presence of the higher PCP concentration studied, a decrease in the conversion of COD to biogas and organic acids removal occurred, mainly with propionic acid. PCP total removal of more than 99% was reached by granular sludge activities formed by the total time of reactor operation with a prevalence of methanogenic Archaea, verified under direct microscopy exams and in situ hybridization. Methanogenic cells predominance was noticed with 105 to 106 cells/mL during enumeration on methanol and lactate plus sulfate culture media, respectively. The results suggest that methanogenic Archaea can be involved in PCP degradation. The organochlorine removal rate was 1.07 mg PCP.g-1 VS.d-1 during the highest PCP (21.0 mg/L) concentration addition.
14

Žemaičių Naumiesčio anaerobinės nuotekų valyklos veikimo efektyvumo įvertinimas / Zemaiciu Naumiescio valuation of anaerobic wastewater effeciency

Krukas, Donatas 08 August 2007 (has links)
Lietuvoje, tvarkant nedidelius nuotekų kiekius iškyla nemažai sunkumų. Labai svarbu parinkti tokią technologiją, kurią taikant nuotekos būtų išvalomos iki nustatytų normų, ji būtų nesudėtinga ir pigi.. Anaerobinėse nuotekų valyklose nenaudojama elektra. Tai yra šių nuotekų valyklų privalumas, tačiau jose iškyla problemų valant nuotekas iki leistinų koncentracijų. Magistrantūros baigiamąjame darbe apibendrinti 2004 – 2006 m. atlikti Šilutės r. Žemaičių Naumiesčio nuotekų valyklos veikimo efektyvumo tyrimai ir analizuojamos priežastys, dėl kurių nepakankamai išvalomos nuotekos. Nustatyta nuotekų išbuvimo anaerobiniame hibridiniame įrenginyje trukmė ir apskaičiuotas jo tūrio panaudojimo koeficientas. Gauta, kad panaudojama tik maža įrenginio tūrio dalis dėl netolygaus nuotekų pasiskirstymo anaerobinio įrenginio talpykloje. / In Lithuania the problem of low wastewater treatment efficiency in anaerobic hybrid reactors also rised. It was determined that one of main reasons of bad wastewater treatment quality in anaerobic hybrid reactors was insufficient volume of equipment and the equipment would be cheap and not complicated. In anaerobic wastewater are not used an electricity. And it is an advantage of wastewater, but there are also problems in cleaning wastewater until permissible concentrations. In the article are generalized 2004-2006 year researches Silutes area in Zemaiciu Naumiestis about wastewater treatment efficiency and analysed reasons for which are insufficient cleaned wastewater treatment. In anaerobic hybrid reactor the efficiency of wastewater treatment depends on volume load. There are found, that are used just small part of volumetric load because of uneven wastewater repartition in anaerobic reactor repository.
15

Análise comparativa do desempenho de reator anaeróbio híbrido e reator de manto de lodo de fluxo ascendente (UASB) aplicados ao tratamento de esgoto sanitário

