• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 5
  • 4
  • Tagged with
  • 19
  • 19
  • 14
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Propuesta de mejora en el servicio posventa en una empresa distribuidora de equipos médicos a nivel nacional

Herrera Benítez, Mónica del Rosario 10 August 2015 (has links)
El presente trabajo plantea una propuesta de mejora precisa, indispensable, a partir de la identificación y el análisis de las causas que generan el mal desempeño del servicio posventa en una empresa distribuidora de equipos médicos a nivel nacional. La importancia de esta propuesta radica en que, si bien el incremento de ventas de equipos médicos genera una aparente solidez de la empresa, probablemente esta no sobreviva en un tiempo no muy lejano por la falta de actualización de sus procesos y la debida aplicación de métodos de trabajo que contribuyan a la eficacia del servicio posventa que, adicionalmente, brinda la empresa. El marco teórico propone enfocar toda la actividad de la organización como un proceso con la finalidad de definir de manera sistemática las actividades que componen el proceso, identificar la interrelación con otros procesos, definir las responsabilidades respecto al proceso, analizar y medir los resultados de la capacidad y eficacia del proceso y centrarse en los recursos y métodos que permiten la mejora del proceso. La propuesta diseñada propone el proceso de servicio posventa, así como los procedimientos, las responsabilidades, los indicadores, el planeamiento de la frecuencia de los mantenimientos preventivos que se deben cumplir por estar estipulados en los contratos administrativos (Licitaciones) durante el periodo de garantía de los equipos. / Tesis
2

Território usado e circuito superior marginal: equipamentos médico-hospitalares em Campinas, Ribeirão Preto e São José do Rio Preto (SP) / Used territory and upper circuit marginal: medical and hospital equipment in Campinas, Ribeirão Preto and São José do Rio Preto (SP)

David, Virna Carvalho 03 March 2011 (has links)
No contexto da especificidade da urbanização brasileira, onde as cidades crescem simultaneamente às formas de trabalho com capitais reduzidos e tecnologias menos modernas, nossa pesquisa analisa o território usado por diferentes agentes do sistema produtivo de equipamentos médicohospitalares no Estado de São Paulo, atentando para as diferentes divisões do trabalho existentes na forma dos circuitos da economia urbana. Valorizado de forma seletiva, o meio construído permite que atividades mais e menos rentáveis se instalem, enquanto a coexistência de divisões do trabalho que datam de diferentes épocas assegura uma dinâmica interdependente entre os circuitos da economia urbana. Neste sentido, discutimos a existência de um circuito superior marginal ligado às atividades de produção de equipamentos médicohospitalares em Campinas, Ribeirão Preto e São José do Rio Preto (SP) e o papel complementar que este cumpre para os serviços de saúde do país. / In the context of the specificity of Brazilian urbanization, where simultaneous with the growth of the cities, the types of work with reduced capital and less modern technologies also grow, our research analyses the territory used by different agents of the medicalhospital equipments production system in the state of São Paulo, looking at the different divisions of labor, existing in ways of the circuits of urban economy. Valued in a selective way, the environment building allows installation of more or less profitable activities, while the coexistence of divisions of labor of different ages ensures an interdependent dynamic among the circuits of the urban economy. In this way, we discuss the existence of a marginal upper circuit related to the medicalhospital equipments production in Campinas, Ribeirão Preto e São José do Rio Preto (SP) and its complementary function that it accomplishes for the brazilian health services.
3

Território usado e circuito superior marginal: equipamentos médico-hospitalares em Campinas, Ribeirão Preto e São José do Rio Preto (SP) / Used territory and upper circuit marginal: medical and hospital equipment in Campinas, Ribeirão Preto and São José do Rio Preto (SP)

