• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 108
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 111
  • 111
  • 38
  • 21
  • 20
  • 15
  • 14
  • 13
  • 12
  • 12
  • 11
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Instrumentação sem fio para avaliação em tempo real de parâmetros objetivos de fadiga muscular / Wireless instrumentation for real time assessment of objectives parameters of muscle fatigue

Abrantes, Luiz Paulo Rosa 22 November 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2016. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-05-16T21:21:45Z No. of bitstreams: 1 2017_LuizPauloRosaAbrantes.pdf: 7246613 bytes, checksum: 116baef06e861bf64bf5954d718decab (MD5) / Rejected by Raquel Viana (raquelviana@bce.unb.br), reason: Boa noite, Por favor, adicione o campo orientador, o campo de título alternativo, e arrume as datas no campo de referência. Atenciosamente on 2017-05-17T22:30:19Z (GMT) / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-05-18T16:20:50Z No. of bitstreams: 1 2017_LuizPauloRosaAbrantes.pdf: 7246613 bytes, checksum: 116baef06e861bf64bf5954d718decab (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-05-26T18:48:13Z (GMT) No. of bitstreams: 1 2017_LuizPauloRosaAbrantes.pdf: 7246613 bytes, checksum: 116baef06e861bf64bf5954d718decab (MD5) / Made available in DSpace on 2017-05-26T18:48:13Z (GMT). No. of bitstreams: 1 2017_LuizPauloRosaAbrantes.pdf: 7246613 bytes, checksum: 116baef06e861bf64bf5954d718decab (MD5) Previous issue date: 2017-05-26 / Esta dissertação apresenta a concepção de uma instrumentação sem fio para aquisição e apresentação de sinais em tempo real, com ênfase no sinal de eletromiografia. A ferramenta computacional é capaz de apresentar os diversos indicadores objetivos de fadiga também em tempo real, sendo este o diferencial deste trabalho. Dois dos indicadores de fadiga utilizados, RMS e MDF, são bem conhecidos da literatura, o primeiro é de origem temporal, e o segundo de origem frequencial. O terceiro indicador apresentado é proveniente da transformada Wavelet, e é denominado SWW. A ferramenta apresenta também indicadores acumulativos derivados destes três indicadores. Essas versões acumulativas apresentaram bons resultados quanto à minimização das perturbações inerentes à aquisição do sinal de eletromiografia. Foram desenvolvidos: uma estação remota, que utiliza a tecnologia bluetooth para a transmissão sem fio dos sinais, e um programa computacional (plataforma LabVIEW) responsável pela reconstrução dos sinais e apresentação dos indicadores de fadiga. Foi utilizado um protocolo de contração isométrica para a avaliação dos resultados da ferramenta quanto a indicação da fadiga. Houve similaridade na indicação da fadiga através dos indicadores MDF e RMS, com outros resultados obtidos em trabalhos acerca do assunto. Os resultados preliminares, quanto a aquisição e apresentação em tempo real dos sinais eletromiografia, são satisfatórios mediante aos objetivos inicias propostos. A ferramenta vem sendo apresentada à profissionais e pesquisadores no assunto e nota-se, boas avaliações da instrumentação. / This dissertation presents the conception of a wireless instrumentation for acquisition and presentation of signal in real time, with emphasis in electromyography signal. The computational tool is able to present several fatigue indexes at real time, being the differetial of this work. Two fatigue index presented in this work, RMS and MDF, are wellknown indexes, the first is derived from time domain and the former is derived from frequency domain. The third presented index is from Wavelet transform, this is called SWW. The software also presents accumulated version derived from these three fatigue indexes. These accumulated version presented good results in minimizing the inherent disturbances in the acquisition of the electromyography signal. Were developed: a remote station, that uses bluetooth technology for the wireless transmission of signals, and a software (developed in LabVIEW) responsible for signals reconstruction and presentation of fatigue indexes. An isometric contraction protocol was used to evaluate the tool results regarding the fatigue indication. There was similarity in fatigue indication through MDF and RMS indexes, with results obtained in other studies of the area. Preliminary results, as the acquisition and presentation in real time of electromyography signals, are satisfatory against the proposed initial objectives. The tool has been presented to professional and researchers it the subject and it is noted a good evaluations of the instrumentation.
22

Análise de três métodos de estimativa da evapotranspiração de referência para a região de Pradópolis - SP

