• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise cinemática da marcha de amputados transtibiais: comparação dos encaixes KBM e a vácuo

Ferreira, Alana Elisabeth Kuntze 26 August 2014 (has links)
Introdução: A amputação transtibial é uma das amputações de membros inferiores mais frequentemente realizada. Objetivo: Este trabalho teve por objetivo comparar, através da análise tridimensional da marcha, as alterações de marcha de pacientes com amputação transtibial, previamente treinados, que utilizavam próteses com encaixe Kondylen Bettung Münster (KBM) e a vácuo. Metodologia: Foram avaliados voluntários com amputação transtibial que utilizavam encaixe KBM ou a vácuo disponibilizados pelos Sistema Único de Saúde (SUS). A amostra final foi de 12 participantes no grupo “KBM” e 5 no grupo “vácuo”. Todos eles passaram por um exame físico, que constou de goniometria, teste de força muscular e coleta de dados antropométricos. Eles também realizaram análise tridimensional (3D) da marcha. Para tal, eles foram paramentados com marcadores reflexivos em pontos anatômicos e os correspondentes da prótese, de acordo com o modelo Helen Hayes e caminharam por uma pista de 10 metros com uma velocidade auto selecionada. O sistema de captura consistiu em 6 câmeras Hawk e software Cortex versão 1.1.4.368, de captura e edição das caminhadas, ambos da Motion Analysis Corporation. A comparação entre os dois grupos foi realizada através da Pontuação do Perfil da Marcha (GPS), das Pontuações das Variáveis da Marcha (GVS) e dos parâmetros de tempo e espaço da marcha. Além disso, foi testada a correlação entre a GPS e as GVS e entre a GPS e os parâmetros de tempo e espaço da marcha. Resultados: Os dois grupos obtiveram velocidade da marcha significativamente menores, período de apoio significativamente maior e o tempo de apoio simples menor que o normal. Nos dois grupos ainda, os valores de GPS e GVS foram maiores que o normal, porém o “KBM” apresentou maiores desvios que o “vácuo”. Os maiores desvios do grupo do encaixe KBM foram nas GVS flexão/extensão dos quadris, flexão/extensão dos joelhos e dorsi/plantiflexão do tornozelo MIP, podendo assim caracterizar este como o padrão de desvio do Perfil de Análise do Movimento (MAP) deste grupo. O grupo “vácuo” teve os principais desvios nas GVS dorsi/plantiflexão dos tornozelos, flexão/extensão do joelho MIP e rotação pélvica, sendo este o padrão de desvio do MAP deste grupo. Encontraram-se, portanto, padrões diferentes de desvio nos dois grupos. Os dois grupos apresentaram desvios no MICL, os quais representam as compensações realizadas neste membro para possibilitar uma marcha mais funcional com a prótese. Os participantes que utilizaram o encaixe a vácuo apresentaram marcha mais simétrica que os participantes que utilizavam encaixe KBM. O grupo que utilizava o encaixe a vácuo obteve menores valores de GPS e de algumas GVS que o grupo “KBM”, entre elas estão a flexão/extensão do quadril MIP e MICL, flexão/extensão do joelho MIP e a flexão/extensão do joelho MICL, que foi a única diferença estatisticamente significante entre os grupos de encaixe. O mesmo grupo teve velocidade da macha maior que o grupo “KBM” e, apesar desta diferença não ter sido significativa, sugere uma maior funcionalidade da marcha com o encaixe a vácuo. Conclusão: Pode-se concluir que os indivíduos que utilizaram encaixe a vácuo apresentaram um padrão de marcha mais funcional e com menores desvios que aqueles que utilizaram encaixe KBM, quando comparados através da GPS, das GVS e dos parâmetros de tempo e espaço. / Introduction: Transtibial amputation is one of the lower limb amputations more often performed. Objective: The aim of this study was to compare, using 3D gait analysis, gait deviations of patients with transtibial amputation, previously trained, using KBM and vacum prosthetic fittings. Methodology: Transtibial amputees that used Kondylen Bettung Münster (KBM) and vacuum prosthetic fitting waived by the Sistema Único de Saúde (SUS) were evaluated. The final sample consisted of 12 participants in the "KBM" group and 5 in the "vacuum" group. They all underwent a physical examination, which consisted of goniometry, muscle