• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de procedimentos analíticos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de vanádio em águas e estanho em alimentos / Development of analytical procedures employing multicommutation flow analysis systems for the photometric determination of vanadium in water and tin in foods

Dias, Tuanne dos Reis 06 November 2014 (has links)
Esta tese tem como foco o desenvolvimento de procedimentos analíticos automáticos, visando as determinações fotométricas de vanádio e de estanho em águas e em alimentos empregando o processo de multicomutação em fluxo. Um microcontrolador da família PIC e um programa escrito em linguagem Visual Basic 6.0 foram empregados para controle dos dispositivos e aquisição de dados. A unidade de detecção foi construída empregando LED de alto brilho e celas de fluxo com longo caminho óptico (50-200 mm) para ganho em sensibilidade. O módulo de análises, empregando bombas solenoide como propulsores de fluido e o fotômetro foram integrados, formando uma unidade compacta. A determinação de vanádio em águas, mineral e de rio, foi baseada na redução do V(V) à V(IV) com ácido ascórbico e posterior complexação com Eriocromo Cianina R (ECR). Empregando uma cela de 150 mm, o sistema apresentou resposta linear de 0,02 a 1,00 mg L-1, limite de detecção estimado em 13 ?g L-1, coeficiente de variação de 0,87% (n=10) e frequência analítica de 47 determinações por hora. Recuperações entre 89 e 109% foram obtidas para adição de V(V) nas amostras de águas. O procedimento para a determinação de estanho em alimentos foi desenvolvido empregando bomba de multi-seringa como unidade de propulsão de fluidos, cela de fluxo com caminho óptico de 200 mm e parada de fluxo de 50 s. Baseado na reação do Sn(IV) com o violeta de pirocatecol (PCV) na presença de surfactantes, o sistema apresentou resposta linear de 0,10 a 1,25 mg L-1, limite de detecção estimado em 0,04 mg L-1, coeficiente de variação de 1,30% (n=10) e frequência analítica de 49 determinações por hora. Recuperações entre 95 e 115% foram obtidas com a adição de Sn(IV) às amostras de alimentos. / Automatic analytical procedures for photometric determinations of vanadium in water and tin in foods were developed using the multicommutation flow analysis process. A microcontroller of the PIC family and a software written in Visual Basic 6.0 language were used for devices control and data acquisition. Detection unit was designed to use high brightness LED and long optical pathlength flow cells (50-200 mm) to improve sensitivity. The flow analysis module using solenoid mini-pumps as fluid propelling devices and the photometer were integrated in order to form a compact unit. The determination of vanadium in mineral and river waters was based on the reduction of V(V) to V(IV) with ascorbic acid and subsequent complexation with Eriochrome Cyanine R (ECR). Employing flow cell of 150 mm, the system presented linear response between 0.02 and 1.00 mg L-1, detection limit of 13 ?g L-1, variation coefficient of 0.87% (n=10) and sampling throughput of 47 determinations per hour. Recoveries between 89 and 109% were attained for vanadium spiked to mineral and river water. The procedure for determination of tin in foods was development employing a multi-syringe pump as fluid propelling device, a flow cell with optical pathlength of 200 mm and stop flow of 50 s. The procedure was based on the reaction of Sn(IV) with pyrocatechol violet (PCV) in the presence of surfactants, presented linear response between 0.10 and 1.25 mg L-1, detection limit of 0.04 mg L-1, variation coefficient of 1.30% (n=10) and sampling throughput of 49 determination per hour. Recoveries between 95 and 115% were attained for tin spiked samples
2

Desenvolvimento de procedimentos analíticos empregando multicomutação em sistemas de análises em fluxo para determinação fotométrica de vanádio em águas e estanho em alimentos / Development of analytical procedures employing multicommutation flow analysis systems for the photometric determination of vanadium in water and tin in foods

