• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de procedimento analítico para determinação de iodato em sal de mesa utilizando sistema com multicomutação e detecção espectrofotométrica / Development of analytical procedure for determination of iodate in table salt using a multicommuted system and spectrophotometric detection

Silva, Amanda Ribeiro Martins da 18 April 2016 (has links)
A iodação do sal de mesa é considerada o caminho mais eficiente para controlar os Distúrbios por Deficiência de Iodo. Em países tropicais, o elemento pode ser adicionado na forma de KIO3. Para garantir que os níveis ideais do ânion estejam disponíveis ao consumidor, o controle de qualidade do sal consiste numa estratégia fundamental. Sistemas em fluxo com multicomutação representam uma alternativa versátil para o desenvolvimento de procedimentos simples, rápidos e limpos, minimizando o consumo de reagentes e a geração de resíduos. Nesse contexto, um procedimento analítico utilizando sistema com multicomutação e detecção espectrofotométrica foi desenvolvido para a determinação de iodato em sal de mesa. A reação empregada foi baseada na formação de um composto roxo (540 nm) entre iodato (IO3-) e p-aminofenol (PAP) em meio ácido. O tempo de residência da zona de amostra no percurso analítico foi explorado a fim de favorecer a reação lenta e a frequência de amostragem para a melhoria do desempenho analítico. Foram selecionados 2 pulsos para inserção de amostra, 3 pulsos para reagente (PAP 0,25% (m/v) em HCl 0,025 mol L-1), 7 ciclos de amostragem, 200 pulsos de carregador (água), bolha de ar de 1 s (40 µL), reator de 70 cm (3 mm d.i.) e parada de fluxo de 480 s. Resposta linear foi observada entre 2,28x10-5 e 3,65x10-4 mol L-1, descrita pela equação A = 0,2443 + 2030 C, r = 0,997. Limite de detecção (99,7% de confiança), coeficiente de variação (n = 20) e frequência de amostragem foram estimados em 8,2x10-6 mol L-1, 0,42% e 70 determinações por hora, respectivamente. Houve consumo de 1,05 mg de PAP e geração de 0,70 mL de resíduos por determinação. As principais espécies concomitantes presentes na amostra não interferiram na determinação de iodato em concentrações até 8 vezes maiores que as usualmente encontradas. Estudos de adição e recuperação de iodato foram realizados pelo procedimento proposto, obtendo porcentagens de recuperação entre 88 e 104%. O procedimento analítico desenvolvido apresenta sensibilidade adequada para a determinação de iodato em amostra de sal de mesa e elevada frequência de amostragem quando comparado com procedimentos descritos na literatura / Table salt iodization is considered the most efficient way to control iodine-deficiency disorders. In tropical countries, the element can be added as KIO3. To ensure that ideal amounts of this anion are available to consumers, the quality control of iodized salt is fundamental strategy. Multicommuted flow systems represent a versatile alternative to the development of simple, fast and clean procedure, minimizing reagent consumption and waste generation. In this context, an analytical procedure using a multicommuted system and spectrophotometric detection was developed for determination of iodate in table salts. The chemical reaction was based on the formation of purple compound (540 nm) between iodate (IO3-) and p-aminophenol (PAP) in acidic medium. The sample residence time in the analytical path was explored in order to further the slow chemical reaction and the sampling rate for the improvement of the system analytical performance. Optimized conditions were 2 sample pulses, 3 reagent pulses (PAP 0.25% (w/v) in HCl 0.025 mol L-1) in 7 sampling cycles, 200 carrier pulses (water), 1 s air bubble (40 µL), a 70-cm long reactor coil (3 mm i.d.) and the flow was stopped for 480 s. A linear response was observed between 2.28x10-5 and 3.65x10-4 mol L-1 iodate, described by the equation A = 0.2443 + 2030 C, r = 0.997. Detection limit (99.7% confidence level), coefficient of variation (n = 20) and sampling rate were 8.2x10-6 mol L-1, 0.42% and 70 determination per hour, respectively. Only 1.05 mg of PAP was consumed and 0.70 mL of waste was generated per determination. Usual concomitant species found in table salts did not cause significant interference in concentrations up to 8-fold higher than those expected. Recoveries between 88 and 104% were obtained for iodate spiked samples. The developed analytical procedure presented adequate sensitivity for the determination of iodate in table salts sample and higher sampling rate compared to literature procedures
2

