• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 6
  • 2
  • Tagged with
  • 23
  • 23
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Grain Boundary Engineering for Improving Intergranular Corrosion resistance of Type 316 Stainless Steel

Qin, Yang January 2017 (has links)
No description available.
12

Corrosão de aços inoxidáveis avançados em meios fisiológicos / Corrosion of advanced stainless steel in physiological solutions

TERADA, MAYSA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:42Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
13

Estudo da corrosão intergranular em ligas de alumínio de fundição influências do teor de cobre e do tratamento de solubilização

Moraes, Ana Carolina de 30 October 2006 (has links)
Made available in DSpace on 2016-12-08T17:19:29Z (GMT). No. of bitstreams: 1 Elementos pre-textuais.pdf: 67551 bytes, checksum: e2f4918c24aa245b8e48c363968398b9 (MD5) Previous issue date: 2006-10-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / It is well known that the element copper, even with an impurity level less than 0,3% modifies substancially the susceptibility to intergranular corrosion in alloys of commercial denomination 356 (nominal composition Al7Si0,3Mg). This paper aims to evaluate the influence of variations in the content of the element copper and the effect of thermal treatment of solubilization on the tendency to intergranular corrosion in samples of alloys of commercial denomination 356 and the Al-Cu system alloys melted in permanent moulds. The alloys were produced using an induction electric oven and involving contents of the element copper as impurity as well as alloy element. Samples were evaluated in fusion and heat treatment conditions utilizing six hours of heating in temperatures of approximately 540 ± 10ºC, and then a fast cooling in water so that the solid solution obtained be maintained in room temperature. The resistance to corrosion was evaluated by the decrease of mass after the samples were subjected to intergranular corrosion tests carried out according to the ASTM G110-92 norm. The results obtained indicate a strong influence of the element copper on the increase of the tendency to corrosion in the investigated alloys, and alterations in this behavior in the comparisons between the fusion and the solubilized conditions. / Trabalhos anteriores mostraram que o elemento cobre, mesmo num teor de impureza (menos de 0,3%Cu), altera substancialmente a suscetibilidade à corrosão intergranular nas ligas de denominação comercial 356 (composição nominal Al7Si0,3Mg). Este trabalho tem por objetivo avaliar a influência de variações nos teores do elemento cobre e o efeito do tratamento térmico de solubilização sobre a tendência à corrosão intergranular em amostras das ligas de denominação comercial 356 e das ligas do sistema Al-Cu fundidas em moldes permanentes. As ligas foram fabricadas usando forno elétrico à indução e envolvendo teores do elemento cobre tanto como impureza quanto como elemento de liga. Foram avaliadas amostras na condição bruta de fusão e solubilizadas utilizando seis horas de aquecimento, após a passagem deste período numa temperatura aproximada de 540 ± 10ºC, um resfriamento rápido em água foi feito para manter na temperatura ambiente, a solução sólida obtida à alta temperatura. A resistência à corrosão foi avaliada através da perda em massa após as amostras terem sido submetidas a ensaios de corrosão intergranular realizados de acordo com a norma ASTM G110-92. Os resultados obtidos indicam uma forte influência do elemento cobre sobre o aumento da tendência à corrosão nas ligas investigadas, e alterações nesse comportamento nas comparações entre as condições brutas de fusão e solubilizadas.
14

Corrosão de aços inoxidáveis avançados em meios fisiológicos / Corrosion of advanced stainless steel in physiological solutions

