• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 34
  • 2
  • Tagged with
  • 81
  • 58
  • 36
  • 32
  • 31
  • 31
  • 17
  • 14
  • 11
  • 11
  • 10
  • 10
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

DEVELOPPEMENT INDUSTRIEL D'UNE PLATE-FORME PROTOTYPE : APPLICATIONS AU TRAITEMENT DE SURFACES ET A LA STERILISATION PAR PLASMAS FROIDS

Berthout, Guillaume 30 October 2002 (has links) (PDF)
L'objectif de ce projet porte sur le développement d'applications industrielles dans le domaine des traitements de surface par plasmas froids. L'emploi de cette technique pour le traitement de surface polymère reste de manière générale une alternative intéressante à la voie chimique. La création d'un réacteur prototype de grand volume répond aux attentes très diverses des industriels. Par son caractère évolutif, la plate-forme plasma froid du CRITT est un véritable outil de recherche dédié à l'industrie. Un des thèmes émergents de ces dernières années concerne l'utilisation des plasmas froids comme moyen alternatif pour la stérilisation des dispositifs médicaux. En effet, les techniques conventionnelles ne permettent pas une inactivation performante de certains micro-organismes pathogènes et les conditions de traitement parfois extrêmes n'assurent pas la pérennité du matériel médical. Préalablement à une validation clinique nécessaire à son développement en milieu industriel ou médical, ce nouveau procédé doit naturellement faire la preuve de son efficacité. L'étude réalisée présente les principaux mécanismes susceptibles d'expliquer l'inactivation d'un micro-organisme exposé au plasma. L'action en synergie de photons UV et d'espèces actives comme l'oxygène atomique confère à cette technologie une cinétique d'inactivation particulière. La production de ces agents actifs est optimisée par un diagnostic du plasma en spectroscopie optique, permettant ainsi d'atteindre des degrés d'inactivation très prometteurs. Même si l'efficacité du plasma n'est plus à démontrer, la problématique du conditionnement, qui fait partie intégrante d'un procédé, se pose toujours en milieu industriel. L'inhibition du plasma diffusant à travers un sachet poreux ne permet pas d'obtenir l'état stérile. Une solution consistant à générer un plasma induit dans un sachet, assurant ainsi un contact intime entre les espèces actives du plasma et le dispositif à stériliser, est donc discutée.
2

Stratégie d'échantillonnage des mesures LIBS in situ de la teneur en or dans des échantillons miniers : optimisation par analyse statistique

