• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 19
  • 5
  • Tagged with
  • 62
  • 62
  • 38
  • 34
  • 18
  • 13
  • 12
  • 12
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Synthèse de réponse impulsionnelle en imagerie ultrasonore pour l'estimation vectorielle du déplacement mpulse response synthesis in ultrasound imaging for vectorial displacement estimation /

Liebgott, Hervé Delachartre, Philippe Vray, Didier. Wilhjelm, Jens E. January 2006 (has links)
Thèse doctorat : Acoustique : Villeurbanne, INSA : 2005. / Thèse rédigée en anglais. Titre provenant de l'écran-titre. Bibliogr. p. 132-135. Publications de l'auteur p. 137-138.
2

Méthodes d'estimation de vitesses des flux en imagerie ultrasonore haute fréquence application à l'étude de la microcirculation /

Aoudi, Walid Vray, Didier. January 2008 (has links)
Thèse doctorat : Acoustique. Traitement du signal et de l'image : Villeurbanne, INSA : 2008. / Titre provenant de l'écran-titre. Bibliogr. p. 132-138.
3

Estimation itérative du déplacement et de la déformation pour l'imagerie ultrasonore de l'élasticité des tissus biologiques application à l'échographie endovasculaire /

Fromageau, Jérémie Gimenez, Gérard. January 2005 (has links)
Thèse doctorat : Images et Systèmes : Villeurbanne, INSA : 2003. / Le chapitre 4 intitulé "Caractérisation du Cryogel pour l'élastographie sonore" est rédigé en anglais. Titre provenant de l'écran-titre. Bibliogr. p. 117-126. Publications de l'auteur p. 127-128.
4

Modélisation des échos pour images ultrasoniques de haute précision /

Pigeon, Luc. January 1997 (has links)
Thèse (M.Sc.)--Université Laval, 1997. / Bibliogr.: f. 69-70. Publié aussi en version électronique.
5

Segmentation dynamique en échocardiographie ultrasonore radiofréquence ynamic segmentation in ultrasound radiofrequency echocardiography /

Dydenko, Igor Friboulet, Denis. January 2005 (has links)
Thèse doctorat : Images et Systèmes : Villeurbanne, INSA : 2003. / Thèse rédigée en anglais. Résumé en français en début de chaque chapitre. Titre provenant de l'écran-titre. Bibliogr. p. 216-232. Publications de l'auteur p. 214-215.
6

Imagerie numérique ultrasonore pour la détection automatique de défauts en contrôle non destructif /

Moysan, Joseph. January 1992 (has links)
Th. doct.--Phys.--Lyon--Inst. natl. des sci. appliquées, 1992. / Bibliogr. p. 234-251. Résumé en français et en anglais.
7

Cerebral vascular patterns associated with theta and gamma rhythms during unrestrained behavior and REM sleep / Réponses hémodynamiques cérébrales associées aux rythmes thêta et gamma lors du mouvement libre et du sommeil paradoxal