Virna Carvalho David 03 March 2011 (has links)
No contexto da especificidade da urbanização brasileira, onde as cidades crescem simultaneamente às formas de trabalho com capitais reduzidos e tecnologias menos modernas, nossa pesquisa analisa o território usado por diferentes agentes do sistema produtivo de equipamentos médicohospitalares no Estado de São Paulo, atentando para as diferentes divisões do trabalho existentes na forma dos circuitos da economia urbana. Valorizado de forma seletiva, o meio construído permite que atividades mais e menos rentáveis se instalem, enquanto a coexistência de divisões do trabalho que datam de diferentes épocas assegura uma dinâmica interdependente entre os circuitos da economia urbana. Neste sentido, discutimos a existência de um circuito superior marginal ligado às atividades de produção de equipamentos médicohospitalares em Campinas, Ribeirão Preto e São José do Rio Preto (SP) e o papel complementar que este cumpre para os serviços de saúde do país. / In the context of the specificity of Brazilian urbanization, where simultaneous with the growth of the cities, the types of work with reduced capital and less modern technologies also grow, our research analyses the territory used by different agents of the medicalhospital equipments production system in the state of São Paulo, looking at the different divisions of labor, existing in ways of the circuits of urban economy. Valued in a selective way, the environment building allows installation of more or less profitable activities, while the coexistence of divisions of labor of different ages ensures an interdependent dynamic among the circuits of the urban economy. In this way, we discuss the existence of a marginal upper circuit related to the medicalhospital equipments production in Campinas, Ribeirão Preto e São José do Rio Preto (SP) and its complementary function that it accomplishes for the brazilian health services.
4

Propuesta de mejora de procesos en el área de servicio técnico de una empresa de venta de equipos médicos

Durand Yucra, Sara Pamela 04 November 2015 (has links)
La presente tesis se sustenta en los resultados obtenidos por el crecimiento de la necesidad del cliente por el servicio de mantenimiento en el área de Servicio Técnico, el cual no lo llega a satisfacer. Por lo tanto, se debe mejorar y optimizar los procesos de esta área de la empresa. El objetivo planteado consta de la propuesta de solución, para lo cual se realiza la mejora de los procesos administrativos y operativos del servicio de mantenimiento y se reducen todos los problemas que afectan el rendimiento del mismo. De acuerdo con el análisis, el diagnostico de los principales problemas es que la empresa está incurriendo en pérdidas económicas elevadas. La propuesta de solución contiene un plan de acción que consta de las siguientes actividades: reestructuración del área de Servicio Técnico y del sistema de control; el manual de procedimientos; la estandarización en los métodos de trabajo de mantenimiento; el plan estratégico para el proceso de compras de repuestos; la contratación de persona especializada en coordinación de mantenimientos; el programa de capacitación al personal del área y plan de comunicación interna. Finalmente, se propone evaluar la inversión inicial para la mejora del proceso y realizar una evaluación económica, lo que permite conocer si el proyecto es rentable y que el periodo de recuperación de inversión será en el tiempo proyectado.
5

Activation patterns in atrial fibrillation: contributions of body surface potential mapping

Guillem Sanchez, Maria De La Salud 07 January 2009 (has links)
La fibrilación auricular (FA) es una de las arritmias cardiacas más comunes, afectando a alrededor del 10 % de los mayores de 70 años. A pesar de su alta incidencia en la población, los mecanismos que desencadenan y mantienen la FA son inciertos. Aunque existen diversos tratamientos quirúrgicos y farmacológicos, el éxito de los tratamientos contra la FA es muy bajo. La causa de esta baja tasa de éxito de las diferentes terapias es que no existen criterios de selección de pacientes que permitan pronosticar qué terapia puede ser más efectiva para cada paciente. Una de las formas que se han propuesto para determinar el grado de gravedad de la arritmia en cada paciente y, por tanto, poder predecir qué tratamiento es el más apropiado es la medida de la organización auricular. Esta tesis doctoral se enmarca dentro de la determinación no invasiva del grado de organización espacial de la activación del miocardio auricular a partir del estudio de registros multiderivación del electrocardiograma de superficie (ECG). El ECG es una representación simplificada del campo eléctrico del corazón basada en las proyecciones de este campo eléctrico en 8 ejes. Esta simplificación es considerada como aceptable en el caso de ritmos no fibrilantes en los que la activación miocárdica puede ser modelada como un dipolo. Sin embargo, su validez no ha sido demostrada para el caso de ritmos fibrilantes en los cuales la asunción de un modelo dipolar es cuestionable. Uno de los objetivos de esta tesis ha sido la evaluación del electrocardiograma de superficie para la obtención de parámetros espaciales de las ondas de FA. Se compararon las representaciones tridimensionales de las ondas de FA registradas a partir de tres derivaciones ortogonales con las representaciones tridimensionales estimadas a partir del ECG, llegando a la conclusión de que estas representaciones estimadas no son fieles a las representaciones registradas. Los resultados de nuestro estudio ponen de manifiesto que la falta de d / Guillem Sanchez, MDLS. (2008). Activation patterns in atrial fibrillation: contributions of body surface potential mapping [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/3922 / Palancia
6