Nguegang Kamwa, Blandine 31 May 2021 (has links)
Au Québec, 19 mines d'or produisent plus de 1.8 milliard dollars canadiens d'or annuellement. Dans ces mines, des centaines d'échantillons de roches sont collectées quotidiennement, et envoyées au laboratoire afin de déterminer leurs concentrations en or. Étant donné que les résultats du laboratoire ne sont disponibles qu'après 24 à 48 heures, il s'en suit un impact direct négatif sur les activités minières. Les avancées technologiques des dernières années laissent croire que la spectroscopie sur plasma induite par laser (LIBS) pourrait constituer une technologie prometteuse pour mesurer en temps réel et in-situ, la teneur en or de la roche. Considérant la taille de chaque tir produit par le laser sur un échantillon de roche, à savoir 500 µm, de très nombreux tirs seront requis afin d'obtenir un résultat représentatif de l'échantillon analysé. À titre d'exemple, pour un échantillon de carotte de 50 cm de long, et une surface analysée comprise entre 70 et 80%, 10000 tirs lasers ont été effectués afin de s'assurer d'obtenir un résultat représentatif de l'échantillon, avec un temps d'acquisition d'une demi-journée en laboratoire, soit une durée trop longue pour une application pratique dans les mines. Pour cette raison, l'objectif de ce projet est de développer une stratégie afin de minimiser le nombre de tirs LIBS requis sur un échantillon à analyser, tout en demeurant représentatif de ce dernier, et ainsi obtenir une mesure fiable et précise de la teneur en or. Pour ce faire, une analyse statistique descriptive combinée à plusieurs motifs élaborés à partir des 10000 points de mesure est appliquée sur les données LIBS. En se fixant un compromis entre le nombre de tirs à réaliser sur un échantillon (roche) et le temps d'analyse, le motif défini « Boucle » minimise le mieux le nombre de tirs avec un temps d'analyse acceptable par une opération minière. À partir de ce dernier, un protocole d'échantillonnage a été élaboré, où pour être représentatif des échantillons de carottes, 1500 tirs sont nécessaires tandis que pour les échantillons de roches, seuls 100 tirs suffisent. Cependant, il serait important de pouvoir tester ce protocole d'échantillonnage sur plusieurs échantillons miniers afin de pouvoir valider ce dernier. / In Quebec, 19 gold mines produce more than C (dollar) 1.8 billion of gold annually. In these mines, hundreds of rock samples are collected daily and sent to the laboratory to determine their gold concentrations. Since laboratory results are only available after 24 to 48 hours, there is a direct negative impact on mining activities. Technological advances in recent years suggest that Laser Induced Breakdown Spectroscopy (LIBS) may be a promising technology for real-time and in-situ measurement of the gold content of rock samples. Considering the size of each shot produced by the laser on a rock sample, namely 500 µm, many shots will be required in order to obtain a representative result of the sample analyzed. For example, for a 50 cm long core sample, and a surface analyzed between 70 and 80%, 10,000 laser shots were fired to ensure to obtain a result representative of the sample, with an acquisition time of half a day in the laboratory, which is a too long period of time for a practical application in mines. For this reason, the objective of this project is to minimize the number of LIBS shots required on a sample to be analyzed, while remaining representative of the latter, and thus obtain a reliable and accurate measurement of the gold content. For this, a descriptive statistical analysis combined with several elaborate patterns is applied to the 10,000 LIBS data obtained. By setting a compromise between the number of shots to be made on a sample and the analysis time, the Loop pattern minimizes the number of shots with an acceptable analysis time. From the latter, a sampling protocol has been developed, where to be representative of core samples, 1500 shots are needed whereas for rock samples, only 100 shots are needed. However, it would be important to be
3

Application of femtosecond filamentation in gaseous media / Application of femtosecond filamentation in gaseous media

