• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 639
  • 7
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 656
  • 403
  • 112
  • 66
  • 62
  • 47
  • 46
  • 43
  • 39
  • 39
  • 37
  • 36
  • 33
  • 32
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Construção de um espectrofotometro multicanal e de um analisador automatico de fluxo monossegmentado

Raimundo Júnior, Ivo Milton, 1961- 20 July 2018 (has links)
Orientador: Celio Pasquini / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-20T18:19:33Z (GMT). No. of bitstreams: 1 RaimundoJunior_IvoMilton_D.pdf: 4029871 bytes, checksum: 5267beda654655ecba32df5ba2aae079 (MD5) Previous issue date: 1995 / Doutorado
112

Avaliação in vivo da precisão de localizadores foraminais preservando o coto periodontal /

Cury, Marina Tolomei Sandoval. January 2019 (has links)
Orientador: Eloi Dezan Junior / Banca: Gustavo Sivieri de Araújo / Banca: Rodrigo Ricci Vivan / Resumo: O objetivo deste trabalho foi avaliar in vivo a precisão dos localizadores foraminais Root ZXII, E-PEX e FIND ao alcançarem o limite da constrição apical, preservando o coto periodontal ou atingindo o forame apical em biopulpectomia. Para o estudo foram selecionados 90 dentes unirradiculados indicados para exodontia de pacientes que consentiram com a pesquisa. Após teste de sensibilidade pulpar positivo, foi realizado o acesso à câmara pulpar e a exploração com uma lima K#15, sob isolamento absoluto. Seguido do preparo cervical e médio com Reciproc R25, uma lima #15 foi utilizada como instrumento padrão para a odontometria, introduzida no canal, formando 2 grupos: inserção da lima até o limite da constrição apical (marca 0.5); e inserção da lima até o forame (marca 0.0) e recuar até a constrição (marca 0.5), sem remover a lima do canal. A lima foi estabilizada pelo preenchimento do canal com resina tipo flow e após fotopolimerização teve sua haste metálica cortada. Após a exodontia, os dentes foram imersos em hipoclorito de sódio 5,25% por 10 minutos para remoção de tecidos orgânicos remanescentes e então armazenados em solução fisiológica. Os dentes foram escaneados em microtomógrafo SkyScan 1272, com o auxilio do software CTAN, e realizada medida da ponta da lima ao centro da constrição e do forame apical, fornecendo dados para análise comparativa. Houve diferença estatística em detectar a constrição, após alcançar o forame, onde RootZX II mostrou maior precisão (P<0.05). C... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Abstract: This research evaluated, in vivo, the accuracy of Root ZXII, E-PEX and FIND foramen locators at the apical constriction limit, preserving the periodontal stump or until the apical foramen in biopulpectomy. For this study, 90 single-rooted teeth with extraction indication and patients' consent were selected. After positive pulpal cold sensitivity test, pulp chamber access was performed and a hand file K#15 was used to explore orifice entrance, under rubber dam. After cervical and middle instrumentation with Reciproc R25, the K#15 file was used as a standard instrument to determine working length, introduced in the root canal, forming 2 groups: insertion of the instrument until the apical constriction limit (mark 0.5); and insertion of the instrument until the foramen (mark 0.0) and repositioning at constriction (mark 0.5), without removing the file from the canal. The hand file was stabilized inside the canal with a light-cured flow resin and, after polymerization, the metal handle was cut. After extraction, teeth were immersed in 5.25% sodium hypochlorite for 10 minutes to remove remaining organic tissues and then stored in saline. The samples were analyzed through microCT SkyScan 1272, with CTAN software, which evaluated the proximity between the tip of the file to the apical constriction, providing data for comparative analysis. There was a statistical difference in detecting the constriction after reaching the foramen, where Root ZX II showed elevated accuracy (P... (Complete abstract click electronic access below) / Mestre
113

Medidor do teor de clorofila em plantas baseado em arquitetura microcontrolada / not available