Balotta, Graciano Augusto Peviani [UNESP] 10 November 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-11-10Bitstream added on 2014-06-13T19:28:59Z : No. of bitstreams: 1 balotta_gap_me_jabo.pdf: 233319 bytes, checksum: 23b0129b8a38f43d1dd6a512cb94ef29 (MD5) / O objetivo desse trabalho foi avaliar três métodos de estimativa da evapotranspiração de referência (Hargreaves, Radiação Solar e Makkink), comparando-os com o método de Penman-Monteith, recomendado pela Organização das Nações Unidas para a Alimentação e Agricultura (FAO) como método padrão para estimativa da ETo, para o município de Pradópolis - SP. Para esse fim foi instalada no posto agrometeorológico da cidade de Pradópolis - SP uma estação meteorológica automatizada. Por intermédio desta estação foram obtidas medidas da radiação solar global, temperatura do ar, umidade relativa do ar e velocidade do vento. A análise dos resultados foi feita por uma técnica que considera os erros da ET0. O resultado da avaliação dos métodos indica um melhor ajuste para estimativa da ETo para o método de Hargreaves. Os métodos de Makkink e Radiação Solar não obtiveram um ajuste satisfatório com o do Penman-Monteith. Para avaliar métodos de estimativa da evapotranspiração deve-se considerar os erros da estimativa da ETo, evitando possíveis erros de avaliação / The aim of this investigation was to evaluate two reference methods to Monteith method, recommended by the Food and Agricultural Organization of the United Nations (FAO) as the standard method for estimating ETo in Pradópolis - SP. To this data collection, an automated weather station was installed in the meteorological station at Pradópolis - SP. Through estimate evapotranspiration (Hargreaves, Radiation and Makkink), compared to Penman-this station, we obtained measures of global solar radiation, air temperature, relative humidity and wind speed. The analysis was done by a technique that considers the mistakes of ETo, which depends on the combination of the errors of the variables that make up the estimating equations, derived from the measurement instruments used to obtain these variables. The aftermath showed a better adjustment to Hargreaves. Makkink, and Radiation methods are different from Penman-Monteith, therefore, they cannot be compared. To evaluate methods to estimate evapotranspiration and avoid possible evaluation errors, ETo estimate errors must be considered
23

Métodos de estimativa da evapotranspiração de referência para a mesoregião do Triângulo Mineiro e Alto Paranaíba-MG /

Lacerda, Zilda Corrêa de. January 2012 (has links)
Orientador: José Eduardo Pitelli Turco / Banca: Renato Farias do Valle Junior / Banca: Pedro Henrique Ferreira Tomé / Banca: João Antonio Galbiatti / Banca: Teresa Cristina Tarle Pissarra / Resumo: Uma forma de verificar a eficiência de métodos de estimativa da evapotranspiração de referência é a comparação com o método de Penman- Monteith, recomendado pela Organização das Nações Unidas para Alimentação e Agricultura - FAO, como método padrão para estimativa da ET0. Com este estudo o objetivo foi avaliar três métodos de estimativa da ET0 e a influência dos erros diários na comparação dos métodos Makkink, Hargreaves e Radiação Solar, com o método de Penman-Monteith em quatro municípios da mesoregião do Triângulo Mineiro e Alto Paranaíba - MG. Para tanto, utilizou-se dados diários do ano de 2010 de radiação solar global, velocidade do vento, temperatura do ar e umidade relativa do ar obtidos nas estações meteorológicas automáticas do 5º Distrito de Meteorologia do Instituto Nacional de Meteorologia situadas nos municípios de Uberlândia, Araxá, Patrocínio e Ituiutaba. As análises dos resultados foram feitas para o período diário, utilizandose análise de regressão modelo linear y = ax, no qual a variável dependente foi o método de Penman-Monteith e a variável independente as estimativas da ET0 pelos métodos estudados. Foi utilizada metodologia que verifica a influência do desvio padrão diário da ET0 na comparação dos métodos estudados, indicando que entre os métodos de Radiação Solar e Penman-Monteith não se estabeleceu uma relação linear. Portanto, não podem ser comparados para as localidades estudadas. O resultado da análise de regressão indicou melhor ajuste para estimativa da ET0 para o método de Hargreaves para os quatro municípios estudados / Abstract: A way to check the efficiency of estimating methods for reference of evapotranspiration is compared with the Penman-Monteith, recommended by the United Nations Food and Agriculture Organization - FAO, as the standard method for estimating ET0. With this study the objective is to evaluate three methods for estimating ET0 and the influence of errors daily in the comparison of methods Makkink, Hargreaves and Solar Radiation, with the Penman-Monteith in four counties from the middle of Triângulo Mineiro and Alto Paranaíba - MG. To this end, we used daily data of the year 2010 of the global solar radiation, wind speed, air temperature and relative humidity obtained from automatic weather stations of the 5th District of Meteorology's National Meteorological Institute located in the cities of Uberlândia, Araxá, Patrocínio and Ituiutaba. Analyzes of the results were made for the daily period, using linear regression model y = ax, where the dependent variable was the Penman-Monteith and the independent variable estimates of ET0 by the methods studied. Methodology was used to verify the influence of the standard deviation of daily ET0 in the comparison of the methods studied, indicating that among the methods of Solar Radiation and Penman-Monteith it was not established a linear relationship. Therefore, it cannot be compared to the studied cities. The result of the regression analysis indicated a better fit for the estimation of ET0 to the method of Hargreaves for the four studied cities / Doutor
24