Desenvolvimento de procedimento analítico para determinação de iodato em sal de mesa utilizando sistema com multicomutação e detecção espectrofotométrica / Development of analytical procedure for determination of iodate in table salt using a multicommuted system and spectrophotometric detection

Amanda Ribeiro Martins da Silva 18 April 2016 (has links)
A iodação do sal de mesa é considerada o caminho mais eficiente para controlar os Distúrbios por Deficiência de Iodo. Em países tropicais, o elemento pode ser adicionado na forma de KIO3. Para garantir que os níveis ideais do ânion estejam disponíveis ao consumidor, o controle de qualidade do sal consiste numa estratégia fundamental. Sistemas em fluxo com multicomutação representam uma alternativa versátil para o desenvolvimento de procedimentos simples, rápidos e limpos, minimizando o consumo de reagentes e a geração de resíduos. Nesse contexto, um procedimento analítico utilizando sistema com multicomutação e detecção espectrofotométrica foi desenvolvido para a determinação de iodato em sal de mesa. A reação empregada foi baseada na formação de um composto roxo (540 nm) entre iodato (IO3-) e p-aminofenol (PAP) em meio ácido. O tempo de residência da zona de amostra no percurso analítico foi explorado a fim de favorecer a reação lenta e a frequência de amostragem para a melhoria do desempenho analítico. Foram selecionados 2 pulsos para inserção de amostra, 3 pulsos para reagente (PAP 0,25% (m/v) em HCl 0,025 mol L-1), 7 ciclos de amostragem, 200 pulsos de carregador (água), bolha de ar de 1 s (40 µL), reator de 70 cm (3 mm d.i.) e parada de fluxo de 480 s. Resposta linear foi observada entre 2,28x10-5 e 3,65x10-4 mol L-1, descrita pela equação A = 0,2443 + 2030 C, r = 0,997. Limite de detecção (99,7% de confiança), coeficiente de variação (n = 20) e frequência de amostragem foram estimados em 8,2x10-6 mol L-1, 0,42% e 70 determinações por hora, respectivamente. Houve consumo de 1,05 mg de PAP e geração de 0,70 mL de resíduos por determinação. As principais espécies concomitantes presentes na amostra não interferiram na determinação de iodato em concentrações até 8 vezes maiores que as usualmente encontradas. Estudos de adição e recuperação de iodato foram realizados pelo procedimento proposto, obtendo porcentagens de recuperação entre 88 e 104%. O procedimento analítico desenvolvido apresenta sensibilidade adequada para a determinação de iodato em amostra de sal de mesa e elevada frequência de amostragem quando comparado com procedimentos descritos na literatura / Table salt iodization is considered the most efficient way to control iodine-deficiency disorders. In tropical countries, the element can be added as KIO3. To ensure that ideal amounts of this anion are available to consumers, the quality control of iodized salt is fundamental strategy. Multicommuted flow systems represent a versatile alternative to the development of simple, fast and clean procedure, minimizing reagent consumption and waste generation. In this context, an analytical procedure using a multicommuted system and spectrophotometric detection was developed for determination of iodate in table salts. The chemical reaction was based on the formation of purple compound (540 nm) between iodate (IO3-) and p-aminophenol (PAP) in acidic medium. The sample residence time in the analytical path was explored in order to further the slow chemical reaction and the sampling rate for the improvement of the system analytical performance. Optimized conditions were 2 sample pulses, 3 reagent pulses (PAP 0.25% (w/v) in HCl 0.025 mol L-1) in 7 sampling cycles, 200 carrier pulses (water), 1 s air bubble (40 µL), a 70-cm long reactor coil (3 mm i.d.) and the flow was stopped for 480 s. A linear response was observed between 2.28x10-5 and 3.65x10-4 mol L-1 iodate, described by the equation A = 0.2443 + 2030 C, r = 0.997. Detection limit (99.7% confidence level), coefficient of variation (n = 20) and sampling rate were 8.2x10-6 mol L-1, 0.42% and 70 determination per hour, respectively. Only 1.05 mg of PAP was consumed and 0.70 mL of waste was generated per determination. Usual concomitant species found in table salts did not cause significant interference in concentrations up to 8-fold higher than those expected. Recoveries between 88 and 104% were obtained for iodate spiked samples. The developed analytical procedure presented adequate sensitivity for the determination of iodate in table salts sample and higher sampling rate compared to literature procedures
3

