• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos químicos de reações (ETA, 2ETA) em sistemas iodato e periodato

Mendonça, José Miguel Aires de, Instituto de Engenharia Nuclear 12 1900 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-12-06T18:00:19Z No. of bitstreams: 1 JOSÉ MIGUEL AIRES DE MENDONÇA M.pdf: 1971515 bytes, checksum: 81e7d9cad195ad4562b54f6f364ba3e8 (MD5) / Made available in DSpace on 2017-12-06T18:00:19Z (GMT). No. of bitstreams: 1 JOSÉ MIGUEL AIRES DE MENDONÇA M.pdf: 1971515 bytes, checksum: 81e7d9cad195ad4562b54f6f364ba3e8 (MD5) Previous issue date: 1975-12 / Os efeitos químicos de reações (n, 2n) em iodatos e periodatos de sódio cristalinos foram investigados medindo-se os rendimentos iniciais e os rendimentos em "annealling" isotérmico pós-irradiação (90°C) e das frações separadas l-, IO3- e 10-4. NalO3, Nal03.H20 e NaIO4, Na3H2IO6, Na4IO9.3 H20 " contendo 127I ou 129 I , ou ambos, foram irradiados com nêutrons de 14MeV. Os resultados obtidos mostram diferentes efeitos em cada sistema estudado e que os isótopos 126I e 128I mantêm o mesmo comportamento nos compostos irradiados contendo isoladamente 127I ou 123 I , assim como em compostos contendo conjuntamente 127I e l29 l. Não observou-se efeito isotópico nem diferenças qualitativas no "annealing" isotérmico a 90?C. No "annealing" as frações incrementadas nos três periodatos estudados foram 10-3 e 10-4. Estes resultados são diferentes dos encontrados por V.V.Bell ido e E. Batalha em reações (n,y) para os mesmos compostos.
2

Desenvolvimento de procedimento analítico para determinação de iodato em sal de mesa utilizando sistema com multicomutação e detecção espectrofotométrica / Development of analytical procedure for determination of iodate in table salt using a multicommuted system and spectrophotometric detection

Silva, Amanda Ribeiro Martins da 18 April 2016 (has links)
A iodação do sal de mesa é considerada o caminho mais eficiente para controlar os Distúrbios por Deficiência de Iodo. Em países tropicais, o elemento pode ser adicionado na forma de KIO3. Para garantir que os níveis ideais do ânion estejam disponíveis ao consumidor, o controle de qualidade do sal consiste numa estratégia fundamental. Sistemas em fluxo com multicomutação representam uma alternativa versátil para o desenvolvimento de procedimentos simples, rápidos e limpos, minimizando o consumo de reagentes e a geração de resíduos. Nesse contexto, um procedimento analítico utilizando sistema com multicomutação e detecção espectrofotométrica foi desenvolvido para a determinação de iodato em sal de mesa. A reação empregada foi baseada na formação de um composto roxo (540 nm) entre iodato (IO3-) e p-aminofenol (PAP) em meio ácido. O tempo de residência da zona de amostra no percurso analítico foi explorado a fim de favorecer a reação lenta e a frequência de amostragem para a melhoria do desempenho analítico. Foram selecionados 2 pulsos para inserção de amostra, 3 pulsos para reagente (PAP 0,25% (m/v) em HCl 0,025 mol L-1), 7 ciclos de amostragem, 200 pulsos de carregador (água), bolha de ar de 1 s (40 µL), reator de 70 cm (3 mm d.i.) e parada de fluxo de 480 s. Resposta linear foi observada entre 2,28x10-5 e 3,65x10-4 mol L-1, descrita pela equação A = 0,2443 + 2030 C, r = 0,997. Limite de detecção (99,7% de confiança), coeficiente de variação (n = 20) e frequência de amostragem foram estimados em 8,2x10-6 mol L-1, 0,42% e 70 determinações por hora, respectivamente. Houve consumo de 1,05 mg de PAP e geração de 0,70 mL de resíduos por determinação. As principais espécies concomitantes presentes na amostra não interferiram na determinação de iodato em concentrações até 8 vezes maiores que as usualmente encontradas. Estudos de adição e recuperação de iodato foram realizados pelo procedimento proposto, obtendo porcentagens de recuperação entre 88 e 104%. O procedimento analítico desenvolvido apresenta sensibilidade adequada para a determinação de iodato em amostra de sal de mesa e elevada frequência de amostragem quando comparado com procedimentos descritos na literatura / Table salt iodization is considered the most efficient way to control iodine-deficiency disorders. In tropical countries, the element can be added as KIO3. To ensure that ideal amounts of this anion are available to consumers, the quality control of iodized salt is fundamental strategy. Multicommuted flow systems represent a versatile alternative to the development of simple, fast and clean procedure, minimizing reagent consumption and waste generation. In this context, an analytical procedure using a multicommuted system and spectrophotometric detection was developed for determination of iodate in table salts. The chemical reaction was based on the formation of purple compound (540 nm) between iodate (IO3-) and p-aminophenol (PAP) in acidic medium. The sample residence time in the analytical path was explored in order to further the slow chemical reaction and the sampling rate for the improvement of the system analytical performance. Optimized conditions were 2 sample pulses, 3 reagent pulses (PAP 0.25% (w/v) in HCl 0.025 mol L-1) in 7 sampling cycles, 200 carrier pulses (water), 1 s air bubble (40 µL), a 70-cm long reactor coil (3 mm i.d.) and the flow was stopped for 480 s. A linear response was observed between 2.28x10-5 and 3.65x10-4 mol L-1 iodate, described by the equation A = 0.2443 + 2030 C, r = 0.997. Detection limit (99.7% confidence level), coefficient of variation (n = 20) and sampling rate were 8.2x10-6 mol L-1, 0.42% and 70 determination per hour, respectively. Only 1.05 mg of PAP was consumed and 0.70 mL of waste was generated per determination. Usual concomitant species found in table salts did not cause significant interference in concentrations up to 8-fold higher than those expected. Recoveries between 88 and 104% were obtained for iodate spiked samples. The developed analytical procedure presented adequate sensitivity for the determination of iodate in table salts sample and higher sampling rate compared to literature procedures
3