Hosseini, Sima, Hosseini, Sima January 2019 (has links)
Cette thèse décrit plusieurs résultats expérimentaux impliquant le phénomène de la filamentation laser qui se produit lorsque des impulsions laser ultrabrèves se progagent dans l'air avec une intensité de l'ordre de ~ 10¹³ W/cm2. Un laser titane-saphir est utilisé pour gé- nérer des impulsions femtosecondes dans l'infrarouge (800 nm). En raison de ses propriétés particulières, cette forme de propagation est étudiée pour de nombreuses applications. Nous nous concentrons dans cette thèse sur la télédétection et l'identification de polluants atmosph ériques. Notre objectif est d'améliorer les résultats et de résoudre certains problèmes dans la détection de polluants, en particulier de ceux qui ont le même spectre de fluorescence induit par filamentation. Tous les résultats présentés ici ont été obtenus en laboratoire. La télédétection de polluants dans l'atmosphère implique la propagation de filaments à haute altitude où la pression atmosphérique est basse. Il est donc important de bien comprendre le phénomène de la filamentation dans ces conditions. Nous avons expérimentalement et numériquement étudié l'effet d'une basse pression sur un filament unique dans l'air. Les expériences furent réalisées en variant la pression à l'intérieur d'une cellule entre 0,3 et 1 fois la pression atmosphérique normale (1 atm ~ 1:01 X 10⁵ Pa). Une approche pour détecter à distance la présence de polluants atmosphériques est de capter la fluorescence émise par les fragments moléculaires créés lors du passage de l'impulsion laser. Ce signal est toutefois lourdement atténué avant d'atteindre le détecteur en raison de la grande distance de propagation dans ces applications et il est important de trouver des moyens pour augmenter le signal de fluorescence. Nous avons donc étudié la possibilité d'utiliser le filament lui-même comme milieu de gain dans la direction de propagation pour amplifier les émissions des impuretés de l'air. Il avait déjà été démontré qu'un filament peut amplifier le signal rétrodiffusé dans l'air pur alors nous avons débuté nos expériences dans l'air pour ensuite étudier des mélanges air-hydrocarbones ( 2% de CH₄, C₂H₂ et C₂H₄ dans l'air). Nous avons détecté la fluorescence émise par l'azote neutre à ~ 337 nm dans l'air pur et par les fragments CH à ~ 431 nm dans des mélanges air-hydrocarbones. Dans les deux cas, le signal de fluorescence émis dans la direction opposée à celle du laser a augmenté de manière nonlin éaire en fonction de la longueur du filament, tandis que celui émis sur les côtés montrait une tendance linéaire. Le dernier chapitre de cette thèse traite d'une nouvelle approche pour identifier les molé- cules basée sur leur alignement. Nous montrons en effet que des polluants dans l'air peuvent être détectés et identifiés en mesurant les constantes de rotation de diférentes molécules. Il est important de noter que cette technique permet de distinguer des polluants dont les fragments émettent le même spectre de fluorescence (les mêmes raies atomiques et bandes moléculaires). Les résultats présentés dans cette thèse ont été obtenus par des études de type pompe-sonde utilisant le signal diffusé de l'impulsion de sonde, contrairement à d'autres expériences qui détectent la lumière transmise. Le fait d'observer le signal diffusé plutôt que celui transmis rend cette technique pertinente pour des applications de télédétection. Même si les molécules dans un gaz sont orientées de façon aléatoire, une impulsion ultrabrève et intense peut forcer les molécules à s'aligner non seulement pendant le passage de l'impulsion mais aussi après. Plus spécifiquement, un paquet d'onde rotationnel peut être créé par une impulsion femtoseconde, ce qui génère un alignement moléculaire en l'absence de champ après le passage de l'impulsion qui peut se reformer à intervalles réguliers. En plus de permettre la détermination des constantes de rotation et l'identication des molécules, cette technique donne également accès à des informations sur la dissipation dans le milieu en étudiant l'évolution du paquet d'onde sur une longue période (plusieurs retours périodiques de l'alignement moléculaire) après le passage de l'impulsion. / Cette thèse décrit plusieurs résultats expérimentaux impliquant le phénomène de la filamentation laser qui se produit lorsque des impulsions laser ultrabrèves se progagent dans l'air avec une intensité de l'ordre de ~ 10¹³ W/cm2. Un laser titane-saphir est utilisé pour gé- nérer des impulsions femtosecondes dans l'infrarouge (800 nm). En raison de ses propriétés particulières, cette forme de propagation est étudiée pour de nombreuses applications. Nous nous concentrons dans cette thèse sur la télédétection et l'identification de polluants atmosph ériques. Notre objectif est d'améliorer les résultats et de résoudre certains problèmes dans la détection de polluants, en particulier de ceux qui ont le même spectre de fluorescence induit par filamentation. Tous les résultats présentés ici ont été obtenus en laboratoire. La télédétection de polluants dans l'atmosphère implique la propagation de filaments à haute altitude où la pression atmosphérique est basse. Il est donc important de bien comprendre le phénomène de la filamentation dans ces conditions. Nous avons expérimentalement et numériquement étudié l'effet d'une basse pression sur un filament unique