Bergel, Antoine 13 December 2016 (has links)
Le rythme thêta est un rythme cérébral associé à l’activité locomotrice et au sommeil paradoxal. Bien que son implication dans la communication entre régions du cerveau et processus mnésiques ait largement été démontrée, il persiste un manque de données extensives dû à la difficulté d’imager l’ensemble de l’activité cérébrale dans des conditions naturelles de locomotion et d’exploration. Dans cette thèse, j’ai développé une approche qui combine l’enregistrement des potentiels de champs locaux à l’imagerie ultrasonore fonctionnelle (fUS) sur l’animal en mouvement libre. Pour la première fois, j’ai pu révéler les réponses hémodynamiques associées au rythme thêta dans la plupart des structures du système nerveux central avec de bonnes résolutions spatiale (100 x 100 x 400 μm) et temporelle (200 ms). Pendant la locomotion et le sommeil, les variations hémodynamiques de l’hippocampe, du thalamus dorsal et du cortex (rétrosplenial, somatosensoriel) corrèlent fortement avec la puissance instantanée du signal thêta hippocampique, avec un décalage temporel variant de 0.7 s à 2.0 s selon les structures. De manière intéressante, les rythmes gamma hippocampiques moyen (55-95 Hz) et rapide (100-150 Hz) expliquent la variance des signaux hémodynamiques mieux que le seul rythme thêta, alors que le rythme gamma lent (30-50 Hz) est non pertinent. L’hyperémie fonctionnelle de l’hippocampe suit séquentiellement la boucle tri-synaptique (gyrus denté - région CA3 - région CA1) et se renforce considérablement à mesure que la tâche progresse. Lors du sommeil paradoxal, j’ai observé une hyperémie tonique globale ainsi que des activations phasiques de grande amplitude initiées dans le thalamus et terminant dans les aires corticales, que nous avons appelées “poussées vasculaires”. De fortes bouffées d’activité gamma rapide (100-150 Hz) précèdent de manière robuste ces poussées vasculaires, l’inverse n’étant pas vrai. Dans l’ensemble, ces résultats révèlent la dynamique spatio-temporelle des signaux hémodynamiques associés à la locomotion et au sommeil paradoxal et suggèrent un lien fort entre rythmes thêta, gamma rapide et activité vasculaire globale / Theta rhythm is a prominent oscillatory pattern of EEG strongly associated with active locomotion and REM sleep. While it has been shown to play a crucial role in communication between brain areas and memory processes, there is a lack of extensive data due to the difficulty to image global brain activity during locomotion behavior. In this thesis, I developed an approach that combines local field potential recordings (LFP) and functional ultrasound imaging (fUS) to unrestrained rats. For the first time, I could image the hemodynamic responses associated with theta rhythm in most central nervous system (CNS) structures, with high spatial (100 x 100 x 400 μm) and temporal (200 ms) resolutions. During running and REM sleep, hemodynamic variations in the hippocampus, dorsal thalamus and cortices (S1BF, retrosplenial) correlated strongly with instantaneous theta power, with a delay ranging from 0.7 to 2.0 s after theta peak. Interestingly, mid (55-95 Hz) and high gamma (100-150 Hz) instantaneous power better explained hemodynamic variations than mere theta activity, while low-gamma (30-50 Hz) did not. Hippocampal hyperaemia followed sequentially the trisynaptic circuit (dentate gyrus - CA3 region - CA1 region) and was considerably strengthened as the task progressed. REM sleep revealed brain-wide tonic hyperaemia, together with phasic high-amplitude vascular activation starting in the dorsal thalamus and fading in cortical areas, which we referred to as “vascular surges”. Strong bursts of hippocampal high gamma (100-150 Hz) robustly preceded these surges, while the opposite was not true. Taken together, these results reveals the spatio-temporal dynamics of hemodynamics associated with locomotion and REM sleep and suggest a strong link between theta, high-gamma rhythms and brain-wide vascular activity.
8

Ensemble de niveaux robustes au speckle et recalage B-spline application à la segmentation et l'analyse du mouvement cardiaque par des images ultrasons /

Mora Cofré, Marco Ayache, Alain January 2008 (has links)
Reproduction de : Thèse de doctorat : Informatique : Toulouse, INPT : 2008. / Titre provenant de l'écran-titre. Bibliogr. 235 réf.
9

Imagerie ultrasonore quantitative haute fréquence

Le Floc'h, Johann Vray, Didier. January 2005 (has links)
Thèse doctorat : Acoustique : Villeurbanne, INSA : 2003. / Les chapitres 3 et 4 sont rédigés en anglais. Titre provenant de l'écran-titre. Bibliogr. p. 137-154.
10

Transducteurs capacitifs micro-usinés pour l'imagerie échographique / Capacitive Micromachined Ultrasonic Transducers for ultrasound imaging

Legros, Mathieu 03 June 2013 (has links)
La conception des sondes ultrasonores pour l’imagerie médicale est traditionnellement basée sur l’utilisation de matériaux piézoélectriques. Depuis quelques années, est apparue la technologie des CMUTs, (Capacitive Micromachined Ultrasonic Transducers). Ces microsystèmes électromécaniques se présentent comme une alternative attractive à la piézoélectricité, offrant la possibilité d’explorer de nouveaux designs de sonde, et d’expérimenter de nouveaux modes d’imagerie. Ce travail s’inscrit dans une dynamique de développement et d’évaluation des sondes CMUTs, de la modélisation à la démonstration par l’image. Des transducteurs multi-éléments CMUTs ont ainsi été conçus, et des prototypes de sondes d’échographie finalisés ont pu être réalisés, ce en adaptant les développements à la transduction capacitive et aux systèmes d’imagerie conventionnels. Leurs comportements électroacoustiques et acoustiques ont été étudiés et comparés à des sondes standards. Finalement, des démonstrations par l’image ont été apportées, et les points forts de cette technologie pour l’imagerie médicale ont pu être établis. / Fabrication of ultrasound probes for medical imaging conventionally exploits piezoelectric based materials. CMUTs technology (Capacitive Micromachined Ultrasonic Transducers) has emerged about a decade ago. These electromechanical micro-systems are presented as an alternative transduction mode, and gives new opportunities for probe design and novel imaging techniques. This dissertation aims to develop and review CMUTs probes for ultrasound imaging, from modeling to imaging demonstration. Multi-elements transducers with CMUT technology have been thus developed, and ultrasound probes were successfully achieved. Developments have been carried out, taking care of both capacitive transduction and standard ultrasound systems. Electro-acoustic and acoustic behavior were evaluated and compared to the state of the art piezoelectric probes. Finally, quantitative imaging assessments have been performed and have pointed out the strengths of CMUT technology for ultrasound imaging

Page generated in 0.0915 seconds