strength testing and anthropometric data. They also performed three-dimensional (3D) gait analysis. For this, they were vested with reflexive markers on anatomical and prosthetic corresponding landmarkers according to the Helen Hayes and walked across a 10-m walk-way at their self-selected speed. The capture system consisted of 6 cameras Hawk and the Cortex software version 1.1.4.368 for capturing and editing the trials, both from Motion Analysis Corporation. The Gait Profile Scores (GPS), Gait Variable Score (GVS) and temporal-spatial parameters performed the comparison between the two groups. In addition, we tested the correlation between GPS and GVS and between GPS and temporal-spatial parameters. Results: The two groups had significantly lower gait speed, significantly longer period of support and shorter time of single support than normal. In both groups, GPS and GVS values were higher than normal, but the "KBM" showed greater deviations than the "vacuum". The largest deviations from the KBM group was in the GVS hips flexion / extension, knees flexion / extension and ankle dorsi / plantarflexion MIP and can thus characterize this as the deviation pattern of the Movement Analysis Profile (MAP) for this group. The "vacuum" group had major deviations of the GVS ankles dorsi / platarflexion, knee flexion / extension MIP and pelvic rotation, the deviation pattern of MAP in this group. There were, therefore, different deviation patterns I the two groups. Both groups showed deviations in MICL, which represent the compensation made by this limb to enable a more functional gait with prosthesis. Participants who used vacuum prosthetic fitting showed more a symmetrical gait than participants that used KBM prosthetic fitting. The group that used vacuum prosthetic fitting had lower values of GPS and some GVS than "KBM" group; these include hips flexion / extension, MIP knee flexion / extension and MICL knee flexion / extension, which was the only statistically significant difference between the groups. The same group had greater walking speed than the "KBM" group and, although this difference was not significant, it suggests more functionality of gait with vacuum prosthetic fitting. Conclusion: It can be concluded that individuals who used the vacuum prosthetic fitting showed more functional gait pattern and smaller deviations than those that used KBM prosthetic fitting, compared by GPS, GVS and temporal-spatial parameters.
2

Fusão de modelos 3D com imagens térmicas para aplicações médicas

Krefer, Andriy Guilherme 26 June 2015 (has links)
CNPq; CAPES / A termografia permite a visualização de valores de temperatura de um corpo por meio de imagens. Na área médica, encontra aplicações em oncologia, análise de queimaduras, doenças vasculares, doenças respiratórias, doenças de pele e como forma geral de verificação da vitalidade dos tecidos. A termografia 3D consiste de uma malha 3D com uma textura térmica projetada em sua superfície, oferecendo uma visualização mais precisa dos padrões de temperatura das estruturas anatômicas. Propõe-se, por meio do presente trabalho, um sistema capaz de combinar imagens termográficas 2D com sua malha 3D correspondente e, como resultado, entregar uma imagem termográfica 3D para aplicações médicas. Para isso foram utilizadas as técnicas de Otimização por Enxame de Partículas (PSO) e de reconstrução 3D Structure from Motion (SfM). Diferentemente de outros trabalhos na literatura, a malha 3D e as imagens térmicas não precisam ser adquiridas simultaneamente, não sendo necessário um arranjo mecânico dedicado. A malha 3D pode ter origem em um scanner 3D ou em uma imagem de ressonância magnética, por exemplo. Para avaliar os resultados, um phantom, isto é, um objeto estático de avaliação, com propriedades conhecidas, foi construído. Para tal, uma técnica inédita, utilizando placas de circuito impresso foi desenvolvida. Como resultado, comparações entre a saída do método proposto e o phantom, apresentaram um erro máximo de 3,73 mm e médio de 1,41 mm, com desvio padrão de 0,74 mm, em um phantom de 100 x 150 x 103,2 mm. / Thermography is an imaging method that allows temperature visualization of various regions of an