dans l'air. Les expériences furent réalisées en variant la pression à l'intérieur d'une cellule entre 0,3 et 1 fois la pression atmosphérique normale (1 atm ~ 1:01 X 10⁵ Pa). Une approche pour détecter à distance la présence de polluants atmosphériques est de capter la fluorescence émise par les fragments moléculaires créés lors du passage de l'impulsion laser. Ce signal est toutefois lourdement atténué avant d'atteindre le détecteur en raison de la grande distance de propagation dans ces applications et il est important de trouver des moyens pour augmenter le signal de fluorescence. Nous avons donc étudié la possibilité d'utiliser le filament lui-même comme milieu de gain dans la direction de propagation pour amplifier les émissions des impuretés de l'air. Il avait déjà été démontré qu'un filament peut amplifier le signal rétrodiffusé dans l'air pur alors nous avons débuté nos expériences dans l'air pour ensuite étudier des mélanges air-hydrocarbones ( 2% de CH₄, C₂H₂ et C₂H₄ dans l'air). Nous avons détecté la fluorescence émise par l'azote neutre à ~ 337 nm dans l'air pur et par les fragments CH à ~ 431 nm dans des mélanges air-hydrocarbones. Dans les deux cas, le signal de fluorescence émis dans la direction opposée à celle du laser a augmenté de manière nonlin éaire en fonction de la longueur du filament, tandis que celui émis sur les côtés montrait une tendance linéaire. Le dernier chapitre de cette thèse traite d'une nouvelle approche pour identifier les molé- cules basée sur leur alignement. Nous montrons en effet que des polluants dans l'air peuvent être détectés et identifiés en mesurant les constantes de rotation de diférentes molécules. Il est important de noter que cette technique permet de distinguer des polluants dont les fragments émettent le même spectre de fluorescence (les mêmes raies atomiques et bandes moléculaires). Les résultats présentés dans cette thèse ont été obtenus par des études de type pompe-sonde utilisant le signal diffusé de l'impulsion de sonde, contrairement à d'autres expériences qui détectent la lumière transmise. Le fait d'observer le signal diffusé plutôt que celui transmis rend cette technique pertinente pour des applications de télédétection. Même si les molécules dans un gaz sont orientées de façon aléatoire, une impulsion ultrabrève et intense peut forcer les molécules à s'aligner non seulement pendant le passage de l'impulsion mais aussi après. Plus spécifiquement, un paquet d'onde rotationnel peut être créé par une impulsion femtoseconde, ce qui génère un alignement moléculaire en l'absence de champ après le passage de l'impulsion qui peut se reformer à intervalles réguliers. En plus de permettre la détermination des constantes de rotation et l'identication des molécules, cette technique donne également accès à des informations sur la dissipation dans le milieu en étudiant l'évolution du paquet d'onde sur une longue période (plusieurs retours périodiques de l'alignement moléculaire) après le passage de l'impulsion. / This thesis presents experimental results obtained during filamentation of ultrashort and intense laser pulses, with an intensity of ~ 10¹³ W/cm2 in air. A femtosecond Ti:Sapphire laser was used to generate pulses in the infrared at 800 nm. Because of some unique features of the filaments, this particular form of propagation has been considered for many applications. In this work, we focus our attention on remote sensing and the detection and identification of atmospheric pollutants. The goal is to improve the results and resolve some problems in the detection of air pollutants, especially those with the same filament-induced fluorescence spectrum. The presented experiments were performed inside a laboratory. The remote sensing of pollutants in the atmosphere mainly relies on the propagation of filaments at high altitude where the pressure is low. For this application, it is therefore important to have a good understanding of filamentation in these real conditions. We experimentally and numerically studied the effect of lowering the pressure on a single filament in air. The experiment was done by varying air pressure inside a cell between 0.3 and 1 standard atmospheric pressure (1 atm ~ 1:01 X 10⁵ Pa). One way to remotely detect atmospheric pollutants is to record the returning fluorescence signal from the molecular fragments that are created during filamentation. Because the propagation distance is large in these spectroscopic experiments, the signal is heavily attenuated before reaching the detector and it is important to look for a solution to enhance the fluorescence signal. We therefore investigated the possibility of using the filament itself as a gain medium along the propagation direction to amplify the emission of some impurities in air. It is known that the femtosecond laser filament can amplify backward-directed signal in pure air, so we started our experiments in air, and then extended them to air-hydrocarbons mixtures (2% de CH₄, C₂H₂ et C₂H₄ dans l'air). The fluorescence emission from neutral nitrogen at ~ 337 nm in pure air and from CH fragments at ~ 431 nm in air-hydrocarbons mixtures was detected. In both cases, the fluorescence signal emitted in the direction opposed to the laser propagation increased nonlinearly with the filament length, unlike the emission directed on the sides which showed a linear trend. The last chapter of the