Hoyos, Nestor Leonel Muñoz January 2016 (has links)
O presente trabalho teve como objetivo principal avaliar a performance e a estabilidade operacional de uma nova configuração de um reator anaeróbio híbrido (RAH) que combina um filtro anaeróbio de fluxo descendente seguido de uma câmara de manta de lodo de fluxo ascendente comparativamente ao reator UASB nas mesmas condições operacionais aplicados ao tratamento de esgoto sanitário. A avaliação da eficiência de remoção de remoção da matéria orgânica e dos sólidos suspensos nos reatores piloto foi por meio de testes da DQO, DBO, sólidos em suspensão totais (SST) e dos sólidos em suspensão voláteis (SSV).Os reatores UASB e RAH foram operados por um período de 240 dias na fase 1 e 150 dias na fase 2 com vazão afluente de 1,6 m3/h e TDH de 11,8 h. O TDH médio na câmara de entrada do RAH foi de 2,7h e de 9,1h na câmara ascendente de manto de lodo. Os reatores piloto apresentaram capacidade de tratamento para suportar os choques de carga orgânica devido à variabilidade do esgoto bruto. A eficiência de remoção de matéria orgânica em termos de DQO foi de 66% e 59% para o UASB e RAH, a eficiência de remoção de SST atingiu valores de 65% e 63% respectivamente, aliás, o reator UASB apresentando valores superiores de desempenho operacional em quase todos os parâmetros de monitoramento dos processos de digestão anaeróbia os valores médios dos parâmetros DQO, DBO5, SST e SSV não tiveram diferenças estatisticamente significativas. O pH para os sistemas piloto esteve na faixa ideal para o desenvolvimento dos microorganismos anaeróbios (6,5 a 7,5) e a alcalinidade e os AGVs demonstraram estabilidade dos reatores, corroborados pela estabilidade do pH no interior de cada sistema. A velocidade ascensional na câmara de manta de lodo (0,45 m/h) não causou efeito adverso na qualidade do efluente em termos de SST, com valor médio de 39,8 mg/L, na mesma faixa observada no reator UASB (41,6 mg/L). Foi observada menor concentração de biomassa no reator RAH (distribuição vertical) comparativamente ao reator UASB segundo os perfis verticais de lodo, entretanto, este fato não comprometeu a sua eficiência de remoção de matéria orgânica e dos sólidos suspensos. A retirada do lodo de excesso dos sistemas piloto foi baseada na relação STV/ST para estimar a fração de biomassa, a freqüência do descarte foi de 1 vez por mês retirando o equivalente aos 10% do volume de lodo das tomadas que apresentaram uma fração de STV menor que 50%. É viável a implementação da turbidez como parâmetro de detenção de perdida de lodo no efluente dos reatores anaeróbios devido a que a turbidez e os SST apresentaram uma relação direta o que ajudaria a simplificar mecanismos de controle operacional para a toma de decisões nas estações de tratamento, sendo que a turbidez é um parâmetro de leitura rápida “in situ” e poderia advertir do excesso de lodo ao interior do reator. Foram empregados diferentes métodos titrimétricos para a determinação dos AGVs no efluente do RAH e UASB. Após análise dos resultados, recomenda-se o uso do método de KAPP e RIPLEY para a determinação dos AGVs pela simplicidade metodológica e pela rapidez na obtenção do resultado. / This study aimed to evaluate the performance and operational stability of a new configuration of a hybrid anaerobic reactor (RAH) combining an anaerobic filter downflow followed by a sludge blanket chamber upflow compared to UASB in same operating conditions applied to sewage treatment. The evaluation of organic matter removal and removal efficiency of suspended solids in the pilot reactor was by testing COD, BOD, total suspended solids (TSS) and volatile suspended solids (VSS). The RAH and UASB reactors were operated for a period of 240 days in the first phase and 150 days in phase 2 with the inlet flow of 1,6 m3/h and 11,8h TDH. The average TDH RAH in the inlet chamber was 2.7h and 9,1h in ascending chamber sludge blanket. Pilot reactors showed treatment capacity to support organic shock loads due to the variability of raw sewage. The organic matter removal efficiency in terms of COD was 66% and 59% for the UASB and RAH, the TSS removal efficiency reached values of 65% and 63% respectively, by the way, the UASB presenting performance values higher operational in almost all parameters of the monitoring anaerobic digestion processes mean values of the parameters COD, BOD5, TSS and VSS were not statistically significant differences. The pH for the pilot systems was in the ideal range for the development of anaerobic microorganisms (6,5 to 7,5) and alkalinity and Volatile Fatty Acids (VFA) demonstrated stability of reactors corroborated by the pH stability within each system. The upflow velocity in the sludge blanket chamber (0,45 m/h) caused no adverse effect on effluent quality in terms of TSS, with an average of 39,8 mg/L, in the same range observed in UASB (41,6 mg/L). It was observed lower concentration of biomass in the reactor RAH (vertical distribution) compared to UASB second vertical sludge profiles, however, this fact did not compromise its removal efficiency of organic matter and suspended solids. The withdrawal of the pilot systems excess sludge was based on TSV/TS ratio to estimate the biomass fraction, the frequency of disposal was 1 once a month by removing the equivalent of 10% of the outlets sludge volume that had a fraction of TSV less than 50%. The implementation of turbidity as sludge lost detention parameter is viable in the effluent of the anaerobic reactors due to turbidity and TSS showed a direct relationship which would help simplify operational control mechanisms for decision making in treatment plants, wherein the turbidity is a quick read parameter "in situ" and could warn of excess sludge inside the reactor. Different titrimetric methods were employed for the determination of VFA and the effluent from the UASB and RAH. After analyzing the results, we recommend the use of KAPP and RIPLEY method for the determination of VFA by methodological simplicity and speed in obtaining results.
16

Análise comparativa do desempenho de reator anaeróbio híbrido e reator de manto de lodo de fluxo ascendente (UASB) aplicados ao tratamento de esgoto sanitário

