Spelling suggestions: "subject:"acridium."" "subject:"diridium.""
201 |
Estudo e desenvolvimento de uma semente de irídio-192 para aplicação em câncer oftálmico / Study and development of an iridium-192 seed for use in opthalmic cancerMATTOS, FABIO R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:32Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
202 |
Determinacao de defeitos em profundidade (estereoradiografia)CARVALHO, GILBERTO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:50Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:49Z (GMT). No. of bitstreams: 1
07313.pdf: 4614224 bytes, checksum: b35f3b3a0d88e2ee74e856c2c7883aaf (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
203 |
Determinacao de iridio em baixas concentracoes(sub ng gsup-1) em materiais geologicos por ativacao neutronicaMORCELLI, CLAUDIA P.R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:49Z (GMT). No. of bitstreams: 1
06633.pdf: 3576512 bytes, checksum: 5fb55fd14239cf9ae62a4825e5902dc6 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
204 |
Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy / Modelagem pelo método de Monte Carlo do paciente e das complexidades dos tratamentos braquiterápicos com alta taxa de doseFONSECA, GABRIEL P. 10 December 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-10T16:54:22Z
No. of bitstreams: 0 / Made available in DSpace on 2015-12-10T16:54:22Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:11/01913-4
|
205 |
Sintese e reatividade de complexos de iridio(I) / Synthesis and reactivity of complexes of iridium(I)Paula, Vanderlei Inacio de 05 August 2018 (has links)
Orientadores: Regina Buffon, Regina Mara Silva Pereira / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-05T04:42:43Z (GMT). No. of bitstreams: 1
Paula_VanderleiInaciode_M.pdf: 3879101 bytes, checksum: f5ec10f585405c9d2de0c5df2a99eb1b (MD5)
Previous issue date: 2004 / Mestrado / Quimica Inorganica / Mestre em Química
|
206 |
Caracterizacao dosimetrica das fontes de braquiterapia - na forma de fios de iridio-192 de baixa taxa de dose, produzidos pelo Laboratorio de Fontes de Braquiterapia CTRS/IPEN/CNEN-SPSILVA, MARCO A. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:59Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:43Z (GMT). No. of bitstreams: 1
09608.pdf: 4456870 bytes, checksum: 7029deaa1ca99f712b8a29825c470ebd (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
207 |
Estudo e desenvolvimento de uma semente de irídio-192 para aplicação em câncer oftálmico / Study and development of an iridium-192 seed for use in opthalmic cancerMATTOS, FABIO R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:32Z (GMT). No. of bitstreams: 0 / Mesmo não estando entre os casos de câncer com maior incidência, os tumores oculares têm acometido a população brasileira. O Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP), juntamente à Escola Paulista de Medicina (UNIFESP), criou um projeto que visa o desenvolvimento e implementação de um tratamento de câncer oftálmico alternativo que consiste na utilização de sementes de irídio-192 em braquiterapia. O Projeto surgiu pelo motivo da Escola Paulista tratar muitos casos oncológicos no âmbito do Sistema Único de Saúde (SUS) e pela experiência em pesquisas de fontes radioativas seladas do grupo de braquiterapia do IPEN. A metodologia foi desenvolvida a partir da infraestrutura disponível e pela experiência dos pesquisadores. O protótipo desenvolvido da semente se apresenta com um núcleo (irídio em liga de irídio-platina) de 3,0mm de comprimento selado por uma cápsula de titânio de 0,8mm de diâmetro externo, 0,05mm de espessura de parede e 4,5mm de comprimento. Nenhum estudo sobre a confecção destas sementes foi encontrado em literatura disponível. Criou-se uma metodologia que envolveu: caracterização do fio, criação do dispositivo para ativação neutrônica dos núcleos e testes de estanqueidade da fonte produzida. A análise dos resultados comprovaram a viabilidade do método. Como sugestão para trabalhos futuros, estudos quanto à metrologia e dosimetria destas fontes e aprimoramento da metodologia devem ser realizados, para uma futura implementação em caráter nacional. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
208 |
Determinacao de defeitos em profundidade (estereoradiografia)CARVALHO, GILBERTO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:50Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:49Z (GMT). No. of bitstreams: 1
07313.pdf: 4614224 bytes, checksum: b35f3b3a0d88e2ee74e856c2c7883aaf (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
209 |
