• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo clínico randomizado para avaliação da segurança e dos efeitos da estimulação ventricular esquerda unifocal em pacientes com bradiarritmias / Randomized clinical trial for eficaccy, safety and performance of of isoleted left ventricular pacing in patients with bradyarrhythmias

Crevelari, Elizabeth Sartori 31 August 2018 (has links)
Introdução: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda (VE) pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bloqueio atrioventricular e função ventricular esquerda preservada ou pouco alterada, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação ventricular esquerda, utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação ventricular direita em pacientes com indicação de marca-passo (MP) convencional e função ventricular esquerda normal a moderadamente alterada. Métodos: Trata-se de um estudo clínico, randomizado, simples-cego que incluiu pacientes adultos com indicação de MP convencional por bloqueio atrioventricular avançado e função ventricular sistólica >= 0,40. A randomização aleatória (VD vs. VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram a evolução clínica e alterações ecocardiográficas. Foram empregados os testes qui-quadrado, exato de Fisher e teste t de Student para comparação dos desfechos entre os dois grupos, considerando o nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares (P = NS). O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. No grupo VE, entretanto, dos 55 pacientes inicialmente alocados, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Complicações pós-operatórias foram detectadas apenas no grupo VE. A complicação mais frequente foi a estimulação frênica, detectada em 9 (25,7%) pacientes. Durante o período de seguimento do estudo, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do ventrículo esquerdo foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos do grupo VE (P = 0,767). A análise feita pelo Doppler tecidual mostrou que 55,9% dos indivíduos do grupo VD e 43,8% dos do grupo VE apresentaram dissincronia intraventricular ventricular esquerda (P = 0,324). Pelo mesmo método, foi detectado que 91,2% e 68,8% dos pacientes dos grupos VD e VE, respectivamente, apresentavam dissincronia interventricular (P=0,022). Conclusões: A estimulação ventricular esquerda exclusiva, nas condições estudadas, mostrou taxa de sucesso, segurança e eficácia inadequadas. A despeito da melhor sincronia interventricular observada nos pacientes sob estimulação ventricular esquerda, a comparação dos desfechos secundários entre os dois grupos não mostrou diferenças significativas / Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring only the correction of heart rate. Objective: To assess the safety, efficacy and effects of LV pacing using an active-fixation coronary sinus lead compared to RV pacing in patients eligible to conventional pacemaker (PM) implantation. Methods: Randomized, controlled and single-blinded trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs LV) occurred before PM implantation. Procedural success, safety, and efficacy were the main endpoints. Secondary outcomes were clinical and echocardiographic changes. Chi-square, Fisher\'s exact test and Student\'s t test were used, considering a significance level of 5%. Results: From June/2012 to January/2014, 91 patients were included, 36 in the RV group and 55 in the LV group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated to the LV group, the implant of the active-fixation coronary sinus lead was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations for heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and in 20.6% of those in the LV group (P= 0.767). Echo-tissue doppler showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (P= 0.022). Conclusion: Isolated left ventricular pacing, under the conditions studied, showed an inadequate success rate, safety and efficacy. Despite the better interventricular synchrony observed in LV group, the comparison of secondary outcomes between the two groups did not show significant differences
2

Estudo clínico randomizado para avaliação da segurança e dos efeitos da estimulação ventricular esquerda unifocal em pacientes com bradiarritmias / Randomized clinical trial for eficaccy, safety and performance of of isoleted left ventricular pacing in patients with bradyarrhythmias