Hoyos, Nestor Leonel Muñoz January 2016 (has links)
O presente trabalho teve como objetivo principal avaliar a performance e a estabilidade operacional de uma nova configuração de um reator anaeróbio híbrido (RAH) que combina um filtro anaeróbio de fluxo descendente seguido de uma câmara de manta de lodo de fluxo ascendente comparativamente ao reator UASB nas mesmas condições operacionais aplicados ao tratamento de esgoto sanitário. A avaliação da eficiência de remoção de remoção da matéria orgânica e dos sólidos suspensos nos reatores piloto foi por meio de testes da DQO, DBO, sólidos em suspensão totais (SST) e dos sólidos em suspensão voláteis (SSV).Os reatores UASB e RAH foram operados por um período de 240 dias na fase 1 e 150 dias na fase 2 com vazão afluente de 1,6 m3/h e TDH de 11,8 h. O TDH médio na câmara de entrada do RAH foi de 2,7h e de 9,1h na câmara ascendente de manto de lodo. Os reatores piloto apresentaram capacidade de tratamento para suportar os choques de carga orgânica devido à variabilidade do esgoto bruto. A eficiência de remoção de matéria orgânica em termos de DQO foi de 66% e 59% para o UASB e RAH, a eficiência de remoção de SST atingiu valores de 65% e 63% respectivamente, aliás, o reator UASB apresentando valores superiores de desempenho operacional em quase todos os parâmetros de monitoramento dos processos de digestão anaeróbia os valores médios dos parâmetros DQO, DBO5, SST e SSV não tiveram diferenças estatisticamente significativas. O pH para os sistemas piloto esteve na faixa ideal para o desenvolvimento dos microorganismos anaeróbios (6,5 a 7,5) e a alcalinidade e os AGVs demonstraram estabilidade dos reatores, corroborados pela estabilidade do pH no interior de cada sistema. A velocidade ascensional na câmara de manta de lodo (0,45 m/h) não causou efeito adverso na qualidade do efluente em termos de SST, com valor médio de 39,8 mg/L, na mesma faixa observada no reator UASB (41,6 mg/L). Foi observada menor concentração de biomassa no reator RAH (distribuição vertical) comparativamente ao reator UASB segundo os perfis verticais de lodo, entretanto, este fato não comprometeu a sua eficiência de remoção de matéria orgânica e dos sólidos suspensos. A retirada do lodo de excesso dos sistemas piloto foi baseada na relação STV/ST para estimar a fração de biomassa, a freqüência do descarte foi de 1 vez por mês retirando o equivalente aos 10% do volume de lodo das tomadas que apresentaram uma fração de STV menor que 50%. É viável a implementação da turbidez como parâmetro de detenção de perdida de lodo no efluente dos reatores anaeróbios devido a que a turbidez e os SST apresentaram uma relação direta o que ajudaria a simplificar mecanismos de controle operacional para a toma de decisões nas estações de tratamento, sendo que a turbidez é um parâmetro de leitura rápida “in situ” e poderia advertir do excesso de lodo ao interior do reator. Foram empregados diferentes métodos titrimétricos para a determinação dos AGVs no efluente do RAH e UASB. Após análise dos resultados, recomenda-se o uso do método de KAPP e RIPLEY para a determinação dos AGVs pela simplicidade metodológica e pela rapidez na obtenção do resultado. / This study aimed to evaluate the performance and operational stability of a new configuration of a hybrid anaerobic reactor (RAH) combining an anaerobic filter downflow followed by a sludge blanket chamber upflow compared to UASB in same operating conditions applied to sewage treatment. The evaluation of organic matter removal and removal efficiency of suspended solids in the pilot reactor was by testing COD, BOD, total suspended solids (TSS) and volatile suspended solids (VSS). The RAH and UASB reactors were operated for a period of 240 days in the first phase and 150 days in phase 2 with the inlet flow of 1,6 m3/h and 11,8h TDH. The average TDH RAH in the inlet chamber was 2.7h and 9,1h in ascending chamber sludge blanket. Pilot reactors showed treatment capacity to support organic shock loads due to the variability of raw sewage. The organic matter removal efficiency in terms of COD was 66% and 59% for the UASB and RAH, the TSS removal efficiency reached values of 65% and 63% respectively, by the way, the UASB presenting performance values higher operational in almost all parameters of the monitoring anaerobic digestion processes mean values of the parameters COD, BOD5, TSS and VSS were not statistically significant differences. The pH for the pilot systems was in the ideal range for the development of anaerobic microorganisms (6,5 to 7,5) and alkalinity and Volatile Fatty Acids (VFA) demonstrated stability of reactors corroborated by the pH stability within each system. The upflow velocity in the sludge blanket chamber (0,45 m/h) caused no adverse effect on effluent quality in terms of TSS, with an average of 39,8 mg/L, in the same range observed in UASB (41,6 mg/L). It was observed lower concentration of biomass in the reactor RAH (vertical distribution) compared to UASB second vertical sludge profiles, however, this fact did not compromise its removal efficiency of organic matter and suspended solids. The withdrawal of the pilot systems excess sludge was based on TSV/TS ratio to estimate the biomass fraction, the frequency of disposal was 1 once a month by removing the equivalent of 10% of the outlets sludge volume that had a fraction of TSV less than 50%. The implementation of turbidity as sludge lost detention parameter is viable in the effluent of the anaerobic reactors due to turbidity and TSS showed a direct relationship which would help simplify operational control mechanisms for decision making in treatment plants, wherein the turbidity is a quick read parameter "in situ" and could warn of excess sludge inside the reactor. Different titrimetric methods were employed for the determination of VFA and the effluent from the UASB and RAH. After analyzing the results, we recommend the use of KAPP and RIPLEY method for the determination of VFA by methodological simplicity and speed in obtaining results.
17