TERADA, MAYSA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:42Z (GMT). No. of bitstreams: 0 / Este trabalho tem como objetivo principal investigar o comportamento frente à corrosão de aços inoxidáveis avançados em meios fisiológicos. Foram selecionados para o estudo quatro aços inoxidáveis visando avaliar o potencial destes para aplicações em implantes cirúrgicos: um aço superferrítico (DIN W. Nr. 1.4575), a Incoloy MA 956, contendo alumínio e óxido de ítrio, um aço austenítico DIN W. Nr. 1.4970 e um aço superaustenítico obtido por meio da adição de 0,87% de nitrogênio ao aço dúplex DIN W. Nr. 1.4460. Os três primeiros aços contêm baixo teor de níquel e suas películas protetoras são ricas em cromo, enquanto a Incoloy MA 956 é isenta de níquel, e rica em alumínio, o que influencia o seu filme passivo. Os materiais foram analisados usando técnicas de espectroscopia de impedância eletroquímica (EIE), polarização potenciodinâmica, técnica do eletrodo vibrante, microscopia eletroquímica de varredura, microscopia eletrônica de varredura de emissão de campo, microscopia ótica e microscopia eletrônica de varredura. Os meios escolhidos para avaliação da resistência à corrosão foram a solução de Hanks, um meio de cultura e uma solução tamponada com fosfato. Os resultados de EIE foram interpretados usando circuitos elétricos equivalentes que simularam uma camada passiva dúplex em todos os materiais analisados. Todos os materiais analisados apresentaram resistência à corrosão superior à do aço inoxidável AISI 316L, correspondente ao ASTM F-138, que é o mais utilizado na fabricação de implantes metálicos. Também foi destacada a importância do tratamento de solubilização nos aços com alto teor de nitrogênio. O DIN W. Nr. 1.4970 foi considerado citotóxico e sua potencialidade para uso como biomaterial, rejeitada. O DIN W. Nr. 1.4575 e Incoloy MA 956 podem ser usados como biomateriais, mas somente em próteses odontológicas ou de fácil remoção, devido ao seu comportamento ferromagnético. O DIN W. Nr. 1.4460 com 0,87% de nitrogênio foi o que apresentou as condições mais apropriadas para uso como biomaterial, inclusive para próteses ortopédicas. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
15

Resistência à corrosão intergranular do aço inoxidável ferrítico UNS S43000: avaliação por método de reativação eletroquímica, efeito de tratamento isotérmico e mecanismo de sensitização. / Resistance of irregular corrosion of UNS S43000 ferritic stainless steel: evaluate for eletrochemical potentiodynamic test, effect of heat treatment and sensitization mechanism.