Signal processing of intracardiac recordings for the evaluation of propofol effects during atrial fibrillation

Cervigón Abad, Raquel 25 June 2009 (has links)
La fibrilación auricular es la arritmia más frecuente en la práctica clínica, con una prevalencia que alcanza el 10% en la población mayor de 70 años, y unas perspectivas de incremento en consonancia con el aumento de la esperanza de vida. No obstante, a pesar de ser la arritmia más frecuente, los mecanismos causantes de su generación y persistencia no se conocen con exactitud. Por esta razón, los estudios cuyo objetivo sea profundizar en los mecanismos que envuelven la citada arritmia son de gran ayuda para el desarrollo de protocolos clínicos que mejoren el diagnóstico, y permitan seleccionar los tratamientos más apropiados. Numerosos estudios científicos han indagado en cuáles son los factores que afectan al estado electrofisiológico de las aurículas, responsables de la iniciación y mantenimiento de la fibrilación, así como en los que gobiernan la transmisión de los impulsos eléctricos entre la aurícula y el ventrículo, donde el sistema nervioso autónomo se ha apuntado como uno de los factores responsables. En esta tesis doctoral se ha estudiado el efecto sobre la actividad auricular y ventricular, del anestésico más comúnmente usado en terapias destinadas a restablecer el ritmo sinusal en pacientes con episodios de fibrilación auricular. Este anestésico es el propofol (2,6-diisopropylphenol), que es un rápido anestésico intravenoso. La rápida redistribución y metabolismo del propofol resultan en una rápida eliminación de aproximadamente 1 hora, haciéndolo útil para sedaciones de corta duración. La hipótesis de este estudio es si el propofol puede alterar la actividad auricular durante la fibrilación auricular. Simultáneamente a la realización de los procedimientos de ablación, se realizan registros electrocardiográficos y electrogramas auriculares. Los electrogramas permiten extraer información local de las aurículas, muy útil para reflejar los procesos electrofisiológicos que ocurren durante la fibrilación auricular. Habitualmente, los registros internos de epi / Cervigón Abad, R. (2009). Signal processing of intracardiac recordings for the evaluation of propofol effects during atrial fibrillation [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/5766 / Palancia
7

Computational study in fluid mechanics of bio-inspired geometries: constricted channel and paediatric ventricular assist device. / Estudo computacional em mecânica de fluidos de geometrias bio-inspiradas: canal constrito e dispositivo de assistência ventricular pediátrico.