Utilização de sensores magnéticos para medição de deslocamento sem contato

Brusamarello, Valner Joao January 1996 (has links)
O objetivo deste trabalho é desenvolver e avaliar um sistema capaz de reproduzir na tela de um microcomputador o movimento de um ponto, sem qualquer contato no mesmo. Para construir o protótipo foram utilizados sensores magnetoresistivos, um superímã, e para calibração, uma mesa adaptada com três parafusos micrométricos, capaz de realizar um deslocamento nas coordenadas x, y e z de um sistema tridimensional. Este estudo foi dividido em duas partes, na primeira avaliou-se o comportamento do sistema para a variação de deslocamento em um plano, caracterizando um movimento em duas dimensões (20). Na segunda parte, foi inserido um terceiro eixo, reproduzindo assim deslocamentos em 3 dimensões (30). O sistema apresentou resultados coerentes e comprovou ser uma opção para medidas desta natureza. Considerando-se os limites de precisão e tolerância necessárias, aplicações nas áreas de controle e Engenharia Biomédica podem ser implementadas baseadas no estudo de medidas sem contato. / The aim of this work is to develop and evaluate a system to reproduce the movement of a point on a microcomputer screen in real time and contactless between the point and the sensor. To build the prototype, were used magnetoresistives sensors, a magnet and a calibration table adapted with three micrometric screws to accomplish the displacement on x, y and z coordenates of a 30 system. This study has been divided into two parts. In the first, the bahaviour of the system was asseded for the displacement variation of a point on a plane (20). In the second part, a third axis was inserted, thus reproducing 30 displacements. The system has present consistent resuslts and prove to be an alternative for mesurements of this nature. Considering necessary accuracy and tolerance limits, aplications in Control and Biomedical Engeneering can be implemented, based on the study of contactless mesurement.
25

Proposta de metodologia para a avaliação do desempenho de instrumentos de medição da qualidade da energia elétrica / Proposal methodology to evaluate the operating performance of power quality measurement instruments

