• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Synergie des capteurs spatiaux européens OLCI-SLSTR pour l’étude à long terme de la couleur des eaux côtières / Synergy of OLCI-SLSTR european space-borne sensors for long term study of the color of coastal waters

Mograne, Mohamed Abdelillah 27 June 2019 (has links)
La télédétection spatiale de la couleur de l’océan implique l’élimination de la contribution atmosphérique, appelée correction atmosphérique (CA). Au-dessus des eaux claires, cette dernière se base sur l’hypothèse que l’eau est totalement absorbante dans le Proche Infra-Rouge (PIR) pour estimer la réflectance atmosphérique et déterminer la réflectance marine. À l’opposé, au-dessus des eaux côtières turbides, la contribution du signal marin n’est pas négligeable dans le PIR. De ce fait, différentes méthodes alternatives ont été proposées. La thèse se consacre à l’évaluation des algorithmes de CA proposés et leur amélioration pour le capteur Ocean and Land Colour Instrument (OLCI) au-dessus des eaux côtières en exploitant sa synergie avec le capteur Sea and Land Surface Temperature Radiometer (SLSTR). Dans ce but, des mesures radiométriques in-situ ont été acquises dans deux zones côtières françaises contrastées : Manche orientale et Guyane Française, avec le spectro-radiomètre ASD, suivant un nouveau protocole d’acquisition et de post-traitement. Le post-traitement s’est basé sur le coefficient de variabilité et la différence relative de la médiane dans le contrôle de qualité, en plus du score d’assurance de qualité (QAS). Suivant l’analyse statistique basée en partie sur l’angle spectral moyenné (SAM), l’inter-comparaison radiométrique de l’ASD avec les autres radiomètres (TriOS-above et Radeau), a révélé la cohérence des mesures ASD. L’utilisation de ces dernières a permis l’inter-comparaison de la performance de cinq algorithmes de CA, où l’algorithme Polymer est le plus performant d’après un système à points avec une seule métrique. Cependant aucun algorithme a atteint le maximum de points soulignant la grande marge de progression à accomplir, surtout en eau côtière. Dans cette optique, trois relations spectrales de la réflectance des aérosols ont été testées sur une base de données simulées suivant la synergie OLCI/SLSTR. Une autre relation, Full Spectrum AC (FSAC) a été développée initialement en combinant deux relations existantes, après l’élimination de l’hypothèse du pixel noir dans l’ultra-violet (UV) et l’intégration d’un schéma itératif. L’inter-comparaison des relations révèle la cohérence de FSAC qui est légèrement moins performante qu’une relation publiée. L’application de FSAC sur des images OLCI/SLSTR ouvrirait des perspectives dans l’amélioration de la CA au-dessus des eaux côtières. / The ocean color remote sensing involves the removal of the atmospheric contribution, the so-called atmospheric correction (AC). Over clear waters, the latter is based on the hypothesis that the sea water is totally absorbent in the Near Infra-Red (NIR), to estimate the atmospheric reflectance and to determine the water reflectance. By contrast, over coastal turbid waters, the marine signal is not negligible in the NIR. Accordingly, different alternative methods were proposed. The thesis is committed to evaluate the proposed AC algorithms and their improvement for the Ocean and Land Colour Instrument (OLCI) sensor over coastal waters exploiting its synergy with the Sea and Land Surface Temperature Radiometer (SLSTR) sensor. For this purpose, radiometric in-situ measurements were acquired in two contrasted French coastal areas : Eastern English Channel and FrenchGuiana, with the ASD spectro-radiometer, according to a newly developed measurement and post-processing protocol. The post-processing was based on the coefficient of variability and the median relative difference, in addition to the Quality Assurance Score (QAS). Following the statistical analysis in part based on the Spectral Angle Mean (SAM), the radiometric inter-comparison of the ASD and other radiometers (TriOS-above and TriOS in-water), shows the consistency of the ASD measurements. The use of these measurement leads to carry out the performance inter-comparison of five AC algorithms, where the Polymer algorithm is the most efficient according to a unique metric scoring system. However, neither algorithm obtained the maximum score, highlighting the big room for improvement, especially for coastal waters. With this in mind; three spectral relationships of aerosols reflectance were tested with a simulated data set based on OLCI/SLSTR synergy. Another relationship, Full Spectrum AC (FSAC) was initially developed combining two existing relationships, after excluding the black pixel hypothesis in the Ultra-Violet and integrating a iterative scheme. The relationships inter-comparison shows consistency ofFSAC which is slightly less performing than one published relationship. The application of FSAC on OLCI/SLSTR images could have perspectives to improve the AC over coastal waters.
2