Isler, João Anderson 17 April 2018 (has links)
Numerical modelling and simulation are powerful tools for analysis and design, and with the improvement of computational power and numerical methods they are being applied on complex phenomena and systems. This work shows examples of the application of a very sophisticated numerical method, namely the Spectral/hp element method, in the study of the flow inside bioinspired complex geometries. The two topics investigated are fluid dynamic instabilities in a constricted channel and flow inside a paediatric ventricular assist device were studied by means of computational fluid mechanics. The constricted channel is an idealized model of a nasal cavity, which is characterized by complex airway channels, and also bears some resemblance to a human artery in the presence of an atherosclerotic plaques. The paediatric ventricular assist device is an actual device, designed by the Bioengineering research group of the Heart Institute of the Medicine School of the University of São Paulo, which works as a pump that assists the left ventricle of patients waiting for transplantation. Therefore, the aim of this thesis is to contribute in the understanding of biological and bio-inspired geometries flows, using computational tools. Linear and nonlinear stability were carried out for the constricted channel. Three different flow regimes were investigated: symmetric steady flow, which is stable for low Reynolds number, asymmetric steady flow, which rises as a result of the primary bifurcation of the symmetric flow and pulsatile flow. Direct stability analysis was carried out to determine the unstable regions and the critical values for each flow regime. The physical mechanisms behind the transition processes were studied by means of direct numerical simulations to characterize the bifurcations. Since the bifurcations had subcritical behaviour, the relevance of non-normal growth in these flows was assessed. Dependence on phase, Reynolds number and spanwise wavenumber of optimal modes were extensively investigated in stable regions of the three flow regimes. Convective instabilities were also studied in order to comprehend the physical mechanisms which led the optimal modes to their maxima growth, and different convective mechanisms were found. The flow inside the paediatric ventricular assist device was analyzed by means of threedimensional numerical simulations. A computational model based on special boundaries conditions was developed to model the pulsatile flow. In this model, the opening and closure of the mitral valve and diaphragm were represented with the use of specially devised boundary conditions. The driving force and the flow direction of the diaphragm were defined by velocity distribution on the diaphragm wall, and the opening and closure of the mitral valve were performed by a velocity waveform which goes to zero in the systolic period. Flow patterns, velocity fields and time-average wall shear rate were analyzed to evaluate the performance of the device. / Modelagem e simulação numéricas são ferramentas poderosas para análise e design, e com a melhoria do poder computacional e dos métodos numéricos, eles estão sendo aplicados em fenômenos e sistemas complexos. Este trabalho mostra exemplos de aplicações de um método numérico sofisticado, o método dos elementos espectrais/hp, no estudo do escoamento dentro de geometrias complexas bio-inspiradas. Os dois tópicos investigados são: instabilidades em dinâmica de fluido em um canal constrito e o escoamento dentro de um dispositivo de assistência ventricular pediátrica. O canal constrito é um modelo idealizado de uma cavidade nasal, que é caracterizada por canais complexos da via aérea, e também tem semelhança com uma artéria humana na presença de placas ateroscleróticas. O dispositivo de assistência ventricular pediátrica é um dispositivo real, projetado pelo grupo de pesquisa de Bioengenharia do Instituto do Coração da Faculdade de Medicina da Universidade de São Paulo, que funciona como uma bomba que auxilia o ventrículo esquerdo dos pacientes à espera de transplante. Portanto, o objetivo desta tese é contribuir na compreensão de escoamentos em geometrias biológicas e bio-inspiradas, usando ferramentas computacionais. Análises de estabilidade linear e não linear foram feitas para um canal constrito. Três diferentes regimes de escoamento foram empregados: escoamento estacionário simétrico, que é estável para baixo número de Reynolds, escoamento assimétrico, o qual é resultado da primeira bifurcação do escoamento simétrico e escoamento pulsátil. Análise de estabilidade direta foi executada para determinar as regiões instáveis em cada regime de escoamento. Os mecanismos físicos por trás do processo de transição foram estudados por meio de simulação numérica direta para caracterizar as bifurcações. Uma vez que, as bifurcações tiveram um comportamento subcrítico, a relevância do crescimento não normal nestes escoamentos foi avaliado. Assim, dependência com a fase, número de Reynolds e número de onda do modo tridimensional foram extensivamente investigados em regiões estáveis para os três regimes de escoamento. Instabilidades convectivas foram também estudadas a fim de compreender os mecanismos físicos que conduzem os modos ótimos para seus crescimentos máximos, e diferentes mecanismos convectivos foram encontrados. O escoamento dentro do dispositivo de assistência ventricular pediátrico foi analisado por meios de simulações numéricas tridimensionais. Um modelo computacional baseado em condições de contorno especiais foi desenvolvido para modelar o escoamento pulsátil. Neste modelo, a abertura e fechamento da válvula mitral e diafragma foram representados com o uso de condições de contorno especialmente elaboradas. A força motora e o direcionamento do fluxo do diafragma foram definidos por uma distribuição de velocidades na parede do diafragma, e a abertura e fechamento da válvula mitral foram executadas por uma função de onda de velocidade que vai a zero no período sistólico. Padrões do escoamento, campos de velocidade e tensão de cisalhamento no tempo foram analisadas para avaliar o desempenho do dispositivo.
8

Desenvolvimento de um protótipo para monitoração de saturação de oxigênio e freqüência cardíaca para roedores. / Development of a oxigen saturation and cardiac frequency prototype for rodents.