Serna-Giraldo, Carlos Augusto 29 June 2006 (has links)
Os aços inoxidáveis ferríticos são susceptíveis à corrosão intergranular após resfriamento rápido a partir de 950°C. A teoria de empobrecimento no teor de cromo nas vizinhanças do carboneto e/ou nitreto, precipitados nos contornos de grão, é o mecanismo mais aceito para descrever este fenômeno. O presente trabalho avalia o efeito dos tratamentos isotérmicos na resistência à corrosão intergranular do aço inoxidável ferrítico UNS S43000, utilizando o método de reativação eletroquímica potenciodinâmica na versão ciclo duplo (DL-EPR). As amostras foram solubilizadas a 1200°C e posteriormente tratadas isotermicamente a temperaturas entre 500°C e 700°C, por tempos de 5 minutos a 16 horas. O ensaio DL-EPR foi realizado em solução 0,5M H2SO4 com velocidade de varredura de 1,67 mV/s. As amostras foram examinadas em microscópio óptico e microscópio eletrônico de varredura após ensaio DL-EPR, Práticas W e X da norma ASTM A763 e ataque metalográfico com reagente Vilella. Foram obtidos diferentes valores de grau de sensitização em função do tempo de tratamento isotérmico. Análises por difração de raios X, sobre resíduos extraídos quimicamente identificaram precipitação de nitretos e de carbonetos de cromo, Cr2N e Cr23C6, respectivamente. As temperaturas de 550°C e 600°C mostraram dois máximos de grau de sensitização em função do tempo, por isso este processo de sensitização foi denominado de dupla sensitização. A partir dos resultados obtidos: grau de sensitização DL-EPR, exame microestrutura e difração de raios X, o presente trabalho propõe o seguinte mecanismo para explicar a dupla sensitização: (Etapa 1) no resfriamento da temperatura de solubilização são precipitados nos contornos de grão fases ricas em cromo; (Etapa 2) os tratamentos isotérmicos geram uma fina precipitação de Cr2N nos contornos de grão sobre os precipitados formados na Etapa 1; (Etapa 3) esses precipitados são posteriormente dissolvidos o que permite (Etapa 4) uma nova precipitação de Cr2N e Cr23C6 nos contornos de grão e (Etapa 5) finalmente temse o processo de crescimento, coalescimento e recuperação final. A recuperação total da resistência à corrosão intergranular foi obtida após tratamentos isotérmicos realizados a 650°C por tempos maiores que 20 minutos e a 700°C a partir de 5 minutos. O trabalho confirma que tanto os fenômenos de precipitação, sensitização e recuperação são controlados 5 pela difusão do cromo na ferrita. Tal confirmação foi possível a partir de análises da solução da segunda lei de Fick e gráficos de Arrhenius, construídos a partir do ensaio DL-EPR e dos exames microestruturais, os quais indicaram uma energia de ativação de precipitação com valor de 255 kJ/mol (219 kJ/mol é o valor da energia de ativação para difusão do cromo na ferrita encontrado em literatura (ARAI; TAKEDA; ARATA, 1987; WOLFE; PAXTON, 1964)). / Ferritic stainless steels are prone to intergranular corrosion following quick cooling from 950°C. The explanation based on chromium impoverishment near the carbides and/or nitrides precipitated in the grain boundaries is the most accepted to describe the observations. This work study the effects of heat treatments on the resistance to intergranular corrosion of the UNS S43000 ferritic stainless steel, using the Double Loop Electrochemical Potentiodynamic Reactivation test (DL-EPR). Specimens have been solution annealed at 1200oC followed by isothermical holding at temperatures between 500°C and 700°C, for times of 5min up to 16h. The DL-EPR test was made in a 0,5M H2SO4 solution using scan rate of 1,67 mV/s. The specimens were observed by optical microscope and scanning electron microscope after DLEPR test, Practices W and X (ASTM A763) and metallographic etch with Vilella reagent. Different degrees of sensitization were obtained for different isothermal holding time. X rays diffraction of extracted precipitates identified chromium nitrides and chromium carbides, Cr2N and Cr23C6. The temperatures of 550°C and 600°C produced two maxima in the curves of degree of sensitization as function of time; the process was named double sensitization. From the results of degree of sensitization DL-EPR, microstructural examination and X rays diffraction, this work proposes the following mechanism to explain double sensitization: (1st stage) during cooling from the solution annealing temperature there is grain boundary precipitation of chromium rich phases; (2nd stage) the isothermal treatments produce a fine grain boundary precipitation of Cr2N on the precipitates formed in the 1st stage; (3rd stage) increasing the time, these precipitates are dissolved, allowing for a (4th stage) new grain boundary precipitation of Cr2N e Cr23C6; finally (5th stage) there is growth, coalescence and recovery. Total recovery of intergranular corrosion resistance was achieved, isothermically at 650°C for times longer than 20min and at 700°C for times longer then 5min. Precipitation, sensitization and recovery are controlled by diffusion of chromium in ferrite. This conclusion was based on analysis of solution of Fick’s second law and Arrhenius plots constructed with DL-EPR data and microstructural observations. The calculus of the experimental energy of activation for precipitation produced a value of 255kJ/mol (energy of activation for chromium 7 diffusion in the ferrite reported by Arai, Takeda and Arata (1987) and Wolfe and Paxton (1964) is 219kJ/mol).
16

Mesure des cinétiques de propagation de la corrosion intergranulaire de l’alliage d’aluminium 2024 : nouvelles approches expérimentales de l’endommagement en fonction des conditions environnementales / Measurement of the intergranular corrosion growth kinetics on a 2024 aluminium alloy : new experimental approaches of damage as function of the environmental conditions