Rodriguez Sañudo, Carlos Anibal 21 September 2012 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Deparamento de Engenharia Elétrica, 2012. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-02-04T13:07:08Z No. of bitstreams: 1 2012_CarlosAnibalRodriguezSanudo.pdf: 7986861 bytes, checksum: ef729876c21927bbebee4642db4fd1da (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-02-04T14:56:19Z (GMT) No. of bitstreams: 1 2012_CarlosAnibalRodriguezSanudo.pdf: 7986861 bytes, checksum: ef729876c21927bbebee4642db4fd1da (MD5) / Made available in DSpace on 2013-02-04T14:56:19Z (GMT). No. of bitstreams: 1 2012_CarlosAnibalRodriguezSanudo.pdf: 7986861 bytes, checksum: ef729876c21927bbebee4642db4fd1da (MD5) / Este trabalho apresenta uma nova metodologia para a avaliação do desempenho funcional de instrumentos de medição de qualidade da energia elétrica. Trata-se de um procedimento que contempla os aspectos técnicos e metrológicos demandados pela IEC 61000-4-30 (2008), para cada um dos parâmetros de qualidade da energia, por meio do uso do ISO-GUM (2008). A IEC 61000-4-30 é uma diretriz que visa à padronização das medições dos parâmetros da qualidade da energia elétrica, indi- cando os métodos e as técnicas para a quanti cação dos mesmos. Já o ISO-GUM é um guia elaborado para a ciência da metrologia com a nalidade de estabelecer regras referentes à expressão da incerteza de medições para uso em padronização, calibração, acreditação de laboratórios e serviços metrológicos. Da junção destes conhecimentos, são propostos três tipos de testes que permitem a identi cação dos aspectos irregulares dos medidores considerando-se as exigências da IEC 61000-4- 30. Para garantir repetitividade nos resultados, a metodologia estruturou-se em três cadernos elaborados com os procedimentos para a execução dos mencionados testes. O produto é um relatório que expressa o desempenho do instrumento sob avalia- ção e torna possível a identi cação das aptidões e das de ciências dos instrumentos voltados à medição da qualidade da energia elétrica. São ainda expostos procedi- mentos laboratoriais, e um exemplo de aplicação da metodologia proposta sobre um medidor. ______________________________________________________________________________ ABSTRACT / This dissertation proposes a methodology to evaluate the operating performance of power quality measurement instruments. It entails a procedure which includes, for each power quality parameter, technical and metrological characteristics deman- ded by the IEC 61000-4-30 (2008), through use of the ISO-GUM (2008). The IEC 61000-4-30 provides measurement methods and sets accuracy levels for the power quality parameters. The main motivation for this standard is to provide common requirements for measurement devices to ensure that power quality meters from di erent manufacturers give the same results. The ISO-GUM is a guide that esta- blishes general rules for evaluating and expressing uncertainty in measurements that are intended to be applicable for standardization, calibration, laboratory accreditation and metrology services. Three types of tests to identify the irregular aspects of meters considering the requirements of the IEC 61000-4-30 are proposed from the joining of this standard and this guide. The methodology is structured into three notebooks with the procedures established for the implementation of the above tests to ensure repeatability of the results. The product is a report that expresses the performance of the instrument under evaluation and makes it possible to identify the qualities and shortcomings of instruments designed to measure power quality. Moreover, the laboratory results of employing the aforementioned methodology with the measuring equipment are put forth.
26

Pressão lateral em formas para concreto

Cruz, Rosana Maximo da 24 June 1998 (has links)
Orientador: Mauro Augusto Demarzo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-23T18:42:57Z (GMT). No. of bitstreams: 1 Cruz_RosanaMaximoda_M.pdf: 3857368 bytes, checksum: 4b501cefb73b6e9e5ba8f89456652ebe (MD5) Previous issue date: 1997 / Resumo: Neste trabalho, estudou-se as pressões laterais causadas pelo lançamento do concreto fresco nas fôrmas. Analisou-se alguns fatores os quais influenciam no comportamento dessas pressões. Foram estudados vários trabalhos de pesquisadores que desenvolveram expressões para o cálculo de pressões laterais, onde o produto da densidade do concreto pela altura é considerada, em algumas expressões, como limite máximo dessa pressão. Com os resultados dos ensaios, foi feita a análise estatística da influência das variáveis abatimento do concreto e velocidade de lançamento do concreto, no comportamento das pressões laterais, em várias alturas. Encontrou-se, então, uma expressão geral, em função dessas variáveis e da altura de concreto lançado. Avaliou-se a confiabilidade do ensaio proposto para determinação das pressões ao longo da altura da fôrma / Abstract: In this work the lateral pressures caused by placement of the fresh concrete in the formwork has been investigated. Some factors that have influenced the behaviour of these pressure were analysed. Several research works conceming equations for the lateral pressure calculation, which consider the density product of the concrete by the height as maximum limit of this pressure, were studied. With the test results, it was statistically analyzed the influence of the variables slump and concrete pour rate, on the lateral pressure behaviour, in several heights. With these variables and the height of placed concrete, a general equation was found. The reliability of the proposed test to determine the pressures along the formwork height was analyzed. / Mestrado / Estruturas / Mestre em Engenharia Civil
27

Implementação da técnica de medição por intensimetria para a determinação da potência sonora de fontes acústicas.

Cândido Magno de Souza 01 March 2006 (has links)
Este trabalho tem como principal objetivo a análise e implementação da técnica de intensimetria no Instituto de Aeronáutica e Espaço (IAE). Nesta análise, são feitas comparações de resultados de potência sonora entre o método da pressão sonora com a técnica de intensimetria, utilizando os métodos de pontos discretos e de varredura com bons resultados. Também é apresentado o procedimento adotado como solução para atingir os padrões requeridos pela norma ISO 9614, utilizando a instrumentação disponível no laboratório de medições acústica (AIE-EDI), com excelentes resultados em bandas de freqüência de 1/1 e 1/3 oitava.
28

Modelagem numérica e análise do acoplamento dinâmico estrutural por isoladores de vibração em aeronaves