Desenvolvimento de procedimentos analíticos limpos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de cobalto e cádmio em águas / Development of clean analytical procedures employing multicommutation flow analysis systems for photometric determination of cobalt and cadmium in waters

Gondim, Ticiane Silva 12 December 2016 (has links)
Esse trabalho tem como objetivo o desenvolvimento de procedimentos analíticos automáticos, empregando o processo de multicomutação em fluxo para determinação espectrofotométrica de cobalto e cádmio em amostras de águas. O trabalho envolveu o desenvolvimento dos módulos de análises para implementar os procedimentos analíticos baseados no processo de multicomutação, o sistema de detecção fotométrica empregando LED como fonte de radiação eletromagnética, o software para controle do módulo de análise e para efetuar aquisição de dados. O módulo de análise para determinação de cobalto foi desenvolvido, utilizando mini-bombas solenóide para o bombeamento das soluções. O procedimento analítico foi baseado na catálise do cobalto na reação de oxidação do Tiron pelo peróxido de hidrogênio e com o sistema de detecção espectrofotométrica com LED com emissão em 425 nm. Após os ajustes necessários do módulo de análise o sistema apresentou bom desempenho analítico. Para a determinação de cobalto em águas foram obtidas as seguintes características analíticas: desvio padrão relativo de 0,04 % (n = 13) para uma amostra com 0,5 µgL-1 de Co, faixa de resposta linear entre 0,13 a 1,5 µgL-1 de Co (R = 0,998, n = 3), limite de detecção de 0,06 µgL-1, frequência analítica de 42 determinações por hora e geração de 1,5 mL de resíduo por determinação. Recuperações entre 84 e 114 % foram obtidas com adição de Co (II) nas amostras de águas. O módulo de análise para determinação cádmio foi desenvolvido e otimizado utilizando duas mini-bombas peristálticas para bombeamento das soluções e esvaziamento do percurso, uma válvula solenoide de três vias e três válvulas solenoide de duas vias, uma cela de fluxo com longo caminho óptico (100 mm) e LED com emissão em 520 nm. O procedimento analítico para a determinação do cádmio foi baseado na formação do complexo pelo Cd (II) com o reagente ditizona em meio micelar com o surfactante Triton X100. O procedimento apresentou faixa de resposta linear de 15,0 a 175,0 µgL-1 de Cd (R = 0,997; n = 3), limite de detecção de 12,5 µgL-1, desvio padrão relativo de 0,57 % (n = 10) para uma amostra de 30 µgL-1 e frequência analítica de 43 amostras por hora. Recuperações entre 84 e 112 % foram obtidas com adição de Cd (II) nas amostras de águas. / This work deals with the development of automatic analytical procedures, based on multicommuted flow analysis process for spectrophotometric determination of cobalt and cadmium in water samples. The work involved the development of the analytical modules and the photometric detector using LEDs as electromagnetic radiation sources. The software to control the flow analysis module and to perform data acquisition, were developed using Quick BASIC4.5 as programming language. The analysis module for cobalt determination, employed solenoid mini-pumps for solutions pumping. The procedure was based on the cobalt catalytic effect on the Tiron oxidation by hydrogen peroxide and the photometric detection at 425 nm. After the necessary adjustments of the flow analysis module, the system showed good analytical performance. The following analytical characteristics for determination of cobalt in water were obtained: a relative standard deviation of 0.04% (n = 13) for a standard solution 0.5 µgL-1 Co, a linear response ranging from 0.13 to 1.5 µgL-1 Co (R = 0.998, n = 3), a detection limit of 0.06 µgL-1, analytical frequency of 42 samples determination per hour and a waste generation of 1.5 mL per determination. Recoveries between 84 and 114% were obtained with the addition of Co (II) in water samples. The analytical module for determination of cadmium was developed, using two peristaltic mini-pumps and solenoid valves. The LED based photometer was furnished with a flow cell of long optical path (100 mm) and a LED with maximum emission at 520 nm. The flow analysis module was assembled with ability to perform a closed loop strategy, which was implemented to improve sensitivity. The analytical procedure for the determination of cadmium was based on reaction of Cd (II) with dithizone in a micelle medium with the surfactant Triton X-100. The procedure showed a linear response ranging from 15.0 to 175.0 µgL-1 Cd (R = 0.997; n = 3), detection limit of 12.5 µgL-1, RSD 0.57% (n = 10) for a sample of 30 µgL-1 and analytical frequency of 43 samples per hour. Recoveries between 84 and 112% were obtained with addition of Cd (II) in water samples.
4

