Spelling suggestions: "subject:"implant complémentaire"" "subject:"emplant complémentaire""
1 |
Ostéo-intégration des implants dentaires à partir de l’étude de recherche clinique ZIR-ROC : matériaux, techniques opératoires, limites et perspectives / Dental implant Osseointegration : ZIR-ROC clinical research : materials, operative surgery, limits and perspectivesFauroux, Marie-Alix 13 December 2016 (has links)
Introduction : Depuis les premiers implants dentaires Bränemark, les techniques chirurgicales et les matériaux implantaires ont évolué. La référence en terme de matériau implantaire est le Titane. Cependant, d’autres matériaux comme le Zircone ont été proposés pour suppléer le Titane en cas d’allergie au Titane mais aussi pour améliorer la bio-intégration de l’implant dentaire et l’esthétique. Les facteurs de risques d’échec implantaire des implants en Titane incluent, entre autre, l’hygiène orale, la consommation de tabac et la mise en charge immédiate. Objectif : L’étude ZIR-ROC a donc été menée dans le but d’étudier le taux de survie de ces implants zircone après 2 ans de suivi, de recueillir des informations sur l’intégration tissulaire des implants et de rechercher les facteurs de risque d’échec des implants en Zircone. Matériel et méthode : l’étude ZIR-ROC a été menée dans le service de chirurgie orale du CHU de Montpellier sur des implants monobloc en Zircone de la société Paris Implant®. La pose de 43 implants a été déterminée pour permettre l’analyse statistique des résultats. Le forage et l’insertion des implants ont été réalisés à l’aide du système de chirurgie guidée 2ingis®. La variable principale pour évaluer l’ostéo-intégration des implants a été le score délivré par le Periotest®. 22 variables secondaires ont été recueillies tels que les indices gingivaux et de plaque ainsi que l’analyse rétro-alvéolaire. Les données ont été relevées juste avant la chirurgie implantaire, ainsi qu’à 1 semaine, 4 semaines, 5 mois, 1 an et 2 ans. La méthode de Kaplan-Meier, le modèle de Cox et les analyses en composantes principales ont été utilisés pour l’analyse statistique. Résultats : Tous les implants ont présenté une bonne stabilité primaire post-opératoire (valeurs du Periotest comprises entre -8 et +1 ; moyenne à -5,7). Le taux d’échec implantaire a atteint 31% après les 5 premiers mois d’ostéo-intégration. Une mobilité clinique a été observée pour les implants perdus. Les facteurs de risque décrits dans la littérature ont été retrouvés dans le modèle de Cox avec une significativité pour la consommation de tabac et d’alcool et sans significativité statistique pour la densité osseuse ou encore la mise en place d’une couronne provisoire. Par ailleurs, la présence de plaque et d’inflammation gingivale a été observée en faible quantité sur les implants en Zircone. Discussion et conclusion : Le Zircone apparaît comme un matériau biocompatible pour des implants dentaires. Les causes des échecs implantaires précoces observés sont probablement multiples et cette étude n’a pas permis de démontrer l’implication seule de la Zircone dans ces échecs. La recherche des facteurs d’échecs implantaires a conduit à évaluer la technique chirurgicale utilisée pour cette étude mais aussi le dessin de l’implant. De plus, une étude in vitro comparant des implants à base de Zircone et de Titane a été entreprise pour évaluer l’affinité de cellules souches d’origine dentaire pour les 2 matériaux. / Introduction: Since first Bränemark dental implants were implanted, operative surgery and materials for implantation have evolved. Titanium was the gold standard for dental implant material. But others materials like Zirconium were studied in replacement of Titanium due to allergy, bio-integration end aesthetic reasons. Contributing risk factors of Titanium implant failure include oral hygiene, tabacco and early loading among others factors. Objective: The aim of this clinical study was to evaluate survival rate of Zircon implants after 2 years, to collect information for tissue integration of Zirconium implant and to identify risk factors for Zircon implant failure. Material and Methods: ZIR-ROC study, conducted in the Oral Surgery Departement in Montpellier University Hospital, used zircon monobloc (ZIR-ROC®) implants (Paris Implant Society®). 43 implants were required for statistical analysis. Drilling and implantation were conducted with 2ingis® surgical guide system. The Periotest® value was the first endpoint for the implant osseointegration analysis. Gingival and dental plaque indices as well as intraoral X-ray analysis were part of the 22 secondary variables. Data were collected just after implantation surgery, and then, 1 week, 4 weeks, 5 months, 1 year and 2 years after implantation. Kaplan-Meier method, Cox regression model and principal component analysis were used for statistical analysis. Results: All implants showed postoperative optimal primary stability (Periotest® values between -8 and +1; mean: -5,7). Implants failure rate reached 31 percent after the 5 initial months of osseointegration. Clinical mobility was observed for the failed implants. Risk factors published in the scientific literature were observed in the Cox regression model with significant statistical effect for tobacco and alcohol consumption but without significant statistical effect for osseous density or even temporary crown insertion. Furthermore, gingival inflammation and dental plaque presence were low on Zircon implant. Discussion and Conclusion: Zirconium remains a biocompatible material for dental implantation but there were probably many reasons for the observed early implant failures and this study could not demonstrate the only involvement of Zirconium based material. Operative surgery used in this clinical study and the design of the implants were studied for researching other risk factors. In addition, an in vitro study comparing Zirconium versus Titanium as gold standard, was conducted for testing affinity of dental stems cells on Titanium and Zirconium-based dental materials.