Elizabeth Sartori Crevelari 31 August 2018 (has links)
Introdução: Considerando-se os potenciais efeitos deletérios da estimulação do ventrículo direito (VD), a hipótese desse estudo é que a estimulação unifocal ventricular esquerda (VE) pelo seio coronário é segura e pode proporcionar melhores benefícios clínicos e ecocardiográficos aos pacientes com bloqueio atrioventricular e função ventricular esquerda preservada ou pouco alterada, necessitando apenas da correção da frequência cardíaca. Objetivos: Avaliar a segurança, a eficácia e os efeitos da estimulação ventricular esquerda, utilizando um cabo-eletrodo com fixação ativa, em comparação à estimulação ventricular direita em pacientes com indicação de marca-passo (MP) convencional e função ventricular esquerda normal a moderadamente alterada. Métodos: Trata-se de um estudo clínico, randomizado, simples-cego que incluiu pacientes adultos com indicação de MP convencional por bloqueio atrioventricular avançado e função ventricular sistólica >= 0,40. A randomização aleatória (VD vs. VE) ocorreu antes do procedimento. Os desfechos primários do estudo foram o sucesso, a segurança e a eficácia do procedimento proposto. Os desfechos secundários foram a evolução clínica e alterações ecocardiográficas. Foram empregados os testes qui-quadrado, exato de Fisher e teste t de Student para comparação dos desfechos entre os dois grupos, considerando o nível de significância de 5%. Resultados: De junho de 2012 a janeiro de 2014 foram incluídos 91 pacientes, sendo 36 no grupo VD e 55 no grupo VE. As características basais dos pacientes dos dois grupos foram similares (P = NS). O implante de MP foi realizado com sucesso e sem nenhuma intercorrência em todos os pacientes do grupo VD. No grupo VE, entretanto, dos 55 pacientes inicialmente alocados, o implante do cabo-eletrodo em veias coronárias não foi possível em 20 (36,4%) pacientes. Complicações pós-operatórias foram detectadas apenas no grupo VE. A complicação mais frequente foi a estimulação frênica, detectada em 9 (25,7%) pacientes. Durante o período de seguimento do estudo, não houve hospitalizações por insuficiência cardíaca. Reduções superiores a 10% na fração de ejeção do ventrículo esquerdo foram observadas em 23,5% dos pacientes do grupo VD e em 20,6% dos do grupo VE (P = 0,767). A análise feita pelo Doppler tecidual mostrou que 55,9% dos indivíduos do grupo VD e 43,8% dos do grupo VE apresentaram dissincronia intraventricular ventricular esquerda (P = 0,324). Pelo mesmo método, foi detectado que 91,2% e 68,8% dos pacientes dos grupos VD e VE, respectivamente, apresentavam dissincronia interventricular (P=0,022). Conclusões: A estimulação ventricular esquerda exclusiva, nas condições estudadas, mostrou taxa de sucesso, segurança e eficácia inadequadas. A despeito da melhor sincronia interventricular observada nos pacientes sob estimulação ventricular esquerda, a comparação dos desfechos secundários entre os dois grupos não mostrou diferenças significativas / Background: Considering the potential deleterious effects of right ventricular (RV) pacing, the hypothesis of this study is that isolated left ventricular (LV) pacing through the coronary sinus is safe and may provide better clinical and echocardiographic benefits to patients with bradyarrhythmias and normal ventricular function requiring only the correction of heart rate. Objective: To assess the safety, efficacy and effects of LV pacing using an active-fixation coronary sinus lead compared to RV pacing in patients eligible to conventional pacemaker (PM) implantation. Methods: Randomized, controlled and single-blinded trial in adult patients submitted to PM implantation due to bradyarrhythmias and systolic ventricular function >= 0.40. Randomization (RV vs LV) occurred before PM implantation. Procedural success, safety, and efficacy were the main endpoints. Secondary outcomes were clinical and echocardiographic changes. Chi-square, Fisher\'s exact test and Student\'s t test were used, considering a significance level of 5%. Results: From June/2012 to January/2014, 91 patients were included, 36 in the RV group and 55 in the LV group. Baseline characteristics of patients in both groups were similar. PM implantation was performed successfully and without any complications in all patients in the RV group. Of the 55 patients initially allocated to the LV group, the implant of the active-fixation coronary sinus lead was not possible in 20 (36.4%) patients. The most frequent complication was phrenic nerve stimulation, detected in 9 (25.7%) patients in the LV group. During the follow-up period, there were no hospitalizations for heart failure. Reductions of more than 10% in left ventricular ejection fraction were observed in 23.5% of patients in the RV group and in 20.6% of those in the LV group (P= 0.767). Echo-tissue doppler showed that 91.2% of subjects in the RV group and 68.8% of those in the LV group had interventricular dyssynchrony (P= 0.022). Conclusion: Isolated left ventricular pacing, under the conditions studied, showed an inadequate success rate, safety and efficacy. Despite the better interventricular synchrony observed in LV group, the comparison of secondary outcomes between the two groups did not show significant differences
3

Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via fossa média em ossos temporais / Evaluation of intra cochlear trauma after cochlear implant electrode insertion through a middle fossa approach in temporal bones