Modélisation de la compliance de l'aorte dans le cas de pathologies de type anévrisme / The compliance modelling of the pathology aorta of the type of aneurism

Wang, Yufei 06 November 2015 (has links)
L’Anévrisme de l’Aorte Abdominale (AAA) est une pathologie qui est définie par une dilatation localisée et permanente de l’artère et qui concerne plus de 8.8% des personnes âgées. Actuellement, lorsqu’un patient présente une dilatation de l’aorte impliquant l’éventualité d’une intervention chirurgicale en raison du risque de rupture, la décision thérapeutique est prise en fonction du rapport des diamètres de l’artère au niveau de l’anévrisme et à proximité de celui-ci. Pour déterminer ces diamètres, il est généralement procédé à un examen par imagerie médicale (Echographie, Tomographie, IRM,..). On constate cependant que le diagnostic ne peut pas se contenter d’une mesure dimensionnelle simple face aux risques induits: d’une part, passé une certaine excroissance, le risque de rupture peut atteindre 50% mais d’autre part plus de 5% des interventions chirurgicales provoquent le décès du patient. D’autres paramètres de mesure comme la compliance de l’artère, peuvent être à la base de la décision d’une intervention chirurgicale. La compliance correspond à une définition précise utilisée par les cardiologues : c’est une grandeur qui permet de caractériser l’aptitude à la déformation, décrivant la capacité de l'aorte à se distendre sous l'influence de la pression sanguine. De notre point de vue cette notion est insuffisante car, généralement, dans le cas d’un anévrisme, la rupture est très localisée du fait de la complexité de la forme de celui-ci. Il est donc nécessaire d’étendre sa définition à une grandeur localisée non pas au niveau d’une section mais à un endroit précis de la paroi. Les moyens de diagnostics seront d’autant plus fiables qu’ils pourront détecter la compliance localisée. De point de vue mécanique, la détermination de la compliance se transforme donc en la mesure de l'élasticité pariétale aortique localisée. L’élasticité n’est pas un paramètre mesurable directement. Donc, la problématique revient à la détermination de la déformation locale de la paroi aortique sous la sollicitation hémodynamique. La résolution de ce problème reste complexe. En effet, les sollicitations mécaniques dépendent de l’écoulement du sang, des organes environnants l’artère, des propriétés matérielles de l’artère et de la géométrie de l’anévrisme qui sont spécifiques à chaque patient. A l’heure actuelle, beaucoup de travaux numériques et expérimentaux sont effectués mais peu d’études ont permis de bien corréler les techniques d’imageries médicales pour l’aide au diagnostic. C’est dans ce contexte que se situent les travaux de ma thèse, réalisée en collaboration, à la fois avec le CHU de Dijon où ont été effectuées toutes les expérimentations à l’aide d’IRM, le laboratoire GMedTech, GMIT (Galway-Mayo Institute of Technology) en Irlande qui nous a fourni les répliques ainsi que leur savoir-faire dans le domaine cardio-vasculaire et le Laboratoire DRIVE situé à Nevers où ont été menées les mesures d’écoulement par PIV. Les travaux, menés sur des fantômes de diverses formes in vitro, ont pour finalité, d’une part, de construire une méthodologie métrologique pour aider les médecins à comprendre et à valider les mesures d’IRM à l’aide d’autres dispositifs de mesure, d’autre part, de permettre d’améliorer les méthodes de diagnostic des pathologies de type d’anévrisme de l’aorte abdominale. Le principe de ces travaux est donc de mettre en place une modélisation expérimentale in Vitro dans un cadre métrologique d’intercomparaison par divers moyens de mesure et de corréler leurs résultats au long d’un cycle reproduisant les conditions hémodynamiques de mesure, mais aussi de confronter ces résultats à de modélisations numériques. Pour prendre en compte le problème dans sa globalité, non seulement l’évolution de la déformation, représentant l’élasticité de l’aorte, a dû être étudiée mais aussi l’évolution du flux sollicitant la paroi (…). / The Abdominal Aorta Aneurysm (AAA) is a pathology that is defined by a localized and permanent dilation of the artery and which involves over 8.8% of the seniors. Currently, when a patient has a dilatation of the aorta leading to a surgery because of the rupture risk, the therapeutic decision is made depending on the diameter of the aneurysm. To determine this diameter, it is usually conducted an examination by medical imaging (ultrasound, CT, MRI...). However, it notes that the diagnosis can’t be satisfied with a single dimensional measurement face to induced risks: first of all, when the diameter exceed a certain growth, the risk of rupture can reach 50% but more than 5% of surgical procedures may cause the patient's death. Other metrics such as compliance of the artery can be used for the decision for surgery. Compliance corresponds to a precise definition by cardiologists: this is a quantity that characterizes the deformability, describing the ability of aorta to distend under the influence of blood pressure. From our point of view, this concept is insufficient because, generally, in the case of an aneurysm, rupture is highly localized because of the complexity of the shape. It is therefore necessary to extend its definition in a quantity not localized at a section or a specific location but to the whole wall. Diagnostics methods will be more reliable if they can determine localized compliance. From a mechanical standpoint, determining compliance is thus transformed into the measurement of localized parietal elasticity of aorta. The elasticity is not a directly measurable parameter. Therefore, the problem comes down to determining the local strain of the aortic wall in the hemodynamic condition. Solving this problem is complex. Indeed, the mechanical stresses are dependent on the flow of blood, the artery surrounding organs, the material properties of the artery and the geometry of the aneurysm which are specific to each patient. At present, many numerical and experimental works is done but few studies have well correlated medical imaging techniques for the diagnostic aid. It is in this context that are my thesis in collaboration both with the Dijon University Hospital where were performed all experiments using MRI and GMedTech laboratory GMIT (Galway- Mayo Institute of Technology) in Ireland who provided the replicas and their expertise in the cardiovascular area. This work, conducted on various form of phantoms in Vitro, are intended, first to build a metrological methodology to help doctors understand and validate MRI measurements using other devices measurement, on the other hand, to improve the methods of diagnosing the abdominal aortic aneurysm. The principle of this work is to develop experimental modeling in vitro in a metrology framework and correlate the results from different measurement techniques and numerical modeling throughout a cycle reproducing the hemodynamic conditions. To consider the problem as a whole, not only the evolution of deformation representing the elasticity of the aorta should be studied, but also the evolution of soliciting flow. Therefore, in this thesis, several devices such as stereovision, Particle image velocimetry (PIV), MRI kinetic sequence but also the flow 2D and 4D were employed. Various numerical models were established to not only correlate the results with those obtained experimentally, therefore, to improve the credibility of our study, but also to be part of the aid protocol to the diagnosis that we have proposed. In the end, all the results from different experimental and numerical models have led to propose a validated and feasible diagnosis protocol based on MRI sequences. The application of this protocol on a realistic AAA complex phantom showed its feasibility. We can therefore say that the feasibility of the proposed protocol is demonstrated and that based on MRI (…).
3