Bonzom, Rémy 08 November 2017 (has links)
Le coût de la maintenance aéronautique pourrait être réduit en proposant des stratégies d’inspection « intelligentes » intégrant des outils prédictifs de l’évolution des défauts, comme la vitesse de propagation de la corrosion intergranulaire.Dans cette thèse, nous avons cherché à quantifier les deux modes d’endommagement associés à la corrosion intergranulaire sur un alliage 2024 : la composante « perforante » (dissolution des pointes de joint de grain) et la composante « émoussante » (dissolution des parois des grains dans les cavités intergranulaires). Pour évaluer la composante « perforante », nous proposons une nouvelle variante de la méthode TFP (méthode OTFP) plus complète car elle ne se limite pas à caractériser le défaut le plus rapide mais permet de suivre l’ensemble des défauts perforants grâce à la nature optique de la détection. Dans cette méthode, le dispositif expérimental laisse libre la face de détection, ce qui permet de prélever l’électrolyte issu des cavités intergranulaires et de procéder à son analyse chimique. Cette donnée, peu connue à ce jour, a été utilisée pour valider des modèles de « transport réactif » qui pourront servir de base à des simulations prédictives intégrant l’effet de la nature de l’environnement. La porosité au sein du matériau induite par la corrosion intergranulaire et amplifiée par la dissolution « émoussante » a été suivie en temps réel par mesure de la conductivité électrique avec une sonde à courants de Foucault. D’abord calibrées en régime potentiostatique, ces méthodes se sont par la suite révélées efficaces pour évaluer l’endommagement associé à la corrosion intergranulaire lors d’une corrosion de type atmosphérique. / Costs of aeronautical maintenance can be reduced by implementation of “smart” inspection strategies integrating predictive data on the evolution of defects such as the propagation rate of intergranular corrosion.In this work, intergranular corrosion damage on 2024 aluminium alloy was characterized by two modes : the “perforating” damage (dissolution of the grain boundary tips) and the “blunting” damage (dissolution of the grain walls in the intergranular cavities). To evaluate the “perforating” damage, a new version of the TFP method (OTFP method) which is more complete, was designed. The OTFP method allows to detect all the intergranular corrosion defects and not only the fastest full penetrating grain boundary thanks to the optical nature of the detection. In this method the detection backside of the thin foil is free, which makes possible the collection of the trapped electrolyte in the intergranular cavities to carry out its chemical analysis. This not well-known data, was used to validate “mass-transport” models which could be implemented in predictive simulations considering the effect of the environmental conditions. The porosity inside the foil induced by the intergranular corrosion and enhanced by the “blunting” dissolution was followed in real-time by measuring the electrical conductivity using an eddy current probe.These methods were first calibrated in potentiostatic tests and then successfully applied to evaluate the intergranular corrosion damage in atmospheric corrosion conditions.
17

Resistência à corrosão intergranular do aço inoxidável ferrítico UNS S43000: avaliação por método de reativação eletroquímica, efeito de tratamento isotérmico e mecanismo de sensitização. / Resistance of irregular corrosion of UNS S43000 ferritic stainless steel: evaluate for eletrochemical potentiodynamic test, effect of heat treatment and sensitization mechanism.