Eletrodos modificados por óxido de tungstênio: Métodos de preparação e aplicações analíticas / Modified Electrodes with Tungsten Oxide: Preparation Methods and Analytic Applications

Rocha, José Roberto Caetano da 23 January 2006 (has links)
Neste trabalho são apresentados resultados da eletrodeposição de MoOx e de WOx em eletrodos de carbono vítreo e em eletrodos de ouro. A estabilidade de filmes de WOx foi investigada em diferentes valores de pH utilizando voltametria cíclica e microbalança eletroquímica de cristal de quartzo e observou-se que estes filmes são estáveis em soluções com valores de pH inferiores a 3. O processo eletrocatalítico envolvendo a redução de IO3- em superfícies recobertas com WOx foi comparado com aquele observado em eletrodo modificado com MoOx, observando-se as vantagens deste processo em superfícies modificadas com WOx. Discutiram-se ainda os resultados obtidos do processo da oxidação de óxido nítrico na superfície eletródica polida e modificada com WOx. Também são apresentados resultados de estudos comparativos sobre a redução do IO3-, BrO3- e ClO3- na superfície modificada, concluindo-se que no caso do IO3- obtêm-se maiores valores de corrente devido à maior polarizabilidade do átomo de iodo em relação aos outros dois halogênios. Estudos envolvendo a permeabilidade de íons IO3- e Fe(CN)63- em filmes de WOx foram realizados por voltametria com eletrodos rotativos percebendo-se que filmes mais espessos apresentam pouca permeabilidade. Eletrodos recobertos por filmes de WOx foram utilizados como sensores amperométricos para iodato. Para tanto, desenvolveu-se método em fluxo para IO3- em uma faixa de concentração de 5 a 5000 mmol/L, com limite de detecção estimado em 210 nmol/L. A repetibilidade do método para 41 injeções de solução 80 mmol/L de IO3- foi de 98,3 %. Também foram realizados ensaios para determinar o analito em amostras de sal de cozinha e os dados obtidos foram concordantes com os resultados oriundos do uso de método oficial. / Thin films of non-stoichiometric tungsten oxides have been deposited onto glassy carbon surfaces by electrodeposition from acidic W (VI) solutions. At these modified surfaces, rotating disc electrode voltammetric experiments indicated that iodate is electrocatalytically reduced in a mass-transport controlled process. The influence of the film thickness on the response to iodate was investigated and the results suggested a reaction occurring at the film/solution interface. The modified electrode was employed successfully as an amperometric sensor for iodate in a flow injection apparatus. The linear response of the developed method is extended from a 5 mmol L-1 to 5 mmol L-1 iodate with a limit of detection (signal-to-noise = 3) of 210 nmol L-1. The repeatability of the method for 41 injections of an 80 mmol L-1 iodate solution was 98,3 % and the throughput was determined as 123 injections h-1. Interference from other oxidant anions such as nitrate and nitrite was not noticeable, whereas bromate and chlorate interfere at slight levels. The method was used in the determination of the iodate content in commercial salt samples.
4