object. In medicine, it finds applications related to oncology, burn trauma, vascular, respiratory and skin diseases, and as a general tissue vitality checking tool. 3D thermography adds tridimensional information to the conventional 2D thermography. It is made from a 3D mesh wrapped by thermal texture, enabling a more precise visualization of thermal patterns of anatomical structures. We propose a system capable of combining 2D thermal images with their corresponding 3D mesh, delivering a 3D thermogram for medical applications as a result. We used Particle Swarm Optimization (PSO) for mesh alignment and Structure from Motion (SfM) for 3D reconstruction in the present method. In contrast to most research found in the literature, the 3D mesh and the thermal images do not need to be acquired simultaneously, and a mechanical support for the thermal camera and the 3D scanner is not required. The 3D mesh may be acquired, for instance, from a 3D scanner or a magnetic resonance imaging machine. In order to evaluate the results, a phantom, that is, a static assessment object of known properties has been built. For this purpose, a novel technique using printed circuit boards has been developed. As a result, comparison between the output of the method and the phantom shows a maximum error of 3.73 mm and a mean error of 1.41 mm with 0.74 mm of standard deviation in phantom of 100 x 150 x 103.2 mm. / 5000
3

Fusão de modelos 3D com imagens térmicas para aplicações médicas

Krefer, Andriy Guilherme 26 June 2015 (has links)
CNPq; CAPES / A termografia permite a visualização de valores de temperatura de um corpo por meio de imagens. Na área médica, encontra aplicações em oncologia, análise de queimaduras, doenças vasculares, doenças respiratórias, doenças de pele e como forma geral de verificação da vitalidade dos tecidos. A termografia 3D consiste de uma malha 3D com uma textura térmica projetada em sua superfície, oferecendo uma visualização mais precisa dos padrões de temperatura das estruturas anatômicas. Propõe-se, por meio do presente trabalho, um sistema capaz de combinar imagens termográficas 2D com sua malha 3D correspondente e, como resultado, entregar uma imagem termográfica 3D para aplicações médicas. Para isso foram utilizadas as técnicas de Otimização por Enxame de Partículas (PSO) e de reconstrução 3D Structure from Motion (SfM). Diferentemente de outros trabalhos na literatura, a malha 3D e as imagens térmicas não precisam ser adquiridas simultaneamente, não sendo necessário um arranjo mecânico dedicado. A malha 3D pode ter origem em um scanner 3D ou em uma imagem de ressonância magnética, por exemplo. Para avaliar os resultados, um phantom, isto é, um objeto estático de avaliação, com propriedades conhecidas, foi construído. Para tal, uma técnica inédita, utilizando placas de circuito impresso foi desenvolvida. Como resultado, comparações entre a saída do método proposto e o phantom, apresentaram um erro máximo de 3,73 mm e médio de 1,41 mm, com desvio padrão de 0,74 mm, em um phantom de 100 x 150 x 103,2 mm. / Thermography is an imaging method that allows temperature visualization of various regions of an object. In medicine, it finds applications related to oncology, burn trauma, vascular, respiratory and skin diseases, and as a general tissue vitality checking tool. 3D thermography adds tridimensional information to the conventional 2D thermography. It is made from a 3D mesh wrapped by thermal texture, enabling a more precise visualization of thermal patterns of anatomical structures. We propose a system capable of combining 2D thermal images with their corresponding 3D mesh, delivering a 3D thermogram for medical applications as a result. We used Particle Swarm Optimization (PSO) for mesh alignment and Structure from Motion (SfM) for 3D reconstruction in the present method. In contrast to most research found in the literature, the 3D mesh and the thermal images do not need to be acquired simultaneously, and a mechanical support for the thermal camera and the 3D scanner is not required. The 3D mesh may be acquired, for instance, from a 3D scanner or a magnetic resonance imaging machine. In order to evaluate the results, a phantom, that is, a static assessment object of known properties has been built. For this purpose, a novel technique using printed circuit boards has been developed. As a result, comparison between the output of the method and the phantom shows a maximum error of 3.73 mm and a mean error of 1.41 mm with 0.74 mm of standard deviation in phantom of 100 x 150 x 103.2 mm. / 5000
