• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribution à la mise en place d’un microscope à force Atomique métrologique (mAFM) : Conception d’une tête AFM métrologique et caractérisation métrologique de l’instrument. / Contribution to the development of metrological atomic force microscope (mAFM) : design of a metrological AFM head and metrological caracterization of the instrument

Boukellal, Younes 02 April 2015 (has links)
Les microscopes en champ proche sont très largement utilisés pour caractériser des propriétés physiques à l’échelle du nanomètre. Afin d’assurer la cohérence et l’exactitude des mesures dimensionnelles qu’ils retournent, ces microscopes ont besoin d’être étalonnés périodiquement. Le raccordement à la définition du mètre SI est assuré par le biais d’étalons de transfert dont les caractéristiques dimensionnelles sont étalonnées à l’aide d’un Microscope à Force Atomique métrologique (mAFM).Les travaux de thèse portent sur la contribution à la mise en place du Microscope à Force Atomique métrologique du LNE dans le but de caractériser et réduire l’incertitude de mesure. Une tête AFM passive thermiquement et spécifiquement conçue pour des applications de nanométrologie dimensionnelle a été développée et intégrée au mAFM. Elle comporte un système original pour mesurer les déflexions du levier nécessaire à la détection des forces s’exerçant à l’extrémité de la pointe. Il utilise une évolution de la méthode du levier optique qui permet de déporter les sources de chaleurs à l’extérieur de l’instrument. Pour cela, un nouveau capteur a été développé. Il est basé sur l’utilisation d’un bundle composé de 40 000 microfibres optiques structurées en quatre quadrants. Il remplace avantageusement une photodiode quatre quadrants et permet de transporter le signal lumineux jusqu’à des photodiodes placées à l’extérieur de l’instrument. Ce système a été modélisé, caractérisé et validé expérimentalement. La tête AFM ainsi développée est passive thermiquement. Sa conception repose sur la dissociation complète de la chaine métrologique, constituée en Zerodur, afin de lui conférer une excellente stabilité thermique et mécanique. Pour les mêmes raisons, le châssis de la tête qui supporte l’ensemble des composants et notamment le système de mesure des déflexions du levier est entièrement conçu en Invar. Cette tête repose sur une structure motorisée constituée de trois moteurs à reptation permettant l’approche de pointe mais également le réglage des interféromètres. Après intégration de la tête dans le mAFM, l’ensemble de l’instrument a été caractérisé afin d’établir son bilan d’incertitude. Plusieurs composantes ont ainsi été évaluées expérimentalement comme la non-linéarité et la stabilité de la mesure de position par interférométrie, les rotations parasites du scanner, les erreurs d’Abbe, les défauts de rugosité et de planéité des miroirs ainsi que les erreurs de bras mort. L’impact de chaque composante a été quantifié et listé dans le bilan d’incertitude. Ces travaux ont permis d’avoir une première estimation de l’incertitude de mesure du mAFM. / Scanning probe microscopes are very well used for characterization at the manometer scale. To ensure the measurement coherency and the accuracy of the results, those microscopes need to be periodically calibrated. It’s done thanks to reference standards whose dimensional characteristics are measured by a metrological atomic force microscope (mAFM) for example.The aim of this thesis work is the improvement of the metrological AFM of the LNE in order to reduce the measurement uncertainty. To reach this goal, a thermally passive AFM head has been developed and integrated on the instrument. It contains an original system to measure the cantilever deflexion and thus detect the force acting between the sample and the tip. This system is based on the optical beam deflection method but allow deporting the heat sources outside the instrument. To reach this goal, a new specific sensor has been developed. It is based on a four quadrant optic fibre bundle that contains 40 000 micro-fibre and which is ideal to replace the existing four quadrant photodiode and its conditioning electronic circuit with the bundle and its conditioning electronic circuit placed outside the instrument. This sensor has been modelled, and experimentally validated.The Developed AFM head which integrates the deflection measurement system is then thermally passive. Its design is based on the complete dissociation of the metrological loop and the structural loop. The metrological loop is made of Zerodur® in other to acquire an excellent mechanical and thermal stability and thus reduce the thermal dilatation. For the same reason, the AFM head support frame is fully made of Invar. The AFM head is placed on a motorized frame based on three piezo-leg motors (tripod) to make the tip/sample approach but also to set the interferometer signal quality. The interferometer signal is improved by combining the linear displacements of the three motors to generate small rotations. This allows setting the parallelism of the mirrors linked to the head with those linked to the translation stage.Once the AFM head integrated on the instrument, the assembly is characterized in order to establish the uncertainty budget. Different uncertainty components have been experimentally evaluated as for example: the interferometer non linearity, the drift of the XYZ position, the parasitic rotations of the translation stage, the Abbe error, the roughness and the flatness of the mirrors and the dead path errors. The impact of the each component has been quantified and listed in the uncertainty budget. This allowed getting a first estimation of the combined uncertainty of the instrument.
2