Isabel Lima Hidalgo 06 December 2012 (has links)
Com o intuito de reduzir o ruído interno na cabine de aeronaves, isoladores de vibração fabricados com elastômero são montados entre a fuselagem e os painéis do interior da aeronave. Uma avaliação precisa dos caminhos de transmissão das vibrações e a correta predição dos níveis de ruído interno pode ser obtida através de modelos numéricos adequados dos isoladores e da forma com que estes acoplam a fuselagem aos painéis internos da cabine. Em geral, modelos simplificados não são capazes de prever o desempenho do isolador em frequências médias e altas, uma vez que não consideram modos naturais de vibração do próprio material do isolador. Além disto, as propriedades dinâmicas do material visco-elástico utilizado nestes isoladores não são adequadamente identificadas pelos fabricantes. Neste trabalho, testes experimentais foram realizados para se caracterizar a rigidez dinâmica do isolador. As propriedades mecânicas do elastômero foram obtidas para uma correta análise do modelo de elementos finitos, e a partir do modelo numérico atualizado, foi possível obter frequências naturais e modos de vibração e, conhecer parâmetros do real comportamento do isolador. Diferentes abordagens e complexidades para os modelos clássico de massa-mola-amortecedor e de matriz de transferência foram utilizadas para obter o comportamento dinâmico dos isoladores de vibração. Para a avaliação das diferentes formas de modelagem do isolador, considerou-se um modelo contendo um painel reforçado e um painel simples conectados por isoladores, os quais remetem a uma estrutura fuselagem-isolador-painel interior. Com este modelo foi possível comparar a resposta dinâmica e valores do fator de perda por acoplamento obtidos a partir de modelos numéricos, baseados em FEM, SEA, e híbrido SEA-FEM. Neste último, o modelo dos painéis em SEA foi combinado com o modelo em FEM do isolador. Esta combinação em modelo híbrido proporcionou obter maior fidelidade no acoplamento fuselagem-isolador-painel interno, e consequentemente levaria a predição mais acurada dos níveis de ruído dentro da cabine da aeronave.
29

Abordagem sistêmica de análise metrológica aplicada na calibração de baixa umidade

Alberto de Paula Silva 07 August 2014 (has links)
Este trabalho tem como objetivo apresentar uma abordagem sistêmica para realização de análise metrológica de sistemas de calibração. As atividades de análise metrológica realizadas por diversos autores e os conceitos da engenharia de sistemas servem como base para o desenvolvimento do trabalho. A partir dessa abordagem sistêmica, são propostos estrutura, escopo e ciclo de análise metrológica, a fim de estabelecer um processo que possa ser replicado e que possa auxiliar o desenvolvimento e atualização de um sistema de calibração. O processo inclui identificação de requisitos, acompanhamento de soluções e iteratividade. A abordagem sistêmica de análise metrológica foi aplicada a um sistema de calibração de baixa umidade. O resultado mostra que quanto mais abrangente e estruturada for a análise, maior é a possibilidade de o sistema atender os requisitos necessários.
30

Desenvolvimento e qualificação metrológica de um fluxímetro tipo turbina aplicado aos processos de soldagem

Maurici, Adriano Virgilio January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-17T23:26:51Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T16:31:18Z : No. of bitstreams: 1 175561.pdf: 17377319 bytes, checksum: d1a8ca50bd136095ebae2fb3d8b9f6df (MD5) / Este trabalho apresenta o desenvolvimento de um fluxímetro tipo turbina aplicado aos processos de soldagem, incluindo também a proposta de um procedimento para a calibração deste tipo de instrumento. O interesse para tal pesquisa surgiu a partir de um estudo conduzido para identificar a influência do fluxo de gás na qualidade e no custo de processos de soldagem que utilizam proteção gasosa de fonte externa, como o MIG/MAG, TIP e PLASMA. As diretrizes para projeto do sistema de medição tipo turbina, assim como os procedimentos propostos para a calibração, seguem a norma ABNT/ISO 9951 (Medidores de Vazão de Gás em Condutos Fechados - Medidores tipo Turbina). Para fornecer informações necessárias ao projeto foram conduzidos estudos para definir uma tecnologia para a identificação e medição da velocidade de rotação do rotor da turbina, os mancais à serem utilizados e disposição do eixo do rotor em relação ao fluxo de gás. Alguns destes parâmetros foram selecionados a partir de testes experimentais, conduzidos em uma bancada de ensaios montada com instrumentos rastreados. Esta bancada permitiu otimizar o desempenho do medidor e verificar a eficácia do método de calibração.

Page generated in 0.1413 seconds