Desenvolvimento de procedimento analítico para determinação de iodato em sal de mesa utilizando sistema com multicomutação e detecção espectrofotométrica / Development of analytical procedure for determination of iodate in table salt using a multicommuted system and spectrophotometric detection

Amanda Ribeiro Martins da Silva 18 April 2016 (has links)
A iodação do sal de mesa é considerada o caminho mais eficiente para controlar os Distúrbios por Deficiência de Iodo. Em países tropicais, o elemento pode ser adicionado na forma de KIO3. Para garantir que os níveis ideais do ânion estejam disponíveis ao consumidor, o controle de qualidade do sal consiste numa estratégia fundamental. Sistemas em fluxo com multicomutação representam uma alternativa versátil para o desenvolvimento de procedimentos simples, rápidos e limpos, minimizando o consumo de reagentes e a geração de resíduos. Nesse contexto, um procedimento analítico utilizando sistema com multicomutação e detecção espectrofotométrica foi desenvolvido para a determinação de iodato em sal de mesa. A reação empregada foi baseada na formação de um composto roxo (540 nm) entre iodato (IO3-) e p-aminofenol (PAP) em meio ácido. O tempo de residência da zona de amostra no percurso analítico foi explorado a fim de favorecer a reação lenta e a frequência de amostragem para a melhoria do desempenho analítico. Foram selecionados 2 pulsos para inserção de amostra, 3 pulsos para reagente (PAP 0,25% (m/v) em HCl 0,025 mol L-1), 7 ciclos de amostragem, 200 pulsos de carregador (água), bolha de ar de 1 s (40 µL), reator de 70 cm (3 mm d.i.) e parada de fluxo de 480 s. Resposta linear foi observada entre 2,28x10-5 e 3,65x10-4 mol L-1, descrita pela equação A = 0,2443 + 2030 C, r = 0,997. Limite de detecção (99,7% de confiança), coeficiente de variação (n = 20) e frequência de amostragem foram estimados em 8,2x10-6 mol L-1, 0,42% e 70 determinações por hora, respectivamente. Houve consumo de 1,05 mg de PAP e geração de 0,70 mL de resíduos por determinação. As principais espécies concomitantes presentes na amostra não interferiram na determinação de iodato em concentrações até 8 vezes maiores que as usualmente encontradas. Estudos de adição e recuperação de iodato foram realizados pelo procedimento proposto, obtendo porcentagens de recuperação entre 88 e 104%. O procedimento analítico desenvolvido apresenta sensibilidade adequada para a determinação de iodato em amostra de sal de mesa e elevada frequência de amostragem quando comparado com procedimentos descritos na literatura / Table salt iodization is considered the most efficient way to control iodine-deficiency disorders. In tropical countries, the element can be added as KIO3. To ensure that ideal amounts of this anion are available to consumers, the quality control of iodized salt is fundamental strategy. Multicommuted flow systems represent a versatile alternative to the development of simple, fast and clean procedure, minimizing reagent consumption and waste generation. In this context, an analytical procedure using a multicommuted system and spectrophotometric detection was developed for determination of iodate in table salts. The chemical reaction was based on the formation of purple compound (540 nm) between iodate (IO3-) and p-aminophenol (PAP) in acidic medium. The sample residence time in the analytical path was explored in order to further the slow chemical reaction and the sampling rate for the improvement of the system analytical performance. Optimized conditions were 2 sample pulses, 3 reagent pulses (PAP 0.25% (w/v) in HCl 0.025 mol L-1) in 7 sampling cycles, 200 carrier pulses (water), 1 s air bubble (40 µL), a 70-cm long reactor coil (3 mm i.d.) and the flow was stopped for 480 s. A linear response was observed between 2.28x10-5 and 3.65x10-4 mol L-1 iodate, described by the equation A = 0.2443 + 2030 C, r = 0.997. Detection limit (99.7% confidence level), coefficient of variation (n = 20) and sampling rate were 8.2x10-6 mol L-1, 0.42% and 70 determination per hour, respectively. Only 1.05 mg of PAP was consumed and 0.70 mL of waste was generated per determination. Usual concomitant species found in table salts did not cause significant interference in concentrations up to 8-fold higher than those expected. Recoveries between 88 and 104% were obtained for iodate spiked samples. The developed analytical procedure presented adequate sensitivity for the determination of iodate in table salts sample and higher sampling rate compared to literature procedures
5