Vilhegas, Leonardo Zane 12 December 2007 (has links)
A utilização de equipamentos para monitoração de parâmetros fisiológicos não é apenas crucial em pacientes que são submetidos a alguns procedimentos médicos, mas é também de extremo valor para animais em uso similar. Este projeto tem como principal objetivo o desenvolvimento de um sistema de monitoração de saturação de oxigênio e freqüência cardíaca para roedores; tal sistema é composto por um dispositivo protótipo compacto e sensor óptico. No presente trabalho, foram utilizadas as tecnologias dos microcontroladores da Microchip para realizar as diversas digitalizações; a tecnologia USB, para realizar a comunicação com computadores e o desenvolvimento da interface desenvolvida com o software disponível da National Instruments, o LabVIEW. Neste estudo, o sistema desenvolvido foi empregado em camundongos e foram realizadas diversas avaliações em laboratório e em campo para a validação do dispositivo protótipo. Os batimentos cardíacos e a saturação de oxigênio, tanto em repouso quanto em movimento, foram detectados pelo protótipo. Os valores de freqüência cardíaca variaram entre 545 e 700 bpm enquanto os valores de saturação de oxigênio variaram entre 80 a 95%. / The equipments use to monitoring physiological parameters isnt just crucial in patients who are submitted to some medical procedures but it is also of extreme value for animals in similar use. This project has as main objective the development of a monitor oxygen saturation and cardiac frequency for mice; the system is compound of a compact prototype device and optic sensor. In the present work, the Microchip microcontrollers technologies had been used, to realize many digitalization; the USB technology interface, to realize the communication with computers and the interface development developed with the available National Instruments software, the LabVIEW. In this study, the developed system was used in mice and have been realized many evaluations in laboratory and field for the prototype validation device. The cardiac beatings and oxygen saturation, as much in rest how in movement they had been detected by the prototype. The values of heart rate had varied of 545 to 700 while the values of oxygen saturation had varied of 80 to 95%.
9

Desenvolvimento de um protótipo para monitoração de saturação de oxigênio e freqüência cardíaca para roedores. / Development of a oxigen saturation and cardiac frequency prototype for rodents.

Leonardo Zane Vilhegas 12 December 2007 (has links)
A utilização de equipamentos para monitoração de parâmetros fisiológicos não é apenas crucial em pacientes que são submetidos a alguns procedimentos médicos, mas é também de extremo valor para animais em uso similar. Este projeto tem como principal objetivo o desenvolvimento de um sistema de monitoração de saturação de oxigênio e freqüência cardíaca para roedores; tal sistema é composto por um dispositivo protótipo compacto e sensor óptico. No presente trabalho, foram utilizadas as tecnologias dos microcontroladores da Microchip para realizar as diversas digitalizações; a tecnologia USB, para realizar a comunicação com computadores e o desenvolvimento da interface desenvolvida com o software disponível da National Instruments, o LabVIEW. Neste estudo, o sistema desenvolvido foi empregado em camundongos e foram realizadas diversas avaliações em laboratório e em campo para a validação do dispositivo protótipo. Os batimentos cardíacos e a saturação de oxigênio, tanto em repouso quanto em movimento, foram detectados pelo protótipo. Os valores de freqüência cardíaca variaram entre 545 e 700 bpm enquanto os valores de saturação de oxigênio variaram entre 80 a 95%. / The equipments use to monitoring physiological parameters isnt just crucial in patients who are submitted to some medical procedures but it is also of extreme value for animals in similar use. This project has as main objective the development of a monitor oxygen saturation and cardiac frequency for mice; the system is compound of a compact prototype device and optic sensor. In the present work, the Microchip microcontrollers technologies had been used, to realize many digitalization; the USB technology interface, to realize the communication with computers and the interface development developed with the available National Instruments software, the LabVIEW. In this study, the developed system was used in mice and have been realized many evaluations in laboratory and field for the prototype validation device. The cardiac beatings and oxygen saturation, as much in rest how in movement they had been detected by the prototype. The values of heart rate had varied of 545 to 700 while the values of oxygen saturation had varied of 80 to 95%.
10

Computational study in fluid mechanics of bio-inspired geometries: constricted channel and paediatric ventricular assist device. / Estudo computacional em mecânica de fluidos de geometrias bio-inspiradas: canal constrito e dispositivo de assistência ventricular pediátrico.