Santis Junior, Jadis de 20 April 2000 (has links)
Este trabalho descreve um instrumento microprocessado para a avaliação de clorofila em plantas com a possibilidade da armazenagem de dados até 64 kbytes de 32 posições com tamanho de pixel de 1 a 16 cm2. O instrumento encontra várias aplicações na agricultura, principalmente onde o monitoramento é requerido. As principais aplicações estão em operações de fertilização e irrigação, onde o manejo de eventos são controlados pelas condições críticas como a disponibilidade de nitrogênio no solo. Resultados mostram que a operação individual ou em grupo dos sensores garantem uma adequada acurácia e resolução para aplicações agrícolas. O instrumento possibilita a fazendeiros, pesquisadores ou consultores a oportunidade do manejo localizado para sistemas de tomada de decisão. O instrumento é baseado em uma arquitetura dedicada baseada no microcontrolador 80535 e sua utilização proporciona redução de custos de processos agrícolas e redução de contaminação ambiental. / This work describes a microprocessed instrument for evaluation of chlorophyll in plants, and recording of data up to 64 kbytes at thirty-two positions with pixel size from 2 to 1.420 mm2. The instrument meets different applications in the agricultural science area, where monitoring is required. Also would apply to operations of fertilization and irrigation, where the management of events can be triggered by critical conditions such as soil nitrogen contents. Results have shown that characterization of the instrument and its individual sensors guaranteeing an adequate accuracy and resolution for agricultural application. It provides the farmer or consultant the opportunity to establish localized management rules for decision support systems. The instrument is based on complementary metal oxide semiconductor devices as well as the 80535 microcontroller. It may be operated in automatic or non-automatic mode.
114

Análise postural do endodontista na atividade clínica utilizando instrumentação rotatória e manual por meio da cinemetria, eletromiografia de superfície e checklists ergonômicos / Analysis of the endodontist posture using rotary and manual instrumentation applying kinemetry, surface electromyography and ergonomic checklists

Onety, Geraldo Celso da Silva 22 December 2011 (has links)
Atualmente a ergonomia revela-se em todas as circunstâncias na prática odontológica, desde o local de trabalho a forma como os equipamentos são utilizados, onde variáveis importantes como a postura e o movimento são determinados pela tarefa e pelo posto de trabalho. O objetivo desta pesquisa foi analisar, por meio da atividade muscular (eletromiografia), cinemetria, escalas ergonômicas (RULA e Checklist de Couto) e biofotogrametria, a postura de dezoito profissionais endodontistas, destros, com idade entre 25 e 60 anos (30 ± 3) durante o preparo químico-mecânico do sistema de canais radiculares dos molares 16 e 17, utilizando-se da técnica de instrumentação rotatória e da técnica de instrumentação manual, evidenciando os efeitos que a profissão odontológica e as posturas viciosas adotadas pelos profissionais endodontistas promovem durante as horas de trabalho nas cadeias musculares dos membros superiores e região de tronco. Baseado nos resultados obtidos nesta pesquisa pode-se concluir que as variações apresentadas nos valores eletromiográficos normalizados durante a execução das técnicas rotatória e manual sugerem que a ação dos músculos longuíssimo, deltóide anterior, deltóide médio, trapézio - fibras médias, bíceps braquial, tríceps braquial, braquiorradial e abdutor curto do polegar, propiciou adaptações musculares, com a finalidade de promover movimentos funcionais mais precisos. Na cinemetria computadorizada, observou-se que a técnica rotatória apresentou maior exigência postural do que a técnica manual, fato também evidenciado pela análise do posto de trabalho e biomecânica da atividade profissional. A análise estática da postura corporal (biofotogrametria) sugere que a atividade clínica do profissional endodontista pode contribuir para um desequilíbrio postural do quadrante superior do corpo. Concluiu-se que o profissional endodontista apresentou postura corporal comprometida, independente de trabalhar com a técnica rotatória e/ou manual. / Nowadays ergonomics has had different uses in dentistry, from the workplace to how equipments are used; where important variables, such as posture and movement, have been determined by the job and the work position. The objective of this research was to apply electromyography, kinemetry, ergonomic scales (RULA and Coutos checklist) and biophotogrammetry to analyze the posture of eighteen righthanded endodontists, aged between 25 and 60 years old (30 ± 3), during the preparation of the chemical-mechanical system of root canal of molars 16 and 17, using rotary and manual instrumentation, showing the effects of endodontists profession and vicious postures during hours of work on muscle chains of upper limbs and trunk. Based on the results it is possible to conclude that the variations showed in the electromyographic values normalized during the use of rotary and manual techniques, suggest that longissimus, anterior and middle deltoid, trapezium medium fibers, brachial biceps and triceps, brachioradialis and short abducent of the thumb, provided muscle adaptations in order to cause functional more accurate movements. In computer kinemetry the rotary technique was more postural demanding than the manual technique, that was also showed by the analysis of the work position and biomechanics of the profession. The static analysis of the body posture (biophotogrammetry) suggests that the professional activity of the endodontist can contribute for a postural imbalance of upper body. In conclusion, the endodontist presented compromised posture regardless the kind of technique he/she uses: rotary and/or manual.
115