|
2 |
Contribution à l’étude de l’endommagement des connexions implantaires en odontologie prothétique / Contribution to the study of the damage in dental implant connectionCorne, Pascale 19 December 2018 (has links)
Cette recherche est basée sur l’étude de deux niveaux d’endommagements de la connexion implantaire : en premier lieu, l’usure liée aux différents cycles d’insertion/désinsertion nécessaire à l’élaboration d’une prothèse sur des échantillons implantaires ; et d’autre part, les endommagements au cours du temps, réalisés à l’aide d’une étude par fretting-corrosion en salive humaine. Lors des différents cycles de serrage/desserrage, des endommagements sur l’ensemble des composants sont présents. La vis implantaire, qui concentre la majorité des complications thérapeutiques, doit être renouvelée après 20 cycles de serrage maximum. L’utilisation de vis de laboratoire permet ainsi de limiter les dégradations sur cette dernière et d’optimiser la valeur de précontrainte lors du serrage d’usage. Lorsque la prothèse est mise en service, les endommagements sont principalement liés à des usures par tribocorrosion. Ce phénomène est à l’origine d’usure synergique et engendre une modification de la microstructure en regard des surfaces frottée / This research based on the study of two levels of damage focused on the implant connection: firstly, the wear associated with the opening/closing cycle dedicated to the manufacturing process; secondly, the damage over the time, that is a fretting-corrosion study of dental implants in human saliva. During the tightening/loosening cycles, damage to all the components is present. The screws that include the majority of the complications have to be changed after 20 tightening cycles. The use of laboratory screws limits the damage and optimizes the preload value. When the prosthesis and the implant are assemblies, the damage appears thanks to fretting/corrosion (tribocorrosion) behavior. This phenomenon does involve synergistic wear and a modification of the microstructure on the fretting surfaces
|
3 |
Synthèse et caractérisations physico-chimiques et biologiques de revêtements implantaires bioactifs / Synthesis and physicochemical and biological characterization of bioactive implant coatingsD'Almeida, Mélanie 15 December 2014 (has links)
L'accès aux soins dentaires est devenu, au cours de ces dernières années, un service de plus en plus demandé par la population. En particulier, la pose d'un implant, destiné à remplacer une dent manquante, en recréant une racine artificielle, devient un acte de plus en plus courant. Une des principales sources de complications entrainant l'échec de la pose d'un implant est une maladie inflammatoire : la péri-implantite. Cette maladie induit la perte des os de soutien dans les tissus entourant l'implant fonctionnel. Actuellement, il n'existe pas d'implant prévenant ces infections bactériennes, seuls des traitements curatifs sont proposés. Le développement d'un traitement antibactérien implantaire apparaît alors comme une solution préventive pertinente pour limiter les complications post-opératoires et représente un défi de santé publique. Pour parvenir à cet objectif, dans ce travail de thèse, plusieurs solutions pour préparer un revêtement implantaire bioactif ont été étudiées et évaluées. Elles sont toutes basées sur le recouvrement d'une surface modèle de titane par un polymère naturel bioactif, le chitosane. Le greffage du biopolymère au substrat a été réalisé via une liaison covalente en utilisant un agent de couplage. Les différentes étapes de la synthèse du revêtement ainsi que ses propriétés biologiques ont été caractérisées à l'aide de techniques d'analyses de chimie de surface, par des études de tenue et de restitution du biopolymère en milieu acide ainsi que par des études in vitro de l'activité antibactérienne et des propriétés biologiques des revêtements. Les résultats de ce travail ont permis de sélectionner le revêtement bioactif possédant les meilleurs propriétés pour l'application visée, notamment en raison de sa tenue en milieu acide et de son activité antibactérienne en présence des bactéries