Eletrodos modificados por óxido de tungstênio: Métodos de preparação e aplicações analíticas / Modified Electrodes with Tungsten Oxide: Preparation Methods and Analytic Applications

José Roberto Caetano da Rocha 23 January 2006 (has links)
Neste trabalho são apresentados resultados da eletrodeposição de MoOx e de WOx em eletrodos de carbono vítreo e em eletrodos de ouro. A estabilidade de filmes de WOx foi investigada em diferentes valores de pH utilizando voltametria cíclica e microbalança eletroquímica de cristal de quartzo e observou-se que estes filmes são estáveis em soluções com valores de pH inferiores a 3. O processo eletrocatalítico envolvendo a redução de IO3- em superfícies recobertas com WOx foi comparado com aquele observado em eletrodo modificado com MoOx, observando-se as vantagens deste processo em superfícies modificadas com WOx. Discutiram-se ainda os resultados obtidos do processo da oxidação de óxido nítrico na superfície eletródica polida e modificada com WOx. Também são apresentados resultados de estudos comparativos sobre a redução do IO3-, BrO3- e ClO3- na superfície modificada, concluindo-se que no caso do IO3- obtêm-se maiores valores de corrente devido à maior polarizabilidade do átomo de iodo em relação aos outros dois halogênios. Estudos envolvendo a permeabilidade de íons IO3- e Fe(CN)63- em filmes de WOx foram realizados por voltametria com eletrodos rotativos percebendo-se que filmes mais espessos apresentam pouca permeabilidade. Eletrodos recobertos por filmes de WOx foram utilizados como sensores amperométricos para iodato. Para tanto, desenvolveu-se método em fluxo para IO3- em uma faixa de concentração de 5 a 5000 mmol/L, com limite de detecção estimado em 210 nmol/L. A repetibilidade do método para 41 injeções de solução 80 mmol/L de IO3- foi de 98,3 %. Também foram realizados ensaios para determinar o analito em amostras de sal de cozinha e os dados obtidos foram concordantes com os resultados oriundos do uso de método oficial. / Thin films of non-stoichiometric tungsten oxides have been deposited onto glassy carbon surfaces by electrodeposition from acidic W (VI) solutions. At these modified surfaces, rotating disc electrode voltammetric experiments indicated that iodate is electrocatalytically reduced in a mass-transport controlled process. The influence of the film thickness on the response to iodate was investigated and the results suggested a reaction occurring at the film/solution interface. The modified electrode was employed successfully as an amperometric sensor for iodate in a flow injection apparatus. The linear response of the developed method is extended from a 5 mmol L-1 to 5 mmol L-1 iodate with a limit of detection (signal-to-noise = 3) of 210 nmol L-1. The repeatability of the method for 41 injections of an 80 mmol L-1 iodate solution was 98,3 % and the throughput was determined as 123 injections h-1. Interference from other oxidant anions such as nitrate and nitrite was not noticeable, whereas bromate and chlorate interfere at slight levels. The method was used in the determination of the iodate content in commercial salt samples.

Page generated in 0.0183 seconds