4

Avaliação de sistemas de digitalização 3D de baixo custo aplicados ao desenvolvimento de órteses por manufatura aditiva / Evaluation of low-cost 3D scanning systems applied to orthosis development by additive manufacturing

Rosenmann, Gabriel Chemin 26 September 2017 (has links)
CAPES : CNPq / Pessoas com paralisia cerebral apresentam grande diversidade de alterações posturais, sendo mais características as consequentes da espasticidade. Objetivando a otimização do desempenho funcional, juntamente com outros objetivos terapêuticos pode ser prescrito o uso órteses. Neste contexto a manufatura aditiva pode se apresentar como uma alternativa à fabricação de produtos personalizados de Tecnologia Assistiva, tais como as órteses. Para este fim a digitalização 3D é uma etapa importante, considerando que a geometria da anatomia do usuário será a referência para o desenvolvimento do produto em ambiente CAD 3D para posterior fabricação. No entanto os equipamentos de digitalização 3D possuem custos elevados, sendo um dos fatores que dificultam a popularização desta solução. Deste modo este trabalho visa avaliar a utilização de sistemas de baixo custo para realizar a digitalização 3D, no contexto do desenvolvimento de órteses personalizadas para punho, mão e dedos a serem fabricadas por manufatura aditiva. Foi proposto um método estruturado em três fases sendo: definição das ferramentas e sistemas a serem avaliados, definição dos parâmetros para avaliação e dos protocolos de utilização dos sistemas digitalização 3D; avaliação dos sistemas de digitalização 3D de baixo custo a partir da digitalização de uma peça padrão; e avaliação dos sistemas de digitalização 3D de baixo custo aplicados ao contexto de órteses para punho, mão e dedos. Os sistemas selecionados para a avaliação foram o Kinect 360 utilizando o programa Skanect, o sistema Kinect One com o programa 3DScan e o sistema ReMake com uma câmera Canon T3i. Os protocolos para a utilização dos sistemas de digitalização 3D de baixo custo foram: protocolo 1, com marcações visuais apenas no ambiente de digitalização; protocolo 2, com aplicação de adesivos coloridos sobre o objeto; e o protocolo 3, com a aplicação de linhas desenhadas à mão formando um xadrez sobre o objeto. Foi desenvolvida e fabricada uma peça padrão, composta por três elementos (um cone, um cilindro e um cubo seccionado). Para a avaliação dimensional foram considerados os parâmetros altura do cone, diâmetro do cilindro e medidas paralelas aos eixos X, Y e Z aferidas pela distância entre as faces opostas do cubo. Também foi realizada a análise dos desvios utilizando o programa Geomagic e uma avaliação da qualidade onde se verificou visualmente a formação dos vértices e das arestas. Para a avaliação aplicada ao contexto do desenvolvimento de órteses, foi aplicado mesmo procedimento sobre um molde da geometria do punho, mão e dedos confeccionado em atadura gessada. As digitalizações geraram 27 malhas 3D da peça padrão e 9 malhas 3D do molde. As avaliações indicaram que os sistemas Kinect 360 e Kinect One não apresentaram variação significativa entre os diferentes protocolos. Já o sistema ReMake foi o mais sensível, sendo o protocolo 3 o que gerou malhas 3D com os melhores resultados dimensionais e de qualidade em relação a todos os sistemas, com valores variando entre 0,07 mm e 0,27 mm nas análises dos desvios realizadas sobre a peça padrão. / People with cerebral palsy could have wide range of postural changes, the most characteristic are resulting from spasticity. Custom orthosis use can be prescribed in this context aiming increase functional performance and other therapeutic goals. The additive manufacturing is an alternative to the custom assistive products fabrication, such as orthoses. In this context 3D scanning is an important step, considering