Desenvolvimento de procedimentos analíticos limpos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de cobalto e cádmio em águas / Development of clean analytical procedures employing multicommutation flow analysis systems for photometric determination of cobalt and cadmium in waters

Ticiane Silva Gondim 12 December 2016 (has links)
Esse trabalho tem como objetivo o desenvolvimento de procedimentos analíticos automáticos, empregando o processo de multicomutação em fluxo para determinação espectrofotométrica de cobalto e cádmio em amostras de águas. O trabalho envolveu o desenvolvimento dos módulos de análises para implementar os procedimentos analíticos baseados no processo de multicomutação, o sistema de detecção fotométrica empregando LED como fonte de radiação eletromagnética, o software para controle do módulo de análise e para efetuar aquisição de dados. O módulo de análise para determinação de cobalto foi desenvolvido, utilizando mini-bombas solenóide para o bombeamento das soluções. O procedimento analítico foi baseado na catálise do cobalto na reação de oxidação do Tiron pelo peróxido de hidrogênio e com o sistema de detecção espectrofotométrica com LED com emissão em 425 nm. Após os ajustes necessários do módulo de análise o sistema apresentou bom desempenho analítico. Para a determinação de cobalto em águas foram obtidas as seguintes características analíticas: desvio padrão relativo de 0,04 % (n = 13) para uma amostra com 0,5 µgL-1 de Co, faixa de resposta linear entre 0,13 a 1,5 µgL-1 de Co (R = 0,998, n = 3), limite de detecção de 0,06 µgL-1, frequência analítica de 42 determinações por hora e geração de 1,5 mL de resíduo por determinação. Recuperações entre 84 e 114 % foram obtidas com adição de Co (II) nas amostras de águas. O módulo de análise para determinação cádmio foi desenvolvido e otimizado utilizando duas mini-bombas peristálticas para bombeamento das soluções e esvaziamento do percurso, uma válvula solenoide de três vias e três válvulas solenoide de duas vias, uma cela de fluxo com longo caminho óptico (100 mm) e LED com emissão em 520 nm. O procedimento analítico para a determinação do cádmio foi baseado na formação do complexo pelo Cd (II) com o reagente ditizona em meio micelar com o surfactante Triton X100. O procedimento apresentou faixa de resposta linear de 15,0 a 175,0 µgL-1 de Cd (R = 0,997; n = 3), limite de detecção de 12,5 µgL-1, desvio padrão relativo de 0,57 % (n = 10) para uma amostra de 30 µgL-1 e frequência analítica de 43 amostras por hora. Recuperações entre 84 e 112 % foram obtidas com adição de Cd (II) nas amostras de águas. / This work deals with the development of automatic analytical procedures, based on multicommuted flow analysis process for spectrophotometric determination of cobalt and cadmium in water samples. The work involved the development of the analytical modules and the photometric detector using LEDs as electromagnetic radiation sources. The software to control the flow analysis module and to perform data acquisition, were developed using Quick BASIC4.5 as programming language. The analysis module for cobalt determination, employed solenoid mini-pumps for solutions pumping. The procedure was based on the cobalt catalytic effect on the Tiron oxidation by hydrogen peroxide and the photometric detection at 425 nm. After the necessary adjustments of the flow analysis module, the system showed good analytical performance. The following analytical characteristics for determination of cobalt in water were obtained: a relative standard deviation of 0.04% (n = 13) for a standard solution 0.5 µgL-1 Co, a linear response ranging from 0.13 to 1.5 µgL-1 Co (R = 0.998, n = 3), a detection limit of 0.06 µgL-1, analytical frequency of 42 samples determination per hour and a waste generation of 1.5 mL per determination. Recoveries between 84 and 114% were obtained with the addition of Co (II) in water samples. The analytical module for determination of cadmium was developed, using two peristaltic mini-pumps and solenoid valves. The LED based photometer was furnished with a flow cell of long optical path (100 mm) and a LED with maximum emission at 520 nm. The flow analysis module was assembled with ability to perform a closed loop strategy, which was implemented to improve sensitivity. The analytical procedure for the determination of cadmium was based on reaction of Cd (II) with dithizone in a micelle medium with the surfactant Triton X-100. The procedure showed a linear response ranging from 15.0 to 175.0 µgL-1 Cd (R = 0.997; n = 3), detection limit of 12.5 µgL-1, RSD 0.57% (n = 10) for a sample of 30 µgL-1 and analytical frequency of 43 samples per hour. Recoveries between 84 and 112% were obtained with addition of Cd (II) in water samples.
5