Determinacao de iridio em baixas concentracoes(sub ng gsup-1) em materiais geologicos por ativacao neutronicaMORCELLI, CLAUDIA P.R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:31Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:49Z (GMT). No. of bitstreams: 1
06633.pdf: 3576512 bytes, checksum: 5fb55fd14239cf9ae62a4825e5902dc6 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
210 |
Monte Carlo modeling of the patient and treatment delivery complexities for high dose rate brachytherapy / Modelagem pelo método de Monte Carlo do paciente e das complexidades dos tratamentos braquiterápicos com alta taxa de doseFONSECA, GABRIEL P. 10 December 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-12-10T16:54:22Z
No. of bitstreams: 0 / Made available in DSpace on 2015-12-10T16:54:22Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tratamentos braquiterápicos são comumente realizados conforme o relatório da American Association of Physicists in Medicine (AAPM), Task Group report TG-43U1, o qual define o formalismo para cálculo de dose absorvida na água e não considera a composição dos materiais, densidades, dimensões do paciente e o efeito dos aplicadores. Estes efeitos podem ser significantes, conforme descrito pelo recente relatório da AAPM, Task Group report TG- 186, que define diretrizes para que sistemas de planejamento modernos, capazes de considerar as complexidades descritas acima, sejam implementados. Esta tese tem como objetivo contribuir para o aumento da exatidão dos planejamentos de tratamento braquiterápicos, seguindo as recomendações do TG-186 e indo além do mesmo. Um software foi desenvolvido para integrar planejamentos de tratamento e simulações pelo método de Monte Carlo (MC); modelos acurados, CAD-Mesh, foram utilizados para representar aplicadores braquiterápicos; Grandezas utilizadas para reportar dose absorvida, Dw,m (dose para água no meio) e Dm,m (dose para o meio no meio), foram calculadas para um tratamento de cabeça e pescoço, considerando a teoria para pequenas (SCT small cavity theory) e grandes cavidades (LCT large cavity theory); a componente da dose em razão do movimento da fonte foi avaliada para tratamentos de próstata e ginecológicos. Perfis de velocidade obtidos na literatura foram utilizados; medidas de velocidade de uma fonte braquiterapica foram realizadas com uma câmera de alta taxa de aquisição. Cálculos de dose obtidos usando MC (incluindo a composição e densidade dos tecidos, ar e o aplicador) mostram sobredoses de aproximadamente 5% dentro do volume alvo, em um tratamento ginecológico, quando comparados aos resultados obtidos com um meio homogêneo de água. Por sua vez, subdoses de aproximadamente 5% foram observadas ao considerar a composição dos tecidos e regiões com ar em um tratamento intersticial de braço. Um aplicador cilíndrico oco resultou na sobredose observada no caso ginecológico, ressaltando a necessidade de modelos acurados para representar os aplicadores. Os modelos CAD-Mesh utilizados incluem um aplicador Fletcher-Williamson, com blindagem, e um balão deformável para irradiação de mama. Os resultados obtidos com estes modelos são equivalentes aos obtidos com modelos geométricos convencionais. Este recurso pode ser conveniente para aplicadores complexos e/ou quando o projeto dos aplicadores for disponibilizado pelo fabricante. Cálculos de dose, com a composição real dos tecidos humanos, podem apresentar diferenças significativas em razão da grandeza adotada. Diferenças entre Dm,m e Dw,m (SCT ou LCT) chegam a 14% em razão da composição do osso. A metodologia adotada (SCT ou LCT) resulta em diferenças de até 28% para o osso e 36% para os dentes. A componente de dose de trânsito também pode levar a diferenças significativas, uma vez que baixas velocidades ou movimentos uniformemente acelerados foram descritos na literatura. Considerando a pior condição e sem incluir nenhuma correção no tempo de parada, a dose de trânsito pode chegar a 3% da dose prescrita para um caso ginecológico, com 4 cateteres, e até 11.1% da dose prescrita para um tratamento de próstata, com 16 cateteres. A dose de trânsito para a fonte avaliada (velocidade obtida experimentalmente) não é uniformemente distribuída e pode levar a sub ou sobredoses de até 1.4% das doses comumente prescritas (310 Gy). Os tópicos estudados são relevantes para tratamentos braquiterápicos e podem contribuir para o aumento de sua acurácia. Os efeitos estudados podem ser avaliados com o uso do software, associado a um código MC, desenvolvido. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:11/01913-4
|
Page generated in 0.0537 seconds