Carlos Augusto Serna-Giraldo 29 June 2006 (has links)
Os aços inoxidáveis ferríticos são susceptíveis à corrosão intergranular após resfriamento rápido a partir de 950°C. A teoria de empobrecimento no teor de cromo nas vizinhanças do carboneto e/ou nitreto, precipitados nos contornos de grão, é o mecanismo mais aceito para descrever este fenômeno. O presente trabalho avalia o efeito dos tratamentos isotérmicos na resistência à corrosão intergranular do aço inoxidável ferrítico UNS S43000, utilizando o método de reativação eletroquímica potenciodinâmica na versão ciclo duplo (DL-EPR). As amostras foram solubilizadas a 1200°C e posteriormente tratadas isotermicamente a temperaturas entre 500°C e 700°C, por tempos de 5 minutos a 16 horas. O ensaio DL-EPR foi realizado em solução 0,5M H2SO4 com velocidade de varredura de 1,67 mV/s. As amostras foram examinadas em microscópio óptico e microscópio eletrônico de varredura após ensaio DL-EPR, Práticas W e X da norma ASTM A763 e ataque metalográfico com reagente Vilella. Foram obtidos diferentes valores de grau de sensitização em função do tempo de tratamento isotérmico. Análises por difração de raios X, sobre resíduos extraídos quimicamente identificaram precipitação de nitretos e de carbonetos de cromo, Cr2N e Cr23C6, respectivamente. As temperaturas de 550°C e 600°C mostraram dois máximos de grau de sensitização em função do tempo, por isso este processo de sensitização foi denominado de dupla sensitização. A partir dos resultados obtidos: grau de sensitização DL-EPR, exame microestrutura e difração de raios X, o presente trabalho propõe o seguinte mecanismo para explicar a dupla sensitização: (Etapa 1) no resfriamento da temperatura de solubilização são precipitados nos contornos de grão fases ricas em cromo; (Etapa 2) os tratamentos isotérmicos geram uma fina precipitação de Cr2N nos contornos de grão sobre os precipitados formados na Etapa 1; (Etapa 3) esses precipitados são posteriormente dissolvidos o que permite (Etapa 4) uma nova precipitação de Cr2N e Cr23C6 nos contornos de grão e (Etapa 5) finalmente temse o processo de crescimento, coalescimento e recuperação final. A recuperação total da resistência à corrosão intergranular foi obtida após tratamentos isotérmicos realizados a 650°C por tempos maiores que 20 minutos e a 700°C a partir de 5 minutos. O trabalho confirma que tanto os fenômenos de precipitação, sensitização e recuperação são controlados 5 pela difusão do cromo na ferrita. Tal confirmação foi possível a partir de análises da solução da segunda lei de Fick e gráficos de Arrhenius, construídos a partir do ensaio DL-EPR e dos exames microestruturais, os quais indicaram uma energia de ativação de precipitação com valor de 255 kJ/mol (219 kJ/mol é o valor da energia de ativação para difusão do cromo na ferrita encontrado em literatura (ARAI; TAKEDA; ARATA, 1987; WOLFE; PAXTON, 1964)). / Ferritic stainless steels are prone to intergranular corrosion following quick cooling from 950°C. The explanation based on chromium impoverishment near the carbides and/or nitrides precipitated in the grain boundaries is the most accepted to describe the observations. This work study the effects of heat treatments on the resistance to intergranular corrosion of the UNS S43000 ferritic stainless steel, using the Double Loop Electrochemical Potentiodynamic Reactivation test (DL-EPR). Specimens have been solution annealed at 1200oC followed by isothermical holding at temperatures between 500°C and 700°C, for times of 5min up to 16h. The DL-EPR test was made in a 0,5M H2SO4 solution using scan rate of 1,67 mV/s. The specimens were observed by optical microscope and scanning electron microscope after DLEPR test, Practices W and X (ASTM A763) and metallographic etch with Vilella reagent. Different degrees of sensitization were obtained for different isothermal holding time. X rays diffraction of extracted precipitates identified chromium nitrides and chromium carbides, Cr2N and Cr23C6. The temperatures of 550°C and 600°C produced two maxima in the curves of degree of sensitization as function of time; the process was named double sensitization. From the results of degree of sensitization DL-EPR, microstructural examination and X rays diffraction, this work proposes the following mechanism to explain double sensitization: (1st stage) during cooling from the solution annealing temperature there is grain boundary precipitation of chromium rich phases; (2nd stage) the isothermal treatments produce a fine grain boundary precipitation of Cr2N on the precipitates formed in the 1st stage; (3rd stage) increasing the time, these precipitates are dissolved, allowing for a (4th stage) new grain boundary precipitation of Cr2N e Cr23C6; finally (5th stage) there is growth, coalescence and recovery. Total recovery of intergranular corrosion resistance was achieved, isothermically at 650°C for times longer than 20min and at 700°C for times longer then 5min. Precipitation, sensitization and recovery are controlled by diffusion of chromium in ferrite. This conclusion was based on analysis of solution of Fick’s second law and Arrhenius plots constructed with DL-EPR data and microstructural observations. The calculus of the experimental energy of activation for precipitation produced a value of 255kJ/mol (energy of activation for chromium 7 diffusion in the ferrite reported by Arai, Takeda and Arata (1987) and Wolfe and Paxton (1964) is 219kJ/mol).
18

Effects of stress on intergranular corrosion and intergranular stress corrosion cracking in AA2024-T3

Liu, Xiaodong 02 December 2005 (has links)
No description available.
19

Estudo da corrosão em junta tubo-espelho soldada por SATG entre as ligas AISI 316L e AISI 444 / Study of corrosion process on tube-to-tubesheet welded joints performed with TIG process and using AISI 316L and AISI 444 alloys

