• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 5
  • 2
  • 1
  • Tagged with
  • 26
  • 26
  • 16
  • 15
  • 13
  • 12
  • 10
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efeito do jateamento com óxido de alumínio e uso de adesivo, no afrouxamento do parafuso de pilares protéticos cônicos, com indexador de restaurações implanto suportadas / Effect of aluminium oxide blasting and use of adhesive on abutment screw loosening torque of morse taper with index for implant-supported restorations

Patrícia Mitiko Asanuma Hirayama 26 September 2012 (has links)
O sucesso dos trabalhos protéticos, executados sobre os implantes osseointegrados, depende da estabilidade da conexão entre implante e pilar protético. Dentre as conexões protéticas existentes, as conexões cônicas têm demonstrado um desempenho melhor, tanto em termos mecânicos, como biológicos. A retenção friccional do pilar cônico é a grande responsável pela resistência aos movimentos laterais e oclusais da mastigação. Com a introdução de indexadores no desenho dessas conexões a característica mecânica mudou, levantando dúvidas em relação a sua atuação. Neste trabalho, avaliou-se o efeito do jateamento e uso do adesivo no torque de desaperto dessas conexões. Vinte e oito pilares synOCta® da marca Straumann® foram avaliados quanto ao torque de aperto inicial de 35 N.cm e torque de desaperto após ciclagem mecânica. Três grupos experimentais foram testados em relação ao grupo controle: modificação da superfície cônica por jateamento com óxido de alumínio, aplicação de adesivo entre as partes e o jateamento mais o adesivo. O grupo jateamento com aplicação do adesivo foi o único que apresentou valores de desaperto superiores quando comparado ao grupo controle. A rugosidade criada pelo jateamento, associada ao adesivo, elevou significantemente os valores de torque de desaperto do parafuso em comparação ao torque de aperto. / The success of the prosthetic work performed over dental implants depends on the stability of the connection between implant and abutment. Among the existing prosthetic connections, the conical connections have shown better performance, both mechanical and biological. The frictional retention of the morse taper is largely responsible for the resistance to lateral and occlusal movements of mastication. With the introduction of indexes in the design of these connections, the mechanical characteristic changed, raising doubts about its performance. In this study, we evaluated the effect of blasting and use of adhesive on abutment screw loosening torque of these connections. Twenty-eight synOcta® pillars Straumann® brand were evaluated for initial tightening torque of 35 N.cm and loosening torque after mechanical cycling. Three experimental groups were tested related to the control group: modification of the conical surface by blasting with aluminum oxide, aplication of adhesive between the parties and blasting added to the adhesive. The group blasted with adhesive application was the only one that showed values of loosening torque higher when compared to control group. The roughness created by blasting associated with the adhesive, significantly elevated values of abutment screw loosening torque against the tightening torque.
12

An in vitro assessment of the bacterial sealing capacity of narrow diameter implants with Morse-taper abutment connections.

Alriyahi, Mubarak January 2020 (has links)
Magister Scientiae Dentium - MSc(Dent) / Lack of appropriate bone thickness is a common clinical limitation for tooth replacement, often requiring narrow implants, which have shown better results when combined with Morse taper connections. Little is known about the sealing of the abutment-implant interface of narrow implants with Morse taper connections against oral bacteria.
13

An In vitro Study of Bacterial Leakage of a Novel Implant Abutment Interface

Kabbash, Salma Mohamed Khalifa January 2020 (has links)
Magister Scientiae Dentium - MSc(Dent) / Background: The two-stage implant system has proven to be a successful technique in replacing missing teeth (Nascimento et al., 2008). Nevertheless, the presence of micro-gaps that could entrap microbes at the implant-abutment interface (IAI) is unavoidable. This microbial leakage has been considered as one of the causes of peri-implant infection and bone loss (Scarano et al., 2005). Several companies have attempted to manufacture an implant with a connection design that provides hermetic sealing against bacterial leakage. Studies indicated that implants with internal connection, in particular the conical (Morse taper) design, have better sealing capacity in the implant abutment interface than the external design (Koutouzis et al., 2011, Jaworski et al., 2012). An internal conical implant system with a novel connection design, known as the Grand Morse (GM) connection, is reported to offer secure connection against micro-leakage (Neodent® Implant Systems Inc., 2018). Aims: The aim of this study was to test the sealing ability against bacterial leakage in the implant-abutment interface provided by an implant with a novel deep internal conical (GM) connection design.
14