Determinação fotométrica de sulfato e cloreto em coque de petróleo, molibdênio em plantas e zinco em águas empregando multicomutação com bomba de seringa / Photometric determination of sulfate and chloride in petroleum coke, molybdenum in plants and zinc in water employing multicommutation with syringe pump

Santos Junior, Felisberto Gonçalves 07 December 2016 (has links)
Nesta tese foram desenvolvidos procedimentos analíticos fotométricos automáticos para determinação simultânea de sulfato e cloreto em coque de petróleo, molibdênio em plantas sem etapa de pré-concentração com solvente orgânico e zinco em águas empregando microextração líquido-líquido. Em todos os procedimentos reportados nesta tese, o módulo de análise foi baseado no processo de multicomutação, utilizou-se bomba de seringa como propulsor de fluidos e válvulas solenoide de três vias como dispositivos de comutação para controlar as inserções das alíquotas da amostra e dos reagentes no percurso analítico. As detecções fotométricas foram realizadas empregando fotômetros de LEDs, construídos para este projeto, equipados com celas de fluxo com caminho óptico longo (50,0 mm para cloreto, sulfato e zinco, 200,0 mm para molibdênio). O fotômetro foi construído com LEDs de alto brilho como máximos de emissão em 472 nm para cloreto, sulfato e molibdênio e 525 nm para zinco. Os procedimentos para determinação simultânea de sulfato e cloreto apresentaram faixa linear entre 10-700 mg L-1; 0,25-10 mg L-1; limite de detecção de 5,3 mg L-1; 0,16 mg L-1; coeficiente de variação de 3,0%; 0,9 % (n=10), respectivamente, e frequência de amostragem de 75 determinações por hora para cada analito. O procedimento para determinação de molibdênio apresentou faixa linear entre 50 - 500 ?g L-1, limite de detecção 9,1 ?g L-1, coeficiente de variação 1,07% (n=10) e frequência de amostragem de 51 determinações por hora. O procedimento para zinco apresentou uma faixa linear entre 10-100 ?g L-1, limite de detecção 8,3 ?g L-1, coeficiente de variação 3,3% (n=10) e frequência de amostragem de 19 determinações por hora / In this thesis, automated photometric analytical procedures for simultaneous determination of sulfate and chloride in petroleum coke, molybdenum in plants without pre-concentration step and zinc in water using liquid-liquid microextraction were developed. All procedures reported in this thesis, employed flow analysis modules based on multicommuted process, syringe pump for fluid propulsion and solenoid three-way valves as commutation devices the insertion aliquots of sample and reagents solutions in the analytical path. Photometric detections were performed, using LEDs-photometers, built for this project, equipped with flow cells with long optical path (50.0 mm for chloride, sulfate and zinc, 200.0 mm for molybdenum) and the high intense radiation beam LEDs with maximum emission at 472 nm for chloride, sulfate and molybdenum and 525 nm for zinc. The procedures for simultaneous determination of sulfate and chloride showed linear response between 10 to 700 mg L-1; 0.25 to 10 mg L-1; detection limit of 5.3 mg L-1; 0.16 mg L-1; variation coefficient of 3.0%; 0.9% (n = 10), respectively, and sampling throughput of 75 determinations per hour for each analyte. The procedure for molybdenum presented a linear response between 50 to 500 ?g L-1, detection limit of 9.1 ?g L-1, variation coefficient of 1.07% (n = 10) and sampling throughput of 51 determinations per hour. The procedure for zinc showed linear response between 10 to 100 ?g L-1, detection limit of 8.3 ?g L-1, variation coefficient of 3.3% (n = 10) and sampling throughput of 19 determinations per hour
6