LM-PAFOG : a new three-dimentional fog forecast model with parametrised microphysics

Masbou, Matthieu 22 July 2008 (has links) (PDF)
La présence de brouillard occasionne des perturbations des transports aériens et routiers et peut être à l'origine d'accidents graves. Cependant, le brouillard est en général un phénomène de petite échelle, influencé aussi bien par les transports advectifs locaux, les échanges turbulents que par sa structure microphysique. Une paramétrisation microphysique basée sur le modèle unidimensionnel de prévision du brouillard, PAFOG, a été introduite dans le modèle méso-échelle tridimensionnel,"Lokal Model". L'évaluation des prévisions de LM-PAFOG montre la dispersion des performances du modèle entre les périodes de jour et de nuit. Des comparaisons avec d'autres systèmes de prévision du brouillard pointent l'influence d'un schéma d'assimilation adapté, ainsi que celle de la paramétrisation de la visibilité. Enfin, un schéma de vérification utilisant des produits satellites pour le brouillard et les stratus bas a été testé.
4

MODÉLISATION DE L'ECOULEMENT DES GLACIERS TEMPÉRÉS

Schäfer, Martina 11 September 2007 (has links) (PDF)
Des aspects variés de la modélisation de l'écoulement glaciaire sont abordés. <br />Le modèle de Le Meur et Vincent (2003) est utilisé à plusieurs reprises. Plusieurs améliorations sont effectuées (conservation de la masse, traitement des épaisseurs négatives, traitement de la glace située en amont de la rimaye).<br />Sur le glacier de St. Sorlin (France) une comparaison entre le champ de bilan issu des mesures et celui issu d'un modèle est effectuée. Le comportement du glacier sous un scénario climatique futur est prédit.<br />Une intercomparaison entre différents types de modèles est effectuée avec pour objectif la détermination du type de modèle le plus approprié en fonction du type de glacier. Les modèles testés sont le modèle SIA de Le Meur et Vincent (2003), le modèle SIA et le modèle d'ordre supérieur de Pattyn (2003) et un modèle Full Stokes (Elmer). Des géométries synthétiques sont utilisées ainsi qu'un cas réel. Les tests synthétiques montrent les limites de l'applicabilité de la SIA. Par contre, une comparaison rapide montre le gain considérable en temps CPU. D'un autre côté, l'augmentation du coût en terme de temps CPU ne s'avère pas très importante lors du passage d'un modèle d'ordre supérieur à un modèle Full Stokes.<br />Les simulations effectuées sur le glacier de St. Sorlin donnent un aperçu des limites de la validité de la SIA sur ce glacier. Même si elle reproduit globalement l'évolution observée du glacier, elle ne reproduit pas correctement le champ de vitesse ni certaines structures de la géométrie.<br />Les simulations sont comparées avec les observations pour la position du front et les vitesses de surface. <br />Un dernier chapitre est consacré au glacier Cotopaxi (Andes).
5