Fatigue failure load of lithium disilicate restorations cemented on a chairside titanium-base / Effect of restoration design

Kaweewongprasert, Peerapat January 2017 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / PURPOSE: To evaluate the fatigue failure load of distinct lithium disilicate restoration designs cemented on a chairside titanium-base (VariobaseTM for CEREC®, Straumann® LLC, USA) for restoring anterior implant restoration. MATERIALS AND METHODS: Left maxillary incisor restoration was virtually designed in 3 groups (n=10; CTD: lithium disilicate crowns cemented on custom-milled titanium abutments; VMLD: monolithic full-contour lithium disilicate crowns cemented on titanium-base; and VCLD: lithium disilicate crowns cemented on lithium disilicate customized anatomic structures then cemented on titanium-base). The titanium-base was air-abraded with aluminum oxide particles, 50 µm at 2 bars. Subsequently the titanium-base was steamed, air-dried and a thin coat of silane (Monobond Plus, Ivoclar Vivadent®, USA). All ceramic components were surface treated with hydrofluoric acid etching gel, follow by silanized, and bonded with resin cement (Multilink Automix, Ivoclar Vivadent®, USA). Specimens were fatigued at 20 Hz, starting with a load of 100 N (×5000 cycles), followed by stepwise loading up to 1400 N at a maximum of 30,000 cycles each. The failure loads, number of cycles, and fracture analysis were recorded. Data were statistically analyzed using one-way ANOVA followed by pair-wise comparisons (p < 0.05). Kaplan-Meier survival plots and Weibull survival analyses were reported. RESULT: For catastrophic fatigue failure load and total number of cycles for failure, VMLD (1260 N, 175231 cycles) was significantly higher than VCLD (1080 N, 139965 cycles) and CDT (1000 N, 133185 cycles). VMLD had higher Weibull modulus (11.6), demonstrating higher structural reliability. CONCLUSIONS: VMLD performed the best fatigue behavior when compared with the two other groups.
15

Implant-Abutment Interface: A Comparison of the Ultimate Force to Cause Failure between Small Diameter Implant Systems

Mahmoud, Ahmad 18 December 2012 (has links)
No description available.
16

Idealização e desenvolvimento de um dispositivo para avaliação de resistência da interface implante-intermediário protético por meio de ensaios cíclicos de flexão rotativa / Idealization and development of a device for evaluating resistance of implantabutment interface through rotary bending cyclic test

Ferreira, Felipe Ramalho 08 April 2010 (has links)
O sucesso da terapia reabilitadora com implantes requer um equilíbrio entre fatores biológicos e mecânicos. Os fatores biológicos são inúmeros, já os mecânicos associam-se à instabilidade da interface implante-intermediário protético. Com base nestas informações, este estudo busca criar um aparelho com o qual será possível avaliar e comparar a resistência e a estabilidade da interface implante-intermediário protético em implantes de diferentes tipos de sistema de conexão e componentes protéticos, após a aplicação de carga simulada, que será realizada por meio de um ensaio dinâmico de fadiga rotacional, também conhecido como flexão rotativa. Para a criação deste aparelho, vários procedimentos com base em princípios de usinagem CNC (Controle Numérico Computadorizado), engenharia elétrica e física foram utilizados. Os futuros testes e resultados, utilizando-se esse aparelho para realizar o ensaio de fadiga, serão publicados em trabalhos futuros. Para o desenvolvimento dos modelos de corpos de prova a serem analisados na máquina de ensaio, foram utilizados implantes do tipo hexágono externo (Neodent) de 3,75mm de diâmetro x 11.5mm de comprimento. Ao término do desenvolvimento, obteve-se um aparelho confiável, resistente e extremamente versátil; podendo-se facilmente variar a carga exercida e a frequência de rotação, sendo assim possível executar inúmeras combinações de ensaios de fadiga. Esse estudo demonstrou a possibilidade e viabilidade de desenvolver um aparelho adequado para realizar um ensaio de fadiga, de pequena dimensão (portátil) e a um custo significativamente inferior do que comprar um aparelho próprio para tal fim. / The success of a rehabilitation therapy with implant fixtures requires a balance between biological and mechanical factors. The biological factors are innumerable, however the mechanics associate it whit instability of the implant-abutment interface. On the basis of these information, the aim of this study is to create a device which it will be possible to evaluate and to compare the resistance and the stability of the implant-abutment interface whith implants of different connection system and abutments, after the simulated load application, that will be carried through a dynamic assay of rotational fatigue load, also known as rotary bending. For the creation of this device, some procedures on the basis of principles of milling CNC (Computerized Numerical control), electric and physical engineering had been used. The future tests and results, using this device to carry through the fatigue assay, will be published in future works. For the development of the body test to be analyzed in the assay machine, implant fixtures of external hexagon type (Neodent) of 3,75mm of diameter x 11mm of length had been used. In the ending of the development, a trustworthy, resistant and extremely versatile device was gotten; being able itself easily to vary the exerted load and the frequency of rotation, being been thus possible to execute innumerable combinations of fatigue assays. This study demonstrated the possibility and viability of it developing an adequate device to carry through an assay of fatigue, of small dimension (portable) and the significantly inferior cost of what if to buy a proper device for such end.
17

