• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 833
  • 520
  • 82
  • 45
  • 31
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 17
  • 13
  • 12
  • 11
  • Tagged with
  • 1882
  • 853
  • 745
  • 493
  • 257
  • 239
  • 196
  • 185
  • 175
  • 148
  • 141
  • 134
  • 133
  • 128
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Development of a novel spinal implant for progressive scoliosis correction

Yeung, Wai-kwok, Kelvin. January 2004 (has links)
Thesis (Ph. D.)--University of Hong Kong, 2005. / Title proper from title frame. Also available in printed format.
112

A comparison of repeated uniaxial tension and compression on bone-like cells over fourteen days

Schultz, Nathaniel David, January 2008 (has links)
Thesis (M.S.)--Mississippi State University. Department of Agricultural and Biological Engineering. / Title from title screen. Includes bibliographical references.
113

Identification des déterminants bio-psychosociaux exprimés par le patient complètement édenté en implantologie dentaire /

Bernier, Jacques. January 2004 (has links)
Thèse (M.Sc.)--Université Laval, 2004. / Bibliogr.: f. 105-113. Publ. aussi en version électronique.
114

On the bone tissue response to titanium implants

Sennerby, Lars. January 1991 (has links)
Thesis (doctoral)--University of Göteborg, 1991. / Extra t.p. with thesis statement inserted. Includes bibliographical references.
115

Prosthetic vein valve delivery and in vitro evaluation /

Farrell, Laura-Lee Amelia Catherine. January 2007 (has links)
Thesis (M. S.)--Bioengineering, Georgia Institute of Technology, 2007. / Dr. Elliot Chaikof, Committee Member ; Dr. Ross Milner, Committee Member ; Dr. David Ku, Committee Chair.
116

Rapid thermal annealing of donor implants in gallium arsenide

Bensalem, Rachid January 1986 (has links)
Rapid thermal annealing was used to produce n⁺-surface layers in tin- and selenium-implanted GaAs. Hall effect and differential Van der Pauw measurements were performed and peak electron carrier concentrations of about 9 x 10¹⁸ cm⁻³ with corresponding sheet resistivities as low as 28 Ω/□, were achieved for high-dose, room-temperature Sn and Se implants. To realise this, development of new encapsulants and improvements to existing annealing methods were made. A novel method of depositing evaporated AIN for protecting the GaAs surface has been developed. This consists of the evaporation of Al in the presence of pure ammonia gas or an aqueous NH3/N5 gas mixture. The evaporated AlN layers were characterised using RBS and RHEED techniques and found to consist mainly of Al, N and 0 (as contaminant). These layers were used to successfully encapsulate GaAs at temperatures of up to 1100°C which is well above 950°C, the characteristic maximum useful temperature achieved using the existing CVD Si₃N₄. A double-layer encapsulant, consisting of ≈ 300 Å CVD Si₃N₄ plus 600 Å evaporated AlN was also developed and found to withstand even higher temperatures (≈1150°C) and to provide more reliable and reproducible results than either AlN or Si₃N₄ when used singly.
117

Plataforma regular versus switching: estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e interno

Freitas Júnior, Amilcar Chagas [UNESP] 30 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-30Bitstream added on 2014-06-13T20:25:50Z : No. of bitstreams: 1 freitasjunior_ac_dr_araca.pdf: 626707 bytes, checksum: 01bcfeff181d77eb6eaa682b52483519 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)... / Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below)
118

Estudo morfométrico da estrutura óssea crâniofacial visando a reabilitação com prótese facial retida em implantes extrabucais / Morphometric study of craniofacial bones for rehabilitation with facial prostheses retained by extrabucal implants