Cisneros Lesser, Juan Carlos 01 February 2017 (has links)
Introdução: O acesso pela via da fossa craniana média para colocação do implante coclear provou ser uma alternativa valiosa em pacientes com otite média crônica e cavidades de mastoidectomia instáveis, cócleas parcialmente ossificadas e em alguns casos de displasia do ouvido interno. Até hoje não existem pesquisas que descrevam se a inserção do feixe de eletrodos pela via da fossa média pode ser feita com um mínimo de traumatismo intracoclear, comparável ao observado nas inserções pela janela redonda. Objetivo: Avaliar o trauma intracoclear com dois modelos distintos de implante quando o feixe de eletrodos é inserido por cocleostomia na fossa craniana média em ossos temporais. Método: 20 ossos temporais retirados antes de 24 horas pós-óbito, foram implantados através do local da cocleostomia no giro basal da cóclea identificado no assoalho da fossa cerebral média. Dez peças receberam um implante reto e dez um pré-curvado, e foram fixadas em resina epóxi. Foi realizada tomografia computadorizada para determinar a colocação adequada do feixe eletrodos, profundidade de inserção e a distância entre a janela redonda e a cocleostomia. Por último, as peças foram polidas em série, tingidas e visualizadas por estereomicroscópio para avaliar a posição do feixe e trauma intracoclear. Resultados: A tomografia mostrou um posicionamento intracoclear do feixe de eletrodos nas 20 peças. No grupo dos implantes retos a média de eletrodos inserido foi 12,3 (10 a 14) e dos pré-curvados 15,1 (14 a 16) com uma diferença significativa (U=78, p=0,0001). A mediana de profundidade de inserção foi maior para o eletrodo pré-curvado (14,5mm) que para o reto (12,5mm) com diferenças estatisticamente significativas (U = 66, p = 0,021). Só uma das 20 inserções foi atraumática e 70% tiveram graus de trauma altos (grau 3 ou 4). Não foram observadas diferenças significativas do grau de trauma entre os dois tipos de feixes nem quando as inserções foram no sentido da janela redonda, comparado com o sentido do giro médio. Conclusões: A técnica cirúrgica utilizada permitiu a inserção do feixe de eletrodos na cóclea em todas as peças, porém sem garantir uma inserção na escala timpânica e com alto risco de trauma nas microestruturas da cóclea / Introduction: In recent years, a middle fossa approach has been described for the insertion of cochlear implants, and it proved to be a reliable alternative for implantation in patients with chronic supurative otitis media, unstable mastoid cavities with recurrent otorrhea, partially ossified cochlea and in some cases of inner ear dysplasia. Until now, no research has been done to describe if this approach allows for anatomic preservation and non-traumatic insertions comparable to those through the round window. Objective: To evaluate cochlear trauma when the cochlear implant electrode is inserted through a middle fossa approach by means of histologic and imaging studies in temporal bones. Methods: 20 temporal bones retrieved before 24 hours after death were implanted through a middle cranial fossa cochleostomy in the basal turn of the cochlea. Ten received a straight electrode and 10 a perimodiolar electrode. After reducing the bone size with preservation of the inner ear structures, the temporal bones were fixed, dehydrated and embedded in an epoxy resin. CT scans were performed to determine if an adequate direction of insertion was attained, the depth of insertion and the distance between the cochleostomy and the round window. At last, the samples were polished by micro-grinding technique and microscopically visualized to evaluate intracochlear trauma. Results: The CT-scan showed an adequate intracoclear position of the electrode in all the samples. In the straight electrode group the average number of inserted electrodes was 12.3 (10 to 14) against 15.1 (14- 16) for the perimodiolar (U=78, p=0.0001). The median depth of insertion was significantly larger for the perimodiolar electrode group (14.4mm vs. 12.5mm U=66, p = 0.021). Only one atraumatic insertion was achieved and 70% of the samples had important trauma (grades 3 and 4). No differences were identified for the trauma grades between the two groups of electrodes. Also, there were no differences in trauma if the cochlear implants were inserted in the direction of the basal turn of the cochlea or in the direction of the middle and apical turns. Conclusions: The surgical technique that was used allowed for a proper intracochlear insertion of the electrodes in all 20 temporal bones but it does not guarantee a correct scala tympani position and carries high trauma risk for the intracochlear microstructures
4

Avaliação do trauma intracoclear causado pela inserção do feixe de eletrodos do implante coclear via fossa média em ossos temporais / Evaluation of intra cochlear trauma after cochlear implant electrode insertion through a middle fossa approach in temporal bones