Análise postural do endodontista na atividade clínica utilizando instrumentação rotatória e manual por meio da cinemetria, eletromiografia de superfície e checklists ergonômicos / Analysis of the endodontist posture using rotary and manual instrumentation applying kinemetry, surface electromyography and ergonomic checklists

Geraldo Celso da Silva Onety 22 December 2011 (has links)
Atualmente a ergonomia revela-se em todas as circunstâncias na prática odontológica, desde o local de trabalho a forma como os equipamentos são utilizados, onde variáveis importantes como a postura e o movimento são determinados pela tarefa e pelo posto de trabalho. O objetivo desta pesquisa foi analisar, por meio da atividade muscular (eletromiografia), cinemetria, escalas ergonômicas (RULA e Checklist de Couto) e biofotogrametria, a postura de dezoito profissionais endodontistas, destros, com idade entre 25 e 60 anos (30 ± 3) durante o preparo químico-mecânico do sistema de canais radiculares dos molares 16 e 17, utilizando-se da técnica de instrumentação rotatória e da técnica de instrumentação manual, evidenciando os efeitos que a profissão odontológica e as posturas viciosas adotadas pelos profissionais endodontistas promovem durante as horas de trabalho nas cadeias musculares dos membros superiores e região de tronco. Baseado nos resultados obtidos nesta pesquisa pode-se concluir que as variações apresentadas nos valores eletromiográficos normalizados durante a execução das técnicas rotatória e manual sugerem que a ação dos músculos longuíssimo, deltóide anterior, deltóide médio, trapézio - fibras médias, bíceps braquial, tríceps braquial, braquiorradial e abdutor curto do polegar, propiciou adaptações musculares, com a finalidade de promover movimentos funcionais mais precisos. Na cinemetria computadorizada, observou-se que a técnica rotatória apresentou maior exigência postural do que a técnica manual, fato também evidenciado pela análise do posto de trabalho e biomecânica da atividade profissional. A análise estática da postura corporal (biofotogrametria) sugere que a atividade clínica do profissional endodontista pode contribuir para um desequilíbrio postural do quadrante superior do corpo. Concluiu-se que o profissional endodontista apresentou postura corporal comprometida, independente de trabalhar com a técnica rotatória e/ou manual. / Nowadays ergonomics has had different uses in dentistry, from the workplace to how equipments are used; where important variables, such as posture and movement, have been determined by the job and the work position. The objective of this research was to apply electromyography, kinemetry, ergonomic scales (RULA and Coutos checklist) and biophotogrammetry to analyze the posture of eighteen righthanded endodontists, aged between 25 and 60 years old (30 ± 3), during the preparation of the chemical-mechanical system of root canal of molars 16 and 17, using rotary and manual instrumentation, showing the effects of endodontists profession and vicious postures during hours of work on muscle chains of upper limbs and trunk. Based on the results it is possible to conclude that the variations showed in the electromyographic values normalized during the use of rotary and manual techniques, suggest that longissimus, anterior and middle deltoid, trapezium medium fibers, brachial biceps and triceps, brachioradialis and short abducent of the thumb, provided muscle adaptations in order to cause functional more accurate movements. In computer kinemetry the rotary technique was more postural demanding than the manual technique, that was also showed by the analysis of the work position and biomechanics of the profession. The static analysis of the body posture (biophotogrammetry) suggests that the professional activity of the endodontist can contribute for a postural imbalance of upper body. In conclusion, the endodontist presented compromised posture regardless the kind of technique he/she uses: rotary and/or manual.
116