Olate Morales, Sergio Adrian 16 August 2018 (has links)
Orientador: José Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T04:25:57Z (GMT). No. of bitstreams: 1 OlateMorales_SergioAdrian_D.pdf: 2241387 bytes, checksum: f35c455160e70ece3b0c4ef20a1abce8 (MD5) Previous issue date: 2010 / Resumo: Os implantes craniofaciais têm sido empregadas para obter retenção e suporte de estruturas protéticas faciais sendo útil em pacientes com seqüelas pelo tratamento do câncer, tumores, trauma ou malformações. O objetivo deste estudo descritivo foi estabelecer a espessura óssea de diferentes regiões do complexo crâniomaxilofacial para definir os melhores locais de instalação de implantes craniofaciais. Em 40 crânios humanos (31 masculinos e 9 femininos), com uma idade de entre 20 e 60 anos, provenientes do Laboratório de Anatomia da FOPUNICAMP foram realizadas tomografias computadorizadas volumétricas cone beam com o sistema I-CAT VISION na área de Radiologia Odontológica da FOPUNICAMP; posteriormente as imagens foram analisadas no software InVesalius 3.0 por dois pesquisadores para realizar a morfometria óssea. As medições foram executadas nas regiões periorbitarias, perinasais, periauriculares e na região do osso zigomático, determinando a distância entre as corticais externa e interna nos sentidos sagitais, axiais e coronais. Foram determinados os valores para cada unidade individual. Nas diferentes regiões avaliadas, na área supraorbitária os valores mínimos foram de 7,92mm ± 1,82mm e na área lateral foram de 7,54mm ± 0,98mm permitindo a instalação de implantes de 5mm ou 6mm; na área do osso zigomático os valores mínimos foram de 10,4mm ± 2,35mm permitindo a inserção de implantes de 8mm. Na área periuricular os valores obtidos na região superior foram de 2,93mm ± 0,55mm e na região inferior foram de 3,1mm ± 0,7mm; já na região do processo mastóide pode ser possível a instalação de implantes de 5mm. Na área perinasal é possível instalar implantes de 4mm ou 5mm. Conclui se que na área crâniomaxilofacial existem regiões de espessura aceitável para instalação de implantes extrabucais, sendo a região auricular superior a que apresenta maiores limitações / Abstract: Craniofacial fixation have been used for retention and support of facial prosthetic devices, useful in patients with sequelae of treatment for cancer, tumors, trauma and congenital or genetic malformations. We conducted a descriptive study to establish the bone thickness in different regions of the cranium complex to define the best locations for craniofacial implants. In 40 human skulls (31 men and 9 female), between 20 to 60 years old, from the Laboratory of Anatomy of FOPUNICAMP were performed tomography computed volumetric cone beam with the ICAT VISION in the area of Dental Radiology of FOP-UNICAMP. Subsequent images were analyzed in InVesalius 3.0 software by two researchers to perform bone morphometry. The measurement were performed in the periorbital, perinasal and periauricular region and the area of zygomatic bone, determining the distance between the internal and external cortical senses in sagittal, axial and coronal views. The values were determined for each individual unit. In the supraorbital area, the minimum values were 7.92 mm ± 1.82 mm and the lateral area were 7.54 mm ± 0.98 mm allowing the installation of 5mm or 6mm length implants, the área of the zygomatic bone minimum values were 10 , 4 mm ± 2.35 mm allowing the insertion of implants of 8 mm. In the periauricular areas the values in the upper region were 2.93mm ± 0.55mm and lower were 3.1mm ± 0.7mm; the region of the mastoid process allowed the installation of 5mm implants. In the perinasal region 4mm or 5mm length implants could be installed. We conclude that in the craniummaxillofacial area there are regions for acceptable thickness for extrabucal implant installation being the superior temporal bone area that show has major limitations / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
119

Analise histologica e histomorfometrica do reparo osseo perimplantar em cães submetidos a instalação de implantes endosseos com um modelo de carga precoce em dois diferentes desenhos de implantes / Histological and histomorphometric analysis of perimplant osseous repair in dogs submitted to endosseous implant installation with early load model in two different implant design

Olate Morales, Sergio Adrian 02 December 2009 (has links)
Orientador: Jose Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:32:19Z (GMT). No. of bitstreams: 1 OlateMorales_SergioAdrian_M.pdf: 2518502 bytes, checksum: 379ec7fb825eca639d7e7c3aa4e052a8 (MD5) Previous issue date: 2009 / Resumo: Diferentes protocolos para a reabilitação com prótese implanto assistida têm sido reportados. Deles, é possível que a carga imediata em implantes unitários sejam um dos mais controversos. O objetivo deste estudo foi estabelecer quantitativamente as características de reparo ósseo em implantes submetidos a um modelo de carga precoce. Foi desenvolvido um modelo experimental em cães para a avaliação de dois protocolos de instalação de implantes dentais com dois desenhos diferentes. Foi realizada a exodontia dos pré-molares bilaterais mandibulares dos animais e após de três meses foi realizada a instalação de dois implantes bilateriais. No implante mesial foi realizada a instalação do parafuso cicatrizador de 7 mm (modelo de carga imediata unitária sem contato oclusal) e no implante distal foi instalado o parafuso cobertor (técnica de implante submerso). Cada hemimandíbula recebeu um implante cilíndrico (Neodent Titamax CM®) e um implante cônico (Conexão Conect Ar®) com seu parafuso cicatrizador. Inicialmente os primariamente foram avaliados com microscopia eletrônica de varredura. Os sacrifícios dos animais foram após de três e seis semanas. Os blocos foram descalcificados e processados para análise com histológica descritiva e histomorfométrica. Foi aplicado o teste estatístico t teste para variáveis independentes com nível de significância de 5%. De forma geral, os implantes apresentaram maior formação óssea no nível cervical e menor no nível apical. Os resultados demonstram também maior formação óssea em implantes com o modelo de carga precoce que em aqueles sem carga, com ausência de diferença estatística. Por outra parte, os implantes cônicos apresentaram maior formação óssea que os cilíndricos, também sem significância estatística. Concluiu-se que os implantes com instalação do parafuso cicatrizador, como modelo de restauração imediata sem contato oclusal, apresenta maior quantidade óssea nos vales quando comparados aos implantes não submetidos a carga / Abstract: Several treatment types using prosthesis over implants have been reported, being the singles immediate loading therapy with more controversy. The meaning of the present study is established the characteristics of bone repair in dental implant submitted to immediate loading. It was performed a experimental model using dogs to value two different installations protocols of dental implants. It was done the extraction of the bilateral premolars of the jaw, installing the dental implants after 3 months of healing. The anterior implant was submitted to healing screw install of 7 mm (unitary immediate load model without oclusal contact) and the posterior ones were covered with cove screrw (immerse implant technique). Each hemi-jaw presented one cylindrical (Neodent Titamax CM®) or conical (Conexão Conect Ar®) with with anterior or posterior position, that was evaluated with scanning electron microscopy. The sacrifices were performed on three and six months. The specimens were decalcified and processed to begging its histological evaluation using descriptive and histomorphometric analyses. The statistical test T test was performed using significance index of 5%. In general, dental implants showed more bone formation on cervical region and less on apical area. The results demonstrated more bone formation on the immediate loading types, with no statistical significance. The conical ones presented more bone formation that cylindrical, but without statistical significance. This way it is possible to conclude that implants with immediate installation of healing screw, how immediately load model without oclusal contact (immediately restauration), have more osseous presence when compared to non load implant / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
120