Avaliação mecânica da estabilidade de parafusos protéticos em diferentes sistemas de retenção pilar/implante / Mechanical evaluation of the prosthetic screw stability from different implant/abutment retention systems

Bernardes, Sérgio Rocha 10 October 2008 (has links)
Foi analisada a variação da pré-carga de parafusos durante os cinco primeiros minutos depois de cada uma de cinco seqüências aperto e desaperto de parafusos de implantes dentários com diferentes sistemas de retenção pilar/implante. Extensômetros foram colados no terço cervical de implantes com interface de hexágono externo, hexágono interno e cone Morse. Um procedimento controlado de aperto e desaperto dos parafusos permitiu o arquivo dos valores de torque reverso, em relação ao aperto, e o campo de tensões gerado sobre o terço cervical dos implantes resultante da pré-carga do parafuso para cada uma das seqüências. Foram estudadas 30 amostras de implantes/pilares, dividas em oito grupos: implantes de hexágono externo com intermediário Munhão Universal e parafusos de titânio (Neodent, Curitiba, Brasil) apertados a 32 N.cm (EH.Ti.32); hexágono externo, Munhão Universal, parafuso de titânio recoberto por DLC, 32 N.cm (EH.dlc.32); hexágono interno, Munhão Universal, parafuso de titânio, 20 N.cm (IH.Ti.20); cone Morse, Munhão Universal peça única, 20 N.cm (MT.OP.20); cone Morse, Munhão Universal peça única, 32 N.cm (MT.OP.32); Cone Morse, Munhão Universal parafuso passante, 10 N.cm (MT.TS.10); no sétimo grupo foram usados as mesmas amostras do grupo MT.TS.10 a 10 N.cm, porém o desaperto foi realizado pelo intermediário (MT.TS.10.A); para o último grupo foram usados as mesmas amostras do grupo MT.TS.10 e MT.TS.10.A, porém o aperto dos parafusos foi de 15 N.cm e o desaperto também se deu pelo o intermediário (MT.TS.15.A). Os valores médios e desvio padrão (dp) de pré-carga encontrados para todas as seqüências de cada grupo foram de: EH.Ti.32 (27,75; dp 7,70); EH.dlc.32 (40,17; dp 10,16); IH.Ti.20 (219,61; dp 75,47); MT.OP.20 (129,19; dp 116,71); MT.OP.32 (137,97; dp 47,53); MT.TS.10 (39,55; dp 13,96); MT.TS.10.A (126,72; dp 44,05); MT.TS.15.A (194,41; 68,48). Entre os diferentes sistemas de retenção pilar/implante estudados, pode-se concluir que: existem relações únicas entre o valor de torque aplicado no parafuso e a pré-carga gerada sobre o terço cervical do implante, essas são diretamente influenciados pelo desenho da interface pilar/implante, tipo de parafuso de retenção e valor de torque aplicado; não foi observada perda de pré-carga dos parafusos de pilares, nem perda de resistência à torção no sentido anti-rotacional dos parafusos depois de esperados 5 minutos em 5 seqüências de aperto/desaperto. / The preload screw variation for the first five minutes after each one of five torque/untorque sequences from different implant/abutment retention systems was evaluated. Strain gauges were attached over the cervical third of external hex, internal hex and Morse taper implants. A controlled torque/untorque procedure allowed the record from the preload and untorque values of the samples in each one of the sequences. Thirty implant/abutment samples, divided in eight groups were studied: external hex implants with Universal post and titanium screws (Neodent, Curitiba, Brazil) screwed to 32 N.cm (EH.Ti.32); external hex, Universal post, DLC covered screw, 32 N.cm (EH.dlc.32); internal hex, Universal post, titanium screw, 20 N.cm (IH.Ti.20); Morse taper, single piece Universal post, 20 N.cm (MT.OP.20); Morse taper, single piece Universal post, 32 N.cm (MT.OP.32); Morse taper, Universal post trespassing screw, 10 N.cm (MT.TS.10); the same samples from the MT.TS.10 group were used for the seventh group, screwed to 10 N.cm, but the untorque was performed by the abutment (MT.TS.10.A); the same samples used with the MT.TS.10 and the MT.TS.10.A were used for the last group, but the screws were tightened to 15 N.cm and the untorque remained by the abutment (MT.TS.15.A). The mean and the stardad deviation (DP) found for the preloss in all the five sequences were of: EH.Ti.32 (27.75; SD 7.70); EH.dlc.32 (40.17; SD 10.16); IH.Ti.20 (219.61; SD 75.47); MT.OP.20 (129.19; SD 116.71); MT.OP.32 (137.97; SD 47.53); MT.TS.10 (39.55; SD 13.96); MT.TS.10.A (126.72; SD 44.05); MT.TS.15.A (194.41; SD 68.48). For the retention systems studied, it could be concluded that: there are single relations between screw untorque and preload over the implant cervical third, these are directely influenced by the implant/abutment interface design, screw type and torque value; there were not found post screw preload loss, neither torque resistance at the anti-rotational direction from the screws after the first five minutes in five torque/untorque sequences.
18