Reator anaeróbio híbrido para tratamento de esgoto sanitário / Hybrid anaerobic reactor for domestic sewage treatment

Fernando Hermes Passig 11 March 2005 (has links)
Este trabalho de investigação refere-se ao uso do reator anaeróbio híbrido para tratamento de esgoto sanitário, com configuração baseada no reator anaeróbio de manta de lodo (UASB) com inclusão de: meio suporte sobre as calhas de coleta de gás (denominado reator anaeróbio híbrido - UAHB) e, também, meio suporte na zona de reação (denominado reator anaeróbio híbrido modificado - UAHBmod). Para o desenvolvimento desta pesquisa, no Campus I da USP de São Carlos-SP foram construídos dois reatores experimentais de 18,8 m3 cada: um reator UASB, com função de controle, e um reator UAHB. Primeiramente os reatores foram operados por período de 200 dias, com tempo de detenção hidráulica (TDH) de 6 h. Após serem inoculados, com 80 dias de operação, os reatores atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média de DQO, de 84% e 85% e de DBO de 87% e 91%, respectivamente para o UASB e o UAHB. Após esse período, os reatores foram submetidos a aumento da velocidade ascensional (Vasc) (mediante recirculação do efluente) de 0,78 m.h-1; 1,17 m.h-1; 1,56 m.h-1 e de 1,96 m.h-1. O UAHB mostrou ser menos susceptível ao aumento da Vasc do que o UASB. Além da análise da operação dos reatores, foram realizados os ensaios hidrodinâmicos e avaliada a estrutura da comunidade microbiana, por microscopia ótica, epifluorescência e pela técnica do DGGE. Após esse período preliminar, os reatores UAHB e UAHBmod, operados com TDH de 6h e Vasc de 0,78 m.h-1, atingiram o estado de equilíbrio dinâmico aparente, com geração de alcalinidade, baixa concentração de ácidos voláteis e eficiência de remoção média da matéria orgânica, de 71% e 76% em DQO, e de 72% e 87% em DBO, respectivamente para o UAHB e UAHBmod. Após este período, o reator UAHBmod, submetido a Vasc de 1,56 m.h-1, promoveu remoção de 74% de DQO, e de 87% de DBO. / This research refers to the use of a hybrid anaerobic reactor (UAHB) for domestic wastewater treatment. The configuration of this reactor is based on a sludge bed anaerobic reactor (UASB); in the first instance, a media support above the gas collection apparatus (also known as hybrid anaerobic reactor) was provided and later, a media support on the reaction zone (also known as hybrid modified anaerobic reactor - UAHBmod) was provided. Two reactors, with a volume of 18.8 m3, each, were built for this research at Campus I, USP in São Carlos - SP-Brazil. One UASB reactor acted as a control, and the other as a UAHB reactor. In the preliminary essays, the reactors were operated with 6h of hydraulic detention time (HDT) for 200 days. After inoculation, the reactors attained the apparent dynamic equilibrium state after 80 days of operation, with alkalinity generation, low volatile acids concentration and mean organic matter removal of 84% and 85% in terms of COD, and 87% and 91% in terms of BOD, for UASB and UAHB reactors, respectively. After this period, the reactors were submitted to an increasing in up velocity (Vup) of 0.78 m.h-1; 1.17 m.h-1; 1.56 m.h-1 and 1.96 m.h-1. The UAHB reactor showed lesser susceptibility for Vup increase than the UASB reactor. Hydrodynamic tests were also done on the reactors, in addition to routine operational analysis. The structure of the microbial community was evaluated by optical and epifluorescence microscopy, and the DGGE technique. After this step, the UAHB and the UAHBmod reactors were operated out 6h of HDT and Vup of 0.78 m.h-1. The reactors attained the apparent dynamic equilibrium state with alkalinity generation, low volatile acids concentration and mean organic matter removal of 71% and 76% in terms of COD, and 72% and 87% in terms of BOD for the UASB and UAHBmod reactors, respectively. After this period, the UAHBmod reactor was subjected to a Vup of 1.56 m.h-1 and achieved removal efficiencies of 74% COD and 87% BOD.
18