João Anderson Isler 17 April 2018 (has links)
Numerical modelling and simulation are powerful tools for analysis and design, and with the improvement of computational power and numerical methods they are being applied on complex phenomena and systems. This work shows examples of the application of a very sophisticated numerical method, namely the Spectral/hp element method, in the study of the flow inside bioinspired complex geometries. The two topics investigated are fluid dynamic instabilities in a constricted channel and flow inside a paediatric ventricular assist device were studied by means of computational fluid mechanics. The constricted channel is an idealized model of a nasal cavity, which is characterized by complex airway channels, and also bears some resemblance to a human artery in the presence of an atherosclerotic plaques. The paediatric ventricular assist device is an actual device, designed by the Bioengineering research group of the Heart Institute of the Medicine School of the University of São Paulo, which works as a pump that assists the left ventricle of patients waiting for transplantation. Therefore, the aim of this thesis is to contribute in the understanding of biological and bio-inspired geometries flows, using computational tools. Linear and nonlinear stability were carried out for the constricted channel. Three different flow regimes were investigated: symmetric steady flow, which is stable for low Reynolds number, asymmetric steady flow, which rises as a result of the primary bifurcation of the symmetric flow and pulsatile flow. Direct stability analysis was carried out to determine the unstable regions and the critical values for each flow regime. The physical mechanisms behind the transition processes were studied by means of direct numerical simulations to characterize the bifurcations. Since the bifurcations had subcritical behaviour, the relevance of non-normal growth in these flows was assessed. Dependence on phase, Reynolds number and spanwise wavenumber of optimal modes were extensively investigated in stable regions of the three flow regimes. Convective instabilities were also studied in order to comprehend the physical mechanisms which led the optimal modes to their maxima growth, and different convective mechanisms were found. The flow inside the paediatric ventricular assist device was analyzed by means of threedimensional numerical simulations. A computational model based on special boundaries conditions was developed to model the pulsatile flow. In this model, the opening and closure of the mitral valve and diaphragm were represented with the use of specially devised boundary conditions. The driving force and the flow direction of the diaphragm were defined by velocity distribution on the diaphragm wall, and the opening and closure of the mitral valve were performed by a velocity waveform which goes to zero in the systolic period. Flow patterns, velocity fields and time-average wall shear rate were analyzed to evaluate the performance of the device. / Modelagem e simulação numéricas são ferramentas poderosas para análise e design, e com a melhoria do poder computacional e dos métodos numéricos, eles estão sendo aplicados em fenômenos e sistemas complexos. Este trabalho mostra exemplos de aplicações de um método numérico sofisticado, o método dos elementos espectrais/hp, no estudo do escoamento dentro de geometrias complexas bio-inspiradas. Os dois tópicos investigados são: instabilidades em dinâmica de fluido em um canal constrito e o escoamento dentro de um dispositivo de assistência ventricular pediátrica. O canal constrito é um modelo idealizado de uma cavidade nasal, que é caracterizada por canais complexos da via aérea, e também tem semelhança com uma artéria humana na presença de placas ateroscleróticas. O dispositivo de assistência ventricular pediátrica é um dispositivo real, projetado pelo grupo de pesquisa de Bioengenharia do Instituto do Coração da Faculdade de Medicina da Universidade de São Paulo, que funciona como uma bomba que auxilia o ventrículo esquerdo dos pacientes à espera de transplante. Portanto, o objetivo desta tese é contribuir na compreensão de escoamentos em geometrias biológicas e bio-inspiradas, usando ferramentas computacionais. Análises de estabilidade linear e não linear foram feitas para um canal constrito. Três diferentes regimes de escoamento foram empregados: escoamento estacionário simétrico, que é estável para baixo número de Reynolds, escoamento assimétrico, o qual é resultado da primeira bifurcação do escoamento simétrico e escoamento pulsátil. Análise de estabilidade direta foi executada para determinar as regiões instáveis em cada regime de escoamento. Os mecanismos físicos por trás do processo de transição foram estudados por meio de simulação numérica direta para caracterizar as bifurcações. Uma vez que, as bifurcações tiveram um comportamento subcrítico, a relevância do crescimento não normal nestes escoamentos foi avaliado. Assim, dependência com a fase, número de Reynolds e número de onda do modo tridimensional foram extensivamente investigados em regiões estáveis para os três regimes de escoamento. Instabilidades convectivas foram também estudadas a fim de compreender os mecanismos físicos que conduzem os modos ótimos para seus crescimentos máximos, e diferentes mecanismos convectivos foram encontrados. O escoamento dentro do dispositivo de assistência ventricular pediátrico foi analisado por meios de simulações numéricas tridimensionais. Um modelo computacional baseado em condições de contorno especiais foi desenvolvido para modelar o escoamento pulsátil. Neste modelo, a abertura e fechamento da válvula mitral e diafragma foram representados com o uso de condições de contorno especialmente elaboradas. A força motora e o direcionamento do fluxo do diafragma foram definidos por uma distribuição de velocidades na parede do diafragma, e a abertura e fechamento da válvula mitral foram executadas por uma função de onda de velocidade que vai a zero no período sistólico. Padrões do escoamento, campos de velocidade e tensão de cisalhamento no tempo foram analisadas para avaliar o desempenho do dispositivo.

Page generated in 0.0899 seconds