Medidor do teor de clorofila em plantas baseado em arquitetura microcontrolada / not available

Jadis de Santis Junior 20 April 2000 (has links)
Este trabalho descreve um instrumento microprocessado para a avaliação de clorofila em plantas com a possibilidade da armazenagem de dados até 64 kbytes de 32 posições com tamanho de pixel de 1 a 16 cm2. O instrumento encontra várias aplicações na agricultura, principalmente onde o monitoramento é requerido. As principais aplicações estão em operações de fertilização e irrigação, onde o manejo de eventos são controlados pelas condições críticas como a disponibilidade de nitrogênio no solo. Resultados mostram que a operação individual ou em grupo dos sensores garantem uma adequada acurácia e resolução para aplicações agrícolas. O instrumento possibilita a fazendeiros, pesquisadores ou consultores a oportunidade do manejo localizado para sistemas de tomada de decisão. O instrumento é baseado em uma arquitetura dedicada baseada no microcontrolador 80535 e sua utilização proporciona redução de custos de processos agrícolas e redução de contaminação ambiental. / This work describes a microprocessed instrument for evaluation of chlorophyll in plants, and recording of data up to 64 kbytes at thirty-two positions with pixel size from 2 to 1.420 mm2. The instrument meets different applications in the agricultural science area, where monitoring is required. Also would apply to operations of fertilization and irrigation, where the management of events can be triggered by critical conditions such as soil nitrogen contents. Results have shown that characterization of the instrument and its individual sensors guaranteeing an adequate accuracy and resolution for agricultural application. It provides the farmer or consultant the opportunity to establish localized management rules for decision support systems. The instrument is based on complementary metal oxide semiconductor devices as well as the 80535 microcontroller. It may be operated in automatic or non-automatic mode.
117

Detecção condutométrica sem contato (oscilométrica) para eletroforese capilar de zona e cromatografia micelar eletrocinética / Contactless conductivity detection for capillary zone electrophoresis and micellar electrokinetic chromatography