thesis introduces a new way to identify molecules that relies on their alignment. Indeed by measuring the rotational constants of different molecules using iv eld-free molecular alignment, we show that pollutants can be detected and identied in air. It is important to mention that this approach can distinguish pollutants for which the excited fragments have the same fluorescence spectra (same atomic lines and molecular bands). The results reported in this thesis were obtained by a pump-probe experiment where the scattered signal of the probe pulse was detected, as opposed to other experiments which collected the transmitted light. Observing the scattered signal instead of the transmitted one makes this technique appropriate for remote sensing applications. Even though molecules are randomly oriented in the gas phase, it is shown that ultrafast intense laser pulses can force molecules to align both in the presence of the laser feld as well as after the passage of the pulse. More specifically, a rotational wavepacket can be created by an ultrashort laser pulse, leading to a feld-free alignment of the molecules after the laser pulse has passed which can revive at regular intervals. Therefore, in addition to finding rotational constants and identifying molecules, it is possible to extract information about the dissipative medium by studying the changes in the wavepacket a long time (several periodic revivals of molecular alignment) after the passage of the pulse. / This thesis presents experimental results obtained during filamentation of ultrashort and intense laser pulses, with an intensity of ~ 10¹³ W/cm2 in air. A femtosecond Ti:Sapphire laser was used to generate pulses in the infrared at 800 nm. Because of some unique features of the filaments, this particular form of propagation has been considered for many applications. In this work, we focus our attention on remote sensing and the detection and identification of atmospheric pollutants. The goal is to improve the results and resolve some problems in the detection of air pollutants, especially those with the same filament-induced fluorescence spectrum. The presented experiments were performed inside a laboratory. The remote sensing of pollutants in the atmosphere mainly relies on the propagation of filaments at high altitude where the pressure is low. For this application, it is therefore important to have a good understanding of filamentation in these real conditions. We experimentally and numerically studied the effect of lowering the pressure on a single filament in air. The experiment was done by varying air pressure inside a cell between 0.3 and 1 standard atmospheric pressure (1 atm ~ 1:01 X 10⁵ Pa). One way to remotely detect atmospheric pollutants is to record the returning fluorescence signal from the molecular fragments that are created during filamentation. Because the propagation distance is large in these spectroscopic experiments, the signal is heavily attenuated before reaching the detector and it is important to look for a solution to enhance the fluorescence signal. We therefore investigated the possibility of using the filament itself as a gain medium along the propagation direction to amplify the emission of some impurities in air. It is known that the femtosecond laser filament can amplify backward-directed signal in pure air, so we started our experiments in air, and then extended them to air-hydrocarbons mixtures (2% de CH₄, C₂H₂ et C₂H₄ dans l'air). The fluorescence emission from neutral nitrogen at ~ 337 nm in pure air and from CH fragments at ~ 431 nm in air-hydrocarbons mixtures was detected. In both cases, the fluorescence signal emitted in the direction opposed to the laser propagation increased nonlinearly with the filament length, unlike the emission directed on the sides which showed a linear trend. The last chapter of the thesis introduces a new way to identify molecules that relies on their alignment. Indeed by measuring the rotational constants of different molecules using iv eld-free molecular alignment, we show that pollutants can be detected and identied in air. It is important to mention that this approach can distinguish pollutants for which the excited fragments have the same fluorescence spectra (same atomic lines and molecular bands). The results reported in this thesis were obtained by a pump-probe experiment where the scattered signal of the probe pulse was detected, as opposed to other experiments which collected the transmitted light. Observing the scattered signal instead of the transmitted one makes this technique appropriate for remote sensing applications. Even though molecules are randomly oriented in the gas phase, it is shown that ultrafast intense laser pulses can force molecules to align both in the presence of the laser feld as well as after the passage of the pulse. More specifically, a rotational wavepacket can be created by an ultrashort laser pulse, leading to a feld-free alignment of the molecules after the laser pulse has passed which can revive at regular intervals. Therefore, in addition to finding rotational constants and identifying molecules, it is possible to extract information about the dissipative medium by studying the changes in the wavepacket a long time (several periodic revivals of molecular alignment) after the passage of the pulse. / Filamentation laser / Filamentation laser
4