Développement de nouvelles méthodologies de traitement des signaux analytiques : application aux signaux chromatographiques. Analyse de mélanges complexes

Korifi, Rabia 29 May 2013 (has links)
Cette thèse porte sur la création d'un système expert d'alignement automatique des signaux chromatographiques répondant à une problématique de dérives et de décalages de signaux rencontrée dans l'inter-comparaison de données en milieu évolutif. Après un état de l'art des différentes méthodes d'alignement qui existent dans la littérature, les performances des méthodes librement disponibles ont été testées sur des jeux de données chromatographiques simulées et réelles. A l'issu de ce travail méthodique, il s'est avéré qu'aucune des méthodes n'apportait pleinement satisfaction en matière de performances définies dans le cahier des charges. Ainsi, une optimisation de la meilleure de ces méthodes d'alignement a été développée afin qu'elle puisse être annexée à un logiciel d'acquisition et de traitement de données chromatographiques. La dernière partie de ce manuscrit traite d'une problématique complémentaire, la conformité des échantillons en terme de contrôle qualité. La similitude des pics est évaluée selon des critères développés et validés par une exploitation manuelle des données. / This thesis focuses on the creation of an expert system for automatic alignment of chromatographic signals in response to a problem of drifts and shifts of signals encountered in the inter-comparison of data in evolving environment. After a state of the art of the different alignment methods that exist in the literature, the performances of freely available methods were tested on sets of simulated and real chromatographic data. At the end of this methodical work, it turned out that none of the methods did not provide fully satisfactory in terms of performance defined in the specification. Thus, an optimization of the best alignment method has been developed so that it can be attached to a software acquisition and processing of chromatographic data. The last part of this thesis deals with a complementary problem, the conformity of the samples in terms of quality control. The similarity of the peaks is evaluated according to criteria developed and validated by manual operation data.
6

Utilisation des modèles NTCP et de carcinogenèse pour les choix balistiques et de particules en hadronthérapie de l'adulte et de l'enfant

Boudam, Yasid 21 November 2008 (has links) (PDF)
Certains problèmes scientifiques et techniques, imparfaitement résolus dans la mise en œuvre des traitements par ions légers ont été étudiés. La thèse développe successivement les trois approches suivantes :<br />1) La première partie de cette thèse travaille sur la définition de l'équipement (faisceaux fixes versus gantry) pour un centre de traitement et ainsi traiter la plus large variété possible de tumeurs pour un spectre élargi de situations cliniques caractéristiques chez l'adulte. Les tumeurs étudiées sont des tumeurs de la base du crâne, du rachis cervical haut, bronchiques, ganglionnaires thoraciques, ganglionnaires abdominales et de la prostate, l'on obtient ainsi un éventail assez large d'indications thérapeutiques. <br />2) La seconde partie met à contribution une partie des outils développés dans la première phase (traitement chez l'adulte). Le même design de salle de traitement est utilisé mais pour un ensemble de tumeurs intracrâniennes de la base du crâne et de la sphère ORL chez l'enfant et l'adulte jeune. <br />Il peut être conclu que l'étude de multiples situations anatomo-pathologiques en thérapie protons n'a pas permis de dégager d'incidences faisceaulogiques originales et particulières à la gantry. <br />3) La dernière phase donne lieu à l'étude des caractéristiques physiques propres aux faisceaux d'ions carbones. Une comparaison est menée sur la base de simulations de données par l'utilisation de modèles de calcul du risque d'induction néoplasique après traitement chez l'adulte et plus spécifiquement chez l'enfant. La simulation semble indiquer que les ions carbones induiraient un phénomène de stérilisation cellulaire à doses intermédiaires & hautes dans les tissus & organes chez l'adulte et l'enfant.

Page generated in 0.0481 seconds