that the user anatomy is a geometric reference to product development in 3D CAD for further fabrication. However, the 3D scanners have high costs, one of the factors that hinder the popularization of this solution. Thus, this study aims to evaluate the use of low cost systems to perform 3D scanning in the context of custom orthoses development for wrist, hand and fingers to be fabricated by additive manufacturing. A three-phases method was proposed as follows: definition of tools and systems to be evaluated, definition of parameters for assessment, and definition of protocols for using 3D scanning systems; evaluation of low-cost 3D scanning systems using a standard piece; and evaluation of low-cost 3D scanning systems applied to context of orthosis for wrist, hand and fingers. The selected systems for the evaluation were 360 Kinect using Skanect software, Kinect One system with 3DScan software and the ReMake system with a Canon T3i camera. The low-cost 3D scanning systems used protocols were: Protocol 1, with visual markings only on the scanning environment; Protocol 2, with colored stickers application on the object; and protocol 3, with the use of hand drawn lines forming a chess pattern on the object. A standard piece was developed and manufactured, composed of three elements (a cone, a cylinder and a sectioned cube). The cone height, cylinder diameter and parallel measures to axes X, Y and Z were considered as the dimensional evaluation parameters. Also, a Deviations Analysis was performed using Geomagic software and a visual-quality evaluation that observed the formation of vertices and edges. For the evaluation on orthoses development context, the same procedure was applied on a cast of the wrist, hand and fingers. This cast was made of plaster bandages. The procedure generated 27 standard piece 3D mesh and 9 cast 3D meshes. The evaluations indicated that Kinect 360 and Kinect One systems have no significant variation between the different protocols. The ReMake system was the most sensitive, and the protocol 3 generated 3D meshes with the best dimensional and quality results among all systems. The deviations analysis performed on the standard piece indicated errors ranging between 0.07 mm and 0.27 mm for the ReMake’s 3D meshes.
5

Avaliação de sistemas de digitalização 3D de baixo custo aplicados ao desenvolvimento de órteses por manufatura aditiva / Evaluation of low-cost 3D scanning systems applied to orthosis development by additive manufacturing

Rosenmann, Gabriel Chemin 26 September 2017 (has links)
CAPES : CNPq / Pessoas com paralisia cerebral apresentam grande diversidade de alterações posturais, sendo mais características as consequentes da espasticidade. Objetivando a otimização do desempenho funcional, juntamente com outros objetivos terapêuticos pode ser prescrito o uso órteses. Neste contexto a manufatura aditiva pode se apresentar como uma alternativa à fabricação de produtos personalizados de Tecnologia Assistiva, tais como as órteses. Para este fim a digitalização 3D é uma etapa importante, considerando que a geometria da anatomia do usuário será a referência para o desenvolvimento do produto em ambiente CAD 3D para posterior fabricação. No entanto os equipamentos de digitalização 3D possuem custos elevados, sendo um dos fatores que dificultam a popularização desta solução. Deste modo este trabalho visa avaliar a utilização de sistemas de baixo custo para realizar a digitalização 3D, no contexto do desenvolvimento de órteses personalizadas para punho, mão e dedos a serem fabricadas por manufatura aditiva. Foi proposto um método estruturado em três fases sendo: definição das ferramentas e sistemas a serem avaliados, definição dos parâmetros para avaliação e dos protocolos de utilização dos sistemas digitalização 3D; avaliação dos sistemas de digitalização 3D de baixo custo a partir da digitalização de uma peça padrão; e avaliação dos sistemas de digitalização 3D de baixo custo aplicados ao contexto de órteses para punho, mão e dedos. Os sistemas selecionados para a avaliação foram o Kinect 360 utilizando o programa Skanect, o sistema Kinect One com o programa 3DScan e o sistema ReMake com uma câmera Canon