Juan Carlos Cisneros Lesser 01 February 2017 (has links)
Introdução: O acesso pela via da fossa craniana média para colocação do implante coclear provou ser uma alternativa valiosa em pacientes com otite média crônica e cavidades de mastoidectomia instáveis, cócleas parcialmente ossificadas e em alguns casos de displasia do ouvido interno. Até hoje não existem pesquisas que descrevam se a inserção do feixe de eletrodos pela via da fossa média pode ser feita com um mínimo de traumatismo intracoclear, comparável ao observado nas inserções pela janela redonda. Objetivo: Avaliar o trauma intracoclear com dois modelos distintos de implante quando o feixe de eletrodos é inserido por cocleostomia na fossa craniana média em ossos temporais. Método: 20 ossos temporais retirados antes de 24 horas pós-óbito, foram implantados através do local da cocleostomia no giro basal da cóclea identificado no assoalho da fossa cerebral média. Dez peças receberam um implante reto e dez um pré-curvado, e foram fixadas em resina epóxi. Foi realizada tomografia computadorizada para determinar a colocação adequada do feixe eletrodos, profundidade de inserção e a distância entre a janela redonda e a cocleostomia. Por último, as peças foram polidas em série, tingidas e visualizadas por estereomicroscópio para avaliar a posição do feixe e trauma intracoclear. Resultados: A tomografia mostrou um posicionamento intracoclear do feixe de eletrodos nas 20 peças. No grupo dos implantes retos a média de eletrodos inserido foi 12,3 (10 a 14) e dos pré-curvados 15,1 (14 a 16) com uma diferença significativa (U=78, p=0,0001). A mediana de profundidade de inserção foi maior para o eletrodo pré-curvado (14,5mm) que para o reto (12,5mm) com diferenças estatisticamente significativas (U = 66, p = 0,021). Só uma das 20 inserções foi atraumática e 70% tiveram graus de trauma altos (grau 3 ou 4). Não foram observadas diferenças significativas do grau de trauma entre os dois tipos de feixes nem quando as inserções foram no sentido da janela redonda, comparado com o sentido do giro médio. Conclusões: A técnica cirúrgica utilizada permitiu a inserção do feixe de eletrodos na cóclea em todas as peças, porém sem garantir uma inserção na escala timpânica e com alto risco de trauma nas microestruturas da cóclea / Introduction: In recent years, a middle fossa approach has been described for the insertion of cochlear implants, and it proved to be a reliable alternative for implantation in patients with chronic supurative otitis media, unstable mastoid cavities with recurrent otorrhea, partially ossified cochlea and in some cases of inner ear dysplasia. Until now, no research has been done to describe if this approach allows for anatomic preservation and non-traumatic insertions comparable to those through the round window. Objective: To evaluate cochlear trauma when the cochlear implant electrode is inserted through a middle fossa approach by means of histologic and imaging studies in temporal bones. Methods: 20 temporal bones retrieved before 24 hours after death were implanted through a middle cranial fossa cochleostomy in the basal turn of the cochlea. Ten received a straight electrode and 10 a perimodiolar electrode. After reducing the bone size with preservation of the inner ear structures, the temporal bones were fixed, dehydrated and embedded in an epoxy resin. CT scans were performed to determine if an adequate direction of insertion was attained, the depth of insertion and the distance between the cochleostomy and the round window. At last, the samples were polished by micro-grinding technique and microscopically visualized to evaluate intracochlear trauma. Results: The CT-scan showed an adequate intracoclear position of the electrode in all the samples. In the straight electrode group the average number of inserted electrodes was 12.3 (10 to 14) against 15.1 (14- 16) for the perimodiolar (U=78, p=0.0001). The median depth of insertion was significantly larger for the perimodiolar electrode group (14.4mm vs. 12.5mm U=66, p = 0.021). Only one atraumatic insertion was achieved and 70% of the samples had important trauma (grades 3 and 4). No differences were identified for the trauma grades between the two groups of electrodes. Also, there were no differences in trauma if the cochlear implants were inserted in the direction of the basal turn of the cochlea or in the direction of the middle and apical turns. Conclusions: The surgical technique that was used allowed for a proper intracochlear insertion of the electrodes in all 20 temporal bones but it does not guarantee a correct scala tympani position and carries high trauma risk for the intracochlear microstructures

Page generated in 0.0998 seconds