Développement d’un système analytique pour la datation in situ des roches martiennes par la méthode K-Ar / Development of a K-Ar dating instrument for in situ measurement of the martian rocks

Devismes, Damien 08 November 2013 (has links)
Sur Mars, la datation par comptage de densité de cratères est actuellement la seule méthode utilisée pour dater les surfaces planétaires. Cependant, sur Mars, elle n’a pas encore été corrigé et complété par des datations absolues. Ce travail consiste à développer un prototype démontrant le potentiel d’une nouvelle approche expérimentale basée sur la méthode K-Ar pour dater les roches martiennes in situ. L’objectif à terme est de proposer une solution instrumentale de datation absolue pour un futur rover d’exploration.Un laser Nd :YAG quadruplé pour tirer à 266 nm ablate un échantillon basaltique mis sous vide secondaire. L’observation du plasma par « Laser Induced Breakdown Spectroscopy » apporte des informations sur la concentration en K et sur la nature chimique et minéralogique de la cible. Puisque l’ablation est faite par un laser UV et sous vide secondaire, l’ablation est reproductible par minéralogie. La reconnaissance stoechiométrique permet donc d’estimer la masse vaporisée. Après purification des gaz libérés, un spectromètre de masse quadripolaire détermine la quantité d’argon.L’ensemble de ces mesures pourvoit un âge avec une incertitude théorique de 13% dans les meilleures conditions.Les calibrations du dispositif expérimental ont apporté de nombreuses informations sur des effets sur les spectres LIBS provoqués par l’ablation sous vide secondaire. L’augmentation de la pression e tla variation de géométrie du cratère d’ablation ont des effets opposés sur les pics des éléments.Nous avons aussi démontré que l’instrument était capable de mesurer l’âge de la mésostase de roche basaltique et qu’il offre des perspectives intéressantes sur certaines phases minérales comme la biotite. / Crater counting is the only method used on Mars to give relative geochronological information but it never had been fitted and corrected by absolute geochronology. This work is about the development of a new prototype demonstrating the ability of a protocol using in situ K-Ar dating. The goal is to propose a solution of an absolute geochronology for the next explorations rovers. A quadrupled Nd:YAG laser at 266 nm ablates a basaltic sample under high vacuum. The light collection by a spectrometer (Laser Induced Breakdown Spectroscopy) gives the rate of potassium and the chemical or the mineralogy of the target. Thanks to the specificities of the ablation in highvacuum and with a UV laser, the ablated mass has a good reproducibility per mineralogy. Thus, theLIBS identification gives an estimation of the ablated mass. After the purification of the released gas,a quadrupole mass spectrometer determines the quantity of argon. All these measures give an age with a theoretical uncertainty of 13% in the best conditions.The calibration of the experiment had given new information about the effects on LIBS spectrarelated to the ablation under high vacuum. The rise of the pressure and the variation of geometry of the pit have opposite effects on the elements peaks. We also demonstrated that the instrument was capable of measuring the age of the groundmass of basalt and has some interesting perspectives on some mineral phases such as biotite.
5