communes / In the past years, population requirement for dental care service increased. More precisely, replacement of missing tooth using dental implant is now a common intervention. As implant provides an artificial root, this procedure is permanent. The failure of the placement procedure is mainly due to an inflammatory disease: peri-implantitis. This disease leads to the death of bone tissues surrounding the dental implant. Today only curative solutions are available, and no implants can prevent bacterial development. It appears that preventing post-surgical complications by designing antibacterial implants is now a public health issue. To achieve this goal, we evaluate in this thesis different solutions to design bioactive implant coatings. We focused our work on coating of a model titanium surface by a bioactive polymer: chitosan. Polymer binding on the substrate is achieved by covalent link using a coupling agent. We described each step of the coating synthesis and characterized its biological properties using both surface chemistry analysis and cell biology techniques. We studied its behavior in an acid environment and analyzed its biological and antibacterial properties in vitro. Results of this work were used to select the bioactive coating with the best properties for the intended application, particularly due to its resistance in acidic condition and its antibacterial activity against common bacteria
|
4 |
Impact des tissus mous sur les méthodes acoustiques d’évaluation de la stabilité des implants osseux. / Impact of soft tissues on acoustic methods for the stability assessment of bone implantsBosc, Romain 12 January 2018 (has links)
Ce travail porte sur l’étude du comportement biomécanique d’un modèle cadavérique et d’un modèle in vitro de l’arthroplastie totale de hanche. Nous avons cherché à mettre en relief et à étudier des paramètres qui pouvaient nous permettre de disposer d’une méthode d’analyse objective de la stabilité de l’implant acétabulaire. La première partie décrit le contexte de l'étude. Nous avons insisté sur les différentes méthodes d’analyses qui permettent d’analyser la stabilité d’un implant osseux. En effet, malgré l’utilisation quotidienne des implants, le taux d’échec d’ostéointégration reste élevé. Ces échecs s’accompagnent d’une morbidité importante et d’un surcout notable. Parmi les causes d’échec identifiées, le descellement aseptique de la cupule acétabulaire dans l’arthroplastie de hanche peut être lié à un défaut de stabilité primaire, non obtenu lors de l’intervention chirurgicale. Il a été montré que le descellement de la cupule acétabulaire pouvait résulter d'une faible stabilité primaire entre la cupule et l'os l'entourant. Les chirurgiens qui pratiquent l’arthroplastie de hanche évaluent de manière empirique la stabilité obtenue ou non de l’implant acétabulaire en écoutant le son produit lorsqu'ils impactent la cupule ou à leur ressenti en la manipulant. Une méthode d'estimation de la stabilité primaire pourrait permettre au chirurgien orthopédique de mieux appréhender la stabilité des implants qu’il pose au bloc opératoire. L'objet principal de ce travail de thèse était ainsi d'étudier les signaux d'impacts sur le cotyle prothétique. Dans un premier temps, nous avons réalisé une étude de l'insertion de la cupule par impacts sur un modèle cadavérique (sujets anatomiques de l’école de chirurgie du fer à moulin) dans des conditions proches de celle de l'opération en clinique. Une corrélation a été trouvée entre le moment d'impact et la stabilité (R2=0.69). Cette étude expérimentale a ainsi montré le potentiel de la méthode de traitement des signaux d'impact dans la prédiction de la stabilité primaire de la cupule acétabulaire. Mais nous avons observé des modifications entre les signaux obtenus sur les différents sujets. Nous avons posé comme hypothèse que ces modifications étaient liées à la variation des tissus mous entre chaque sujet. Le troisième volet de cette thèse a donc porté sur l’analyse du comportement biomécanique de notre modèle en présence d’une quantité plus ou moins importante de muscle.Nous avons utilisé à nouveau le modèle