Tuanne dos Reis Dias 06 November 2014 (has links)
Esta tese tem como foco o desenvolvimento de procedimentos analíticos automáticos, visando as determinações fotométricas de vanádio e de estanho em águas e em alimentos empregando o processo de multicomutação em fluxo. Um microcontrolador da família PIC e um programa escrito em linguagem Visual Basic 6.0 foram empregados para controle dos dispositivos e aquisição de dados. A unidade de detecção foi construída empregando LED de alto brilho e celas de fluxo com longo caminho óptico (50-200 mm) para ganho em sensibilidade. O módulo de análises, empregando bombas solenoide como propulsores de fluido e o fotômetro foram integrados, formando uma unidade compacta. A determinação de vanádio em águas, mineral e de rio, foi baseada na redução do V(V) à V(IV) com ácido ascórbico e posterior complexação com Eriocromo Cianina R (ECR). Empregando uma cela de 150 mm, o sistema apresentou resposta linear de 0,02 a 1,00 mg L-1, limite de detecção estimado em 13 ?g L-1, coeficiente de variação de 0,87% (n=10) e frequência analítica de 47 determinações por hora. Recuperações entre 89 e 109% foram obtidas para adição de V(V) nas amostras de águas. O procedimento para a determinação de estanho em alimentos foi desenvolvido empregando bomba de multi-seringa como unidade de propulsão de fluidos, cela de fluxo com caminho óptico de 200 mm e parada de fluxo de 50 s. Baseado na reação do Sn(IV) com o violeta de pirocatecol (PCV) na presença de surfactantes, o sistema apresentou resposta linear de 0,10 a 1,25 mg L-1, limite de detecção estimado em 0,04 mg L-1, coeficiente de variação de 1,30% (n=10) e frequência analítica de 49 determinações por hora. Recuperações entre 95 e 115% foram obtidas com a adição de Sn(IV) às amostras de alimentos. / Automatic analytical procedures for photometric determinations of vanadium in water and tin in foods were developed using the multicommutation flow analysis process. A microcontroller of the PIC family and a software written in Visual Basic 6.0 language were used for devices control and data acquisition. Detection unit was designed to use high brightness LED and long optical pathlength flow cells (50-200 mm) to improve sensitivity. The flow analysis module using solenoid mini-pumps as fluid propelling devices and the photometer were integrated in order to form a compact unit. The determination of vanadium in mineral and river waters was based on the reduction of V(V) to V(IV) with ascorbic acid and subsequent complexation with Eriochrome Cyanine R (ECR). Employing flow cell of 150 mm, the system presented linear response between 0.02 and 1.00 mg L-1, detection limit of 13 ?g L-1, variation coefficient of 0.87% (n=10) and sampling throughput of 47 determinations per hour. Recoveries between 89 and 109% were attained for vanadium spiked to mineral and river water. The procedure for determination of tin in foods was development employing a multi-syringe pump as fluid propelling device, a flow cell with optical pathlength of 200 mm and stop flow of 50 s. The procedure was based on the reaction of Sn(IV) with pyrocatechol violet (PCV) in the presence of surfactants, presented linear response between 0.10 and 1.25 mg L-1, detection limit of 0.04 mg L-1, variation coefficient of 1.30% (n=10) and sampling throughput of 49 determination per hour. Recoveries between 95 and 115% were attained for tin spiked samples
3

Determinação fotométrica de sulfato e cloreto em coque de petróleo, molibdênio em plantas e zinco em águas empregando multicomutação com bomba de seringa / Photometric determination of sulfate and chloride in petroleum coke, molybdenum in plants and zinc in water employing multicommutation with syringe pump

Santos Junior, Felisberto Gonçalves 07 December 2016 (has links)
Nesta tese foram desenvolvidos procedimentos analíticos fotométricos automáticos para determinação simultânea de sulfato e cloreto em coque de petróleo, molibdênio em plantas sem etapa de pré-concentração com solvente orgânico e zinco em águas empregando microextração líquido-líquido. Em todos os procedimentos reportados nesta tese, o módulo de análise foi baseado no processo de multicomutação, utilizou-se bomba de seringa como propulsor de fluidos e válvulas solenoide de três vias como dispositivos de comutação para controlar as inserções das alíquotas da amostra e dos reagentes no percurso analítico. As detecções fotométricas foram realizadas empregando fotômetros de LEDs, construídos para este projeto, equipados com celas de fluxo com caminho óptico longo (50,0 mm para cloreto, sulfato e zinco, 200,0 mm para molibdênio). O fotômetro foi construído com LEDs de alto brilho como máximos de emissão em 472 nm para cloreto, sulfato e molibdênio e 525 nm para zinco. Os procedimentos para determinação simultânea de sulfato e cloreto apresentaram faixa linear entre 10-700 mg L-1; 0,25-10 mg L-1; limite de detecção de 5,3 mg L-1; 0,16 mg L-1; coeficiente de variação de 3,0%; 0,9 % (n=10), respectivamente, e frequência de amostragem de 75 determinações por hora para cada analito. O procedimento para determinação de molibdênio apresentou faixa linear entre 50 - 500 ?g L-1, limite de detecção 9,1 ?g L-1, coeficiente de variação 1,07% (n=10) e frequência de amostragem de 51 determinações por hora. O procedimento para zinco apresentou uma faixa linear entre 10-100 ?g L-1, limite de detecção 8,3 ?g L-1, coeficiente de variação 3,3% (n=10) e frequência de amostragem de 19 determinações por hora / In this thesis, automated photometric analytical procedures for simultaneous determination of sulfate and chloride in petroleum coke, molybdenum in plants without pre-concentration step and zinc in water using liquid-liquid microextraction were developed. All procedures reported in this thesis, employed flow analysis modules based on multicommuted process, syringe pump for fluid propulsion and solenoid three-way valves as commutation devices the insertion aliquots of sample and reagents solutions in the analytical path. Photometric detections were performed, using LEDs-photometers, built for this project, equipped with flow cells with long optical path (50.0 mm for chloride, sulfate and zinc, 200.0 mm for molybdenum) and the high intense radiation beam LEDs with maximum emission at 472 nm for chloride, sulfate and molybdenum and 525 nm for zinc. The procedures for simultaneous determination of sulfate and chloride showed linear response between 10 to 700 mg L-1; 0.25 to 10 mg L-1; detection limit of 5.3 mg L-1; 0.16 mg L-1; variation coefficient of 3.0%; 0.9% (n = 10), respectively, and sampling throughput of 75 determinations per hour for each analyte. The procedure for molybdenum presented a linear response between 50 to 500 ?g L-1, detection limit of 9.1 ?g L-1, variation coefficient of 1.07% (n = 10) and sampling throughput of 51 determinations per hour. The procedure for zinc showed linear response between 10 to 100 ?g L-1, detection limit of 8.3 ?g L-1, variation coefficient of 3.3% (n = 10) and sampling throughput of 19 determinations per hour
4