Propagation of atoms in a magnetic waveguide on a chip / Propagation d'atomes dans un guide magnétique sur puce

Bade, Satyanarayana 18 November 2016 (has links)
Dans cette thèse, nous étudions la propagation des atomes dans un guide magnétique toroïdal, dans le but de développer un capteur inertiel. Ici, nous présentons différentes stratégies pour créer un guide sur une puce atomique pour un interférometre Sagnac atomique guidé. Nous avons mis au point trois solutions qui peuvent être realisé avec la même configuration des fils. Ils utilise la technique de modulation de courant avec un nouveau point de vue qui traite simultanément la problème de rugosité des fils et les pertes de Majorana dépendant du spin. L'effect de la propagation multimode des atomes dan le guide est aussi quantifié dans cette thèse. En utilisant un modèle simple, nous avons couvert les cas de la propagation de gaz non interactif ultra froids et thermique. Nous avons identifié les conditions operationelles pour realiser un interferometre à atomes froids avec une grande gamme dynamique, essentielle pour les application en navigation inertielle. Expérimentalement, cette thèse decrit la réalisation et la characterisation de la source atomes froids proche d'un substrat avec un dépôt d'or, ainsi que l'implémentation et la caracterisation des systèmes de détection. / In this thesis we study the propagation of atoms in a magnetic toroidal waveguide, with the aim of developing an inertial sensor. Here, we present different strategies to create the waveguide on an atom chip for a guided Sagnac atom interferometer. We devised three solutions which can be achieved using the same wire configuration. They use the current modulation technique, from a new point of view, which simultaneously tackles the problem of wire corrugation and spin dependent Majorana atom losses. The effect of the multimode propagation of the atoms in the guide is also quantified in this thesis. Using a simple model, we covered the propagation of noninteracting ultracold and thermal gases. We identified the operating conditions to realize a cold atom interferometer with a large dynamic range essential for applications in inertial navigation. Experimentally, the thesis describes the realisation and characterisation of the cold atom source close to a gold coated substrate, as well as the implementation and the characterisation of the atom detection systems.
3

Caractériser le milieu interstellaire : un clé pour comprendre l'Univers

Pety, Jérôme 06 June 2012 (has links) (PDF)
Qu'ont en commun la détection de carbone atomique à un redshift de 4, la cartographie à 1" de résolution de l'émission 12CO(1-0) de la galaxie du tourbillon (M51), l'étude des avant-plans galactiques de Planck, et l'étude de la cinématique du disque et du flot moléculaire de la proto-étoile HH30 ? Au-delà du fait qu'elles sont réalisées dans le domaine (sub-)millimétrique, ces observations sont liées aux processus physiques et chimiques du milieu interstellaire. Caractériser ces processus permet de comprendre les objets les plus divers de l'univers, des plus proches au plus lointains, des plus petits au plus grands. Je décris ici une décennie de travail consacrée à la compréhension du milieu interstellaire. Je commence par présenter deux des approches scientifiques que j'ai prises. La première concerne la caractérisition d'une des transitions les moins bien comprises du gaz dans son chemin vers la formation des étoiles, à savoir la transition HI vers H2.Je montre comment l'interprétation de l'émission 12CO(1-0) pointe tout autant vers le milieu dense et froid que vers le milieu diffus et tiède. Dans un 2ème temps, je décris la nécessité et la mise en place d'une référence observationnelle (la chevelure de la nébuleuse de la Tête de Cheval) pour les modéles photochimiques, eux-mêmes utilisés dans tous les contextes évoqués ci-dessus. La décennie qui vient sera aussi féconde grâce à plusieurs événements. Tout d'abord, la communauté qui étudie le milieu interstellaire se structure rapidement autour de grands projets. A mon niveau, je suis porteur du contrat ANR << Structure and CHemistry of the Inter-Stellar Medium >> (SCHISM) qui réunit observateurs, numériciens et théoréticiens de l'IRAM et de l'Observatoire de Paris. Par ailleurs, l'instrumentation radio fait des progrès spectaculaires qui vont déboucher sur la spectro-imagerie grand champ à haute résolution angulaire et spectrale. L'IRAM a un rôle prépondérant dans cette aventure et j'y contribue au niveau logiciel et algorithmique. Enfin, je participe à la maturation des nouveaux instruments comme les caméras grand-champs pour les antennes uniques et les projets ALMA et NOEMA en interférométrie (sub-)millimétrique. La conjonction de ces facteurs contribuera à percer à jour l'origine des galaxies, des étoiles, des systèmes planétaires et des molécules prébiotiques.

Page generated in 0.0476 seconds