in vitro que nous avions développé et avons ajouté dans le système d’impaction des tranches de poitrine de dinde d’épaisseur variable. Le but de cette seconde étude était d’intégrer le paramètre lié à l’existence d’une épaisseur variable de tissus mous dans l'interaction dynamique entre le marteau, l'ancillaire (et la cupule) et le tissu osseux lors de l'insertion. La valeur de la moyenne et de l’écart-type de l'indicateur Im obtenues pour tous les échantillons et toutes les configurations pour une valeur d’épaisseur des tissus mous égale à 10 mm (respectivement 30 mm) étaient égales à 0,592 ± 0,141 (respectivement 0,552 ± 0,139). L’analyse statistique a montré qu'il n'y avait pas eu d'effet significatif de la valeur de l’épaisseur des tissus mous sur les valeurs de l'indicateur Im (F = 3,16; p = 0,08). Malgré les limitations évidentes d’une étude in vitro sur un modèle partiel d’arthroplastie totale de hanche, ces résultats, ainsi que les résultats précédents obtenus sur les sujets anatomiques, montrent la faisabilité du développement d'un dispositif médical dédié à l'estimation de la stabilité de l'implant acétabulaire et qui pourrait être utilisé comme système d'aide à la décision par le chirurgien orthopédique. / Abstract:This work studies the biomechanical behavior of a cadaveric model and an in vitro model of total hip arthroplasty. We sought to highlight and study parameters that could allow us to have a method of objective analysis of the stability of the acetabular cup implant.The first part describes the context of the study. We have emphasized the different methods of analysis that make it possible to analyse the stability of a bone implant. Indeed, despite the daily use of implants, the failure rate of osseointegration remains high and failures still happen due to inadequate mechanical behavior of the prosthesis.Among the identified causes of failure, aseptic loosening of the acetabular cup after hip arthroplasty may be related to a primary defect in stability, not achieved during the surgical procedure. It has been shown that loosening of the acetabular cup may result from poor primary stability between the prosthetic cup and the surrounding bone.A method of estimating primary stability could allow the orthopaedic surgeon to better control the stability of the implants he poses in the operating room.The main purpose of this thesis work was to study the impact signals on the prosthetic acetabulum.Firstly, we carried out a study of the insertion of the cup by impacts on a cadaveric model. A correlation was found between impact time and stability (R2 = 0.69). This experimental study has thus shown the potential of the impact signal processing method in predicting the primary stability of the acetabular cup. But we observed changes between the signals obtained on the different subjects. We hypothesized that these changes were related to soft tissue variation between subjects.The third part of this thesis focused on analysing the biomechanical behavior of our model in the presence of soft tissues.We used again the in vitro model that we had developed and added in the impaction system turkey slices of varying thickness.The purpose of this second study was to integrate the parameter related to the existence of a variable thickness of soft tissues in the dynamic interaction between the hammer, the ancillary (and the cup) and the bone tissue during the insertion. The mean and standard deviation of the Im indicator obtained for all samples and configurations at a soft tissue thickness value of 10 mm (30 mm) was 0.592 ± 0.141, (respectively 0.552 ± 0.139). Statistical analysis showed that there was no significant effect of the value of soft tissue thickness on the values of the Im indicator (F = 3.16, p = 0.08). Despite the obvious limitations of an in vitro study on a partial model of total hip arthroplasty, these results, as well as the previous results obtained on anatomical subjects, show the feasibility of developing a medical device dedicated to estimating the stability of the acetabular implant and which could be used as a decision support system by the orthopaedic surgeons.