Guilherme, Luis Henrique 21 November 2011 (has links)
Nos últimos anos houve, no Brasil, um significativo investimento em usinas de álcool para suprir a demanda. Todavia, surgiram problemas de natureza econômica e ambiental, já que a tecnologia atualmente utilizada nas destilarias de álcool produz em média 13 litros de vinhaça para cada litro de álcool. Na busca de uma solução para reduzir o volume deste resíduo, desenvolveu-se um equipamento para concentração de vinhaça, denominado Ecovin, pela empresa Citrotec localizada em Araraquara-SP. Para cada Ecovin são utilizados cerca de 4000 tubos com costura nos trocadores de calor, e para reduzir seu custo de fabricação, avaliou-se como opção o uso de tubos da liga AISI 444. Inserido neste contexto, o presente trabalho procurou caracterizar os mecanismos de corrosão e mostrar de forma comparativa o desempenho dos tubos nas juntas tubo-espelho. Estudo-se, portanto, dois tipos de junta, a do projeto atual, composta por chapa e tubo da liga AISI 316L; e a nova proposta, composta por chapa da liga AISI 316L e tubo da liga AISI 444. Para tanto, iniciou-se com a avaliação da soldabilidade das ligas estudadas, através da caracterização microestrutural, qualificação do procedimento de soldagem da junta tubo-espelho e de ensaios de sensitização nas soldas. Em seguida, ensaios de perda de massa por imersão foram realizados nas soluções de 0,5 M \'H IND.2\'SO IND.4\' e 0,5 M \'H\'CL\', nas temperaturas de 30°C, 50°C, 70°C e 90°C, de acordo com o intervalo de temperatura de operação do Ecovin. Nas mesmas soluções, e na temperatura ambiente, foram realizados ensaios eletroquímicos de polarização potenciodinâmica em amostras que reproduziram o ciclo térmico de soldagem das juntas tubo-espelho estudadas, nas regiões do metal de base, zona afetada pelo calor (ZAC) e no metal de solda. Na junta tubo-espelho a corrosão ocorreu preferencialmente na ZAC formada entre a interface tubo-metal de solda, e no cordão de solda à margem do tubo, com a atuação de mecanismos de corrosão generalizada e localizada. Na junta tubo-espelho dissimilar observou-se que o processo corrosivo foi predominante na superfície do tubo AISI 444, típico do mecanismo de corrosão galvânica, onde o tubo AISI 444 caracterizou-se como a região anódica. O desempenho da liga AISI 316L, assim como a junta soldada composta somente por essa liga, apresentou um melhor desempenho em corrosão, porém, na solução contendo cloreto, a variação da temperatura exerceu uma influência proporcional para ambos os casos avaliados nesse estudo. Destaca-se ainda que a liga AISI 316L sofreu corrosão por pite na ZAC e no metal de solda, em ambas as soluções, com maior severidade do que a liga AISI 444. Os resultados obtidos indicam que para a aplicação requerida, o tubo AISI 444 pode ser utilizado na temperatura de 50°C com satisfatório desempenho e similar à junta composta somente por AISI 316L. / Recently in Brazil there has been constant investments in ethanol plants, to supply the internal and external market, resulting at a high increase of the volume of this product. However, economical and environmental problems arose because of this new demand, whereas the current technologies produce thirteen liters of vinasse for each liter of alcohol. Each ECOVIN uses nearly 4000 welded tubes in the heat exchangers, and there is an option to use welded AISI 444 alloy tubes in order to reduce the manufacture costs of the ECOVIN. In this context, this work determines the corrosion mechanisms and analyzes the performance of welded tubes and the tube-to-tubesheet welded joints. The following types of tube-to-tubesheet were evaluated: current welded joints of this project, with all components manufactured with AISI 316L alloy; and the welded joint suggested for the project, using the welded tubes of AISI 444 alloy and the plate of AISI 316L alloy. For this purpose, the first step was to evaluate the weldability of the studied alloys, through microstructural characterization, welding procedure qualification and the intergranular corrosion test. After that, mass loss tests were conducted in 0,5 M \'H IND.2\'SO IND.4\' and 0,5 M \'H\'CL\' solutions, at 30°C, 50°C, 70°C and 90°C, according to the temperature range of the equipment operating. Electrochemical polarization tests were made in the same solution concentration used in the mass loss tests, but only in room temperature. These tests were made in samples that were welded with the same thermal cycle of the tube-to-tubesheet welded joints, and the evaluations were made on the base metal, heat affected zones and weld metal. The uniform and localized corrosion process occurred preferentially in the interface formed between tube and weld metal, and on weld metal near the tubes. In the tube-to-tubesheet dissimilar welded joints, it was observed that the corrosion process was predominant on the surface of AISI 444 alloy, probably because of the galvanic corrosion process, where the AISI 444 was an anodic region. The best performance on corrosion process was observed in AISI 316L, both the base metal and the similar welded joints. However, for the tests in chloride environment, in this process, the temperature caused a proportional influence in the corrosion rate of AISI 316L and AISI 444. In the AISI 316L alloy it was observed nucleation of pitting in HAZ and in weld metal, in both solutions, and more aggressive than observed in the AISI 444 alloy. The results showed that the AISI 444 alloy can be applied for the initial ranging temperatures of the equipments operation, with satisfactory performance.
20