Silva, José Alberto Fracassi da 19 March 2001 (has links)
Este trabalho descreve a construção e avaliação de um detector condutométrico sem contato (oscilométrico) para sua aplicação em eletroforese capilar de zona e cromatografia micelar eletrocinética (MEKC). A construção do detector contou com a avaliação de diversos materiais e métodos para a confecção dos eletrodos, tão bem como o aperfeiçoamento do seu circuito eletrônico. O seu comportamento e desempenho foram verificados através do estudo dos diversos parâmetros que influenciam sua resposta, como freqüência e amplitude do sinal aplicado, temperatura e condutividade do meio. Além disso, a simulação do circuito equivalente da cela de detecção auxiliou no entendimento das propriedades do detector frente a alterações na condutividade do meio, na freqüência de operação e nas dimensões da cela. A otimização dos parâmetros operacionais foi racionalizada pela formulação de equações analíticas que descrevem o fator de resposta do detector a partir de parâmetros obtidos experimentalmente. Para o desenvolvimento do sistema de detecção, dois equipamentos completos de eletroforese capilar foram construídos. Sistemas de injeção de amostra por pressão, por gravidade, e eletrocinética foram desenvolvidos. Um dos equipamentos permite que a injeção da amostra seja feita do lado aterrado da fonte de alta tensão. Conseqüentemente, o detector é posicionado próximo do ponto de aplicação da alta tensão. Este é, de que se tem notícia, o primeiro sistema de detecção eletroquímico para eletroforese capilar com essa característica. A termostatização dos capilares foi efetuada por convecção forçada de ar. De maneira a aumentar o grau de automação e facilitar o seu manuseio, os dois equipamentos foram interfaceados a microcomputador. Os equipamentos de eletroforese com detecção oscilométrica construídos permitiram a análise de diversas substâncias em matrizes variadas, como por exemplo íons orgânicos e inorgânicos em água de chuva e material particulado, ácidos graxos de cadeia linear em gordura de coco, formaldeído na fase gasosa da atmosfera, e, pela primeira vez, espécies neutras, como álcoois alifáticos, separadas por MEKC. / This work describes the construction and evaluation of a contactless conductometric (or oscillometric) detector, for its application in capillary zone electrophoresis and micellar electrokinetic chromatography (MEKC). The materials and methods used for the construction of the electrodes, as well as the improvements on the electronic circuit, were evaluated. The behavior and performance of the detector were studied by changing the parameters that affect its response, e. g., the frequency and amplitude of the input signal, temperature and solution conductivity. The simulation of the cell equivalent electric circuit helped to understand the detector properties related to the variations in the solution conductivity, frequency, and cell dimensions. The optimization of the parameters was conducted by the formulation of analytical equations that describe the response factor using experimental data. For the detection development, two complete capillary electrophoresis equipments were constructed. Pressure, gravity, and electrokinetic sample injection systems were developed. One of the equipments allows the sample injection on the grounded side of the capillary. Consequently, the detector is placed near the high voltage application point. This is the first electrochemical detector described for capillary electrophoresis with this characteristic. The capillary thermostating was made by passing a forced air stream. Both equipments were interfaced to microcomputers. The capillary electrophoresis equipments with oscillometric detection were applied to the analysis of many types of compounds in different matrices, such as organic and inorganic ions in rainwater and particulate material, fatty acids in cocoa oil, formaldehyde in the atmosphere and, for the first time, neutral species, like aliphatic alcohols, separated by MEKC.
118

Transformando o 152Eu em um Padrão de Calibração de Eficiência para Deteção de Gamas

Castro, Ruy Morgado de 16 December 2003 (has links)
Neste trabalho foram desenvolvidas as etapas necessárias para transformar a fonte policromática de 152Eu, t1/2 = 13,525(14) anos, em um padrão de calibração de intensidade gama para detetores de HPGe. Foram colocados, por meio de medições de espectroscopia <span style='font-family: Symbol'>g-g do decaimento do 152Eu, 4 níveis no esquema do 152Sm, dos quais 1 novo, e 36 transições, sendo 25 no 152Sm e 11 no 152Gd, das quais 23 foram observadas pela primeira vez. O conjunto dos efeitos secundários de deteção e sua influência sobre as áreas dos picos foram modelados e validados experimentalmente. As áreas dos picos foram descritas a partir das eficiências de deteção e dos parâmetros de decaimento: razões de ramificação, frações de alimentação beta, multipolaridades das transições e coeficientes de conversão interna. As áreas foram ajustadas aos valores experimentais, obtidos em medições de espectroscopia gama simples, fornecendo estimativas para razões de ramificação e frações de alimentação beta dos esquemas de níveis do 152Sm e do 152Gd, de onde foram obtidas as intensidades e correlações estatísticas das transições gama mais intensas que seguem o decaimento do 152Eu. / The steps needed to transform the polychromatic 152Eu, t1/2 = 13,525(14) y, <span style='font-family: Symbol'>g-ray source into a standard for efficiency calibration of HPGe detectors have been developed. Through <span style='font-family: Symbol'>g-g coincidence measurements of the 152Eu decay, 4 levels were placed in the 152Sm scheme, one new, and 36 transitions, 25 in the 152Sm and 11 in 152Gd, where 23 were observed for the first time. The influence of secondary detection effects in the peak areas were evaluated and the corresponding models have been experimentaly checked. Peak-area formulas have been derived from the efficiencies and decay parameters: branching ratios, beta feeding fractions, transition multipolarities and internal conversion coefficients. The experimental data from the $gamma$-ray singles spectrum were fitted by the Least-Squares Method, providing estimates for the branching ratios and beta feeding fractions for the level schemes of 152Sm and 152Gd, allowing the calculation of the intensities and statistical correlations of the most intense gamma transitions following the 152Eu decay.
119

Monitoramento de barragens de contenção de rejeitos da mineração. / Monitoring tailings dams of the mining.