|
5 |
Contribution de l'analyse mécanique à l'étude des implants et des biomatériaux dentairesFaudemer, Gonzague 14 February 2013 (has links)
La solution la plus favorable cliniquement au remplacement des dents absentes est aujourd’hui la mise en place d’implants dentaires. Cette technique nécessite la maîtrise de plusieurs problématiques qui s’articulent autour des interfaces du système. Celles-ci sont au nombre de trois soit : l’interface os-implant, l’interface implant-pilier prothétique et l’interface pilier prothétique-prothèse. Dans cette étude, nous analysons les matériaux mis en présence au sein des interfaces et ce, par le biais de l’analyse mécanique afin d’apporter une contribution objective au choix clinique des matériaux par les praticiens. Les substituts osseux sont ainsi étudiés sous le prisme de leur stabilité mécanique, servant de trame à la reconstruction osseuse au contact de l’implant. Plusieurs systèmes implantaires (ensemble implant-pilier prothétique) sont ensuite étudiés pour en évaluer également la stabilité, gage de solidité du système et d’absence de dévissage. Enfin, plusieurs polymères dentaires sont évalués et comparés afin d’établir leur apport dans la solidité du complexe implanto-prothétique. / Today, the most favorable clinical solution for replacing absent teeth are dental implants. Several problems has to be addressed to master this technique, in particular those concerning the design of the many interfaces of this system. The three main interfaces are : the bone-implant junction, the implant-prosthetic pillar contact and prosthetic pillar-prosthesis assembly. In this study, the mechanical behavior of the constitutive materials of the system is evaluated to supply unbiased criteria to the practitioners for selecting the right materials in clinical conditions. Thus, bones substitutes are studied to evaluate their mechanical stability which is necessary condition to ensure bone reconstruction in contact with the implant surface. Then, several implant systems (implant + prosthetic pillar) are tested to estimate their stability, which guaranty solid system and prevent from any unscrewing failure. Finally, several dental polymers are evaluated and compared to establish their contribution in the implanto-prosthetic system robustness.
|
6 |
Étude de l’expression des cytokines et métalloprotéases dans les tissus péri-implantaires inflammatoires et rôle potentiel du titane dans les péri-implantites / Cytokines & metalloproteases expression in peri-implant inflammatory tissues and the potential involvement of titanium in peri-implantitisGhighi, Maxime 04 December 2017 (has links)
Les péri-implantites se caractérisent par une destruction inflammatoire irréversible des tissus qui entourent l’implant dentaire. Leur pathogénie est proche des parodontites, maladies inflammatoires chroniques d’étiologie bactérienne entrainant une destruction irréversible de l’os alvéolaire soutenant les dents. Cependant, la réponse inflammatoire et la résorption osseuse diffèrent entre péri-implantites et parodontites. De plus, les traitements conventionnels non chirurgicaux ne sont pas efficaces pour le traitement des péri-implantites. L’objectif de notre travail est d’analyser les différences entre les médiateurs inflammatoires et cataboliques des tissus péri-implantaires en comparaison aux tissus parodontaux malades après une thérapie conventionnelle non chirurgicale. Nous avons bâti une collection biologique d’explants humains de tissus conjonctifs péri-implantaires ou parodontaux malades. Une analyse Multiplex des milieux conditionnés et histologiques des explants a révélé une expression accrue de l’inhibiteur de métalloprotéase TIMP-2, de l’interleukine IL-10 et du RANK-L dans les tissus péri-implantaires. En accord avec une revue de littérature que nous avons mené dans la seconde partie de notre travail, notre hypothèse est que ces différences s’expliqueraient, tout du moins en partie, par la présence de particules de titane au niveau des tissus péri-implantaires. Notre travail participe à la compréhension de la pathogenèse de la maladie et concourt à l’identification de biomarqueurs potentiels pour le pronostic ou le développement d’approches thérapeutiques. / Peri-implantitis lesions present an irreversible destruction of the peri-implant surrounding tissues. The pathogenic pathway of peri-implantitis is close from the one of periodontitis which is a chronic inflammatory disease caused by a bacterial biofilm leading to irreversible supportive bone destruction around teeth. Still, the inflammatory process and the bone destruction differ between the two diseases. In addition, conventional non-surgical treatments are not effective for the treatment of peri-implantitis. The aim of our work is to analyze the differences between inflammatory and catabolic mediators of peri-implant tissues compared to diseased periodontal tissues after conventional non-surgical therapy. We have constructed a biological collection of human explants of peri-implant or periodontal connective tissue. Multiplex assays of the conditioned media and histological analysis of the explants revealed an increased expression of the TIMP-2 metalloprotease inhibitor, interleukin IL-10, and RANK-L in the peri-implant tissues. In agreement with a review of literature that we conducted in our work, our hypothesis is that these differences can be explained, at least partly, by the presence of titanium wear particles in the peri-implant tissues. Our work contributes to the understanding of the pathogenesis of the disease and contributes to the identification of biomarkers.