Determinação fotométrica de sulfato e cloreto em coque de petróleo, molibdênio em plantas e zinco em águas empregando multicomutação com bomba de seringa / Photometric determination of sulfate and chloride in petroleum coke, molybdenum in plants and zinc in water employing multicommutation with syringe pump

Felisberto Gonçalves Santos Junior 07 December 2016 (has links)
Nesta tese foram desenvolvidos procedimentos analíticos fotométricos automáticos para determinação simultânea de sulfato e cloreto em coque de petróleo, molibdênio em plantas sem etapa de pré-concentração com solvente orgânico e zinco em águas empregando microextração líquido-líquido. Em todos os procedimentos reportados nesta tese, o módulo de análise foi baseado no processo de multicomutação, utilizou-se bomba de seringa como propulsor de fluidos e válvulas solenoide de três vias como dispositivos de comutação para controlar as inserções das alíquotas da amostra e dos reagentes no percurso analítico. As detecções fotométricas foram realizadas empregando fotômetros de LEDs, construídos para este projeto, equipados com celas de fluxo com caminho óptico longo (50,0 mm para cloreto, sulfato e zinco, 200,0 mm para molibdênio). O fotômetro foi construído com LEDs de alto brilho como máximos de emissão em 472 nm para cloreto, sulfato e molibdênio e 525 nm para zinco. Os procedimentos para determinação simultânea de sulfato e cloreto apresentaram faixa linear entre 10-700 mg L-1; 0,25-10 mg L-1; limite de detecção de 5,3 mg L-1; 0,16 mg L-1; coeficiente de variação de 3,0%; 0,9 % (n=10), respectivamente, e frequência de amostragem de 75 determinações por hora para cada analito. O procedimento para determinação de molibdênio apresentou faixa linear entre 50 - 500 ?g L-1, limite de detecção 9,1 ?g L-1, coeficiente de variação 1,07% (n=10) e frequência de amostragem de 51 determinações por hora. O procedimento para zinco apresentou uma faixa linear entre 10-100 ?g L-1, limite de detecção 8,3 ?g L-1, coeficiente de variação 3,3% (n=10) e frequência de amostragem de 19 determinações por hora / In this thesis, automated photometric analytical procedures for simultaneous determination of sulfate and chloride in petroleum coke, molybdenum in plants without pre-concentration step and zinc in water using liquid-liquid microextraction were developed. All procedures reported in this thesis, employed flow analysis modules based on multicommuted process, syringe pump for fluid propulsion and solenoid three-way valves as commutation devices the insertion aliquots of sample and reagents solutions in the analytical path. Photometric detections were performed, using LEDs-photometers, built for this project, equipped with flow cells with long optical path (50.0 mm for chloride, sulfate and zinc, 200.0 mm for molybdenum) and the high intense radiation beam LEDs with maximum emission at 472 nm for chloride, sulfate and molybdenum and 525 nm for zinc. The procedures for simultaneous determination of sulfate and chloride showed linear response between 10 to 700 mg L-1; 0.25 to 10 mg L-1; detection limit of 5.3 mg L-1; 0.16 mg L-1; variation coefficient of 3.0%; 0.9% (n = 10), respectively, and sampling throughput of 75 determinations per hour for each analyte. The procedure for molybdenum presented a linear response between 50 to 500 ?g L-1, detection limit of 9.1 ?g L-1, variation coefficient of 1.07% (n = 10) and sampling throughput of 51 determinations per hour. The procedure for zinc showed linear response between 10 to 100 ?g L-1, detection limit of 8.3 ?g L-1, variation coefficient of 3.3% (n = 10) and sampling throughput of 19 determinations per hour

Page generated in 0.4249 seconds