Machado, William Gladstone de Freitas 03 December 2007 (has links)
Esta dissertação é uma contribuição, através de uma pesquisa bibliográfica, sobre o tema instrumentação e monitoramento em empreendimentos de barragens de rejeitos da mineração. Nesta pesquisa apresentam-se os objetivos básicos da instrumentação de barragens e suas características técnicas, metodologia construtiva das barragens de rejeitos e seu monitoramento através de auscultação da instrumentação. Como limitação do trabalho, devido à variedade de instrumentos que podem ser instalados em uma barragem, buscou-se pesquisar os instrumentos de medição de deslocamentos e controle de fluxo percolante, sendo os mais utilizados em barragens de terra e rejeitos. Justifica-se este tema motivado pelos últimos acidentes ocorridos em barragens de contenção de rejeitos, enfatizando a importância e a necessidade permanente da melhoria das condições de segurança e monitoramento das barragens brasileiras. Estes acidentes causam danos à população do entorno da barragem, econômicos ao empreendedor e ambientais. Como resultado obtido nesta pesquisa pode-se concluir que propiciou conhecimento atualizado ao meio técnico nacional de barragens. / This dissertation is a contribution, through a bibliographical research, on the subject of instrumentation and monitoring in enterprises of tailings dams. This research presents the basic objectives of the instrumentation of dams, their technical characteristics, the construction methodology of tailings dams and their monitoring through auscultation of the instrumentation. Due to the variety of instruments that can be installed in a dam, this work was limited to the analysis of two segments, instruments of measurement displacements and those for controlling percolation flow, which are the most commonly used in earth and tailings dams. This study is justified due to recent accidents occurring in tailings dams, which stress the importance and the permanent necessity of the improvement in security and monitoring conditions of Brazilian dams. These accidents cause social, economic and environmental damages to the enterprise. As a result of this research it can be concluded that it contributed with up-to-date knowledge to the national technical dam sector.
120

Desenvolvimento de equipamento de testes eletrônicos para câmera multiespectral do satélite CBERS / Development of a ground support equipment for electronic tests of the multispectral imager from CBERS satellite

Pazelli, Henrique Cunha 31 May 2007 (has links)
Este trabalho apresenta o desenvolvimento de um equipamento para testes eletrônicos, GSE (Ground Support Equipment), em nível de sistema e subsistema do imageador multiespectral (MUX) do satélite CBERS3&4, a primeira câmera espacial desenvolvida no país. O projeto foi realizado com base em um modelo de referência para o desenvolvimento de produtos mecatrônicos. O GSE utiliza instrumentação virtual, um banco óptico e outros equipamentos controlados por computador e integrados por uma eletrônica própria para testar todos os requisitos funcionais do subsistema. Além disso, é capaz de simular outros subsistemas do satélite que possuam interface com a câmera MUX, tais como o DDR (Digital Data Recorder), OBDH (On-Board Data Handler) e o EPSS (Eletrical Power Supply Subsystem). Como resultado, este trabalho apresenta os testes realizados pelo equipamento desenvolvido, ressaltando sua funcionalidade. / This work presents the development of an equipment for electronic tests, GSE (Ground Support Equipment), in system and subsytem levels of the multispectral imager from CBERS3&4 satellite, the first camera for space applications developed in the country. This project was developed using a reference model for mechatronic products development. GSE utilizes virtual instrumentation, an optical bench and other equipments controled by computer and integrated by its own electronics to test all subsystem functional requirements. Besides, GSE is capable to simulate all others satellite subsystems which share interfaces with MUX, such as DDR (Digital Data Recorder), OBDH (On-Board Data Handler) and EPSS (Eletrical Power Supply Subsystem). As a result, this work presents the tests accomplished by the developed equipment, emphasizing its functionality.

Page generated in 0.0919 seconds