Caractérisation de la composition et de la structure des alliages argent-cuivre par ICP-MS avec prélèvement par ablation laser : application au monnayage carolingien /

Sarah, Guillaume. January 2008 (has links)
Thèse de Doctorat--Chimie--Université d'Orléans, Ecole doctorale Sciences et technologies, Centre Ernest Babelon, Institut de recherche sur les archéométaux, 2008. / Bibliogr. p. 211.
6

Développement et applications d'un système laser femtoseconde infra-rouge basse énergie et haute cadence de tir pour l'analyse d'éléments trace dans les solides par couplage ablation laser / ICPMS.

Claverie, Fanny Donard, Olivier January 2009 (has links) (PDF)
Reproduction de : Thèse doctorat : Environnement et matériaux : Pau : 2009. / Titre provenant de l'écran titre.
7

Contribution à l'analyse et à la modéllisation des couplages électromagnétiques au sein de torons de câbles à grand nombre de liaisons : application aux câblages aéronautiques

Jullien, Charles 12 February 2013 (has links) (PDF)
Cette thèse porte sur l'analyse et la modélisation des interactions électromagnétiques sur des torons aéronautiques constitués de câbles multiconducteurs représentatifs de la réalité industrielle. En effet les évolutions technologiques (introduction de matériaux composites, augmentation des fonctions électriques,..) conduisent à revoir les niveaux d'exigence des couplages électromagnétiques sur torons de câbles. Ainsi, les outils de dimensionnement de ces couplages s'avèrent indispensables pour décider des choix technologiques d'architectures des câblages.Dans ce contexte, les codes numériques basés sur la théorie des lignes de transmission permettent de calculer les couplages électromagnétiques au sein de torons multiconducteurs. Ces modèles numériques doivent être alimentés par la description géométrique des sections droites de toron. Un outil logiciel de génération de sections droites de toron a étévalidé dans un premier temps par comparaison à une référence bibliographique, puis par une étude expérimentale d'un toron réel d'A380. Cette étude de suivi de positionnement de conducteur dans le toron a mis en évidence que le cheminement des câbles au sein du toron dépendait de leur rigidité. Ainsi, la bifilaire torsadée non blindée est le câble dont le cheminement est le moins maîtrisé. De plus, ce type de câble très couramment utilisé pour transmettre desdonnées en mode différentiel, est à l'origine de couplages spécifiques qu'il est essentiel d'analyser pour correctement les modéliser. Par conséquent, le premier cas étudié est composé d'une bifilaire torsadée agresseur et d'une monofilaire victime. Les simulations numériques ont montré que les courants induits le long de la monofilaire victime présentaient un motif propre à la torsade de la bifilaire agresseur. Ce motif a été expliqué par une approche analytique et confirmé par expérimentations. La prise en compte des torsades dans une simulation numérique induisant des temps de calculs prohibitifs, un modèle simplifié de câble torsadé basé sur un moyennage des paramètres linéiques a été développé et validé. L'effet des extrémités dé-torsadées résultant de la connectorisation a également été évalué d'un point de vue numérique et expérimental. Les cas d'étude ont ensuite été complexifiés à des couplages entre bifilaires torsadées jusqu'à traiter un toron réel de plus de 60 conducteurs. Un banc expérimental a été développé. La modélisation numérique de ce toron complexe a été réalisée et les résultats numériques de couplages électromagnétiques confrontés aux données expérimentales. En vue de réduire considérablement les temps de calculs, le modèle simplifié a étéappliqué à ce toron. Sa potentialité a été démontrée. Une analyse statistique de la dispersion des couplages lectromagnétiques au sein de ce toron complexe a finalement été abordée.
8

Analyse chimique par ablation laser et caractérisation du plasma induit par laser par shadowgraphy /

Gravel, Jean-François. January 2009 (has links) (PDF)
Thèse (Ph. D.)--Université Laval, 2009. / Bibliogr.: f. 127-129. Publié aussi en version électronique dans la Collection Mémoires et thèses électroniques.
9

Advanced inductively coupled plasma-mass spectrometry analysis of rare earth elements : environmental applications /

Zhu, Wangzhao, January 1999 (has links)
Diss.--Delft University of technology, 1999. / Bibliogr. à la fin des chapitres.
10

Charge par induction de véhicules électriques : analyse du potentiel, limitations, nouveaux concepts / Induction charging for electrical vehicles : Potential, limits, new concepts