Structural Characterisation, Residual Stress Determination and Degree of Sensitisation of Duplex Stainless Steel Welds

Gideon Abdullah, Mohammed Abdul Fatah, barrygideon@hotmail.com January 2009 (has links)
Welding of duplex stainless steel pipeline material for the oil and gas industry is now common practice. To date, research has been conducted primarily on the parent material and heat affected zones in terms of its susceptibility to various forms of corrosion. However, there has been little research conducted on the degree of sensitisation of the various successive weld layers, namely the root, fill and cap layers. The focus of this research study was to: (i) provide an in-depth microstructural analysis of the various weld passes, (ii) study the mechanical properties of the weld regions; (iii) determine degree of sensitisation of the various weld passes; and (iv) investigate the residual stress levels within the various regions/ phases of the welds. Four test conditions were prepared using manual Gas Tungsten Arc Welding with 'V' and 'U' bevel configuration. Structural analysis consisted of (i) optical microscopy, scanning electron microscopy and magnetic force microscopy; (ii) ferrite determination using Magna-Gauge, Fischer Ferrite-scope and Point Count method. Mechanical testing consisted of Vickers hardness measurements, Charpy impact studies and transverse tensile testing. The degree of sensitisation was determined by three test methods: a modified ASTM A262, ASTM A923 and a modified Double Loop Electrochemical Potentiodynamic Reactivation (DL-EPR) test. Residual stress levels were determined using two neutron diffraction techniques: a reactor source and a time of flight spallation source. Microstructure observed by optical microscopy and magnetic force microscopy shows the formation of both fine and coarse structures within the weld metal. There was no evidence of secondary austenite, being present in any of the weld metal conditions examined. In addition, no detrimental intermetallic phases or carbides were present. The DL-EPR test results revealed that the fill layer regions for all four conditions and the base material showed the highest values for Ir/Ia and Qr/Qa. All four test conditions passed the ASTM A262 and A923 qualitative type tests, even under restricted and modified conditions. Residual stress measurements by neutron diffraction conducted at Lucas Heights Hi-Flux Reactor revealed that the ferrite phase stress was tensile in the heat affected zones and weld, and appeared to be balanced by a local compressive austenite phase stresses in the normal and transverse directions. Residual stress measurements by neutron diffraction conducted at Los Alamos Nuclear Science Centre revealed that in the hoop direction, ferrite (211) and austenite (311) exhibit tensile strains in the weld. In the axial and radial direction, the strains for both phases were more compressive. Correlations between the degree of sensitization and microstructural changes / ferrite content were observed. Higher degrees of sensitization (Ir/Ia and Qr/Qa) were associated with reduced ferrite (increased austenite) content. Correlations between the stresses generated, the evolved microstructures and degree of sensitization were evident. Stresses within the cap region were generally shown to be of a tensile nature in the transverse and longitudinal direction. In summary, the study has shown that correlations exist between the weld microstructure, susceptibility to sensitisation and levels / distribution of internal stresses within the weld regions.

Page generated in 0.1194 seconds