• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] METROLOGICAL TRACEABILITY OF ELECTRICAL CURRENT IMPULSES IN BRAZIL / [pt] RASTREABILIDADE METROLÓGICA DE IMPULSOS DE CORRENTE ELÉTRICA NO BRASIL

LUCAS CASTRO FARIA 12 March 2019 (has links)
[pt] O para-raios é o principal equipamento de proteção dos transformadores e linhas de transmissão de energia, que estão presentes em todo território nacional, protegendo-os de descargas atmosféricas e sobretensão, evitando grandes perdas de equipamentos e um custo relativamente alto para as concessionárias de energia. O para-raios precisa obter conformidade e certificação em relação à qualidade do material e a suas características de proteção, e um dos ensaios de verificação de desempenho baseia-se na resposta ao impulso de corrente. Contudo, para a realização destes ensaios de desempenho é necessário que haja um sistema de medição acreditado, apto a realizá-los com precisão e rastreabilidade aos padrões de transdutores, ou seja, com níveis de incerteza dentro dos limites aceitáveis, segundo a norma IEC 62475:2010. O Inmetro, que é o Instituto Nacional de Metrologia do Brasil, ainda não possui um Sistema de Medição de Referência (SMR) que possa ser empregado na fiscalização e acreditação de laboratórios que venham a exercer a função de Sistema de Medição Aprovado (SMA), levando a rastreabilidade e conformidade aos padrões de transdutores de corrente elétrica, de modo a produzir equipamentos com confiabilidade e segurança. Assim, essa dissertação faz um levantamento dos níveis de rastreabilidade e um estudo normativo e estrutural de ensaios de impulso de corrente, à luz da norma IEC 62475:2010. / [en] The surge arrester is the main protection equipment of the power transformers and power transmission lines, which are present throughout the country, protecting them from lightnings and overvoltage, avoiding large equipment failures and a relatively high cost for the power companies. The arrester must obtain conformity and certification regarding the quality of the material and its safety features, and one of the performance verification tests is based on the response to current impulses. However, to realize these performance tests it is necessary to have a measurement system accredited to perform this type of test, with accuracy and traceability of the standard transducers, that is, uncertainty levels within acceptable limits according to IEC 62475:2010. The Brazilian National Institute of Metrology ( INMETRO) does not have a Reference Measuring System (RMS) that can be used in the inspection and accreditation of laboratories that will perform as a Approved Measuring System, giving traceability and conformity to the electrical current transducers standards (Shunts or CTs), so as to produce reliable and safe equipments. Thus, this dissertation surveys the traceability levels and the normative and structural landscape regadring current impulse tests based on IEC 62475:2010.
2

Análise de sistemas de aterramento com hastes concretadas submetidos a correntes impulsivas.

BEZERRA, Gabriel Vidal Negreiros. 25 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-25T17:58:53Z No. of bitstreams: 1 GABRIEL VIDAL NEGREIROS BEZERRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 5032226 bytes, checksum: 900940f480110db5450f19583af7d19d (MD5) / Made available in DSpace on 2018-04-25T17:58:53Z (GMT). No. of bitstreams: 1 GABRIEL VIDAL NEGREIROS BEZERRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 5032226 bytes, checksum: 900940f480110db5450f19583af7d19d (MD5) Previous issue date: 2017-03-30 / CNPq / Neste trabalho é realizada uma avaliação da resposta impulsiva de aterramento com haste concretada, considerando o efeito da ionização do solo. Para isso, o aterramento foi representado e simulado utilizando uma ferramenta computacional de simulação em três dimensões por meio do método dos elementos finitos. A representação computacional, bem como a validação da mesma, foi feita tomando-se como base dados experimentais apresentados na literatura. O fenômeno da ionização do solo foi implementado ponto a ponto, utilizando o equacionamento do modelo dinâmico de ionização do solo, possibilitando que aterramentos com diferentes formatos geométricos sejam avaliados. Avaliou-se a impedância transitória de uma haste concretada padronizada para solos com diferentes resistividades. Além disso, procedeu-se com uma análise da resposta impulsiva da haste concretada para diferentes parâmetros geométricos, a saber: raio do concreto envolvente, comprimento vertical da haste concretada, comprimento vertical do concreto envolvente e profundidade da haste concretada em relação ao nível do solo. Por fim, propõem-se limites práticos e sugestões de dimensões para a haste concretada, de forma que a reposta impulsiva seja otimizada. / In this research, was performed an impulsive response evaluation of concrete encased groundings, considering de soil ionization effect. In order to achive this, the grouding was represented and simulated in three dimensions using a finite element method software. The computational representation and validation were performed using experimental data presented in the literature. The soil ionization effect was implemented in a point form, allowing evaluate groudings with different geometric formats. It was studied the transient impedance of a standard concrete encased rod placed in soils with different resistivity values. Furthermore, was performed a transient response analysis for different geometric parameters of the concrete encased rod, namely: the concrete radius, the vertical length of the concrete encased rod, the vertical length of the concrete encased rod, the surrounding concrete and the depth of the concrete encased rod in relation to the soil surface. Finally, practical limits and suggested dimensions for the concrete encased rod are proposed, in order to optimize the impulse response.

Page generated in 0.0821 seconds