Avaliação da capacidade de selamento de intermediários UCLA em um sistema de implante de hexágono externo / Evaluation of UCLA implant-abutment sealing Purpose

Ramos, Marcelo Barbosa 28 June 2013 (has links)
Objetivo. Avaliar a capacidade de selamento e a adaptação de intermediários UCLA, com ou sem uma cinta de cobalto-cromo (CoCr), em um sistema de implante de hexágono externo. Materiais e métodos. 120 implantes hexágono externo (Sistema de Implante Nacional - SIN, SP, Brazil) foram dividos em dois grupos (n=60) para receber intermediários UCLA de 6 fabricantes (n=10), com ou sem cinta pré-fabricada de CoCr (n=60). Os intermediários foram fundidos e subdivididos em 12 grupos da seguinte forma: M (Microplant), I (Impladen), S (SIN), Sv (Signo Vinces), T (TitaniumFix), and B (Bionnovation). A capacidade de selamento foi determinada pela colocação de 0.7 &#x3BC;L de azul de toluidina, 0.1% (TB) no espaço interno dos implantes antes do torque nos intermediários. Os espécimes implante-intemediários foram colocados dentro de tubos de 2.0 mL, contendo 0.7 mL de água destilada, a fim de manter a interface implante-intemediário submersa. Amostras de 100 &#x3BC;l foram coletadas após 1, 3, 6, 24, 48, 72, 96 e 144 horas de incubação para medição da absorbância em um espectofotômetro e devolvidos para medidas subsequentes. Para análise estatística, foram empregados o teste ANOVA a dois critérios (p < 0.05) e o teste de Tukey. Microscopia eletrônica de varredura (MEV) foi usado para visualização da adaptação da interface implante-intermediário. Resultados. Os grupos M, Sv, e T sem cinta CoCr apresentaram completa liberação de corante (TB) em 1 h, enquanto que nos grupos I, S, e B, a liberação do corante ocorreu em 3, 24 e 96 h, respectivamente. Para os intermediários com cinta préfabricada, a completa liberação de corante ocorreu em 6 h para o grupo S, em 24 h para os grupos Sv, T e B, e em 72 h para os grupos M e I. Foram observados desajustes na interface implante/intermediário em todos os grupos. Os desajustes mais evidentes foram observados para os grupos M e T, sem cinta de CoCr. Conclusões. A completa liberação de corante foi observada em diferentes períodos de tempo para todos intermediários UCLA, independentemente, da presença ou não da cinta CoCr. Foram observados espaços ou desajustes na interface implante/intermediário em todos os grupos. / To evaluate the effect of the presence of a prefabricated cobalt-chromium (CoCr) margin in a universal castable long abutment (UCLA) in the sealing capability and fit of the implant-abutment mating zone. Materials andmethods. One-hundred and twenty external hexagon implants (SIN, SP, Brazil) were divided in two groups (n=60 each) to receive UCLA abutments from 6 manufacturers (n=10 each) either with or without a CoCr margin (n=60 each). Abutments were cast and 12 groups were formed and named as: M (Microplant), I (Impladen), S (SIN), Sv (Signo Vinces), T (TitaniumFix), and B (Bionnovation). Sealing was determined by placing 0.7 &#x3BC;L of 0.1% toluidine blue (TB) in the implant wells before abutment torquing. Implant-abutment samples were placed into 2.0 mL vials containing 0.7 mL of distilled water to maintain the implant-abutment interface submerged. Aliquots of 100 &#x3BC;l of water were retrieved at 1, 3, 6, 24, 48, 72, 96 and 144 hours incubation times for absorbance measurement in a spectrophotometer, and returned for repeated measurements. Two-way ANOVA (p < 0.05) and Tukey\'s test were used. Scanning electron microscopy (SEM) was used for observation of the implant-abutment fit. Results. Groups M, Sv, and T without the CoCr margin resulted in complete release of TB at 1 h, whereas I, S, and B did at 3, 24 and 96 h, respectively. Complete leakage in abutments with the prefabricated marginoccurredat 6 h for S, 24 h for Sv, T and B, and 72 h for M and I. Implant/abutment gaps were observed in all groups. A poorer fit was depicted for groups M and T without the CoCr margin. Conclusions. Complete leakage was observed for all UCLA abutments regardless of the presence of the CoCrmargin. Implant-abutment gaps was observed for all groups.
19