Determinação fotométrica de sulfato e cloreto em coque de petróleo, molibdênio em plantas e zinco em águas empregando multicomutação com bomba de seringa / Photometric determination of sulfate and chloride in petroleum coke, molybdenum in plants and zinc in water employing multicommutation with syringe pump

Felisberto Gonçalves Santos Junior 07 December 2016 (has links)
Nesta tese foram desenvolvidos procedimentos analíticos fotométricos automáticos para determinação simultânea de sulfato e cloreto em coque de petróleo, molibdênio em plantas sem etapa de pré-concentração com solvente orgânico e zinco em águas empregando microextração líquido-líquido. Em todos os procedimentos reportados nesta tese, o módulo de análise foi baseado no processo de multicomutação, utilizou-se bomba de seringa como propulsor de fluidos e válvulas solenoide de três vias como dispositivos de comutação para controlar as inserções das alíquotas da amostra e dos reagentes no percurso analítico. As detecções fotométricas foram realizadas empregando fotômetros de LEDs, construídos para este projeto, equipados com celas de fluxo com caminho óptico longo (50,0 mm para cloreto, sulfato e zinco, 200,0 mm para molibdênio). O fotômetro foi construído com LEDs de alto brilho como máximos de emissão em 472 nm para cloreto, sulfato e molibdênio e 525 nm para zinco. Os procedimentos para determinação simultânea de sulfato e cloreto apresentaram faixa linear entre 10-700 mg L-1; 0,25-10 mg L-1; limite de detecção de 5,3 mg L-1; 0,16 mg L-1; coeficiente de variação de 3,0%; 0,9 % (n=10), respectivamente, e frequência de amostragem de 75 determinações por hora para cada analito. O procedimento para determinação de molibdênio apresentou faixa linear entre 50 - 500 ?g L-1, limite de detecção 9,1 ?g L-1, coeficiente de variação 1,07% (n=10) e frequência de amostragem de 51 determinações por hora. O procedimento para zinco apresentou uma faixa linear entre 10-100 ?g L-1, limite de detecção 8,3 ?g L-1, coeficiente de variação 3,3% (n=10) e frequência de amostragem de 19 determinações por hora / In this thesis, automated photometric analytical procedures for simultaneous determination of sulfate and chloride in petroleum coke, molybdenum in plants without pre-concentration step and zinc in water using liquid-liquid microextraction were developed. All procedures reported in this thesis, employed flow analysis modules based on multicommuted process, syringe pump for fluid propulsion and solenoid three-way valves as commutation devices the insertion aliquots of sample and reagents solutions in the analytical path. Photometric detections were performed, using LEDs-photometers, built for this project, equipped with flow cells with long optical path (50.0 mm for chloride, sulfate and zinc, 200.0 mm for molybdenum) and the high intense radiation beam LEDs with maximum emission at 472 nm for chloride, sulfate and molybdenum and 525 nm for zinc. The procedures for simultaneous determination of sulfate and chloride showed linear response between 10 to 700 mg L-1; 0.25 to 10 mg L-1; detection limit of 5.3 mg L-1; 0.16 mg L-1; variation coefficient of 3.0%; 0.9% (n = 10), respectively, and sampling throughput of 75 determinations per hour for each analyte. The procedure for molybdenum presented a linear response between 50 to 500 ?g L-1, detection limit of 9.1 ?g L-1, variation coefficient of 1.07% (n = 10) and sampling throughput of 51 determinations per hour. The procedure for zinc showed linear response between 10 to 100 ?g L-1, detection limit of 8.3 ?g L-1, variation coefficient of 3.3% (n = 10) and sampling throughput of 19 determinations per hour

Page generated in 0.175 seconds