Hammoud, Achraf 24 November 2017 (has links)
Les progrès concernant l’autonomie des batteries ont rendu le véhicule électrique vraiment compétitif. Cependant un problème n'est pas vraiment résolu, celui du temps de charge des batteries qui reste long même avec des bornes de forte puissance. La charge par induction peut compenser en partie ce handicap grâce à une infrastructure quasi-transparente pour l'utilisateur, basée sur l'équipement des zones de stationnement.L'objectif de cette thèse est d’étudier le potentiel et les limitations de la charge par induction, éventuellement par l'introduction de nouveaux concepts, dans la gamme des puissances de plusieurs dizaines de Kilowatts et sur des distances supérieures à 10cm entre l’inducteur et l’induit. L'obtention de bons rendements et le respect de dimensions en accord avec l'intégration dans le véhicule sont des points essentiels de la démarche.Dans un premier temps, différentes topologies de compensation de l'énergie réactive, indispensable dans cette application, sont comparées et la topologie dite Série-Série (SS) est finalement retenue. De la même façon, différentes architecture d’électronique de puissance sont évaluées. L’architecture correspondant à l'utilisation d'un onduleur primaire commandé en phase shift à fréquence variable, et d'un simple pont de diode secondaire est adoptée. Elle permet de réguler le courant injecté dans les batteries tout en simplifiant l’électronique de puissance, c.à.d. sans utiliser de convertisseurs DC-DC ni au primaire, ni au secondaire.Un outil de calcul des pertes dans le fil de Litz est ensuite mis en place. Il permet d'évaluer les pertes dans les bobinages en fonction de la section du fil et du diamètre des brins, l'objectif étant de trouver la combinaison "section de cuivre/diamètre de brins" minimisant les pertes.La troisième étape consiste à mettre en place des outils de conception analytiques complétés par des simulations "éléments finis" pour concevoir les bobinages du coupleur électromagnétique ainsi que son blindage magnétique. Des montages expérimentaux à petite échelle permettent une première validation de ces outils de conception. Enfin un algorithme d’optimisation est développé.Sur la base des solutions identifiées dans la première partie, les outils de conception ont été finalement utilisés pour concevoir un démonstrateur de 22kW, capable de transférer l’énergie sur une distance de 25cm entre l’inducteur et l’induit. Ce démonstrateur a été testé avec succès à la puissance nominale. Le rendement mesuré est de 95% lorsque les bobines primaire et secondaire sont alignées. / Scientific progress in battery field related to autonomy has made electric vehicles really competitive. However, there is a problem that hasn’t been solved yet, the duration of the charge which still high, even if high power chargers are used. Inductive charging could be a solution to that problem because the infrastructure can become almost transparent for the user if it is implemented in car park areas.The aim of this PhD work is to evaluate the potential and the limitations of inductive charging, to identify eventual new concepts, in a fast charge power range (few tens of Kilowatts) and with air gaps higher than 10cm.First, different topologies of reactive energy compensation are compared and the Series-Series (SS) topology is selected. Then, in the same way, different power electronics architecture are compared. The architecture using a phase-shifted DC-AC converter to supply the primary side and a simple power bridge to supply the secondary side is adopted. This architecture allows regulating the current in the batteries without using DC-DC converters neither on the primary side nor on the secondary side.Then, a software is implemented that is able to calculate losses in Litz wire, as a function of the wire section and the strands diameter, the aim being to choose a Litz wire that minimizes the losses in the windings.The third step is the implementation of a tool dedicated to the design of the primary and secondary coils and of the magnetic shields. The tool is based on analytic equations and finite elements simulations. The design tool is validated by means of reduced scale experiments. Finally, an optimization algorithm is implemented.Considering the solutions identified in the first part, the previous design tools are finally used to design a 22kW prototype able to transfer energy through an air gap of 25cm. This prototype has been successfully tested at nominal power. An efficiency of 95% has been measured when the two coils are aligned.

Page generated in 0.0245 seconds