Idealização e desenvolvimento de um dispositivo para avaliação de resistência da interface implante-intermediário protético por meio de ensaios cíclicos de flexão rotativa / Idealization and development of a device for evaluating resistance of implantabutment interface through rotary bending cyclic test

Felipe Ramalho Ferreira 08 April 2010 (has links)
O sucesso da terapia reabilitadora com implantes requer um equilíbrio entre fatores biológicos e mecânicos. Os fatores biológicos são inúmeros, já os mecânicos associam-se à instabilidade da interface implante-intermediário protético. Com base nestas informações, este estudo busca criar um aparelho com o qual será possível avaliar e comparar a resistência e a estabilidade da interface implante-intermediário protético em implantes de diferentes tipos de sistema de conexão e componentes protéticos, após a aplicação de carga simulada, que será realizada por meio de um ensaio dinâmico de fadiga rotacional, também conhecido como flexão rotativa. Para a criação deste aparelho, vários procedimentos com base em princípios de usinagem CNC (Controle Numérico Computadorizado), engenharia elétrica e física foram utilizados. Os futuros testes e resultados, utilizando-se esse aparelho para realizar o ensaio de fadiga, serão publicados em trabalhos futuros. Para o desenvolvimento dos modelos de corpos de prova a serem analisados na máquina de ensaio, foram utilizados implantes do tipo hexágono externo (Neodent) de 3,75mm de diâmetro x 11.5mm de comprimento. Ao término do desenvolvimento, obteve-se um aparelho confiável, resistente e extremamente versátil; podendo-se facilmente variar a carga exercida e a frequência de rotação, sendo assim possível executar inúmeras combinações de ensaios de fadiga. Esse estudo demonstrou a possibilidade e viabilidade de desenvolver um aparelho adequado para realizar um ensaio de fadiga, de pequena dimensão (portátil) e a um custo significativamente inferior do que comprar um aparelho próprio para tal fim. / The success of a rehabilitation therapy with implant fixtures requires a balance between biological and mechanical factors. The biological factors are innumerable, however the mechanics associate it whit instability of the implant-abutment interface. On the basis of these information, the aim of this study is to create a device which it will be possible to evaluate and to compare the resistance and the stability of the implant-abutment interface whith implants of different connection system and abutments, after the simulated load application, that will be carried through a dynamic assay of rotational fatigue load, also known as rotary bending. For the creation of this device, some procedures on the basis of principles of milling CNC (Computerized Numerical control), electric and physical engineering had been used. The future tests and results, using this device to carry through the fatigue assay, will be published in future works. For the development of the body test to be analyzed in the assay machine, implant fixtures of external hexagon type (Neodent) of 3,75mm of diameter x 11mm of length had been used. In the ending of the development, a trustworthy, resistant and extremely versatile device was gotten; being able itself easily to vary the exerted load and the frequency of rotation, being been thus possible to execute innumerable combinations of fatigue assays. This study demonstrated the possibility and viability of it developing an adequate device to carry through an assay of fatigue, of small dimension (portable) and the significantly inferior cost of what if to buy a proper device for such end.
20

