• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo tomográfico de pressões de colapso alveolar e níveis isogravitacionais em pulmões de pacientes com SDRA e LPA / Tomographic study of alveolar collapsing pressures and isogravitational levels and in the lungs of patients with ARDS and/or ALI

Dash, Shari Anne Ahmed El 12 January 2009 (has links)
Estudo clínico prospectivo, em 11 pacientes com SARA ou LPA, avaliando o comportamento regional da densidade do tecido pulmonar e do colapso alveolar ao longo dos três eixos do espaço. Foram realizadas tomografias seriadas, após manobra de recrutamento inicial e após níveis de PEEP progressivamente decrescentes. Regressão linear múltipla (R2=0.83) mostrou importante gradiente no eixo gravitacional (p<0.001) e não no sentido céfalo-caudal (p<0.001), nem da direita para a esquerda (p<0.05). Isto corrobora o conceito do pulmão líquido, em que a resultante das pressões exercidas pelo diafragma, estruturas mediastinais e derrames seria transmitida uniformemente pelo tecido pulmonar. Cada um destes níveis isogravitacionais tem uma pressão crítica de fechamento (Pclosing), que é maior do que a pressão superimposta calculada. PEEP tem um efeito homogeneizador sobre o parênquima pulmonar. Dentre os parâmetros clínicos estudados, Pflex mostrou a pior correlação com colapso pulmonar documentado enquanto PO2 e a complacência máxima se mostraram equivalentes. / A prospective clinical study performed on 11 patients with ARDS or ALI with the intention of studying the regional behavior of lung tissue density and alveolar collapse along the three spatial axes. An initial recruitment maneuver was followed by multiple semi-complete CT scans at descending levels of PEEP. Multiple linear regression (R2=0.83) showed a gravitational gradient of densities and collapse (p<0.001) and no cephalo-caudal (p<0.001) or right-toleft increase (p<0.05), corroborating the liquid-like behavior of the lung. Pressure exerted by mediastinal structures, chest wall and effusions is transmitted uniformly throughout the lung. PEEP has a homogenizing effect on lung parenchyma. Among commonly used clinical surrogates, Pflex showed the worst correlation with actual lung collapse, while arterial PO2 and compliance were equivalent.
2

Estudo tomográfico de pressões de colapso alveolar e níveis isogravitacionais em pulmões de pacientes com SDRA e LPA / Tomographic study of alveolar collapsing pressures and isogravitational levels and in the lungs of patients with ARDS and/or ALI

Shari Anne Ahmed El Dash 12 January 2009 (has links)
Estudo clínico prospectivo, em 11 pacientes com SARA ou LPA, avaliando o comportamento regional da densidade do tecido pulmonar e do colapso alveolar ao longo dos três eixos do espaço. Foram realizadas tomografias seriadas, após manobra de recrutamento inicial e após níveis de PEEP progressivamente decrescentes. Regressão linear múltipla (R2=0.83) mostrou importante gradiente no eixo gravitacional (p<0.001) e não no sentido céfalo-caudal (p<0.001), nem da direita para a esquerda (p<0.05). Isto corrobora o conceito do pulmão líquido, em que a resultante das pressões exercidas pelo diafragma, estruturas mediastinais e derrames seria transmitida uniformemente pelo tecido pulmonar. Cada um destes níveis isogravitacionais tem uma pressão crítica de fechamento (Pclosing), que é maior do que a pressão superimposta calculada. PEEP tem um efeito homogeneizador sobre o parênquima pulmonar. Dentre os parâmetros clínicos estudados, Pflex mostrou a pior correlação com colapso pulmonar documentado enquanto PO2 e a complacência máxima se mostraram equivalentes. / A prospective clinical study performed on 11 patients with ARDS or ALI with the intention of studying the regional behavior of lung tissue density and alveolar collapse along the three spatial axes. An initial recruitment maneuver was followed by multiple semi-complete CT scans at descending levels of PEEP. Multiple linear regression (R2=0.83) showed a gravitational gradient of densities and collapse (p<0.001) and no cephalo-caudal (p<0.001) or right-toleft increase (p<0.05), corroborating the liquid-like behavior of the lung. Pressure exerted by mediastinal structures, chest wall and effusions is transmitted uniformly throughout the lung. PEEP has a homogenizing effect on lung parenchyma. Among commonly used clinical surrogates, Pflex showed the worst correlation with actual lung collapse, while arterial PO2 and compliance were equivalent.

Page generated in 0.099 seconds