|
7 |
Étude comparative de méthodes ultrasonores non linéaires appliquées à des modèles expérimentaux de scellement et/ou d'ostéointégration de prothèsesRivière, Jacques 16 December 2012 (has links) (PDF)
Ce travail de thèse s'inscrit dans la perspective à long terme d'implémenter in vivo de nouvelles méthodes non invasives de contrôle du scellement ou de l'ostéointégration de prothèses osseuses (implants dentaires, prothèses de hanche). Bien qu'étant la plus utilisée cliniquement, la radiographie à rayons X souffre d'une faible sensibilité. Le potentiel de méthodes développées ces vingt dernières années et fondées sur des mesures d'élasticité, a été démontré in vitro, mais leur efficacité in vivo est encore sujette à caution. Notre objectif a été d'évaluer le potentiel de nouvelles méthodes basées sur la mesure de la réponse élastique non linéaire, méthodes qui sont apparues dans les domaines de la géophysique et du contrôle non destructif, et qui ont montré une plus grande sensibilité que la réponse linéaire élastique à la présence de contacts faibles au sein d'une structure rigide, tels que les fissures. Pour cela, plusieurs modèles d'ostéointégration et de scellement (avec conditions aux limites ou conditions d'amortissement variées) ont donc été étudiés expérimentalement à l'aide de différentes techniques d'élasticité non linéaire. Au final, cette étude expérimentale a permis l'extraction des paramètres non linéaires les plus prometteurs et d'évaluer leurs avantages et limites respectifs en vue de leur application in vivo.
|
8 |
Contribution de l'analyse mécanique à l'étude des implants et des biomatériaux dentairesFaudemer, Gonzague 14 February 2013 (has links) (PDF)
La solution la plus favorable cliniquement au remplacement des dents absentes est aujourd'hui la mise en place d'implants dentaires. Cette technique nécessite la maîtrise de plusieurs problématiques qui s'articulent autour des interfaces du système. Celles-ci sont au nombre de trois soit : l'interface os-implant, l'interface implant-pilier prothétique et l'interface pilier prothétique-prothèse. Dans cette étude, nous analysons les matériaux mis en présence au sein des interfaces et ce, par le biais de l'analyse mécanique afin d'apporter une contribution objective au choix clinique des matériaux par les praticiens. Les substituts osseux sont ainsi étudiés sous le prisme de leur stabilité mécanique, servant de trame à la reconstruction osseuse au contact de l'implant. Plusieurs systèmes implantaires (ensemble implant-pilier prothétique) sont ensuite étudiés pour en évaluer également la stabilité, gage de solidité du système et d'absence de dévissage. Enfin, plusieurs polymères dentaires sont évalués et comparés afin d'établir leur apport dans la solidité du complexe implanto-prothétique.
|
9 |
Étude de l'impact d'une prothèse dentaire implanto-portée sur le comportement des articulations temporo-mandibulaires et de l'os péri-implantaire / Study of fixed overdenture prosthesis impact on the behaviour of temporo-mandibular joints and peri-implant boneCreuillot, Victor 29 September 2016 (has links)
Cette thèse aborde une étude biomécanique de l’appareil stomatognathique en vue d’analyser les conséquences sur les articulations temporo-mandibulaires (ATM) de la mise en place d’une prothèse complète implanto-portée. Cette étude est réalisée à l’aide de la méthode des éléments finis. Dans ce travail, deux modèles ont été créés. Un premier est basé sur la géométrie d’un sujet sain volontaire sans problèmes articulaires ni dentaires. Un deuxième, avec une restauration de la dentition par une prothèse dentaire complète sur implants, repose sur la géométrie des structures osseuses du cas sain. Une méthodologie a été mise en place pour la construction du modèle éléments finis, basé sur celle développée dans la thèse d’Alvarez. Une comparaison des résultats est effectuée entre les modèles du cas sain d’Alvarez et celui exposé dans ce travail afin d’évaluer l’influence des modifications apportées et de valider ce dernier. Puis une comparaison est effectuée entre le cas sain et restauré pour une ouverture/fermeture modérée de la mâchoire ainsi que lors de la morsure d’aliments au niveau des incisives. Une autre problématique abordée dans cette thèse est l’analyse du risque d’échec de l’implantation dans l’os dont la qualité est dégradée par la perte des dents. Deux géométries d’implants ont été testées pour différentes qualités osseuses, un implant classique et un implant nouvellement breveté / This study deals with a biomechanical analysis of the stomatognathic system in order to understand the consequences of complete fixed dental prosthesis on temporomandibular joint (TMJ). The