Produção de biogás em reator anaeróbio de alta taxa alimentado com a fração líquida de esterco bovino peneirado / Biogas production in anaerobic high-rate reactor fed with the liquid fraction of cattle manure

Adriano Gasparini Vidal 19 June 2015 (has links)
O objetivo desse trabalho foi o de avaliar o desempenho de um reator anaeróbio híbrido de alta taxa (AHHR), contendo biomassa imobilizada em leito ordenado, alimentado com a fração líquida de esterco bovino, na produção de biogás. No estudo, foi utilizado um reator anaeróbio de fluxo ascendente de 12,4 L de volume total (9,2 L de volume útil) com leito ordenado composto por hastes de espuma de poliuretano (PU). O leito ordenado utilizado possuía 32 hastes de espuma de 1,25 cm2 de seção com 50,0 cm de comprimento, posicionadas verticalmente no interior do reator. A alimentação do reator e a recirculação foram realizadas por meio de bombas dosadoras de diafragma. O reator operou na faixa mesofílica de temperatura (de 20 a 40 &#176C) sem a utilização de mecanismos de controle de temperatura. Foram testadas 7 condições operacionais diferentes, variando o tempo de detenção hidráulica (TDH), carga orgânica volumétrica (COV) aplicada e a utilização de recirculação interna. Para cada fase operacional, foram avaliadas a remoção de matéria orgânica e a produção de biogás. O sistema apresentou elevada remoção de matéria orgânica operando com TDH de 3 e 1d, respectivamente, com valores médios de remoção de DQO de 79 &#37 e 71 &#37. O biogás produzido pelo reator apresentou concentração de metano de 57,6 ± 0,5 &#37 e não foi detectada a presença de sulfeto. A maior produção média de metano foi de 1,676 L CH4/d, obtida com COV de 20 kg DQO/m3.d e TDH de 1d, enquanto a maior produção relativa de metano foi de 0,023 L CH4./ g SV.d, obtida com COV de 5 kg DQO/m3.d e TDH de 1d e recirculação. A relação entre alcalinidade intermediária e parcial teve valor médio de 0,32, oscilando na maior parte do tempo entre 0,27 e 0,33, indicando a estabilidade do processo de digestão anaeróbia. Os resultados obtidos indicaram o potencial satisfatório do AHHR para a remoção de matéria orgânica e produção de biogás a partir da fração líquida do esterco bovino nas condições operacionais testadas na pesquisa. / This study aimed at evaluating the biogas production for electricity generation performance of an anaerobic high-rate hybrid reactor (AHHR), containing immobilized biomass in structured-bed, fed with the liquid fraction of cattle manure. In this study, it was used an upflow 12,4 L anaerobic reactor (9,2 L working volume) with structuredbed composed by 32 PU foam stripes (1,25 cm2 cross section and 500 mm length) vertically fixed inside the reactor. The reactor feeding and internal recirculation was made by diaphragm metering pumps. The reactor operated at mesophilic temperature (20 - 40 &#176C) without temperature control system. Different operating conditions were tested (7 stages), changing hydraulic retention time (HRT), organic loading rate (OLR) and recirculation use. COD removal and biogas production were evaluated for each operational condition. The system resulted in high COD removal operating with HRT of 3 and 1d, respectively, with average COD removal of 79 &#37 and 71 &#37. Produced biogas had 57,6 ± 0,5 &#37 of methane and no sulfide. The highest average volumetric methane production was 1,676 L CH4, obtained with OLR of 20 kg COD/m3.d and 1d HRT, and the highest methane yield was 0,023 L CH4/ g VS obtained with OLR of 5 kg COD/m3.d, 1d HRT and recirculation. The intermediate and partial alkalinity relation had an average value of 0,32, varying most of the time between 0,27 and 0,33, indicating the anaerobic digestion process stability. The results indicated the decent COD removal and biogas production using the AHHR fed with the liquid fraction of cattle manure at the operation conditions used in this study.
19