Avaliação do comportamento mecanico de proteses fixas implantossuportadas por meio da tecnica de extensometria eletrica / Evaluation of mechanic behavior of fixed prosthesis implantsupported by means of electric extensometry technic

Prado, Devanir Silva Vieira, 1951- 13 August 2018 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:38:34Z (GMT). No. of bitstreams: 1 Prado_DevanirSilvaVieira_M.pdf: 895028 bytes, checksum: fe09fdf9bad8a966f0302b161600791e (MD5) Previous issue date: 2009 / Resumo: Muitas vezes, as tensões são causadas por alterações nas adaptações das estruturas protéticas ao implante, além dos desajustes marginais entre as fixações e as reabilitações protéticas. Este trabalho tem como objetivo, avaliar a distribuição de compressão e tração dos pilares protéticos e infra-estrutura metálica fundida em liga de cobalto-cromo, pela técnica de monobloco, simulando uma prótese fixa implantossuportadas sobre 06 implantes com distância de 10 mm entre implantes e com extremo livre (cantilever) bilateral com extensão de 20 mm, colocados através da curvatura da linha oclusal mandibular. Em cada pilar foram colados quatro extensômetros e um em cada cantilever, após o apertamento de todos pilares e a infra-estrutura aos implantes, foi submetido a um ensaio mecânico com cargas compressivas verticais de 150 N, analisando quantitativamente os resultados bem precisos através da extensometria. Os resultados foram obtidos usando os maiores valores de carga axial registrados em cada ponto de força aplicado, registrando deformação para infra-estrutura, pilares e os cantilevers. Com aplicação de carga nos pontos entre os pilares, foi obtido nos pilares mais próximos a aplicação da carga um maior grau de compressão e nos pilares mais distantes, em menor grau de acordo com a distribuição de carga deformação por compressão e ou/ tração. Com aplicação de carga vertical máxima no cantilever, o pilar adjacente foi o mais solicitado por compressão, independente do ponto de aplicação da carga e o último pilar do lado oposto em menor intensidade, também solicitado por compressão, formando um eixo de rotação, no qual os componentes anteriores foram solicitados em regime de tração (alavanca). O carregamento mecânico registrou deformação para a infraestrutura, pilares e cantilever. / Abstract: Frequently, stresses are caused by changes in adaptations of prosthetic structures to the implant besides marginal disajustment between prosthetic fixing and rehabilitations. This study aims to evaluate the distribution of compression and traction of the prosthetic sustainers and the methalic framework melted in cromocobalt alloy, through the monoblock technic simulating a fixed prosthesis implantsupported on 06 implants at the distance of 10mm between each other and with bilateral cantilever extending to 20mm, placed along the mandibular oclusal line curvature, with the extensometry technic. In each abutment there have been placed four strain guages and one in each cantilever, in configuration "Wheatstone Bridge", after all components having been fixed to the framework, it was submitted to a mechanic essay with vertical pressing charges of 150Ncm, checking quantitatively the accurate result through extensometry. Results have been obtained by using the greatest values of axial charge registered in each place of applied force,. On nearest pillars to the charge, It has been obtained a greater degree of compression (fulcrum), what corresponds to the amount of oclusal force applied to the equalizing stress force. And, therefore, the most distant pillars will assimilate a negative deformation ( compression) or a positive deformation (traction, seesaw), proportional to the lever arm. / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.0352 seconds