Avaliação da capacidade de selamento de intermediários UCLA em um sistema de implante de hexágono externo / Evaluation of UCLA implant-abutment sealing Purpose

Marcelo Barbosa Ramos 28 June 2013 (has links)
Objetivo. Avaliar a capacidade de selamento e a adaptação de intermediários UCLA, com ou sem uma cinta de cobalto-cromo (CoCr), em um sistema de implante de hexágono externo. Materiais e métodos. 120 implantes hexágono externo (Sistema de Implante Nacional - SIN, SP, Brazil) foram dividos em dois grupos (n=60) para receber intermediários UCLA de 6 fabricantes (n=10), com ou sem cinta pré-fabricada de CoCr (n=60). Os intermediários foram fundidos e subdivididos em 12 grupos da seguinte forma: M (Microplant), I (Impladen), S (SIN), Sv (Signo Vinces), T (TitaniumFix), and B (Bionnovation). A capacidade de selamento foi determinada pela colocação de 0.7 &#x3BC;L de azul de toluidina, 0.1% (TB) no espaço interno dos implantes antes do torque nos intermediários. Os espécimes implante-intemediários foram colocados dentro de tubos de 2.0 mL, contendo 0.7 mL de água destilada, a fim de manter a interface implante-intemediário submersa. Amostras de 100 &#x3BC;l foram coletadas após 1, 3, 6, 24, 48, 72, 96 e 144 horas de incubação para medição da absorbância em um espectofotômetro e devolvidos para medidas subsequentes. Para análise estatística, foram empregados o teste ANOVA a dois critérios (p < 0.05) e o teste de Tukey. Microscopia eletrônica de varredura (MEV) foi usado para visualização da adaptação da interface implante-intermediário. Resultados. Os grupos M, Sv, e T sem cinta CoCr apresentaram completa liberação de corante (TB) em 1 h, enquanto que nos grupos I, S, e B, a liberação do corante ocorreu em 3, 24 e 96 h, respectivamente. Para os intermediários com cinta préfabricada, a completa liberação de corante ocorreu em 6 h para o grupo S, em 24 h para os grupos Sv, T e B, e em 72 h para os grupos M e I. Foram observados desajustes na interface implante/intermediário em todos os grupos. Os desajustes mais evidentes foram observados para os grupos M e T, sem cinta de CoCr. Conclusões. A completa liberação de corante foi observada em diferentes períodos de tempo para todos intermediários UCLA, independentemente, da presença ou não da cinta CoCr. Foram observados espaços ou desajustes na interface implante/intermediário em todos os grupos. / To evaluate the effect of the presence of a prefabricated cobalt-chromium (CoCr) margin in a universal castable long abutment (UCLA) in the sealing capability and fit of the implant-abutment mating zone. Materials andmethods. One-hundred and twenty external hexagon implants (SIN, SP, Brazil) were divided in two groups (n=60 each) to receive UCLA abutments from 6 manufacturers (n=10 each) either with or without a CoCr margin (n=60 each). Abutments were cast and 12 groups were formed and named as: M (Microplant), I (Impladen), S (SIN), Sv (Signo Vinces), T (TitaniumFix), and B (Bionnovation). Sealing was determined by placing 0.7 &#x3BC;L of 0.1% toluidine blue (TB) in the implant wells before abutment torquing. Implant-abutment samples were placed into 2.0 mL vials containing 0.7 mL of distilled water to maintain the implant-abutment interface submerged. Aliquots of 100 &#x3BC;l of water were retrieved at 1, 3, 6, 24, 48, 72, 96 and 144 hours incubation times for absorbance measurement in a spectrophotometer, and returned for repeated measurements. Two-way ANOVA (p < 0.05) and Tukey\'s test were used. Scanning electron microscopy (SEM) was used for observation of the implant-abutment fit. Results. Groups M, Sv, and T without the CoCr margin resulted in complete release of TB at 1 h, whereas I, S, and B did at 3, 24 and 96 h, respectively. Complete leakage in abutments with the prefabricated marginoccurredat 6 h for S, 24 h for Sv, T and B, and 72 h for M and I. Implant/abutment gaps were observed in all groups. A poorer fit was depicted for groups M and T without the CoCr margin. Conclusions. Complete leakage was observed for all UCLA abutments regardless of the presence of the CoCrmargin. Implant-abutment gaps was observed for all groups.

Page generated in 0.0832 seconds