T3i. Os protocolos para a utilização dos sistemas de digitalização 3D de baixo custo foram: protocolo 1, com marcações visuais apenas no ambiente de digitalização; protocolo 2, com aplicação de adesivos coloridos sobre o objeto; e o protocolo 3, com a aplicação de linhas desenhadas à mão formando um xadrez sobre o objeto. Foi desenvolvida e fabricada uma peça padrão, composta por três elementos (um cone, um cilindro e um cubo seccionado). Para a avaliação dimensional foram considerados os parâmetros altura do cone, diâmetro do cilindro e medidas paralelas aos eixos X, Y e Z aferidas pela distância entre as faces opostas do cubo. Também foi realizada a análise dos desvios utilizando o programa Geomagic e uma avaliação da qualidade onde se verificou visualmente a formação dos vértices e das arestas. Para a avaliação aplicada ao contexto do desenvolvimento de órteses, foi aplicado mesmo procedimento sobre um molde da geometria do punho, mão e dedos confeccionado em atadura gessada. As digitalizações geraram 27 malhas 3D da peça padrão e 9 malhas 3D do molde. As avaliações indicaram que os sistemas Kinect 360 e Kinect One não apresentaram variação significativa entre os diferentes protocolos. Já o sistema ReMake foi o mais sensível, sendo o protocolo 3 o que gerou malhas 3D com os melhores resultados dimensionais e de qualidade em relação a todos os sistemas, com valores variando entre 0,07 mm e 0,27 mm nas análises dos desvios realizadas sobre a peça padrão. / People with cerebral palsy could have wide range of postural changes, the most characteristic are resulting from spasticity. Custom orthosis use can be prescribed in this context aiming increase functional performance and other therapeutic goals. The additive manufacturing is an alternative to the custom assistive products fabrication, such as orthoses. In this context 3D scanning is an important step, considering that the user anatomy is a geometric reference to product development in 3D CAD for further fabrication. However, the 3D scanners have high costs, one of the factors that hinder the popularization of this solution. Thus, this study aims to evaluate the use of low cost systems to perform 3D scanning in the context of custom orthoses development for wrist, hand and fingers to be fabricated by additive manufacturing. A three-phases method was proposed as follows: definition of tools and systems to be evaluated, definition of parameters for assessment, and definition of protocols for using 3D scanning systems; evaluation of low-cost 3D scanning systems using a standard piece; and evaluation of low-cost 3D scanning systems applied to context of orthosis for wrist, hand and fingers. The selected systems for the evaluation were 360 Kinect using Skanect software, Kinect One system with 3DScan software and the ReMake system with a Canon T3i camera. The low-cost 3D scanning systems used protocols were: Protocol 1, with visual markings only on the scanning environment; Protocol 2, with colored stickers application on the object; and protocol 3, with the use of hand drawn lines forming a chess pattern on the object. A standard piece was developed and manufactured, composed of three elements (a cone, a cylinder and a sectioned cube). The cone height, cylinder diameter and parallel measures to axes X, Y and Z were considered as the dimensional evaluation parameters. Also, a Deviations Analysis was performed using Geomagic software and a visual-quality evaluation that observed the formation of vertices and edges. For the evaluation on orthoses development context, the same procedure was applied on a cast of the wrist, hand and fingers. This cast was made of plaster bandages. The procedure generated 27 standard piece 3D mesh and 9 cast 3D meshes. The evaluations indicated that Kinect 360 and Kinect One systems have no significant variation between the different protocols. The ReMake system was the most sensitive, and the protocol 3 generated 3D meshes with the best dimensional and quality results among all systems. The deviations analysis performed on the standard piece indicated errors ranging between 0.07 mm and 0.27 mm for the ReMake’s 3D meshes.

Page generated in 0.13 seconds