• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 102
  • 37
  • 28
  • 23
  • 22
  • 12
  • 11
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 285
  • 67
  • 61
  • 59
  • 51
  • 48
  • 37
  • 35
  • 32
  • 28
  • 27
  • 27
  • 25
  • 24
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Spectroscopic imaging using quadrature optical coherence tomography

Thanusutiyabhorn, Pimrapat 02 September 2014 (has links)
Optical Coherence Tomography (OCT) is a subsurface imaging technique with many biomedical and industrial applications. In this thesis, we describe our design and implementation of a time domain OCT system. We used this system to obtain OCT images of objects that are important in different applications. We also used an existing quadrature OCT system to obtain both real and imaginary parts of an OCT image. We introduced a new interpretation of OCT images as the 2nd derivative of the scattering potential of an object. To obtain this scattering potential from its 2nd derivative, we implemented a method of definite integration in the spectral-domain. The obtained scattering potential was used to separate the scattering profile from the absorption profile of an object. We applied this new spectroscopic imaging method to quadrature OCT images of different objects.
72

Characterization of Bio-sensing Waveguides in CYTOP Operating with Long Range Surface Plasmon Polaritons (LRSPP’s)

Khan, Asad 14 May 2013 (has links)
This thesis report works on optically characterizing waveguide based biosensors consisting of thin, narrow Au stripes embedded in CYTOP. The devices were examined using an ever evolving and improving interrogation setup, variations of which are described in detail in this document. A number of changes were made to the setup configuration in order to reduce noise levels and increase efficiency and accuracy of acquired measurements. Waveguides of varying configurations (straight waveguides and Mach-Zehnder Interferometers with etched and cladded channels) are described and optically characterized. The characterization results of these devices are presented in this thesis. Bulk index measurements are carried out in order to determine a suitable bio-sensing solution with a refractive index matched to that of CYTOP. Step index measurements clearly distinguishing the introduction of sensing solutions of refractive indices varying from one another, are made available. Preliminary bio-sensing experiments involving detection of change in refractive index of sensing fluid as well as adlayer thickness with the introduction of analytes binding to the waveguide surface that has been functionalized with antibodies, using both straight and cladded waveguides with single mode outputs are studied.
73

Multi-Parameter Sensing Based On In-Line Mach-Zehnder Interferometer

Xu, Yanping 04 September 2013 (has links)
Optical fiber sensors have been intensively studied and successfully employed in various human social activities and daily living, such as industrial production, civil engineering, medicine, transportation, national defense and so on. According to different structures, optical sensors could be divided into various categories. This thesis focuses on studying different kinds of in-line fiber Mach-Zehnder interferometers, which have played an important role among the optical interferometric fiber sensors. The structure composition, fabrication process, physical principle and practical applications of two novel in-line fiber Mach-Zehnder interferometers are proposed and discussed in detail in this work. The tapered bend-insensitive fiber Mach-Zehnder interferometer (BIF-MZI) is firstly fabricated and used as a fiber vibrometer. The unique double-cladding structure of bend-insensitive fiber not only provides higher mechanical strength to the sensor, but also guarantees a more uniform transmission spectrum, since only a few inner-cladding modes are left interfering with the core mode. A high sensitivity and fast response intensity demodulation scheme is employed by monitoring the power fluctuation of the BIF-MZI at the operation wavelength. Both damped and continuous vibrations are detected using the proposed sensor. It is demonstrated that this sensor responses to an extremely wide range of frequencies from 1 Hz up to 500 kHz with high signal-to-noise ratios (SNRs). The discrimination of temperature and axial strain is realized based on the dispersion effects of high-order-mode fiber (HOMF) by forming a single mode fiber-high-order-mode fiber-single mode fiber (SMF-HOMF-SMF) structure based in-line Mach-Zehnder interferometer. Unlike some kinds of in-line MZIs such as tapered and core–offset structures whose cladding modes are excited with different types under changing temperature and strain circumstances, the HOMF is capable of supporting three stable core modes, which guarantees a reliable and repeatable measurements within a large temperature or strain range. A new method based on the fast Fourier transform (FFT) is employed to analyze the mode couplings and their chromatic dispersion and intermodal dispersion properties in HOMF. The strong dispersion effects lead to a multi-peak feature in the spatial frequency spectrum. It is found that peaks that denote the waveform periods at positions that are beyond the critical wavelength possess highly sensitive and distinct phase responses to external disturbances, which provides the possibility to realize the discrimination measurements with high sensitivities and smaller errors by selecting appropriate peaks. The phase demodulation scheme is applied to quantify the temperature and strain changes in terms of phase shifts. Appropriate peak selections according to the practical needs would provide an easy access for applications where more than two parameters are required to be discriminated.
74

Simulation On Interferometric Fiber Optic Gyroscope With Amplified Optical Feedback

Secmen, Basak 01 January 2003 (has links) (PDF)
Position and navigation of vehicle in two and three dimensions have been important as being advanced technology. Therefore, some system has been evaluated to get information of vehicle&rsquo / s position. Main problem in navigation is how to determine position and rotation in three dimensions. If position and rotation is determined, navigation will also be determined with respect to their initial point. There is a technology that vehicle velocity can be discovered, but a technology that rotation can be discovered is needed. Sensor which sense rotation is called gyroscope. If this instrument consists of optical and solid state material, it&rsquo / s defined by Fiber Optic Gyroscope (FOG). There are various studies in order to increase the sensitivity of fiber optic gyroscopes, which is an excellent vehicle for sensing rotation. One of them is interferometric fiber optic gyroscope with amplified optical feedback (FE_FOG). In this system, a feedback loop, which sent the output pulse through the input again, is used. The total output is the summation of each interference and it is in pulse state. The peak position of the output pulse is shifted when rotation occurs. Analyzing this shift, the rotation angle can be determined. In this study, fiber optic gyroscopes, their components and performance characteristics were reviewed. The simulation code was developed by VPIsystems and I used VPItransmissionMakerTM software in this work. The results getting from both rotation and nonrotation cases were analyzed to determine the rotation angle and sensitivity of the gyroscope.
75

Entwicklung einer interferometrischen Messmethode zur Bestimmung des Passfehlers optischer Funktionsflächen in Fertigungsmaschinen /

Dörner, Dirk. January 2006 (has links)
Zugl.: Aachen, Techn. Hochsch., Diss., 2006.
76

Vollautomatische Kalibrierung von Parallelendmaßen mit Hilfe der Phasenverschiebungsinterferometrie

Gruhn, Torsten M. Unknown Date (has links) (PDF)
Techn. Universiẗat, Diss., 2002--Braunschweig.
77

Calibration of MIDI, the mid-infrared interferometer for the VLTI

Schuller, Peter. Unknown Date (has links) (PDF)
University, Diss., 2002--Heidelberg.
78

Multi-channel solutions for optical labelfree detection schemes based on the interferometric and grating coupler principle

Wikerstål, Andreas. Unknown Date (has links) (PDF)
University, Diss., 2001--Freiburg (Breisgau).
79

Interferometric gates for all-optical signal processing

Schubert, Colja. Unknown Date (has links) (PDF)
Techn. University, Diss., 2004--Berlin.
80

Monolithically integrated gain shifted Mach-Zehnder interferometer for all-optical demultiplexing

Tekin, Tolga. Unknown Date (has links) (PDF)
Techn. University, Diss., 2004--Berlin.

Page generated in 0.0844 seconds