Avaliação da performance de um reator anaeróbio híbrido (RAH) e da atividade das populações de microrganismos anaeróbios na ausência e na presença de Pentaclorofenol (PCP) / not available

Martha de Almeida Prado Montenegro 01 June 2001 (has links)
O presente trabalho foi desenvolvido com o objetivo de verificar a eficiência de um reator anaeróbio híbrido (RAH) alimentado com uma mistura de ácidos orgânicos acético, propiônico, butírico, e láctico, bem como do álcool metanol, perfazendo uma DQO de 6,88 g/L, e avaliar nessas condições, a degradação do pentaclorofenol (PCP) na faixa de 2,0 a 21,0 mg/L. O RAH apresentou adequada performance na ausência de PCP, tendo sido inoculado com um lodo com AME cerca de 0,57 g DQO-CH4/g SV.d. Durante os 21 meses de operação do RAH na ausência de PCP verificou-se uma remoção média de DQO de 93% produção média de metano de 84%. Através de testes de toxicidade realizadas em batelada com o lodo granulado do RAH, antes da adição de PCP no reator, calculou-se o IC50, cujos valores foram 10, 12 e 13,69 mg/L. Na presença de PCP na faixa de 2,0 a 2,1 mg/L, o RAH apresentou remoção média de DQO de 96,7%, produção média de metano de 85,5% e remoção dos ácidos voláteis próxima a 74% do acético, 93% do butírico e 64% do propiônico. Individualmente, na presença da maior concentração de PCP adicionada, ocorreu decréscimo na remoção dos ácidos voláteis, principalmente do ácido propiônico e na taxa de conversão DQO/biogás. O PCP foi removido do sistema na ordem de 99% pela ação do lodo granulado com predominância do grupo das Archaea metanogênicas, verificada por exames microscópicos e hibridação \"in situ\". Valores da ordem de grandeza microbiana para os microrganismos metanogênicos nos períodos anteriores e posteriores a adição de PCP permaneceram na faixa de 105 e 106 céls./mL, quando cultivados em metanol e lactato mais sulfato, respectivamente. Os resultados sugerem que as Archaea metanogênicas podem estar envolvidas na degradação do PCP. A velocidade de remoção do organoclorado foi igual a 1,07 mg PCP/g SV.d quando a maior concentração de PCP foi estudada (21,0 mg/L). / The present research aimed to verify the efficiency of an Anaerobic Hybrid Reactor (AHR) supplied with a mixture of fatty acids, acetic, propionic, butyric and lactic and methanol as well. The total amount of COD was 6.88 g/L. The performance of the reactor was remarkably stable and efficient during PCP additions at range from 2.0 to 21.0 mg/L. The AHR showed a great performance in the PCP absence, inoculated with sludge with an specific methanogenic (SMA) activity of 0,057 g.COD-CH4/g. VS.d. During the 21 months of operation without PCP, the reduction of COD was around 93% and methane was up to 84% in the biogas. Before PCP addiction, two toxicity batch tests conducted with the granular sludge presented IC50 values around 10.12 mg/L and 13.69 mg/L. In the presence of PCP, at the range of 2.0 to 21.0 mg/L, the efficiency of volatile fatty acids breakdown was 93%, 64% and 74% respectively for butyric, propionic and acetic acids. Individually, at the presence of the higher PCP concentration studied, a decrease in the conversion of COD to biogas and organic acids removal occurred, mainly with propionic acid. PCP total removal of more than 99% was reached by granular sludge activities formed by the total time of reactor operation with a prevalence of methanogenic Archaea, verified under direct microscopy exams and in situ hybridization. Methanogenic cells predominance was noticed with 105 to 106 cells/mL during enumeration on methanol and lactate plus sulfate culture media, respectively. The results suggest that methanogenic Archaea can be involved in PCP degradation. The organochlorine removal rate was 1.07 mg PCP.g-1 VS.d-1 during the highest PCP (21.0 mg/L) concentration addition.

Page generated in 0.4289 seconds