finite element method is used to achieve this goal. Two models have been created, a healthy and restored by prosthesis ones. The first model is based on a healthy volunteer subject morphology, without dental or articular troubles. The restored model is based on the bony structures of the healthy individual. Mandibular teeth have been removed numerically and a complete fixed overdenture has been settled on the mandible. The construction of the finite element model has been set up following the method developed by Alvarez. A comparison between results obtained by both approaches on the healthy case has been done to validate our model and to evaluate the impact of the improvements proposed in this work on mandible behavior. Then a comparison between the healthy and restored cases is done for a moderate opening /closing motion of the jaw and for a foodstuff bite between the incisors. Another problematic is treated in this thesis, the risk of peri-implant bone damage. Teeth lose induce a bone quality degradation that could cause the implantation failure. Two implant geometries have been tested for different bone qualities during clenching. In the first case, the classical implants, frequently employed by dentists, have been used. In the second case, the advantages of the newly patented implant, composed of a vertical and horizontal screws, have been tested
|
10 |
Variabilité diachronique de la courbe de Spee : exemples d'applications à l'anthropologie funéraire et à l'odontologie clinique / Diachronic variability of the curve of Spee : example of applications in the funeral anthropology and in the clinical odontologyRé, Jean-Philippe 06 December 2016 (has links)
La courbe de Spee est une courbe située dans un plan para-sagittal. Son étude se fait uniquement au niveau des dents mandibulaires. Il ne s’agit pas d’un « simple » plan d’occlusion dentaire puisque cette courbe intéresse, également de l’os, c’est à dire le condyle mandibulaire et plus particulièrement son bord antérieur. La courbe de Spee est dépendante de l’emplacement du condyle mais également de l’axe de chacune des dents mandibulaires qui participent à sa forme. Son incurvation permet d’aligner les directions des contraintes le long des grands axes dentaires. À partir des valeurs métriques et angulaires mesurées sur des images 3D de mandibules numérisées les objectifs ont été : - de proposer une aide dans la reconstruction de mandibule incomplète et/ou déformée et du plan occlusal absent ou incomplet. - de dégager des principes géométriques simples permettant une optimisation du positionnement des racines artificielles (implants) chez l’Homme actuel. Ainsi les études des axes dentaires mandibulaires, de la position du condyle mandibulaire, de la courbe de Spee, ou encore de différentes mesures mandibulaires, ont permis de dégager un axe de recherche anthropologique et un axe de recherche odontologique Un axe anthropologique Qui amène à la découverte validée de formules de régressions pouvant apporter une aide dans la reconstructions de matériel dentaire, ou osseux incomplet, mandibulaire. Un axe odontologique Qui confirme, et valide cliniquement, que les axes dentaires mandibulaires doivent être orientés le plus favorablement possible en fonction des diverses contraintes occlusales. / The curve of Spee is situated in a para-sagittal plane. His study is done only at the mandibular teeth. It is not a "simple" plan of dental occlusion because this curve interests, also of bone, the mandibular condyle and particularly its front edge. The curve of Spee depends on the condyle location but also on the axis of each of the mandibular teeth which participate in its shape. Its curve aligns the directions of the constraints along major dental axes. From metrics and angular values measured on 3D images of scanned mandibles, the objectives were: - To propose a help in the reconstruction of incomplete and / or deformed mandible and absent or incomplete occlusal plane. - To identify simple geometric principles to optimize the positioning of the artificial roots (implants) in modern Man. So the studies of mandibular dental axes, the position of the mandibular condyle, the curve of Spee, or differents mandibular measures allowed to clear an area of anthropological research and an area of Dental Research An anthropological area Which leads to the validated discovery regression formulas, which can brings help in reconstruction of dental material, or osseous incomplete, mandibular. An odontological area Which confirms and validates clinically, that the mandibular dental axes must be oriented as favorably as possible according to the various occlusal constraints.
|
Page generated in 0.0636 seconds